| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | Rejected-Technical | - | Rejected-Technical Failed to submit documents in line with PQC. | |
| 3 | Rejected-Technical 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | - | Rejected-Technical Failed to submit documents in line with PQC. |
| Sl No | Description | Qty | Unit | LAMOS TECHNOLOGY SOLUTIONS PVT LTD L1 |
|---|---|---|---|---|
| 1.00 | Dismantling/disconnection of existing electrics including light fittings, fans, switch boards, telephone cables, wires etc from the conference hall. The disconnected and dismantled materials shall be transported to the electrical workshop - PH1. | 1 | LS | 25,000 ₹25,000 Lowest |
| 2.00 | Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 1.5 sq.mm copper red/yellow/blue/black/green wires. Acceptable makes: Finolex, RR kabel, Polycab, Traco,KEI | 7,100 | M | 28 ₹1,98,800 Lowest |
| 3.00 | Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 2.5 sq.mm copper red/yellow/blue/black/green wires. Acceptable makes: Finolex, RR kabel, Polycab, Traco,KEI | 5,920 | M | 44 ₹2,60,480 Lowest |
| 4.00 | Supply of 19/20mm medium type ivory coloured rigid ISI marked PVC electrical conduit with all accessories such as junction boxes, couplers, bends, tee, elbow, G.I/PVC saddles, screws,wall/ceiling plugs etc. required for the surface conduit wiring. | 1,950 | M | 50 ₹97,500 Lowest |
| 5.00 | Installation of 1.5 sqmm copper wires. The installation scope shall include drawing of cables through rigid PVC conduits from switch board/JBs to light fittings/fan/plug points/junction boxes and termination of cables at the above points. Cables shall be jointed or tapped only at the junction box/switch boards. Care should be taken to see that not more than 6 cables are taken through a single conduit. The cables used for wiring circuit shall be standard colour pattern/ according to direction of site incharge. | 7,100 | M | 9 ₹63,900 Lowest |
| 6.00 | Installation of 2.5 sqmm copper wires. The installation scope shall include drawing of cables through rigid PVC conduits from switch board/JBs to light fittings/fan/plug points/junction boxes and termination of cables at the above points. Cables shall be jointed or tapped only at the junction box/switch boards. Care should be taken to see that not more than 6 cables are taken through a single conduit. The cables used for wiring circuit shall be standard colour pattern/ according to direction of site incharge. | 5,920 | M | 12 ₹71,040 Lowest |
| 7.00 | Installation of 19/20mm rigid PVC conduit wiring system. The installation scope shall include fixing of PVC conduits and its accessories to the walls / ceilings /columns etc. and neatly clamping at a uniform spacing of 450mm using GI saddles, tagging, drilling holes, minor civil work etc.Suitable sized junction boxes shall be provided at regular intervals. The materials required for the installation such as PVC saddles, screws, nuts and bolts, PVC Sbend, junction boxes etc shall be supplied by the contractor. The erection scope shall include, drilling holes, chipping ,plastering, minor civil works etc. | 200 | M | 40 ₹8,000 Lowest |
| 8.00 | Installation of 19/20mm PVC concealed conduit wiring system. The installation scope shall include cutting/chipping of brick/concrete wall/floor, removal of existing GI conduits, fixing of PVC conduits and its accessories, plastering the walls / floors/ceilings /columns etc. The materials required for the work including nails, PVC bend,junction boxes, cement, sand etc are under the scope of contractor. | 1,750 | M | 138 ₹2,41,500 Lowest |
| 9.00 | Supply of DB (Double door IP52 or above) with accessories as per the following details
Type: Surface mounting , Double door 3phase, 4 way
Protection: IP52 or above
Incomer: 40 A,4P,MCB isolator + 40A,30ma RCCB -1No. Outgoing 6A,1P,MCB(class B) -12nos. Busbar: 63/phase, fully insulated.
Make: Legrand /equivalent | 2 | NO | 10,578 ₹21,156 Lowest |
| 10.00 | Supply of DB (Double door IP52 or above) with accessories as per the following details
Type: Surface mounting , Double door 3phase, 6 way
Protection: IP52 or above
Incomer: 63A,4P,MCB Isolator + 63A,30ma RCCB -1No. Outgoing 20A,1P,MCB (class C) -9nos. Out going 16A,1PMCB (classC) - 9Nos
Busbar: 63/phase, fully insulated.
Make: Legrand /equivalent | 2 | NO | 13,182 ₹26,364 Lowest |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
16 Jun 2026, 11:00 amClosed
SM(Mat)C
Corporate Materials, PD Administration Building, FACT - Udyogamandal, Kochi, Kerala
Re-wiring and Renovation of 16 Nos of Guest Rooms in Ambalamedu House at FACT CD, Ambalamedu, as per tender conditions.
2026_FACT_910323_1
04026/2026-2027/E33578
Open Tender
Miscellaneous Works
Item Rate
180 days
FACT - Cochin Division
Please refer tender documents.
7 documents required · 7 mandatory
₹0
₹25,000
Yes
23 Sept 2026
26 May 2026
17 Jun 2026
26 May 2026
16 Jun 2026
26 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling/disconnection of existing electrics including light fittings, fans, switch boards, telephone cables, wires etc from the conference hall. The disconnected and dismantled materials shall be transported to the electrical workshop - PH1. | 1 | LS | - | - |
| 2 | Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 1.5 sq.mm copper red/yellow/blue/black/green wires. Acceptable makes: Finolex, RR kabel, Polycab, Traco,KEI | 7,100 | M | - | - |
| 3 | Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 2.5 sq.mm copper red/yellow/blue/black/green wires. Acceptable makes: Finolex, RR kabel, Polycab, Traco,KEI | 5,920 | M | - | - |
| 4 | Supply of 19/20mm medium type ivory coloured rigid ISI marked PVC electrical conduit with all accessories such as junction boxes, couplers, bends, tee, elbow, G.I/PVC saddles, screws,wall/ceiling plugs etc. required for the surface conduit wiring. | 1,950 | M | - | - |
| 5 | Installation of 1.5 sqmm copper wires. The installation scope shall include drawing of cables through rigid PVC conduits from switch board/JBs to light fittings/fan/plug points/junction boxes and termination of cables at the above points. Cables shall be jointed or tapped only at the junction box/switch boards. Care should be taken to see that not more than 6 cables are taken through a single conduit. The cables used for wiring circuit shall be standard colour pattern/ according to direction of site incharge. | 7,100 | M | - | - |
| 6 | Installation of 2.5 sqmm copper wires. The installation scope shall include drawing of cables through rigid PVC conduits from switch board/JBs to light fittings/fan/plug points/junction boxes and termination of cables at the above points. Cables shall be jointed or tapped only at the junction box/switch boards. Care should be taken to see that not more than 6 cables are taken through a single conduit. The cables used for wiring circuit shall be standard colour pattern/ according to direction of site incharge. | 5,920 | M | - | - |
| 7 | Installation of 19/20mm rigid PVC conduit wiring system. The installation scope shall include fixing of PVC conduits and its accessories to the walls / ceilings /columns etc. and neatly clamping at a uniform spacing of 450mm using GI saddles, tagging, drilling holes, minor civil work etc.Suitable sized junction boxes shall be provided at regular intervals. The materials required for the installation such as PVC saddles, screws, nuts and bolts, PVC Sbend, junction boxes etc shall be supplied by the contractor. The erection scope shall include, drilling holes, chipping ,plastering, minor civil works etc. | 200 | M | - | - |
| 8 | Installation of 19/20mm PVC concealed conduit wiring system. The installation scope shall include cutting/chipping of brick/concrete wall/floor, removal of existing GI conduits, fixing of PVC conduits and its accessories, plastering the walls / floors/ceilings /columns etc. The materials required for the work including nails, PVC bend,junction boxes, cement, sand etc are under the scope of contractor. | 1,750 | M | - | - |
| 9 | Supply of DB (Double door IP52 or above) with accessories as per the following details
Type: Surface mounting , Double door 3phase, 4 way
Protection: IP52 or above
Incomer: 40 A,4P,MCB isolator + 40A,30ma RCCB -1No. Outgoing 6A,1P,MCB(class B) -12nos. Busbar: 63/phase, fully insulated.
Make: Legrand /equivalent | 2 | NO | - | - |
| 10 | Supply of DB (Double door IP52 or above) with accessories as per the following details
Type: Surface mounting , Double door 3phase, 6 way
Protection: IP52 or above
Incomer: 63A,4P,MCB Isolator + 63A,30ma RCCB -1No. Outgoing 20A,1P,MCB (class C) -9nos. Out going 16A,1PMCB (classC) - 9Nos
Busbar: 63/phase, fully insulated.
Make: Legrand /equivalent | 2 | NO | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
Tenderdoc.pdf
Tender Documents • 7.51 MB
Unpricedbid.pdf
Tender Documents • 0.10 MB
Compliancestatement.pdf
Tender Documents • 0.28 MB
BOQ_956741.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .