Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.0 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹91.6 L+₹2.6 L (2.88%)Rejected-Finance 1630 SECTOR 7 C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | L2 | Rejected-Finance High bid value | |
| 3 | L3₹92.9 L+₹3.9 L (4.38%)Rejected-Finance 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L3 | Rejected-Finance High bid value | |
| 4 | L4₹94.8 L+₹5.8 L (6.47%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L4 | Rejected-Finance High bid value | |
| 5 | L5₹1.2 Cr+₹35.5 L (39.9%)Rejected-Finance H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | L5 | Rejected-Finance High bid value |
Tender Value
₹87 L
EMD Value
₹1.6 L
Closing Date
24 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ Chief Engineer Shillong Zone
HQ Chief Engineer Shillong Zone, SE Falls, Shillong, Pin-793011
ADDN/ALTN REPLACEMENT OF BER EQPT AND ALLIED WORKS UNDER GE SILCHAR
2022_MES_505694_2
CESZ/SIL/27 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Silchar
As per tender documents
2 documents required · 2 mandatory
₹1,000
GE SILCHAR
₹1.6 L
Yes
31 Mar 2022
5 Mar 2022
26 Mar 2022
5 Mar 2022
24 Mar 2022
12 Mar 2022
5 Mar 2022 - 8 Mar 2022
90 days
Amount
NOTE (Applicable for all items):- The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' BOQ
M&L for Sub main wiring with two run of FRLS PVC insulated unsheathed multistranded copper conductor of nominal cross sectional area 6.0 Sqmm alongwith one run of FRLS PVC insulated unsheathed multistranded copper conductor of nominal cross sectional area 6.0 Sqmm as earth continuity conductor drawn through PVC conduit complete all as specified and directed by Engineer-in-charge. NOTES :- (a) Two runs of cable, one run of earth wire with one run of PVC conduit/casing shall be measured as one length. (b) All the incoming and outgoing cable should be connected through proper lugs and socket as per site requirements.
M&L for Sub main wiring with two run of FRLS PVC insulated unsheathed multistranded copper conductor of nominal cross sectional area 4.0 Sqmm alongwith one run of FRLS PVC insulated unsheathed multistranded copper conductor of nominal cross sectional area 4.0 Sqmm as earth continuity conductor drawn through PVC conduit complete all as specified and directed by Engineer-in-charge. NOTES :- (a) Two runs of cable, one run of earth wire with one run of PVC conduit/casing shall be measured as one length. (b) All the incoming and outgoing cable should be connected through proper lugs and socket as per site requirements.
M&L for Sub main wiring with two run of FRLS PVC insulated unsheathed multistranded copper conductor of nominal cross sectional area 2.5 Sqmm alongwith one run of FRLS PVC insulated unsheathed multistranded copper conductor of nominal cross sectional area 2.5 Sqmm as earth continuity conductor drawn through PVC conduit complete all as specified and directed by Engineer-in-charge. NOTES :- (a) Two runs of cable, one run of earth wire with one run of PVC conduit/casing shall be measured as one length. (b) All the incoming and outgoing cable should be connected through proper lugs and socket as per site requirements.
Supply and fix single pole and neutral encloser with a two pin and earth plug and socket with one single pole MCB 16/25 Amp complete all as specified and directed by Engineer-in-charge
Supply and fix Plug(Top) 16/25 Amps 2P+E suitable for metal plug and socket complete all as specified and directed by Engineer-in-charge
Supply and fix Plug(Top) 16 Amps 3 pin (PNE) suitable for 15 Amp socket complete all as specified and directed by Engineer-in-charge
Supply and fix PVC rectangular box of mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 150x100x50mm deep complete all as specified and directed by Engineer-in-charge
Supply and fix switch socket combination 5A/16A, 5 in 1 flush type complete all as specified and directed by Engineer-in-charge
Supply, install, testing, commissioning and balancing of floating barge made out of MS steel plate, Angle iron along with super structiure suitable for hosing two Split casing electric driven centrifugal pump set of capacity 50 HP alongwith foundatioin of suitable size and flooring (plateform) of size 5x7 meter complete with provision of suction and delivery hole in the body structure with steel door, steel window, steel railing and stair case, including provision of manhole/inspection box on both sides of body structure for both pontoon duly painted with anti corrosive black bituminous paint in the pontoons and sky blue paint to the body and camouflaging paints of green and white on the roof top after de-galvanizing including all accessories and point wiring all as specified and directed by Engr-in-CHarge.
Supply, instal, testing commissioning of horizontal split casing electric driven centrifugal pump of discharge capacity 140 cum m/hrs at 50 mtr head, multi stage, 150mm dia suction and 150mm dia delivery, coupled with 3 phase electric induction motor of 50 HP/37KW, 415 Volt, RPM 1450 totally enclosed fan ventilator type complete cast iron impellers and stainless steel shaft (coupled with flexible coupling) inclusive brass frame with min 50 Sqmm size of stranded copper wire copper lugs at both side of electric connection, as per manufacturer instruction complete all as specified and directed by Engineer-in-charge.
Supply and fix heavy duty armoured flexible corrugated rubber suction hose pipe of size 150 mm (bore) having both end heavy duty MS flange of suitable size complete all as specified and directed by Engineer-in-charge. (Note: Maximum length of one piece of pipe should not be more than 6 meter with both end having MS flange)
Supply, install , testing and commissioning of outdoor LT distribution feeder pillar box pedestal type (CPRI approved and with certification by ERDA for IP 65) of suitable size, factory made (tested as per IS) totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear, made out of 3.15mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and Copper bus bar of 400 Amps, 415 volts, 50 Hz, 3 phase and 4 wired system, independently housing for each control switch gear and indicating lamps with & including busbars made of copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours. Bus bar shall be properly supported/mounted on epoxy insulators. All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips. Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting/fixed the pillar box in floating barge including suitable Nut-bolts system/Welding complete. Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply. with the following items including supply and fixing with MS channel 75mm x 40mm x 5mm duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer for fixing the feeder piller box to foundation complete all as specified and directed by Engineer-in-charge. :- In coming :- (i)MCCB 4 Pole,415 V, Adjustable type, 160 Amps, breaking capacity 16 kA, Ics=100%Icu :- 01 No Contd.to item No 12.1
Supply, install testing & commissioning of electric driven vertical turbine pump of discharge head 15 mtr, 1460 RPM, 4 stage bowl brass impeller BRZ, line shaft SS-410, impeller shaft SS-410, shaft sleeve SS-410, bpwl bearing as per standard, column pipe-mild steel flange end (MS), depth of well considered 20 mtr with electric induction motor, vertical hollow shaft, SPDP, squirrel cage induction motor, 30HP/22 KW, 1500 RPM frame size SVH-180, 415 + 50Hz, 3 Phase AC with 35 Sqmm size of copper wire for electric connections as per manufacturer instruction & directed by Engr-in-Charge complete all as specified and directed.
Supply and Fix MS pipe 'C' Class, Heavy duty conforming to IS-1239, Part-I (2004) including cutting for suitable size as directed, specials Tread with sockets or heavy duty MS flange, MS Nut-Bolts on both end for nominal dia 150 mm all as specified and directed by Engr-in-Charge. [Note: Max length of one piece of pipe should not be more than 1.8 metre (6 feet) having both the end heavy duty MS flange with min 6 Nos of hole for nut-bolts] complete all as specified and directed by Engineer-in-charge.
Supply and install electrical induction motor vertical type 3 HP, 3Phase, 440 Volt 50Hz.complete all as specified and directed by Engineer-in-charge.
All as per Srl Item No 15 here-in-before but for 1.5 HP.
All as per Srl Item No 15 here-in-before but for 1 HP.
Supply and fix Star delta Starter fully automatic suitable for 415 V AC for 30 HP motor of VT pump with single phase preventor complete all as specified and directed by Engineer-in-charge.(Model No : MU-G40 FASD(with wideband coil) of make L&T cat No CS90908 or equivalent in list of makes)
Supply and fix DOL Starter suitable for 415 V AC for 3HP motor pump-set complete all as specified and directed by Engineer-in-charge.(Model No : MF1 three phase starter of make L&T cat No SS97210O or equivalent in list of makes)
Supply and fix DOL Starter suitable for 415 V AC for 2HP motor pump-set complete all as specified and directed by Engineer-in-charge.(Model No : MF1 three phase starter of make L&T cat No SS97210O or equivalent in list of makes)
Supply and fix CI foot valve suitable for 150 mm dia pipes complete all as specified and directed by Engineer-in-charge.
Supply and fix Sluice Valve flange of class PN-1.6, brass spindal of size 150mm, ISI marked heavy duty for DI pipe confirming the testing standerd as per IS : 14846 and fixed completely in location all as specified and directed by Engineer-in-charge.
Supply and fix Non Return Valve flange of class PN-1.6 of size 150mm, ISI marked heavy duty for DI pipe confirming the testing standerd as per IS : 14846 and fixed completely in location all as specified and directed by Engineer-in-charge.
Supply and fix high quality steel rope with PVC coated of size 25mm for holding the river barage complete all as specified and directed by Engineer-in-charge.
Supply and fix high quality 'U' clamp with nuts of size 25mm for holding the river barage complete all as specified and directed by Engineer-in-charge.
M&L for Earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6 mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level, with top edge of earth plate at a depth not less than 1.5 metre. below normal ground level , connected to galvanised iron strip of size 32 X 6 mm earth lead by means of bolts, nuts and washers of galvanised iron , earth lead strip protected by means of 40 mm bore dia light grade GI pipe up to switch board / panel board and 20 mm bore galvanised iron pipe medium grade for watering with GI funnel and wire mesh , all as specified and shown in MES schedule Electrical Plate No:-3 of SSR Part I, including excavation and earth work in any type of soil , PCC 1 : 3 : 6 type C1 in chamber , RCC 1:2:4 type B1 50 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, and provision of 6 mm dia MS hook, Charcoal and common salt in alternate layers complete and testing the earth resistance and writing on the chamber by paint complete all as specified and directed by Engineer-in-charge.
M&L for Earthing complete with Copper plate Electrode of size 60 Cm X 60 Cm X 3.15 mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level, with top edge of earth plate at a depth not less than 1.5 metre. below normal ground level , connected to copper strip of size 20 X 3 mm earth lead by means of bolts, nuts and washers of galvanised iron , earth lead strip protected by means of 40 mm bore dia light grade GI pipe up to switch board / panel board and 20 mm bore galvanised iron pipe medium grade for watering with GI funnel and wire mesh , all as specified and shown in MES schedule Electrical Plate No:-3 of SSR Part I, including excavation and earth work in any type of soil , PCC 1 : 3 : 6 type C1 in chamber , RCC 1:2:4 type B1 50 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, and provision of 6 mm dia MS hook, Charcoal and common salt in alternate layers complete and testing the earth resistance and writing on the chamber by paint complete all as specified and directed by Engineer-in-charge.
Supply, laying & testing cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm 3.5 Core complete all as specified and directed by Engineer-in-charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m but n exc 3.0 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m but n exc 3.0 m in depth and getting out in soft/loose soil.
Returning filling in including spreading, levelling, watering well ramming in layers not exc. 25cm thick complete all as specified and directed by Engr-in-Charge.
Removing excavated material(Soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for concrete as in foundations of pumps and machinery/copping of electric pole type B-1, 1:2:4 with 20mm graded aggregate complete all as specified and directed by Engr-in-Charge.
M&L for plastering 15mm thick in cement mortar (1:4) on fair face of brick masonry (Brick piller) or concrete surface and finishing the surface even and smooth without using extra cement.
M&L for MS clamps, angle, MS flat iron and nuts, Bolts and washers including necessary welding work complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of silent type Diesel Engine driven Generating set with sound proof acoustic enclosure (canopy CRCA sheet of 2mm thickness and noise level below 75 decival/M) and provison of exhaust fan inside the canopy to control the noise level as per limit of central pollution control board and including AMF panel 125 KVA, 3 phase , 415 Volts, 1500 RPM, 4 wire, 50 Cycle and power factor 0.8 complete all as specified and comprising of the following with set of tools and two years maintenance spares as recommended by the manufacturer. (a) Prime Mover (Engine):- As per IS:10001,suitable for driving 125 KVA alternator, brushless self excited and 4-Cylinder engine turbo charged water cooled complete under NTP condition with provision for 10% overload for 1hr on continious 12hr (Total 13 hour) running and common base plate frame engine standard instrumental panel, self exciting and self regulating control panel with accessories , self starter 12 volts with battery 180 AH and battery charging unit SCR type, battery cable leads , exhaust pipe with cladding by asbestos rope, sound proof canopy as per CPCB norms etc. Diesel engine set as per IS 10001 with inbuilt electronic speed governer with relay with inhouse canopy mounted fuel tank not less than 12 hours running capacity confirming to BSS frame pedestal support with anti vibration pad including RCC foundation with min hieght 45cm for DG set alongwith the following standard accessories:- (i) Fly wheel to suit coupling (ii) Flexible coupling with guard, bolts and nuts,etc.for exhaust system (iii) Dry type air cleaner filters (iv) Radiator with guard and radiator fan (v) Fuel pump complete with fuel injection systems (vi) Electronic speed governor (vii) Fuel filter (viii) Lub oil filter (ix) Self starter 12 Volts DC (x) Exhaust silencer industrial type with pipe 3 m long (xi) Instrumental panel with the following:- (aa) Self starting key / switch on relay control panel (ab) Lubricating oil pressure guage (ac) Battery charging ammeter. (ad) Hour meter and RPM indicator (ae) Lub oil temp guage (af) Water temp guage (xii) Turbo charger (xiii) Lub oil pump (xiv) Lub oil cooler assembly (xv) Dynamo 12 V for charging of battery (xvi) Control including charging system panel with MCCB 125 Amps 4 Pole 35 KA -01 No. (xvii) Provison of light inside the canopy. (xviii) Emergency stop push button outside the container. (xix) Low oil pressure protection cutoff. (xx) High temperature protection cutoff. (xxi) Overload protection cutoff. Contd to item No 38.1
Contd of item No 38.... (b) Alternator:- As per IS:13364, self exited, self generated balanced 415 volts, 3 phase, 50 Cycles per second, 125 KVA at 0.8 PF or nearest in higher capacity, 1500 RPM, star connected, 4 wire, drip proof enclosure, air cool with radial fan mounted on rotor, screen peotected, self ventilated enclosure as per IS 4722/IS 2613 with drip proof enclosure with damper winding on pole faces, static automatic voltage regulator to provide voltage regulation 1% and harmonic factor bettr than 2% from no load to full load from 0.8 to unity power factor and insulation of H-class and above as per standard practice. (c) AMP Panel:- In-Built with DG Set AMF Panel suitable for desired operation.
M&L for shifting of existing BER DG set 110KVA installed at main power house to MES MT yard with the help of hydraulic crane of suitable capacity including dismantling of cable from electric panel complete all as specified and directed by Engineer-in-charge.
SAGGI ELECTRIC COMPANY
Rajan Traders
PURBANCHAL BUILDERS
M/S. SUBHAS CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .