Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC DURGAPUR GHANOODIH JHARIA DHANBAD DHANBAD 828111 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828111 | ₹16.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹16.9 L+₹76,938.85 (4.76%)Rejected-Finance AJANTA PARA NEAR SAI BABA MANDIR HIRAPUR | DHANBAD | DHANBAD | JHARKHAND | 826001 | ₹16.9 L+₹76,938.85 (4.76%) | L2 | Rejected-Finance L2 |
| 3 | L3₹17.8 L+₹1.7 L (10.5%)Rejected-Finance BASTACOLLA NEAR ATTA CHAKKI DHANBAD DHANBAD DHANBAD 828111 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828111 | ₹17.8 L+₹1.7 L (10.5%) | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹23,000
Closing Date
16 Mar 2026, 6:00 pmClosed
AREA MANAGER ENM
BASTACOLLA AREA VIKASH BHAWAN JHARIA DHANBAD
DEPARTMENTAL ESTIMATE FOR DIVERSION/ERECTION OF 11kV OVERHEAD LINE FROM SAHANAPAHARI TO BASTACOLLA COLLIERY UNDER BASTACOLLA AREA-IX
2026_BCCL_356167_1
BCCL/BA-IX/ENM/25-26/282 07/03/2026
Open Tender
Electrical and Maintenance Works
Percentage
21 days
BASTACOLLA AREA
Please refer Tender documents.
2 documents required · 2 mandatory
₹23,000
Yes
8 Apr 2026
13 Mar 2026
19 Mar 2026
13 Mar 2026
16 Mar 2026
13 Mar 2026
13 Mar 2026 - 15 Mar 2026
Erection of steel tubular or rail pole strut in cement concrete 1:3:6(1 cement : 3 coarse sand : 6 graded stone aggregate 40 mmnominal size ) foundation including excavation and refilling andsecured with holding clamps, bolts, nuts, etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height , complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required .
Supplying and erection of 11/3.3 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
Supplying and erection of 11 KV/3.3 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.
Supply of GI Wire 8 SWG
Erection of G.I. Wire No. 8 SWG including binding etc. as required.
Erection of cradle guard as required.
Erection of AB Switch 11KV 1240 A
Transportation of New Pole
Earthing with GI earth plate 600mm*600mm*6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7metre long etc with charcoal /coke and salt as required
Supply of AB switch 11kv 1240A
Dismantaling of 11kv over head line conductor,Iron material, Disc and pin insulator etc
Transportation of old dismentle pole
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
technical_369017.pdf
techsummary_369017.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.32 MB
BOQ_369017.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .