| 1 | L1₹2.1 CrAdmitted-Finance | ₹2.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.1 Cr+₹2.6 L (1.22%)Admitted-Finance BANKERS VILLA VAZHOTTUKONAM VATTIYOORKKAVU P O TRIVANDRUM 695 013 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695013 | ₹2.1 Cr+₹2.6 L (1.22%) | L2 | Admitted-Finance |
| 3 | L3₹2.2 Cr+₹4.7 L (2.22%)Admitted-Finance | ₹2.2 Cr+₹4.7 L (2.22%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical technically not qualified |
| Sl No | Description | Qty | Unit | AAYKAYCONSTRUCTIONS L1 | Bankers Construction L2 | CUBIX INFRASTRUCTURES L3 |
|---|---|---|---|---|---|---|
| 1.00COMPONENT 1-MUSEUM OF MURALS | ||||||
| 1.01 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 257 | cum | - | - | - |
| 1.02 | 4.1.8 : Providing and laying in position Cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size). Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference. | 103.5 | cum | - | - | - |
| 1.03 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete. (Centering and shuttering for different category of work may be considered separately.) | 111 | sqm | - | - | - |
| 1.04 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | 65 | sqm | - | - | - |
| 1.05 | 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | 142 | sqm | - | - | - |
| 1.06 | 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | 160 | sqm | - | - | - |
| 1.07 | 5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) | 62 | sqm | - | - | - |
| 1.08 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | 354 | sqm | - | - | - |
| 1.09 | 5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level, The Compressive strength of concrete has to be tested in Govt labs as per IS. | 62 | cum | - | - | - |
Tender Value
₹2.1 Cr
EMD Value
₹1 L
Closing Date
15 Jul 2020, 11:00 amClosed
DGM Subcontract
KEL Kochi
CONSTRUCTION OF THODEEKALAM TEMPLE MUSEUM OF MURALS WITH TOURISM AMENITIES, THALASSERY HERITAGE PROJECT, KANNUR DISTRICT
2020_KEL_366803_1
KRO/ BDC/558/2020
Open Tender
Civil Works - Others
Item Rate
300 days
KEL Kochi
As per NIT
5 documents required · 5 mandatory
₹8,850
online
₹1 L
Yes
17 Jul 2020
23 Jun 2020
17 Jul 2020
23 Jun 2020
15 Jul 2020
23 Jun 2020
23 Jun 2020 - 15 Jul 2020
Amount
COMPONENT 1-MUSEUM OF MURALS
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position Cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size). Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete. (Centering and shuttering for different category of work may be considered separately.)
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level, The Compressive strength of concrete has to be tested in Govt labs as per IS.
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level. The Compressive strength of concrete has to be tested in Govt labs as per IS.
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more. Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference. Testing strength and quality of steel in Govt labs as per IS.
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge. (After deducting earth available at site from excavation).
od271684/2019_2020 : Exposed Laterate masonry with neatly dressed laterate stone of size 30X20X20cm or nearest size in cement mortar 1:6 for superstructure above plinth level up to floor two levelincluding all cost of materials, labour charges etc
50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete. Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered).
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes. Make: TATA, JSW, VIZAG, SAIL or eq.
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work.
12.48 : Providing & fixing on Roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) including prior sample approval and direction of Engineer at site.
12.49 : Providing & laying on Roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ) including prior sample approval and direction of Engineer at site.
od271898/2019_2020 : Providing & fixing on Roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) including prior sample approval and direction of Engineer at site.
od271928/2019_2020 : Providing and fixing good quality Second class teak wood / Jack wood eaves board 20 cm wide and 2.5 cm thick with the architectural design, approval of Client/ KEL including all cost and labour charges etc. complete as per the direction of Engineer at site.
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
50.13.1 : 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality second class teak wood /jack wood
9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood 35 mm thick shutters
9.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood
od271977/2019_2020 : Providing and fixing of Door lock: Atom six turn Lock and ultra key including all cost and labour charges etc.complete
od272163/2019_2020 : Providing and fixing antique brass handle ring including all cost and labour charges (Brass Heavy duty with IS)
od272155/2019_2020 : Providing and fixing 4" SS punit hinges antique ( approved by the engineer)including all cost and labour charges.( Heavy duty with IS )
od272339/2019_2020 : Providing and fixing 4" or nearest size punit antique tower bolt including all cost and labour charges (Brass Heavy duty with IS)
od272340/2019_2020 : Providing and fixing 8" or nearest size punit antique tower bolt including all cost and labour charges (Brass Heavy duty with IS)
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc. Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference.
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer. Make: Asian, Berger, Nerolac or eq. in the order of pref.
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm. Make: Jotun,Asian, Berger, Nerolac or eq. in the order of pref.
od273606/2019_2020 : Preparation of wood surface for melamine polish
od273618/2019_2020 : Melamine polishing on wood work ( one or more coat) for new work.
11.26.1 : Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) 25 mm thick including prior sample approval etc complete as per the direction of Engineer at site.
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. Make: Khajaria, Johnson, RAK, NITCO, Cera or eq. in the order of pref and prior sample approval from KEL/client.
11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
od272343/2019_2020 : Providing and fixing good quality Second class teak wood / Jack wood handrails with top section of size 10.00cm x 6.00cm and vertical section of size 4.45cm x 4.45cm. with the architectural design including all cost and labour charges etc. complete
od273527/2019_2020 : Providing and fixing teak wood panelling 12mm thick second class teak wood including all cost and conveyance of materials etc complete
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge. (Quantity by level calculation and reporting to CTE as per norms and quality test at Govt. lab).
od272502/2019_2020 : Providing and laying rough finish granite stone (sadarhalli ) flooring in required design and pattern (90x50 cm or nearest) in linear as well as curvilinear all complete as per the architectural drawing with 50mm thick stone slab over 50mm thick base of sand etc. complete as specified including prior sample approval etc complete as per the direction of Engineer at site.
od272503/2019_2020 : Supplying and fixing neatly dressed shaped rubble 30 x 30 x 7.5 cm or nearest available size paving tiles over bed of coarse sand of average thickness 50 mm after levelling and compacting the sub base, filling the joints with fine sand including cost and conveyance of all materials and labour charges etc. complete as per the direction of departmental officers.
15.31 : Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead including handing over servicable material to Client and getting receipt.
15.33 : Dismantling wooden ballies in posts and struts including stacking within 50 metre lead including handing over servicable material to Client and getting receipt.
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below including handing over servicable material to Client and getting receipt.
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar including handing over servicable material to Client and getting receipt.
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge including handing over servicable material to Client and getting receipt.
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar including handing over servicable material to Client and getting receipt.
od272516/2019_2020 : Providing and fixing wall mounting European water closet with seat cover (white colour), seat cover& slim concealed cistern , installation kit and drain pipe connection set for wall hung WC including control plate moon design all chrome or equivalent of approved shape with ‘P’ trape, of removable soft matching seat cover , fixing of the above closet with stainless steel rack bolt (seam bolt) white cap etc. complete with supply of brass pan connectors, noise reduction gasket and necessary fasteners. Providing water and soil connections to the closet, together with cutting and making good the walls and floors wherever required, quality and brand as approved by the consultant, etc. complete. Providing and fixing WC-connection socket with lip (Quality controlled in accordance with DIN) Make: Kohler/ Equivalent (For rooms)
od272521/2019_2020 : Supplying and fixing CP Health Faucet superior quality including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. Make: Kohler/ Equivalent
od272524/2019_2020 : Providing and fixing Table top wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require Make: Kohlerƒ Equivalent.
od272531/2019_2020 : Providing and fixing CP Towel Ring fixed with SS screws on to the toilet Approved Make Make: Kohler& Equivalent.
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
50.18.9.2.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints as per direction of Engineer in Charge.20 mm dia 12 Kgf/cm2
50.18.9.3.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge 25 mm dia 12Kfg/cm2
50.18.9.5.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
od272654/2019_2020 : Liasoning charge for Preparation of completion Report, Arranging for Inspection, attending to defects report , preparation of as fitted drawing and obtaining approval and clearance from Water Authority. Connections , Fees, deposit including necessary statutory fees/charges etc complete as per the direction of Engineer at site.
Providing and fixing Wooden armed office chair made of seasoned sheesham wood, cane seat and back finished with sprit polish , using Front leg 2”x2” turned, back legs 1-3/8” seat rails 2 ½”x2 ½”, back top rail 2 ½”x1” curved shape back slates 1 ¾”x7/8” middle rail 1 ¾” arms 7/8” thick and bottom rail 1 ¾”, width of front of seat 22” width of back 19” of seat (including back legs, 18” height of arms 9” and height of back 38”) all complete as per design, drawing, prior approval of client/ KEL. and the direction of Engineer in charge.
Providing and fixing Wooden armless chair made of seasoned sheesham wood finished with sprit polish using Front legs 2”x2” tapered, back legs 1 ¼” thick (curved), top rail and seat rail 1” thick, under framing 1 ¼” x7/8” slates 1”x3/8” sheet frame and shape of wood 1 ¾” thick seat slates 1 ½”x1 ½”x3/4 back height 34” seat height 18”, depth 18”, seat front 18”, width of back 16” all complete as per design, drawing, prior approval of client/ KEL. and the direction of Engineer in charge.
Providing and fixing Centre Table of Size 3’x1.5’x1.5’ made of seasoned sheesham wood / sunmica top frame 19 mm commercial ply board with good quality of sunmica finished with sprit polish using Legs 16”x1 ¾”x1 ¾” tapered top rail 2”x1” thick top side rail 2”x1” thick bottom rail 1.5”x ¾’ thick top frame 3”x1” thick. all complete as per design, drawing, prior approval of client/ KEL. and the direction of Engineer in charge.
od273863/2019_2020 : Providing and fixing Two tired open shelf of size 200 x 120 and 5 or more rack using good quality Second class teak wood / Jack wood as per design, drawing, approval of Client/ KEL and the direction of engineering in charge.
od273859/2019_2020 : Supply testing and commisioning the following type 10 Nos CCTV unit with all accessories - HONEYWELL HWCHABC2005PI 1080p Bullet Camera Fixed Lens 3pt6 mm, HONEYWELL 16 CHANNEL 1080p DVR , WD 4 TB HARD DISK, 0 AMPS POWER SUPPLY, BNC connector (MX), DC Pin Connector, RG 59 Cable supply, 4U Rack with PDU, LG 18.5 Display, as per design, drawing, approval of Client/ KEL and the direction of Engineer in charge.
od273864/2019_2020 : Distribution Board : Supply, erection, earthing, testing and commissioning of the following MOB DBs Metal double Door powder coated including all interconnections and accessories like bolts, nuts and associated civil works. MCB DBs shall have comprising as follows: Double door- Concealed in wall. Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. IP 52 for indoor IP 54 for kitchen and laundry panels. IP 55 for outdoor . All MCB's used for protection of resistive and lightly inductive load shall be type "C"characteristic and inductive (motor) load shall be of type "B" characteristic and discharge lamps and UPS etc. shall be of type D characteristic. LDB -8W DP MCB DB incoming 63A D.P RCCB, 63A ISOLATER, 10A MCB 24 nos etc.
od273865/2019_2020 : Supply Laying, Testing and Commissioning of L& T made metering box with single phase Kwh meter class 1 with all the supporting accessories etc.complete as per approved design and direction of Engineer at site.
od273870/2019_2020 : Supplying and installation of following sizes of 1200 mm sweep. 5 star rated ceiling fan, with double ball bearing, Aluminium pressure die cast body with Aluminium blades, canopies, hanging Shackle, 30 cm down rod and without speed regulator suitable for 240V 50Hz, AC supply confirms to IS 374/1979 as required complete. (Make crompton- High speedor equivalent approved make)
TOILET BLOCK
9.141 : Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (±0.2mm), made out of single piece extruded PVC profile, with mitred cut joints and with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm, including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100 mm long anchor fasteners complete, all as per manufacturer's specification and direction of Engineer-in--charge. Make: Sintex with IS. (If change in specification, item may be treated as extra).
9.142.2 : 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded solid PVC ( ±0.2 mm) thick, having styles & rails (except lock rail ) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinges side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm x 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm x 100 mm of cross section size 35 mm x 17 mm s 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm x 35 mm, out of which 95 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineer-in-charge.Decorative finish (wood grained finish). Make: Sintex with IS. (If change in specification, item may be treated as extra).
21.1.2.3 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micorn)
4.1.2 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Make with IS.
od272516/2019_2020 : Providing and fixing wall mounting European water closet with seat cover (white colour), seat cover&slim concealed cistern , installation kit and drain pipe connection set for wall hung WC including control plate moon design all chrome or equivalent of approved shape with'P' trap, of removable soft matching seat cover , fixing of the above closet with stainless steel rack bolt (seam bolt) white cap etc. complete with supply of brass pan connectors, noise reduction gasket and necessary fasteners. Providing water and soil connections to the closet, together with cutting and making good the walls and floors wherever required, quality and brand as approved by the consultant, etc. complete. Providing and fixing WC-connection socket with lip (Quality controlled in accordance with DIN) Make: Kohler/ Equivalent (For rooms)
od272521/2019_2020 : Supplying and fixing CP Health Faucet superior quality including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. Make: Kohler/ Equivalent
od272524/2019_2020 : Providing and fixing Table top wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require Make: Kohler& Equivalent.
od272531/2019_2020 : Providing and fixing CP Towel Ring fixed with SS screws on to the toilet Approved Make Make: Kohlerƒ Equivalent.
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
50.18.9.2.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints as per direction of Engineer in Charge.20 mm dia 12 Kgf/cm2
50.18.9.3.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge 25 mm dia 12Kfg/cm2
50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
od273302/2019_2020 : Supply Laying, Testing and Commissioning of following 1100V XLPE A2XFY (XLPE insulated Armoured Aluminium)IN existing trench ,cable trays (Note : Inclusive of supply of Anchor Fasteners, straight through joints and necessary 1.5mm thick GI Flat, clamps shall be included in the laying cost).3C x 16Sq.mm XLPE Al.Ar. Incl excavation, 50mm G.I Pipe ,straight through joints if required
od273313/2019_2020 : CABLING - Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required - 4 core 10 sq mm with factory made clamp and 25mm PVC pipe as per approved design and direction of Engineer at site.
od273558/2019_2020 : Providing and fixing LED Tube set of 20W including all material and labour charges etc.complete. Make: PHILIPS/ LEGRAND
od273575/2019_2020 : Supplying and fixing following complete Cast Iron 2.5 mtr height ornamental pole , minimum weight 110kg, including the cost of conveying, loading, unloading, erection charge ,foundation bolt, plate, 2.5sqmm wire, etc all complete as per approved design with prior sample approval and . as per the direction of Engineer in charge. Make: PHILIPS/ LEGRAND
od273579/2019_2020 : Supplying and fixing 225x380 mm Post top Light (Classic Medium. Clear Diffuser. Material: Resin Moulded in black ) with 15w Bulb etc all complete as per approved design with prior sample approval and . as per the direction of Engineer in charge. Make: PHILIPS/ LEGRAND
ELECTRIFICATION WORKS
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.22.5 : Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.180 mm X 100 mm X 60 mm deep
1.23.3 : Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch
1.23.5 : Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.
Note: Make of Water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe: Supreme, Finolex or eq. with IS and all fittings with IS.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
Cable Glands & Sockets - REPUTED MAKE , Cosmos
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
Push Button- L&T, Schneider, Rishabh
Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
Bankers Construction
CUBIX INFRASTRUCTURES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_518456.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .