Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC VILL KISHANPURA P O JAMNIWALA TEHSIL PAONTA SAHIB DISTRICT SIRMOUR HP | PAONTA SAHIB | SIRMOUR | HIMACHAL PRADESH | L1 | Accepted-AOC Accepted | |
| 2 | L2₹18.4 L+₹72,345 (4.10%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹19.6 L+₹2.0 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Rejected |
Tender Value
₹18.0 L
EMD Value
₹34,500
Closing Date
8 Aug 2023, 10:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
HP City Transport and Bus Stand Management And Development Authority Tutikandi Shimla -4
SH Providing E.I work therein
2023_BSMDA_76777_2
HPBSMDA/EE/(2)2021 Tenders Vol-III
Open Tender
Electrical Works
Item Rate
590 days
Kullu
Please refer Tender Document
9 documents required · 9 mandatory
₹590
HP BSMDA Tutikandi Shimla-4
₹34,500
18 Sept 2023
26 Jul 2023
8 Aug 2023
27 Jul 2023
8 Aug 2023
27 Jul 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm (One point five square milimeter) FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm (one point five square milimeter) FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light/ power plug with 2X4 sq. mm (Two into four square milimeter) FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm (four square milimeter)FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm (Four into four square milimeter) FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm (four square milimeter) FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 X 1.5 sq. mm (two into one point five square milimeter) + 1 X 1.5 sq. mm (One into one point five square milimeter) earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2 X 6 sq. mm (two into six square milimeter) + 1 X 6 sq. mm(one into six square milimeter) earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2 X 10 sq. mm (two into ten square milimeter) + 1 X 6 sq. mm (one into six square milimeter) earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 4 X 10 sq. mm (four into ten square milimeter) + 2 X 6 sq. mm (two into six square milimeter) earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 4 X 16 sq. mm (four into sixteen square milimeter) + 2 X 6 sq. mm (two into six square milimeter) earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 50 mm (fifty milimeter)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 200 A, 16 KA,TPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Double pole. Cat-A. 63 Amps.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Double door-4 way
Earthing with G.I. earth pipe 4.5 metre (Four point five meter) long, 40 mm (Forty milimeter) dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required:- 25 Liter capacity water heater (Cat-A)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required: Ceiling Fan 1200 mm (Twelve hundred milimeter) sweep Approved Make Usha Swift/Bajaj Ultima
Providing and installation exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: Exhaust Fan, Heavy duty, 300 mm (Three hundred milimeter) sweep Approved Make Crompton/Havells
Providing and installation of following type of surface mounting square/round type LED panel Light with aluminium die cast housing in white finish with anti glare polycarbonate diffuser and seprated energy efficient constant current, non-integral, electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing etc. as required: of Approved Make Havells/Wipro/Bajaj Square/round LED Panel Light 18/20W Surface 1'X1'
Providing and installation of following type of surface mounting square/round type LED panel Light with aluminium die cast housing in white finish with anti glare polycarbonate diffuser and seprated energy efficient constant current, non-integral, electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing etc. as required: of Approved Make Havells/Wipro/Bajaj Square LED Panel Light 36W Surface 2'X2'
Providing and installation of following type of LED batten with aluminium housing, anti glare polycarbonate diffuser and energy efficient constant current, integral electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including mounting clamps, connections, testing etc. as required: of Approved Make LED Batten Light 20W Havells/Wipro/Bajaj
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Armoured cable 6 sq. mm (Six square milimeter) (twin core)
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Armoured cable 95 sq. mm (Ninty five square milimeter)(3.5 core)
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required. Armoured cable 95 sq. mm (Ninty five square milimeter) (3.5 core)
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm (five centimeter) variation made from (50 mm x 50 mm x 6 mm thick) (fifty milimeter into fifty milimeter into six milimeter) M.S. angle iron frame, covered with 1.6 mm (one point six milimeter) thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm (fifty milimeter into six milimeter) thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm (fifty milimeter into fifty milimeter into six milimeter) thick M.S. angle iron each 60 cm (sixty centimeter) long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 (one isto two isto four) cement concrete plat-form of suitable dimensions 15 cm (fifteen centimeter) high from ground level and 45 cm (Forty five centimeter) thick. The cubical pedestal shall be 15 cm (Fifteen centimeter) from the top of cement concrete plat-form:- 450 mm (Four hundred fifty milimeter) deep (nominal)
S/F LED Bulk head 10 watt (6500k) of syska or its equivalent approved make of complete with connections etc
Supplying and fixing sheet metal bus-bar chamber suitable for 100 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm (Three hundred milimeter) & cross-sectional area (25.4mmx3.17mm), (Twenty five point four milimeter into three point seventeen milimeter) enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx400mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-
Supplying and fixing sheet metal bus-bar chamber suitable for 200 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm (Three hundred milimeter) & cross-sectional area (25.4mmx4.75mm), (Twenty five point four milimeter into four point seventy five milimeter) enclosure made from 1.6 mm (one point six milimeter) thick M.S. sheet having overall dimensions (380mmx450mmx150mm) (Three hundred eighty milimeter into four hundred fifty milimeter into one hundred fifty milimeter) nominal with all accessories including connections, earthing the body etc. as required:-
Supplying and erection of 3 stepped steel tubular swaged and welded pole of suitable length and dia. to be fixed up to a required planting depth below G/L in a hole of excavation about 30 cm (Thirty centimeter) dia. and of suitable depth, to be filled in up to 15 cm (Fifteen centimeter) below G/L with 1:3:6 (one isto three isto six ) cement concrete and there above plinth with 1:2:4 (one isto two isto four) cement concrete up to a height of 45 cm (Forty five centimeter) from G/L. The radial thickness of the plinth above G/L should not be less than 6.35 cm (six point thirty five centimeter) and sufficient to completely flush a 180 mmx100 mmx 45 mm (one hundred eighty milimeter into one hundred milimeter into forty five milimeter) deep, glass filled Nylan F.R. grade box for housing a 16 Amp. MCB, the outer surface of the plinth to be finished with 1:3 (one isto three) cement plaster 6 mm (six milimeter) thick, the fuse-box shall have a water tight cover, including painting of pole with two coats of approved color, brand and manufacture of paint over a priming coat complete in all respects as required:- (b). Overall length 8 meter, with planting depth 1.5 m, (one point five meter) length of sections 4.5 m, (Four point five meter) 1.75m (one point seventy five meter) and 1.75m (one point seventy five meter) (bottom, middle and top respectively), outer dia and thickness of sections 127mmx4.5mm, (one hundred twenty seven milimeter into four point five milimeter) 101.6mmx3.65mm (one hundred one point six milimeter into three point sixty five milimeter)and 76.1mmx3.25mm (seventy six point one milimeter into three point twenty five milimeter) (bottom, middle and top respectively) with approximate weight 84 Kg.
New generation energy Saving and Environmental friendly long life LED street light made up of pressure die cast alminium housing with high power LED as Lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07 with 10Kv Built-in Surge Protection Device. ENDURAPEARLPLUSSL90WLED757PASYT OPCASTHO
Supplying and erection of street light bracket made of G.I. pipe 'A' class of suitable length and dia, the pipe bended to give an angle of 100 to 110 degree fitted with bolt & nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over priming coat complete in all respects as required:-
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required.
S/F of enclosure for 100 amp 4 pole MCCB
S/F of Exuast Fan shutter for 300 mm (Three hundred milimeter) Exaust fan
Providing and Installation of industrial wall Mounting Turbo force fan of Following Size motor I/E hang the same in position on the wall connection testing and commissioning with best satisfaction of enginner in charge. 450 mm (Four hundred fifty milimeter) Make Havells/Bajaj/Crompton
Providing and fixing MCCB 63 amp 2 pole 10 KA with enclosure for 63amp MCCB
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 A
P/F Energy saving environmental friendly long life exclusive innovative dia-cast alminium IP66 flood light suitable for highlighting architectural façade and general purpose lighting 150 watt Havells or its equivalent approved make Havells/Wipro
Supplying and fixing of Cubical type indoor type lower mounted fixed type M.S.C.R.C sheet panel for 12 compartment meter board Size 1850 (H) X 1900 (W) MM Cubical Pannal shall be febricated with 2mm thick CRCA steel sheet for load Bearing structure & 1.6/1.2 mm CRCA steel sheet for doors, covers & partation of the pannal and it required accessories locks, Gasket, Hinges, Cable ties and all other Miscellaneous items, the panel consisting of 100 amp 4p 25ka MCCB with O/L & S/C 1 Nos. Spreader Terminals 4p "CVS" 2. Nos, Extended Rotary Handle "CVS" 1 Nos, LED Indication Lamps R,Y,B 3 Nos, 6 amp 1p 10 ka MCB "ACTI-9" 3 Nos, Neutral Link 1 Nos. Outgoing B- Part:- 32amp 2p 10 ka MCB 8 Nos. Space for Chargable Electricity Energy Meter 12 Nos, Aluminum/ copper flat with crunnet densty of 1 A/SQ. MM in AL & 1.6 A/SQ.MM in CU. Along with all the required accessories for fixing and mounting. Busbars: Copper: For Phase:1 R X 20 X 03 MM. CU. or equal. For Neutral: 1R X20X03 MM. CU. or equal. For Earth: Bolted Earthing, the material used L & T or Schneider make.
ARUN KUMAR SHARMA
Digvijay Sharma
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .