Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.7 LAccepted-AOC | ₹65.7 L | L1 | Accepted-AOC Being Lowest Vendor |
| 2 | L2₹72.4 L+₹6.8 L (10.3%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | ₹72.4 L+₹6.8 L (10.3%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹82.9 L+₹17.2 L (26.2%)Rejected-Finance | ₹82.9 L+₹17.2 L (26.2%) | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹1.1 Cr+₹43.5 L (66.2%)Rejected-Finance | ₹1.1 Cr+₹43.5 L (66.2%) | L4 | Rejected-Finance Being not L1 |
| 5 | L5₹1.1 Cr+₹46.3 L (70.5%)Rejected-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | ₹1.1 Cr+₹46.3 L (70.5%) | L5 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | M/S SRI VENKATA BHAVANI CONSTRUCTIONS L2 | aswitha engineering works L1 | SAI SREENIVASA ENGINEERING L4 | MSN ENGINEERING WORKS L5 | Power Dynamics L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Providing manpower for day to day maintenance and breakdown and call on repairs for uninterrupted power supply by providing at least a minimum one skilled and two semiskilled for job to LT Panels and Switchgears/ DOL Starters/ Star-Delta Starters, Main & Auxilary contacts/ Metering Devices/ Pit/ Sump level sensors/ Dock Water Level Sensors of SDD pump house equipment for carrying out following Repairs, Overhauling, Servicing, Preventive Maintenance and refixing the same after carrying out rapairs / overhauling complete all as specified and as directed :
Note: All Consumables & spares will be supplied by contractor only.
(a) Check and found if any cracked case when inspected should be replaced.
(b) Check all contacting tips condition weather they are in good condition or corroded, if corroded do proper alchohol clearing.
(c) Check alignment of foundation and make it in exact fixing location and provide grounding facility.
(d) Check the compotnents of the LT panel with actual designs as provided drawings.
(e) Check all mechanical interlocks and ensure all connections in tightining.
(f) Check phasing connection of busbar with provided drawings. | 335 | Each Job | 2,500 ₹8,37,500 | 2,000 ₹6,70,000 Lowest | 3,300 ₹11,05,500 | 3,000 ₹10,05,000 | 2,850 ₹9,54,750 |
| 1.01(g) Mechanical check and visual inspection for air circuit breakers and moulded case circuit breakers. (h) Check the coil codtion and current ratings while in operation. (j) Check the correct opreation of NO & NC of auxilary contacts (k) Verify proper operation and remove any accumulation of dust material on moving parts and contacts and clean upto zero (l) Inspect transmitter/ antenna for damage or obstruction. (m) Check electrical connections and cables. (n) Verify proper operation and update the log (o) Record measurement data with physical reference for trending/ operational status checks (p) Visual inspection: Look for signs of damage, corrosion, or wear on the transmitter, antenna, and surrounding area. (q) Electrical checks: Verify power supply, cable connections, and grounding/ earthing. (r) Measurement verification: Compare measured values with reference measurements. (s) Alarm checks: Test alarms (High & Low Relay) and ensure they're functioning correctly. | ||||||||
| 1.02(t) Cleaning: Clean antenna, lens, and signal pass through enclosure with soft cloth and mild suitable liquid/ solution (u) Alignment check: Verify transmitter alignment with the liquid surface. (v) Connected Accessories: Check and verify the sensor enclosures, connected pipes with glands and supports, connected power/ control cables for proper operation. (w) Documentation: Update maintenance records and submit to all concerns for verification and necessary actions. (x) Accuracy checks: Perform reference measurements to verify accuracy. (y) O-ring and gasket inspection: Inspect and replace worn or damaged seals if required and items will be supplied as separate Schedule item. (z) Contact/ Non-contact frequency check: Verify frequency and adjust if necessary as suggested by binding data. (aa) Communication protocol check: Verify communication settings. (ab) Comprehensive system check: Inspect transmitter, antenna, and surrounding area. (ac) Antenna/ Transmitter inspection: Inspect and clean or replace tansmitter/ antenna. (ad) Calibration check: Verify transmitter calibration. (ae) Documentation update: Update maintenance record | ||||||||
| 1.03(af) Transmitter inspection: Perform thorough inspection of transmitter components. (ag) Component replacement: Replace worn or damaged components if required and items will be part of this Schedule only. (ah) Firmware update: Update firmware to latest version to meet provisional requirement of data communication center. (aj) Documentation update: Update maintenance records. | ||||||||
| 2.00Supply of components/ material/ item/ spare of LT Panel & Switch Gear as specified and as directed | ||||||||
| 2.01 | Supply only ACB 3 pole, 415V, with thermal magnetic release of capacity 1250A with breaking capacity 50 KA all as specified and directed.
Make :- L&T CN-CSE, 1250A or equivalent in other make to suit the site conditions . | 2 | Each | 1,38,000 ₹2,76,000 | 75,000 ₹1,50,000 Lowest | 1,29,900 ₹2,59,800 | 1,35,000 ₹2,70,000 | 1,19,000 ₹2,38,000 |
| 2.02 | Supply of 4P DN4-1250N, Spreader links all specified and directed. | 1 | Each | 35,000 ₹35,000 | 40,000 ₹40,000 | 31,500 ₹31,500 | 6,500 ₹6,500 Lowest | 38,815 ₹38,815 |
| 2.03 | Suppl only MCCB 4 pole, 415V with thermal magnetic release of capacity 630A with breaking capacity 50KA all as specified and directed.
Make :- L&T DN3-630N, 630A or equivalent in other make as specified in PS to suit the site conditions . | 1 | Each | 24,000 ₹24,000 | 20,304.17 ₹20,304.17 Lowest | 25,150 ₹25,150 | 32,000 ₹32,000 | 28,313 ₹28,313 |
| 2.04 | Supply only MCCB 3 pole, 415V with thermal magnetic release of capacity 630A with breaking capacity 50 KA all as specified and directed.
Make :- L&T DN3-630M, 630A or equivalent in other make as specified in PS to suit the site conditions . | 1 | Each | 24,000 ₹24,000 | 24,458.33 ₹24,458.33 | 24,900 ₹24,900 | 27,000 ₹27,000 | 19,744 ₹19,744 Lowest |
| 2.05 | Supply of 3P DN3-630M, Spreader links all as specified and directed. | 2 | Each | 3,000 ₹6,000 | 3,491.67 ₹6,983.33 | 2,850 ₹5,700 | 2,000 ₹4,000 Lowest | 2,478 ₹4,956 |
Tender Value
₹85.9 L
EMD Value
₹1.5 L
Closing Date
16 Jul 2026, 6:00 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
DAY TO DAY MAINTENANCE AND CALL ON REPAIRS FOR ATTENDING BREAKDOWNS AT SOUTH DRYDOCK PUMP HOUSE INCLUDING REPLACEMENT OF UNSV ITEMS FOR DOL STARTERS STAR DELTA STARTERS METERING EQUIPMENT SWITCH GEARS DIGITAL WATER SENSORS FPT SYSTEMS AT DRYDOCKS NAV
2026_MES_771374_1
8539/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naval Dockyard Visakhapatnam
As per tender document
8 documents required · 8 mandatory
₹1,000
GE (I) DM Visakhapatnam
₹1.5 L
Yes
23 Sept 2026
11 Jun 2026
18 Jul 2026
11 Jun 2026
16 Jul 2026
2 Jul 2026
12 Jun 2026 - 30 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing manpower for day to day maintenance and breakdown and call on repairs for uninterrupted power supply by providing one skilled and two semiskilled to LT Panels and Switchgears/ DOL Starters/ Star-Delta Starters, Main & Auxilary contacts/ Metering Devices/ Pit/ Sump level sensors/ Dock Water Level Sensors of SDD pump house equipment for carrying out following Repairs, Overhauling, Servicing, Preventive Maintenance and refixing the same after carrying out rapairs / overhauling complete all as specified and as directed :
Note: All Consumables & spares will be supplied by contractor only.
(a) Check and found if any cracked case when inspected should be replaced.
(b) Check all contacting tips condition weather they are in good condition or corroded, if corroded do proper alchohol clearing.
(c) Check alignment of foundation and make it in exact fixing location and provide grounding facility.
(d) Check the compotnents of the LT panel with actual designs as provided drawings.
(e) Check all mechanical interlocks and ensure all connections in tightining.
(f) Check phasing connection of busbar with provided drawings. | 335 | Each Job | - | - |
| 1.01 | (g) Mechanical check and visual inspection for air circuit breakers and moulded case circuit breakers.
(h) Check the coil codtion and current ratings while in operation.
(j) Check the correct opreation of NO & NC of auxilary contacts
(k) Verify proper operation and remove any accumulation of dust material on moving parts and contacts and clean upto zero
(l) Inspect transmitter/ antenna for damage or obstruction.
(m) Check electrical connections and cables.
(n) Verify proper operation and update the log
(o) Record measurement data with physical reference for trending/ operational status checks
(p) Visual inspection: Look for signs of damage, corrosion, or wear on the transmitter, antenna, and surrounding area.
(q) Electrical checks: Verify power supply, cable connections, and grounding/ earthing.
(r) Measurement verification: Compare measured values with reference measurements.
(s) Alarm checks: Test alarms (High & Low Relay) and ensure they're functioning correctly. | - | - | - | - |
| 1.02 | (t) Cleaning: Clean antenna, lens, and signal pass through enclosure with soft cloth and mild suitable liquid/ solution
(u) Alignment check: Verify transmitter alignment with the liquid surface.
(v) Connected Accessories: Check and verify the sensor enclosures, connected pipes with glands and supports, connected power/ control cables for proper operation.
(w) Documentation: Update maintenance records and submit to all concerns for verification and necessary actions.
(x) Accuracy checks: Perform reference measurements to verify accuracy.
(y) O-ring and gasket inspection: Inspect and replace worn or damaged seals if required and items will be supplied as separate Schedule item.
(z) Contact/ Non-contact frequency check: Verify frequency and adjust if necessary as suggested by binding data.
(aa) Communication protocol check: Verify communication settings.
(ab) Comprehensive system check: Inspect transmitter, antenna, and surrounding area.
(ac) Antenna/ Transmitter inspection: Inspect and clean or replace tansmitter/ antenna.
(ad) Calibration check: Verify transmitter calibration.
(ae) Documentation update: Update maintenance record | - | - | - | - |
| 1.03 | (af) Transmitter inspection: Perform thorough inspection of transmitter components.
(ag) Component replacement: Replace worn or damaged components if required and items will be part of this Schedule only.
(ah) Firmware update: Update firmware to latest version to meet provisional requirement of data communication center.
(aj) Documentation update: Update maintenance records. | - | - | - | - |
| 2Supply of components/ material/ item/ spare of LT Panel & Switch Gear as specified and as directed | |||||
| 2.01 | Supply of ACB 4P DN4-1250N, 1250A all as specified and directed. | 2 | Each | - | - |
| 2.02 | Supply of 4P DN4-1250N, Spreader links all specified and directed. | 1 | Each | - | - |
| 2.03 | Supply of ACB CN - CS, 1250 S1, 1250A 3P all as specified and directed. | 2 | Each | - | - |
| 2.04 | Supply of MCCB 4P DN3-630M, 630A all as specified and directed. | 1 | Each | - | - |
| 2.05 | Supply of MCCB - L&T 3P DN3-630M, 630A all as specified and directed. | 1 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_863814.xls
BOQ • 0.31 MB
8539Tender.pdf
Tender Documents • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .