| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-AOC 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹1.5 L+₹21,864 (17.4%)Rejected-Finance | L2 | Rejected-Finance Other than L1, hence rejected | |
| 3 | L3₹1.6 L+₹30,803 (24.5%)Rejected-Finance | L3 | Rejected-Finance Other than L1, hence rejected |
Tender Value
Refer Docs
EMD Value
₹2,600
Closing Date
28 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Naya Raipur
AGE (I) Naya Raipur Military Engineer Services C/O HQ COSA Near International Cricket Stadium Atal Nagar, Distt-Raipur (CG) Pin - 492101
REPAIRS TO PERIMETER LIGHTS, CABLE AND PANEL BOARDS AT KOTA RAIPUR UNDER AGE (I) NAYA RAIPUR
2020_MES_373817_1
8400/255/E8
Open Tender
Civil Works
Item Rate
120 days
AGE (I) Naya Raipur
Please refer tender documents
7 documents required · 7 mandatory
₹300
AGE (I) Naya Raipur
₹2,600
16 Feb 2021
1 Sept 2020
1 Oct 2020
1 Sept 2020
28 Sept 2020
15 Sept 2020
60 days
Amount
Disconnecting and taking down street /security light fitting HPSV /MH/FLOODELIGHT /T-5 (2x24)/ etc of any size /capacity /make from the pole /Bldg for repair /Replacment of UNSVspare parts such as lumineire complete with acessores suitable 40 mm dia street light fitting etc after testing, cleaning the fitting internally and externally and replacement of unserviceable wiring with 1.0sqmm PVC insulate copper wire, nuts, bolts, screws and fixing the light fitting in original position on wall/pole/santry post/top of building including necessary electrical connection complete all as specified and directed Note rate deemed to included the T&P used for this purpose bring by the contractor.
Taking down old and Supplying, fixing and testing PVC insulated and PVC sheathed,round, 3 core, copper conductor cable, 1.5 sqmm cross sectional area complete all as specified and directed.all as specified and directed by engr-in-charge
M&L in repair for LED street light fitting made out of pressure dia cast aluminium, with IP-66 or IP-65 protection including LED lamps suitable for 45 watts, 240 volts, AC, 50 Hz intergral LED street light luminaire comprising of epoxy powder coated enclosed with glass in frame 45 watt BSLST 45 LED mounted on MCPCB complete acessories all as specified and as directed by Engr-in-Charge
Refixing of serviceable steet light fitting down from item No 1 with rectified the same with minor repair as change of connection wire remove carbon and making new connection and replace the defective part and hanging at specified place as pole/building/minor all as directed and specified by engr-in-charge
Excavation in trenches in any type of soil, n. exc. 1.5m wide and n. exc. 1.5m deep and getting out for laying of cables/pipes etc including forming bottom surfaces to the required level/slope complete, all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick in any type of soil complete, all as specified and directed..
Removal of surplus excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above starting point complete, all as specified and directed..
Supply and spreading clean and dry fine sand free from sharp material (unwashed) laying in trenches around the cable for cushioning complete, all as specified and directed.all as specified and directed by engr-in-charge
M & L brick protection cover over cable of “Sub class 'B' laid dry over cable (length of brick shall be laid across the length of cable) complete, all as specified and directed.all as specified and directed by engr-in-charge
Taking out carefully existing unserviceable LT cable from pole, panels and trenches any size any capacity and removing connection from existing switch board/ over head line etc complete.all as specified and directed by engr-in-charge
Supply/Laying or fixing or passing through pipe, jointing and testing 1100 volt grade XLPE insulated armoured heavy duty PVC insulated, PVC sheathed armoured electric cables with aluminum stranded conductor, complete all as specified and as directed for the following cross sectional area and core :-
(a) 16 Sqmm 4 Core
Taking down and Supply and laying galvanised iron pipe “Light Grade” in trenches, under floors, roads, along poles for protection of cables with all necessary fittings , including sealing ends complete all as specified and as directed for the following dia bore :-
(a) 40 mm dia bore
Filtration heating and dehydrating of drained out transformer oil to achieve dielectric strength not less than 40 KV(V.M.S) at 4mm gap complete all as specified and directed
Supply heating and filling of transformer oil EHV grade having dielectric strength not less than 40 KV (RMS) of 4mm gap low viscosity in transformer, confirming to IS -335 of 1983 all as directed
Taking down Air break switch of any type and capacity
Supply and fixing of triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from gorund level for current rating upto 200 ampds HT 11 KV outdoor type gang operated air break switch suitable for horizontal or vertical mounting fixed type complete 200 amps rating and with locking arrangement flat iron clamp 50mmx6mm incl MS chanel of suitable size and length for fixing GOD incl bolts, nuts and washer complete all as specified and directed by engr-in-charge
M&L for disconnecting existing HT/LT connection from transformer and drain out oil up to working level for replacement of Low tension bushing insulator with stud, nut bolts and gasket etc including opening the transformer and refixing including changing cover gasket, making good connections and testing all as specified and directed for the following transformer.Note : - (i) Item rates deemed to include for proper storage or drained transformer oil and refilling.
All as per item above but for transformer of capacity 100 KVA .all as specified and directed
M&L in repair for maintenance of transformers 11KV/433 volts by disconnecting existing HT/LT connection drain out oil up to working lavel all as specified, checking and correcting the distortion and looseness of the winding on the core, checking and correcting the slackness of the core and tightening nuts, bolts, tightning neutral of the transformer from inside refilling in transformer, positioning core properly including testing for insulation resistance after completion of the job for transformers of following capacities:- Note: - Item rates deemed to include for proper storage of transformer oil during the work and dehydration and testing for dielctric strength before refilling. (ii) Item shall be operated before complete filtration and dehydration of transformer oil.
Taking down and M&L for removing the damaged HT coil from core carefully & rewinding of HT/LT coil with same gauge of exsisting coil with similar class of exsisting insulation all as specified & directed by Engr-in-charge capacity 100 KVA transformerall as specified and directed
Taking down and M&L for removing the damaged LT coil from core carefully & rewinding of HT/LT coil with same gauge of exsisting coil with similar class of exsisting insulation all as specified & directed by Engr-in-charge capacity 100 KVA transformerall as specified and directed
Earthing with Galvanised Iron Earth Plate Electrode 600X600X6mm size buried directly in Ground vertically at a depth not less than 2.25 METRE below Ground Level with the Top Edge of Earth Plate at a depth not less than 1.50 METRE below Ground Level connected to GI Wire 4 mm as Earth Lead by means of Bolts, Nuts, Check Nuts and Washers of Galvanised Steel, Earth Plate Electrode surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers not exc. 150mm thick, Aluminium Strip protected with and including Galvanised Iron Pipe 40mm Bore (dia) Light Grade, upto 1.0 METRE above the Floor Level of the Building where Main Switch/DB situated including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Agg-regate) and RCC Cover of size 540X540X50mm in RCC 1:2:4 (20mm Graded Stone Aggregate) rein-forced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and Testing on completion including Taking down Unserviceable Earthing, complete all as specified and as directed.
Dismantling Danger notice plate of any type all as specified and directed by engr-in-charge
Disc Type Insulator, Single, Porcelain, Vitreous 145mm High and 255mm dia Ball and Socket Type White, Brown or Green, in ‘two Disc in series Assembly’ for tension with Tension Clamps for Conductors, Working Pressure 11000 Volt, complete .all as specified and directed by engr-in-charge
Danger notice plate of 1.6 mm thick mild steel sheet vitreous white ,with letters ,figures and fixed with ms clamps bolts and nuts of size approved size for HT 11000 of size 25cmx20cm confirming to IS-2531.all as specified and directed
Taking down and S&F aluminium strip 25x3mm all as specified and directed
Total contracts sum shall be calculated after deduction of schedule of credit amount of Rs. 8920.00
FIRST SOLAR
M/S INDIA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .