| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.4 L+₹71,854.18 (10.8%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹8.0 L+₹1.4 L (21.0%)Rejected-Finance KARUKAPPILLY THATTATHUKUDIYIL BUILDING KOLENCHERY 682311 | KOLENCHERY | ERNAKULAM | KERALA | 682311 | L3 | Rejected-Finance L3 |
Tender Value
₹7.4 L
EMD Value
₹18,400
Closing Date
4 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer
GCDA Kadavanthra
Electrification Of Clint Art Galler
2024_GCDA_709672_1
e4/8713/2024/GCDA
Open Tender
Electrical Works
Item Rate
30 days
GCDA Kadavanthra Ernakulam
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,575
₹18,400
29 Jan 2025
26 Nov 2024
6 Dec 2024
26 Nov 2024
4 Dec 2024
26 Nov 2024
Amount
Electrical
1.3.1 : Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.7.3 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2x4 sq.mm + 1x4 sq.mm earth wire
1.17.31 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
90.12.24.3 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.
1.55.1 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90.10.1.2 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )
90.4.9 : Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
od160669/2024_2025 : Supply of exhaust fan of size upto 305mm
90.4.10 : Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.10.1.3 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )
90.10.1.5 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )
90.4.6 : Conveyance, installation, testing and commissioning of wall mounting fans of all types using mounting brackets supplied along with the fan.
od103414/2024_2025 : Supply of 400mm sweep wall mounting fan
od103447/2024_2025 : Supply, Installation, testing and commissioning of Air Cooled High Wall mounted<br>Split Air Conditioner of 1.5 TR capacity consisting of high wall mounted type room<br>unit with cordless remote control and one number outdoor condensing unit<br>comprising of energy efficient suitable Inverter type rotary compressor for operation<br>on single phase, 230 V, 50 Hz supply, fixing the outdoor unit on raised platform as<br>per manufacturers recommendation and fixing of room ( fan Coil) unit on wall up to<br>10m distance refrigerent copper pipinh with 13mm nitril rubber insulation, providing<br>and making interconnection between room and condenser as per site conditions,<br>comprising of 1&quot; dia drain PVC pipe with insulation 10 m, canvas connection,<br>full electrical cabling from power plug near indoor unit and out door unit, vibration<br>isolation, ODU MS stand, first charge refrigarant gas, min 3 star rated as per BEE<br>suitable stabilizer etc. complete as required.
od160980/2024_2025 : Supply, Installation, testing and commissioning of Air Cooled High Wall mounted Split Air Conditioner of 0.75 TR capacity consisting of high wall mounted type room unit with cordless remote control and one number outdoor condensing unit comprising of energy efficient suitable Inverter type rotary compressor for operation on single phase, 230 V, 50 Hz supply, fixing the outdoor unit on raised platform as per manufacturers recommendation and fixing of room ( fan Coil) unit on wall up to 10m distance refrigerent copper piping with 13mm nitril rubber insulation, providing and making interconnection between room and condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation 10 m, canvas connection, full electrical cabling from power plug near indoor unit and out door unit, vibration isolation, ODU MS stand, first charge refrigerant gas, min 3 star rated as per BEE suitable stabilizer etc. complete as required.
od104511/2024_2025 : Supply, Installation, testing and commissioning of Inverter type Air Cooled High<br>Wall mounted Split Air Conditioner of 2 TR capacity consisting of high wall mounted<br>type room unit with cordless remote control and one number outdoor condensing unit<br>comprising of energy efficient suitable rotary compressor for operation on single<br>phase, 230 V, 50 Hz supply, fixing the outdoor unit on raised platform as per<br>manufacturers recommendation and fixing of room ( fan Coil) unit on wall up to 10m<br>distance refrigerant copper piping with 13mm nitril rubber insulation, providing and<br>making interconnection between room and condenser as per site conditions,<br>comprising of 1&quot; dia drain PVC pipe with insulation 10 m, canvas connection,<br>full electrical cabling from power plug near indoor unit and out door unit, vibration<br>isolation, ODU MS stand, first charge refrigerant gas. Min 3 star as per BEE suitable stabilizer<br>etc. complete as required.
90.3.19.3 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required
od104512/2024_2025 : Supply, conveyance, installation and testing of 12 Watts Indoor Ceiling track Light(Warm White) fixed on Flexibly Rotatable Light Head
od104513/2024_2025 : Supply Conveyance, installation, testing and commissioning of 2250mmX2250mmX12mm size18 watt square LED downlight, 3000 light, 5000k white light
1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required.
od104514/2024_2025 : Supply Conveyance, installation, testing and commissioning of 9W,230V,50Hz,LED bulb
od104781/2024_2025 : Supply, Installation, testing and commissioning of 5 star rated 0.5HP water Pump
od106422/2024_2025 : Dismantling of existing wiring, DB and other boards and keeping its safely at a place as per the instruction of site engineer
DB,MCB, isolator, earthing,
2.4.2 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door
2.4.1 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.10.2 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural
2.5.2 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
od171580/2024_2025 : Supplying and fixing 40amps 415volts "C" curve 4P MCB complete with connections, testing and commissioning etc. as required
od171581/2024_2025 : Supply, installation, testing and commissioning of 2kVA ONLINE UPS with battery interlink cables, battery rack etc
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
od160352/2024_2025 : Fabrication, supply &amp; installation of dust and vermin proof, wall mounting, Sintex make Code No 3525 meter box suitable for fixing KSEB meter,fuse units, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.
od160353/2024_2025 : Supply and fixing 100A, 415 V, DIN type fuse with base
od160355/2024_2025 : Supply and fixing 100 A, 2 Way neutral links mounted on DMC/SMC base
od171630/2024_2025 : All documentaion works including preparation of all authority standard drawings, submitting KSEB, obtaining power allocation & permanent power connection, etc. and commissioning of the whole installation in the premises. (All statutory payments will be reimbursed with original receipts.)
5.7 : Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
5.16 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Fire extinguishers
od171640/2024_2025 : Supply Installation Testing, Commissioning of fire extinguisher ABC type 5 kg. Capacity complete with initial charges and installation brackets.
Grace Enterprises (BID ID -2000231)
Power Care Electrical (BID ID -2000716)
Bidder Name
Grace Enterprises
Power Care Electrical
Rickson India
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1113494.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .