Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹47.3 L+₹1.7 L (3.69%)Rejected-Finance SARDARPURA 1ST B ROAD NEAR HANUMAN JI KA MANDIR JODHPUR RAJASTHAN 342 003 | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L2 | Rejected-Finance Rejected due to L2 | |
| 3 | L3₹47.9 L+₹2.3 L (5.03%)Rejected-Finance HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L3 | Rejected-Finance Rejected due to L3 |
Tender Value
₹46.3 L
EMD Value
₹92,560
Closing Date
4 Jan 2025, 6:00 pmClosed
Garrison Engineer (Army) No 2 Jodhpur
Military Engineer Services, Garrison Engineer (Army) No 2 Jodhpur, Multan Lines, Army Area Jodhpur -342010
PROVN OF CERTAIN SANCTIONED WORK AND SPECIAL REPAIR TO FLOOR , WALL TILING , JOINERY AND ELECTRIC WIRING WORK IN DINING HALL AND CHILDREN ROOM OF BLDG NO. P-91 INSIDE JOI UNDER GE (A) NO 2 JODHPUR
2024_MES_687597_1
8800/24-25/03/37/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (Army) No 2 Jodhpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (Army) No 2
₹92,560
Yes
15 Feb 2025
7 Dec 2024
6 Jan 2025
7 Dec 2024
4 Jan 2025
21 Dec 2024
7 Dec 2024 - 14 Dec 2024
Amount
Excavation in trenches n.exc 1.5 m wide & n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
M&L PCC 1:4:8 type D2 (40 mm graded aggregate) in foundation filling and mass concreteetc complete etc.all as specified and as directed.
M&L for brick work with fly ash bricks (old size bricks), straight or curved on plan exc 6mtr mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides of soffits (if any) of foundations and plinth beams and similar work etc; rough finish surfaces complete all as specified and as directed.
M&L for Form work to sides of concrete pillars, posts, struts, piers, columns and stanchion etc; rough finish surfaces complete all as specified and as directed.
M&L for Form work to sides and soffits of floor or roof RCC beam sides of lintel beam flat rough finish surfaces to receive the plaster, complete all as specified and as directed.
M&L for Form work to soffits of suspended slabs such as roof slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping), rough finish surfaces complete all as specified and as directed.
M&L for Form work to edges of concrete flats, floor and roofs not exceeding 20cm wide (horizontal or sloping), rough finish surfaces complete all as specified and as directed.
M&L for Form work to chullah hoods,chhajas through and similar items incl edges,surface rough finish surface to receive the plaster complete all as specified and as directed.
M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in foundations, including raft footings, foundations beams, plinth beams, bases of columns etc; complete all as specified and as directed.
M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc; complete all as specified and as directed.
M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in beams, lintel up to 1.5m clear span, lintel bands etc; complete all as specified and as directed.
M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in roof, landings, balconies, canopies and in shelves etc; complete all as specified and as directed.
M&L for providing RCC 1:1-1/2:3 type B1 (using 20mm graded stone aggregate) as in chhajas etc complete all as specified and as directed.
M&L for Reinforcement 10mm dia and over TMT bars cut to length, bent to shape required and binding with MS wire not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Reinforcement 8 to 10mm dia TMT bars cut to length, bent to shape required and binding with MS wire not less than 0.9mm dia in stirrups complete all as specified and as directed.
M&L for carrying out water proofing treatment for roofs in the following stages - (i) Rendering 10mm thick in 1:4 mixed with integral water proofing liquid all as per manufacturer's instructions over concrete surfaces finished even and smooth with out using extra cement. (ii) First coat of bitumen primer confirming to IS 3384 @0.300 Kg/ Sqm over plastered surafces (iii) Second layer of 3.0 mm thick APP modified polymeric membrane with centre core of Single non woven polyster reinforcement and having weight 3 Kg/ Sqm with mineral gravel finish on top complete laid with blown type bitumen grade 85/25 @ 1.20 Kg/ Sqm complete all as specified and as directed.
Supply only integral water proofing liquid ISI marked Make: Pidiproof LW
Returning,filling in,including spreading,levelling,watering and well ramming in layers not exc 25 cm each layer in hard/dense soil all as specified and directed.
Removing excavated soil n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point all as specified and directed.
M&L for 15 mm thick rendering on stone/ brick masonary wall surfaces in CM 1:4 finished fair and even all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:6 finished even without using extra cement over stone wall surfaces all as specified and as directed.
M&L for 10mm thick rendering in CM 1:3 on ceiling surfaces finished surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8 type D-2, (40mm graded stone aggregate) as in sub floor, sub bases, floor and paving etc; complete all as specified.
M&L for PCC 1:2:4 type B0 25 mm thick using 12.5mm graded stone aggregates as in sub floors/base floors under tiles as in levelling course etc all as specified and directed.
M&L for non skid ceramic coloured tiles of approved shade and pattern, 7 to 8 mm thick , area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm laid in floor, set and jointe (square/ rectangular) in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of approved shade and pattern of size 350x 250x7mm/ 450X350X7mm/ 300X450X7 to 8mm thick or any other nearer size as approved in vertical surface set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in CM 1:4 as in backing coat of tiles complete all as specified and as directed.
M&L for 16 -18mm thick granite (colour as approved) work (table rubbed and polished) in steps, shelves, jambs, pillars, window-cills, cooking platforms (vertical/ horizontal) and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 10mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed.
Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and fair without using extra cement including provision of construction joints complete all as specified.
M&L for fabrication of aluminium powder coated window any pattern & design (openable with hinges, sliding, tilt and turn, casement , fixed type, villa type, ventilators) fabricated with anodized aluminium rectangular or any type section in frame with approved design & patterns including provn of fixing galvanised mild steel wire cloth on the outer side of frame etc; fixed in position all as specified and directed. Note:- Glass pane & galvanised mild steel wire cloth shall be measured and paid separately.
S&F for figured glass, pin head type ordinary quality, 4mm thick, area of each pane not exceeding 0.5Sqm and glazing with aluminium beading in aluminium frame all as specified and as directed.
S&F Powder coated aluminium anodised deco grill weighing not less than 1.40 kg/ sqm and fixing necessary joining cleats/ frame etc; complete all as specified.
S&F of factory made solid panel PVC door shutters 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing S&F. Make : Rajshree Doors or equivalent as approved by GE.
S&F of solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing. Make : Rajshree Doors or equivalent as approved by GE.
S&F of 100 mm size PVC/ Stainless Steel (as approved by Engineer incharge) butt hinges , complete all as specified and as directed.
S&F of alluminium anodised handles 150 mm long fixed to windows, complete all as specified and as directed.
S&F Aluminium anodised, barrel tower bolts 150 mm long of extruded section and fixed , complete all as specified and as directed.
S&F Aluminium alloy, anodised, sliding door bolt 150 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and as directed.
S&F of 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide.
S&F of 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide.
S&F of 25mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide.
S&F Vitreous china under/over counter wash basin, white colour, oval shape, size 560x470mm including CP waste fittings coupling , 32mm bore size, bottle trap 32mm and angle iron brackets of required size and length etc and fixed over marble/granite or RCC plateform including necessery cutting accourding wash basin shape/ size etc; and making good disturbed surfaces to match with the existing complete all as specified.
S&F of low density polythene pipe (LDPE) of pressure rating 6 Kg per Sq.cm, 450 mm long, heavy duty with two sets of brass nuts & washers (one at each end) etc suitable for 15mm bore of pipe as in repair complete all as specified.
S & F Vitreous China Urinal, Half stall type,white with Urinal spreader for fixing with 15 mm dia pipe. (Minimum weight 60gms) including PVC connection , bottle trap 32mm complete all as specified and directed by Engineer-in-charge.
S & F Vitreous china urinal partition white of size 310x700 mm complete all as specified and directed by Engineer-in-charge.
S&F vitreous China wash down water closet pan (Pedestal Pattern), white including white plastic seat cover with mild steel CP hinging device, with health faucet and incl making connection to inlet flush pipe, & to 'P' or 'S' drain trap, incl supply of long special 'P' or 'S' trap fixed complete all as specified and directed.
S&F PVC 10 ltr. Cap. valveless syphonic action type, flushing cictern, low level, white/ coloured with inlet, ball valve, float and handle including brackets and connection to pipe etc. all as specified.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 142 gms.) all as specified and as directed.
S&F 15mm bore chromium plated two way bib taps, fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified.
S&F Bib tap,15mm bore, fancy type, brass chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F pillar tap, brass, 15mm dia, with capston heads, chromium plated, fancy type screwed down, high pressure, with or without lettered hot or cold, with long shank, screwed shanks and fly nuts, screwed for iron pipes or for wash hand basin all as specified and as directed.
S&F 15mm bore stop valve/ angle stop cock chromium plated, fancy type cast copper alloy, screwed down, high pressure, screwed both ends for iron pipe with long shank and cup complete all as specified.
S&F 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified.
S&F CP Grating doom 100 mm dia. (Minimum weight 40gms) complete all as aspecified and directe
S&F 100mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, laid in trenches or in floor etc; complete all as specified.
S&F 100mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, fixed to walls etc; complete all as specified.
S&F 75mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, laid in trenches or in floor etc; complete all as specified.
S&F 75mm bore pipe cast iron 'P' or 'S' trap, complete all as specified.
S&F 100mm bore pipe cast iron cowls, complete all as specified.
M&L cast iron up to 150mm bore fittings of Bends (any type, radious and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces, single branch, 'Y' junctions, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc; complete all as specified.
M&L 100mm bore cast iron pipes and fittings joints or connections are filled/ sealed properly by epoxy sealant of ISI mark or M-Seal (Make:- Dr Fixit) apply as per manufacturing instructions, complete all as specified.
M&L 75mm bore cast iron pipes and fittings joints or connections are filled/ sealed properly by epoxy sealant of ISI mark or M-Seal (Make:- Dr Fixit) apply as per manufacturing instructions, complete all as specified.
S&F for 100mm bore pipes stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall etc; complete all as specified.
Preparing new plastered surfaces and M&L for applying chalk whitening/ concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of Distemper oil Emulsion on new plastered surfaces all as directed by Engr in charge.
Preparing new plastered surfaces and M&L for applying concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of cement base paint on new plastered surfaces all as directed by Engr in charge.
Preparation of new plastered surfaces of ceiling etc. & applying three coats of lime white wash on ceiling complete all as specified.
M&L for cement concrete (1:4:8) type D-2 for 150mm dia pipe bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in complete all as directed and specified
M&L for Reinforced concrete pipes, of 150mm bore, class NP3, laid in trenches and jointed in cement mortar as specified complete with collars including all fixing connections complete all as specified.
M&L for PCC (1:3:6) type C2 using 40 mm graded stone aggregate as in surfaces channel and drain of man holes finishing surfaces even and smooth complete all as specified and as directed.
M&L for Jodhpur stone patti slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, laid dry as in manhole coveres, sizes as directed by Engineer incharge complete all as specified and as directed.
S&F 75mm bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, fixed to walls etc; complete all as specified.
S&F 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends with iron pipe complete all as specified and as directed.
Vitreous china squatting pan, Orissa pattern, size 580x440mm white/ coloured with integral foot rests including flus pipe and connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete all as specified and as directed.
S&F CP towel rail 450mm long fixed with and including CP brass screws and wooden/ plastic cleats complete all as specified and as directed.
S&F chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union suitable for 15mm bore pipe etc; complete all as specified.
S&F of galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified & as directed.
M&L for 100mm thick PCC 1:4:8 type D-2, (40mm graded stone aggregate) as in sub floor, sub bases, floor and paving etc; complete all as specified.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade as approved by GE , laid over 25mm thick compacted approved sand cushioned surface, joints filled by fine sand and compacting the top surfaces of paver blocks after laid etc of approved make all as specified and as directed.
M&L for factory made precast cement concrete solid blocks M-30 Grade, using 20 mm graded crushed stone aggregate as in kerb stones of any size (with plain or interlocking joints as directed) set in cement mortar 1:4 for path edgings etc; embedded in position including all necessary excavation, tamping ground arround blocks and removal of rubbish/ surplus soil etc., complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in kerbs or benching etc including necessary form work complete all as specified.
S&F in repair fiber-reinforced plastic (FRP) manhole cover with frames (any colour) of overall covered area not less than 0.55 sqm with clear opening not less than 0.36 sqm, any shape (round, square, rectangular etc;) overall weight not less than 25kg each and load capacity not less than 20 tones provided with safe and anti-slippery surface, fire retardant, Anti Corrosive, suitable locking system, and enable clear opening with provision of easy lifting hooks etc; with all necessary fixing arrangements complete all as specified and directed.
Cutting into existing manhole for connecting new drain pipe (150mm Internal dia of pipe), making good to pipe and rendering, cutting out existing benching for and forming brench chennel in cement concrete 1:2:4 type B-1 smooth finished etc; complete all as specified.
Dismantling glazed tiles/ kota stone/ terrazzo tiles any type as in dado/ skirting etc; including cement mortar bedding ( but not backing ) complete all as specifide.
Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and as directed
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4.00 sqm each and removing from site or to store as directed by Engineer incharge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each and removing from site or to store as directed by Engineer incharge.
Dismantling boarding of any description fixed in any position with nails, complete all as specified.
Complete removal of existing treatment by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl washing , rubbing down and stopping of distempered or painted surfaces and M&L for applying chalk whitening/ concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of Distemper oil Emulsion on old treated surfaces of walls complete all as specified and directed by Engr in charge.
Complete removal of existing treatment by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl washing , rubbing down and stopping of distempered or painted surfaces and M&L for applying concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of cement base paint on old treated surfaces of walls complete all as specified and directed by Engr in charge.
M&L for Virified Ceramic tiles dark shed/double charged ( square/rectangular) polished, area of each tiles of size upto 1 sqm or less. set and jointed in neat cement slurry and pointed in white or coloured cement to match 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed.
All as per item No 91 above but vertical surfaces such as skirting/dado but over10mm thick screed plasterig in CM 1:4 complete all as specified.
S&F 16 to 18 mm thick Dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size suitable size fixed with and including, making V groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment fixed over 15 mm screed plaster in cement mortar 1:4 compete all as specifed.
Providing edge moulding to 18-20mm thick of any type of stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete.
M&L for applying chalk whitening/ concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of Distemper oil Emulsion on new plastered surfaces of wall and ceiling all as directed by Engr in charge.
Preparing new plastered surfaces and M&L for applying concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of cement base paint on new plastered surfaces all as directed by Engr in charge.
Preparation of old decorated plastered surfaces brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil or greasy spots incl washing rubbing down and stopping of distempered/ lime wash and painted surfaces and M&L for applying one coat of Distemper oil Emulsion on ceiling etc., complete all as specified and as directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified.
S&F 12mm toughned glass as in partitions automatic doors and similar work including cutting to shape, drilling holes required. complete all as specified and as directed.
S&F T- type CP connectors fixed with suitable fixing arrangement to glass and stainless steel screws complete all as specified.
S&F 12mm toughned glass as in doors, work including patches cutting to shape, eadge mouldings,making suitable holes notches cutouts, connectors, with double action floor spring hydraulically oprated and suitable mortices locking arrangement and 300 mm fancy type CP handles and required fittings,complete fittings at site all as specified and as directed.
Demolition of reinforced cement cocrete Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition).
M&L providing Jodhpur stone Arch with ornamental design including carving and engraving in curved at top and supported on either side by desiger stone pillars/post or suitable decorative stone wall including suitable decorative edge moulding of following dimensions:- Width 2.90 Mtr , height 2.70 Mtr and wall/Column thickness 0.55 Mtr complete all as per directed by Engr -in charge at site. Note- (i) Contractor is resposonsible to approved the Architect design/pattern from competent aurthority before execution of work . (ii) Rate of Architect design shall be includes of this item no extra payment shall be paid to contractor on this account.
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to entre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre
S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
M&L 12 mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre,including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately)
Preparation of new POP ceiling surfaces and M&L for applying two coat of plastic Emulsion paint on POP based ceiling etc over two or more coat JK birla white putty., complete all as specified and as directed.
S&F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawingdrawing complete all as specified and directed.
5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed.
M&L for point wiring(Modular) complete for one light point / exhaust fan point / bell point controlled by one 1-way switch/ bell push, with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers with and including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches / sockets etc and making good surface by wall panelling etc, complete all as directed.
All as per srl item No. 112 here-in-before but for one socket outlet 3 pin, 5 Amps on same board.
All as per srl item No. 112 here-in-before but with 4 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire complete all as specified and directed by Engr-in-Charge
S & F Modular switch 1 way 6A , 1 module size complete all as directed.
S & F Modular switch 1 way 16A , 1 module size complete all as directed.
S & F Modular Socket , 6 A , 5 Pin , 2 module size complete all as directed.
S & F Modular Socket , 6 A / 16 A , 5 Pin , 2 module size complete all as directed.
S&F of Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed.
S&F of LED light fitting 1 X 20/22 watt (4 feet), decorative ultra slim type, with inegral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed.
S&F Bulk head fittings of Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval plastic bulk head fitting 15W LED 6000K luminaire comprising of high brightness LEDs, IP54 protection.
S&F Heavy duty Exhaust fan 300 mm sweep, 900 RPM, including louvers with cutting chases on brick wall if required and grounting with nut bolts complete all as specified and directed by Engr-in-charge.
Taking down wall mounting light fitting and refixing the same and making necessary electric connection, complete all as specified and directed.
S&F of Energy efficient round shape recess mounted polycarbonate fixture circular panel 12W LED 6500K down lighter with premium white powder coating and die cast aluminium and making necessary electric connection complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified
S&F of Distribution Board, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 8 way (Concealed flush to wall), 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.
S&F of MCB, C Curve type, 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as directed.
S&F of MCB, C Curve type, 10 kA, 32 to 40 Amp SPN with over load and short circuit protection, complete all as directed.
S&F of MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as directed.
Taking down old sub main wiring and M&L for concealed sub main wiring with 2 run of 4 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 20 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : Two run of 4 Sq.mm. and one run of 4 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
Taking down old sub main wiring and M&L for concealed sub main wiring with 2 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 20 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : Two run of 6 Sq.mm. and one run of 6 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed.
M&L for Point wiring (Concealed) (Normal) with 1.5 Sqmm (nominal area) copper conductor FRLS cable (multi-stranded) PVC insulated and unsheathed electric cable 1100 volts drawn through PVC concealed conduit of suitable size (as per conductor run) with all fittings and accessories and including PVC insulated unsheathed electric cable 1100 volts 1.5 Sqmm (multi-stranded) copper conductor single core (green colour) as continuous earth wire connected to common earth dolly including METAL FLUSH BOX made out of MS with Hylum sheet suitable size and shape complete all as specified and directed by Engr-in-Charge for one light/Fan fan point/Exhaust Fan controlled by one 5 Amps one way switch
All as per item ser No 133 above but for one 3 pin socket outlet 5 Amps on independent board
All as per item ser No 133 above but for one 3 pin socket outlet 5 Amps on same board
All as per item No 133 above but for one 3 pin socket outlet 15 Amps independent with cable of size 4.0 Sqmm for point wiring and 4.0 sqmm in continuous earth wire complete all as specified and directed by Engr-in-Charge.
S & F switch PT 1 way 5A, 1 module 240 Volts complete all as specfied and directed by Engr-in-Charge.
S & F switch PT 1 way 15A, 1 module, 240 Volts complete all as specfied and directed by Engr-in-Charge.
S & F socket, 6A - 2/3 pin combined 2 module, complete all as specfied and directed by Engr-in-Charge.
S & F Socket 6A/16A - 2/3 pin combined 2 module,complete all as specfied and directed by Engr-in-Charge.
S & F Lamp holder, PVC/Polycarbonate type with LED Bulb and back plate suitable for batten fittings complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply, laying, testing and commissioning of LT UG cable, XLPE insulated, PVC sheathed, galvanized steel strip armoured electric power cable with stranded aluminium conductor, 1100 volts grade of size 16 sqmm 2 core, suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
Excavation in trenches in Soft / dense soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out including trimming of sides, complete all as directed.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm under ground cables for protection
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to under ground cable complete all as directed.
Supply and lay 50 mm bore galvanised steel tubing Light grade with all fittings and fixtures laid in trench or ceiling or laying in floors complete all as directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm (1”) dia.
Supply and fix Valve, stop, screwed,25 mm (1”) dia pipe
M&L for Cutting the existing water supply DI/GI pipe line 50 mm dia and taking branch connection of 25 mm dia pipe by inserting Tee complete all as specified and directed by engineer-in-charge.
VIKAS CONSTRUCTION CO. (BID ID -3205811)
Bhagwati Construction Company (BID ID -3200544)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .