Tender Value
₹54.8 Cr
EMD Value
₹12 L
Closing Date
7 Aug 2026, 4:00 pmClosed
Additional Chief Engineer(Procurement & Contracts)
Supply, Laying, Erection, Testing and commissioning of 220kV 1Cx1200 sq. mm D/C (2*(3+0)) Cu. conductor U/G cable laying from prop. 220kV M/C cable termination Monopole Loc. No. 1C/0 to 220kV Khoraj SS with 4.20RKM UG Cable for M/s Maruti Suzuki India Limited (MSIL)
321597
ACE(P&C)/Contracts/SS/E-483/220kV/UG/S&L,E
Open
Electrical Works
Works
Vadodara
30 documents required · 21 mandatory · 9 optional
₹11,800
Gujarat Energy Transmission Corporation Limited
₹12 L
7 Aug 2026
8 Jul 2026
14 Aug 2026
8 Jul 2026
7 Aug 2026
8 Jul 2026
Estimated Cost of laying of two equal lengths of FOAC (Fiber Optic Approach Cable) ( DWSM - Dual window single mode, 48F) - with installation hardware like ties / clips /
cleats, conduits, HDPE ducts, supports, fittings, accessories, Fiber Optic Distribution Panel(FODP), FOAC joint box (Continuous length of FOAC is preferred, however due
to limitation of laying continuous long length of FOAC, one joint may be provided only if required) etc with required arrangement to lay along side of U/G cable -
(Annexure-B1 (Supply) & B2 (Erection))
Estimated Cost (Supply Part) (Annexure-B1)
Sr.No. Name of Line FOAC Single Length (DWSM 48F) Nos. of such sigle length of FOAC Total length of FOAC (DWSM
(meter) required 48F) (meter)
1 220kV Khoraj S/S to M/s Maruti Suzuki India Ltd Line 4300 2
Estimated Cost (Erection Part) (Annexure-B2)
Sr.No. Name of Line FOAC Single Length (DWSM 48F) Nos. of such sigle length of FOAC to Total length of FOAC (DWSM
(meter) be laid 48F) (meter)
1 220kV Khoraj S/S to M/s Maruti Suzuki India Ltd Line 4300 2
Following points are important from work execution perspective, same may please be noted.
i) Fiber optic approach cable (FOAC) shall be laid with 220kV cable system strictly as per approved method of construction i.e MOC.Continuous length of FOAC is preferred, however due to
limitation of laying continuous long length of FOAC, one joint may be provided only if required
ii) Two to Three rings of extra loop length shall be kept buried underground at foot of both end termination tower after laying FOAC cable with 220kV cable as per MOC.
iii) FOAC cable length remain outside and above the ground level shall be 2 times the height of each termination tower at both end. Each run of FOAC cable coming out after laying in underground
section should be brought up to third cross arm of termination tower after passing it through HDPE pipes and properly tying up with tower. Also, each run of FOAC cable shall be terminated in
individual joint box on each termination tower.
iv) Balance length of each FOAC cable (i.e. Approximately half of tower height) after bringing out the FOAC cable above from ground level and up to third cross arm of termination tower, it shall be
managed in rings properly with fixing clamp arrangement to hold up it on end termination tower.
v) As per standard GETCO format of "End to End test.pdf" , after laying FOAC cable, each length shall be tested for end to end test using power meter and OTDR. Original copy of Test report duly
sealed and signed with date, name & designation of testing person, executing contractor and witnessing officer one each from telecom as well as TR/Const. nominated from respective EE(Telecom)
and EE(TR)/EE(const.) respectively, shall be submitted to under signed & one copy to respective telecom unit, invariably without fail
vi) Only after getting clearance on validity of test report submitted to this office, filed officer will take further necessary action on commercial part.
vii) DRS (Data requirement sheet) and drawing approval shall be taken for FOAC & joint box before kick starting any erection activity. The work executing contractor must have to do
correspondence on eamil to concern EE (Const.) with copy to project & engineering department, corporate office, GETCO for necessary concurrence and intimation about to start erection/laying.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
4. EMD BG Format.pdf
Form for Networth Annual turnover LA.pdf
220 kv 1C 1200 sq. mm copper XLPE cable R2 June 2023 OS 3.3.pdf
400 220 132 kV LA R6 June 22.pdf
Amendment- Structure weight.pdf
Ammendment for TTR validity 26.02.2026.pdf
CABLE ROUTE MARKER.pdf
CABLE TAG.pdf
Jointing bay reference drg for tender.pdf
MAINTENANCE FREE EARTHPITS R3 29.05.20-Normal Soill.pdf
MAINTENANCE FREE EARTHPITS R3 29.05.20-Rocky Soill.pdf
R1 MOC 220 kv DC CABLE LAYING 24052023.pdf
RCC SLAB.pdf
TREFOIL CALMP.pdf
WARNING BOARD.pdf
WARNING TAP.pdf
G.I. EARTHING STRIPS.PDF
OPGW (48F) specs final-R2-11.09.2023 final.pdf
Standard MQP GI Tower material for issuence to SUPPLIER COPY.PDF
TS SS STR R12 11.03.2024.pdf
Amendment -I Part-I Tender Spec. E-483 220kV LILO Khoraj UG.pdf
FOAC BOQ Annexure-II.pdf
EMD BG Format.pdf
SD cum PBG Format.pdf
Public Procurement Circular of GOI.pdf
Tender Notice-E-483 220kV LILO Khoraj UG.pdf
Tender Spec. Part-I E-483 220kV LILO Khoraj UG.pdf
BOQ for Reference.pdf
Corrigendum-04 Revision in Estimated Cost.pdf
CORRIGENDUM
Corrigendum-03 for Date Extension.pdf
CORRIGENDUM
REFERENCE DRG.OF LAYING MODALITY.PDF
CORRIGENDUM
Final Addendum to Technical specs of 220 kV 1200 sq.mm XLPE cable.pdf
CORRIGENDUM
Corrigendum No. 2.pdf
CORRIGENDUM
Corrigendum-01 for Date Extension.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .