Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC | ₹11.6 L | L1 | Accepted-AOC L1 |
Tender Value
₹13.2 L
EMD Value
₹26,371
Closing Date
11 Dec 2023, 3:00 pmClosed
Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Repairing, Maintenance and Restoring of existing fire fighting system by providing necessary spare parts of Agartala Govt. Dental College, IGM Hospital Complex
2023_CEPWD_44387_1
51/EE/DNIeT/MECH.DIVN/AGT/2023
Open Tender
Electrical Works
Works
395 days
AGARTALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹26,371
25 Apr 2024
29 Nov 2023
11 Dec 2023
29 Nov 2023
11 Dec 2023
29 Nov 2023
Amount
Providing & fixing of SS female coupling on the outlet with lock in/c maintenance of SS Fire Hydrant Valve (Landing Valve) 80 mm etc complete as per direction of the Engineer-in-charge.
Providing & fixing 63 mm dia 15 m long re-inforced rubber lined(RRL) woven jacketed hose tested to bursting pressure 32 kg/sqcm including gunmetal male and female instanteneous type coupling approved by fire authority, machine would with G.I wire complete in all respects. Hose shall conform to I:S 636 type II and coupling to IS: 903-1985 with ISI certification(Two per hydrant Station) etc complete as per direction of the Engineer-in-charge.
Repairing & maintenance of MS Sheet cabinet for fire hose ( 750 X 600 x 250 mm ) in/c two or more coats of paintinting by red paint , replacement of front fibre glass, repairing of locking arrangement with lock etc complete as per direction of the Engineer-in-charge.
Repairing & maintenance of 150 mm dia Sluice Valve in/c replacement of SS Spindle & glands etc complete as per direction of the Engineer-in-charge. 150 mm dia
Repairing & maintenance of 250 mm dia Non return Valve in/c replacement of glands and others necessary spares etc complete as per direction of the Engineer-in-charge. 250 mm dia.
Servicing of Fire Pumps & motors with necessary cleaning, greasing, oiling, checking of base along with checking of electrical connections to the Pump sets etc complete as per direction of the Engineer-in-charge.
Motor driven Hydrant Pump(75HP , 2955 rpm, 3 phase induction motor)
Motor driven Sprinkler Pump(75HP , 2955 rpm, 3 phase induction motor)
Motor driven Jockey Pump(12.5 HP 2000 rpm 3 phase induction motor)
Servicing & maintenance of Engine driven Fire Pump by changing of Engine oil in/c necessary filters cleaning, greasing, oiling, checking of base, motor along with checking of bodily electrical connections to the Pump sets etc complete as per direction of the Engineer-in-charge.
Servicing of Motor Control Centre with Diesel engine Controller for operation of Fire Pumps including replacement of damaged/ defected parts as per system requirement etc complete as per direction of the Engineer-in-charge. etc complete as per direction of the Engineer-in-charge.
Providing & fixing of 150 amp-hour 12 volt Battery for engine driven Fire Pump etc complete as per direction of the Engineer-in-charge.
Servicing of Pressure Switches including necessary adjustments of pressure switches for automatic operation of fire pumps etc complete as per direction of the Engineer-in-charge. etc complete as per direction of the Engineer-in-charge.
Providing & fixing of Pressure Switch for automatic operation of Fire Pumps etc complete as per direction of the Engineer-in-charge.
Providing and fitting fixing of Pressure gauges (100/150 mm dia) inside Fire water Pump House including Cost of material by replacing old damaged ones etc complete as per direction of the Engineer-in-charge.
Providing fitting fixing , installation & commissioning of 15mm/ 25 mm dia, SITC Forged Brass ball valves with brass body nickle coated , brass ball, hard chrome plated, suitable for fire fighting etc complete as per direction of the Engineer-in-charge.
Providing and fixing standard size SS branch pipe with gunmetal nozzle 16 mm dia outlet with standard male instantaneous spring lock type 63 mm dia coupling. Branch pipe and nozzle shall confirm to IS: 903-1985. etc complete as per direction of the Engineer-in-charge.
Maintenance & fitting fixing of fire-brigade inlet connection with male instantaneous inlet coupling complete with Cap and chain for suitable dia MS Pipe connection, ISI marked conforming to IS: 904 as required (material-copper/aluminium alloy) ,4 way 150 mm dia MS pipe etc complete as per direction of the Engineer-in-charge.
24 hours (3 shifts)Operation in/c watch & ward of fire fighting system of G+7 building of Agartala Govt. Dental College, IGM Hospital Complex for 1(one) year as per direction of the Engineer-in-charge.
Comprehensive annual maintenance contract (CAMC) of complete fire protection system from the date of final commissioning with monthly checking, routing, preventive maintenance for 1(one) year as per direction of the Engineer-in-charge.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_45096.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .