Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
8 Oct 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Secretary
Kerala Khadi and Village Industries Board, Vanchiyoor, Thiruvananthapuram
Furnishing of KGS and Maintenance of District Office Building at Cherooty Road in Kozhikode District.
2025_KKVIB_804279_1
KB.No.6646/2025/Engg
Open Tender
Civil Works - Others
Piece-work
150 days
Cherooty Road in Kozhikode District
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
Yes
₹50,000
Yes
10 Oct 2025
30 Sept 2025
10 Oct 2025
30 Sept 2025
8 Oct 2025
30 Sept 2025
Amount
APPENDIX-A
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar ( D S R 2018 , 15.7.4 )
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in Charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) ( D S R 2018 , 15.2 . 1 )
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the materials within 50 metres lead of G.S. Sheet ( 2018 ,D S R 15.28.1 )
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. ( D S R 2016, 15.56 )
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. ( D S R 2018 , - 15.3 )
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin- charge. ( 2018 D S R , 15.5 )
Dismantling steel work in built up sections in angles, tees, flats and channels including all guzzet plates, bolts nuts, cutting rivets, welding, etc. including dismembering and stacking within 50 metres lead ( 2018 D S R , 15.18. )
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm ( D S R 2016 , 15.23.1 )
Dismantling doors, windows and clerestory windows (steel or wood) shutter including Chowkhats, architrave, hold fasts etc complete and stacking within 50 metres lead Of area 3 sq. metres and below ( D S R 15.12.1. )
Dismantling Aaluminium / Gypsum Partitions, doors, windows, Fixed glazing and False ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. ( D S R 15.57 )
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. ( D S R , 2.8.1 )
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. ( D S R 2016 - 2.25 )
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). ( D S R 4.1.8. )
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : - 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). ( 2016 D S R 4.1.5 )
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo - Mechanically Treated bars of Grade Fe 500 D or more . ( 2018 D S R, 5.22A .6 )
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) ( 2018 D S R, 5.1.2 . )
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. ( 2016 D S R 5.9.1. )
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. ( D S R 6.38 )
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete ( Observed Data Buildings 50.6.2.2. )
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) ( 2016 D S R 13.4.1. )
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) D S R 13.7.1 )
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : - With cement mortar 1:4 (1 cement : 4 fine sand). ( 2016 D S R 14.1.1. )
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete . ( 2016 D S R 14.43. )
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. ( D S R 13.26 )
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work. ( D S R 13.60.1. )
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer ( D S R 13.43.1 )
Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (Two or more coats applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface ( D S R 13.111.1 )
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. ( D S R 13.61.1 . )
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : One or more coats on old work. ( D S R 13.99.1 )
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : One or more coats on old work ( 2018 D S R 13.98.1 )
Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work ( D S R 2018 13.66.1 )
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work ( D S R 2018 , 13.52.1 )
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm ( D S R 11.41 .2 )
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm ( D S R 11.48.2. )
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade ( D S R 8.2.2.2. ) Area of slab over 0.50 sqm
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm, with all 4 side tapered ( D S R 2016 12.45.1. )
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. ( D S R 10.2. )
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. : - Hot finished welded type tubes ( D S R 10.16.1 )
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ( D S R 12.50 )
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling , partition etc. complete (frame work to be paid seperatately). 8 MM thick Cement fiber board as per IS: 14862 ( D S R 12.26.1 )
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Flashings/ Aprons.( Upto 600 mm) ( D S R 12.51.2. )
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer. MS Tube ( D S R 10.26.1 )
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm ( D S R 9.96.1. )
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm ( D S R 9.97.2. )
Providing and fixing Aluminium Handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm ( D S R 9.100.1. )
Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 125x65x2.12 mm ( 2018 D S R, 9.57.1. )
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: ( D S R 25.7. )
Providing and fixing Aluminium work for Doors, Windows, Ventilators and Partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion - Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) ( D S R 21.1.1.3 )
For Shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) ( D S R 21.1.2.3 )
Providing and fixing Double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness ( D S R 21.4.1. )
Supplying and Fixing Good Quality Stainless Steel Door Handle For Glass Door of size 45 cm With all necessary screws, nut bolts etc complete as approved by the Engineer in Charge. ( Observed Data od 46046/2021-2022 )
Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall ( Observed Data Buildings 50.18.7.4.2. )
Engaging Labour For Cleaning works / Repair Works - Beldar
Engaging Labour For Dismantling works / Repair Works - Fitter Grade 2
Engaging Labour For Maintenance works / Repair Works Carpenter
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, For all leads including all lifts involved. ( D S R 2016 15.60 )
Supplying fabricating and fixing in position Sales counter with Granite / Glass top of 80 CM TOP WIDTH AND HEIGHT 80 CM ( AV ) ,made with frame work of 16 mm BWR ( IS 303 GRADE ) Plywood including covering the front and SIde , Providing inside Racks using 16 mm BWR ( IS 303 GRADE ) Ply wood, Covering all the expsed surface with 1.00 mm thickness decorative Laminated sheet of approved brand with suitable adhesive ( HEATEX or equvqlent ), the inside of the counter being painted with synthetic enamel paint 2 coat over one coat of wood primer and putty leveling, filling etc. Providing 12 mm thic edge polished glass/ 18 mm thick egde polished Granite for the Top area with necessary glass caps or adhesives, providing 8 mm thick edge polished glass for the front vertical area with suitable D brackets , Finishing including polishing all the exposed area complete as per the approved drawings and direction of the Engineer in charge.. ( OBSEVED DATA od3_P100001/2019-2020 )
Supplying fabricating and fixing in position Sales counter with Granite / Glass top of 60 CM TOP WIDTH AND HEIGHT 80 CM ( AV ) ,made with frame work of 16 mm BWR ( IS 303 GRADE ) Plywood including covering the front and SIde , Providing inside Racks using 16 mm BWR ( IS 303 GRADE ) Ply wood, Covering all the exposed surface using 1.00 mm thickness decorative Laminated sheet with Texture Finish of approved brand with suitable adhesive ( HEATEX or equvqlent ), the inside of the counter being painted with synthetic enamel paint 2 coat over one coat of wood primer and putty leveling, filling etc. Providing 12 mm thic edge polished glass/ 18 mm thick egde polished Granite for the Top area with necessary glass caps or adhesives, providing 8 mm thick edge polished glass for the front vertical area with suitable D brackets , Finishing including polishing all the exposed area complete as per the approved drawings and direction of the Engineer in charge.. ( OBSEVED DATA od3_P100001/2019-2020 )
Supplying fabricating and erecting cash cum packing counter of 1 M height (av) with width and length 70 to 90 cm and 160 cm respectively by using PINCODA or similar wood scantling of size 50x50 mm framed to form a box covered 16 mm B W R plywood round and top with 12 plain glass and the secound hight counter portation providing granite or marble (jet black or galaxy) over 9 mm thick plywood cupboard drawers with locking arrangement foot rest. Space for UPS CPU etc. and the edges of the granite being rounded and the exposed rack faced being painted to coat over a primer coat after applying putty levelling filling etc. complete as per the approved drawings and direction of the Engineer in charge.
Supplying and fixing Modiguard or Equivalent Brand glass Mirror over Frame work of 16 mm BWR Quality IS 303 Grade Play wood frame and covering the rear side with 12 MM BWR plywood and finishing all the exposed surface with 1.00 mm Thickness Decorative Laminated Sheets With Texture Finish of approved brand and shade , Fixing on Wall etc. complete as per the direction of Engineer in charge.
Providing and Fixing plywood Back ground panel made out of FRAME work using 16 mm BWR QUALITY ( IS 303 grade ) plywood at suitable spacing both horizontally and vertically, including making hole in the concrete/ masonry wall, with necessary SS hold fasts or SS screws of necessary size. Then Commercial plywood 12 mm thick B W R grade ( IS 303 Grade ) of approved make is fixed to the Exposed side of the frame work with screws of necessary size , all the exposed surface covered by 1.00mm thickness Decorative Laminated Sheets with suitable adhesive ( Heatex or Equivalent ) including sealing all the joints and holes all as per the approved drawings and Direction of the Engineer in Charge .
Providing and fixing TEAK wood frame work consisting of battens 100 x 50 mm For Fixed Glasing and Door , fixed with rawl plug and drilling necessary holes for rawl plug etc. including Polishing complete. For Fixed Glased Partitions and Doors
Providing and fixing Glazing in wooden frames using 12 mm TOUGHNED Glass of approved brand in Fixed partitions and glazed shutters for doors, (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured).
Providing and fixing Display shelf for Ornamental Items ( RACK BEHIND CASH COUNTER ) with wooden frame work using Padack wood or equvalent, providing 12 mm thick water proof ply wood on rear side, covering the frame work with 16 mm water proof ply wood, covering all the exposed surface with 9 mm thick decorative teak ply wood, providing 12 mm thic edge mechine polished glass for racks with necessary supports, polishing with Laquer polish or equivalent all as per the drawing and Direction of the Engineer .
Providing and fixing Wooden Display shelf with frame work using 16 mm thick IS 303 GRADE BWR Plywood , covering the frame work with 16 mm thick IS 303 Grade BWR Quality ply wood, covering all the exposed surface with 1.00 mm thickness decorative laminated sheet with Texture Finish using good quality addhessive ( Heatex or Equivalent ) providing 12 mm thick edge mechine polished glass for racks with necessary supports, all as per the drawing and Direction of the Engineer .
Providing and Fixing plywood RAISED PLATFORM ( 12 CM ) made out of FRAME work using 16 mm BWR QUALITY ( IS 303 grade ) plywood at 45 CM C/C spacing both ways and fixing the same to floor with necessary SS hold fasts or SS screws of necessary size. Then Commercial plywood 18 mm thick B W R grade ( IS 303 Grade ) of approved make is fixed to cover the frame work with screws of necessary size including sealing all the joints and holes all as per the approved drawings and Direction of the Engineer in Charge .
Providing and fixing KHADI SHELF ( Horizontal Spacing 90 cm and vertical Spacing 30 cm ) with stainless steel ( Grade 202 ) Hollow tubes, channels, plates etc., and 8 mm Glass , including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the Shelf to the Wall / Columns with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., Providing 8 mm Glass of of required size, including polishing the exposed edges , all as per the Drawing and approval of the Engineer-in-charge,
Providing and fixing Glazing in Aluminium Partitions door, window and ventilator shutters etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With TOUGHNED GLASS panes of 12 mm thickness
Providing and fixing DISPLAY SHELF , Horizontal Spacing 90 cm and vertical Spacing 45 cm with 40 MM AND 25 MM M S Hollow tubes, channels, plates etc., and 8 mm Glass , including welding, grinding, providing 2 coats of primer and 2 coat of Epoxy Paint ( SPRAY fiNISH ) etc complete, including fixing the Shelf to the Wall / Columns with necessary accessories & stainless steel dash fasteners , Providing 8 mm Glass of of required size, including polishing the exposed edges , all as per the Drawing and approval of the Engineer-in-charge,
Providing M S DISPLAY RACKS in Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding grinding and bolted with special shaped washers etc. complete. Hot finished welded type tubes ( D S R 10.16.1 )
Providing and fixing 8.00 mm thick Float Glass panes as racks in MS Display Racks , Display Stand including grinding and polishing the exposed edges etc complete as per the architectural drawings and the directions of Engineer-in-charge
Providing Texture Work in Wall , Ceiling with approved brand and Design as approved by the Engineer in charge.
Providing and Fixing WALL PAPER OF APPROVED BRAND AND DESIGN as approved by the Engineer in Charge.
Providing and Fixing CARPET FLOORING by with good quality and texture carpet including cost of all materials and labour as per approved Design
Providing Name Board by Vinyle Sticker Work on Existing ACP PANNEL WORK as per approved Design
Engaging Labour for Maintenance work Electrician
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. GROUP B ( D S R ELECTRICAL 1.10.2 )
Wiring for Twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with 2 Way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( D S R ELECTRICAL 2016 1.11 )
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required ( DSR Eectrical 2018, 1.55.3 )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings
SUPPLY AND FIXING 1200 MM BATTEN LED LIGHT 20 WATTS WITH ALL NECESSARY FITTINGS ( od15443/2021_2022 )
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. ( OD ELECTRICAL 90.4.8 )
SUPPLY AND FIXING 250 MM EXHAUST FAN WITH NECESSARY FITTINGS ( od15434/2021_2022 )
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 MM ( D S R ELECTRICAL 1.21.1 )
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 MM ( D S R ELECTRICAL 1.21.2 )
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm ( D S R ELECTRICAL 1.17.3 )
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm ( D S R ELECTRICAL 1.17.12 )
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm ( D S R ELECTRICAL 1.17.21 )
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 4 x 6 sq. mm ( D S R ELECTRICAL 1.17.31 )
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes - 3 core 2.50 sq mm ( OD Eelectrical 90.6.5.12 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) ( D S R ELECTRICAL 1.27.1 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm) ( D S R ELECTRICAL 1.27.2 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 4 Module ( 125 mm X 75 mm ) ( D S R ELECTRICAL 1.27.3 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 6 Module ( 200 mm X 75 mm ) ( D S R ELECTRICAL 1.27.4 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 8 Module ( 125 mm X 125 mm ) ( D S R ELECTRICAL 1.27.5 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm) ( D S R ELECTRICAL 1.27.6 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch ( D S R ELECTRICAL 1.24.1 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Two Way 5/6 amps switch ( D S R ELECTRICAL 1.24.2 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch ( D S R ELECTRICAL 1.24.3 )
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 32A DP switch with indicator ( OD Electrical 90.10.3.15 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet ( D S R ELECTRICAL 1.24.4 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet ( D S R ELECTRICAL 1.24.5 )
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. ( D S R ELECTRICAL 1.26 )
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. ( OD Electrical 90.4.1 )
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required 1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C ( OD Electrical 90.4.5.2. )
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 12 way, Double door ( OD ELECTRICAL 9.10.1.10 )
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole ( D S R ELECTRICAL 2.10.1 )
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required ( D S R ELECTRICAL 2.11 )
Supplying and fixing following rating, Four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps ( D S R ELECTRICAL 2.13.2 )
Supplying and fixing following rating, Four pole, ( Three phase and neutral), 415 volts, Residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps ( D S R ELECTRICAL 2.15.3. )
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required ( DSR Electrical 2018 5.2 )
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. ( DSR 2018, Eectrical ,5.17 )
Providing and fixing Flexi LED Strip for Cove Lighting 12 W with suitable Drive of aproved brand ( Wipro / Bajaj / Philips Or Eqivalent. )
Supply, conveyance installation testing and commissioning of Sleek Compact Recess Mounting LED Slim Panel light fitting 3W/4W , square or round, Cool or Warm , size 75 mm ( or nearest available ) with light Weight Body, energy efficient drive ,complete with all accessories , fixing directly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required.
Supply, conveyance installation testing and commissioning of Sleek Compact Recess Mounting LED Slim Panel light fitting 6 W , square or round, Cool or Warm , size 105 mm ( or nearest available ) with light Weight Body, energy efficient drive ,complete with all accessories , fixing directly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required.
Supply, conveyance installation testing and commissioning of Sleek Compact Recess Mounting LED Slim Panel light fitting 12 W , square or round, Cool or Warm , size 155 mm ( or nearest available size ) with light Weight Body, energy efficient drive ,complete with all accessories , fixing directly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required.
Supply, conveyance installation testing and commissioning of Sleek Compact Recess Mounting LED Slim Panel light fitting 18 W , square or round, Cool or Warm , size 205 mm ( or nearest available size ) with light Weight Body, energy efficient drive ,complete with all accessories , fixing directly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required.
Supply , conveyance, installation, testing and commissioning Wall mounting fan of 400 mm Sweep with Oscillation system and Pull Cord, using mounting brackets supplied along with the fan and giving connection with existing wire.
Supplying installation testing and commissioning of 2 Ton Split Air conditioner ( INVERTOR AC ,FULL COPPER ) with remote control of make Voltas / Blue Star / L.G /.Carrier or equivalent make with 1 unit of Voltage stabilizer ( V Guard VG 500 Stabiliser or Equivalent approved make suitable for 2 Ton invertor AC ) , providing angle iron / Wall Munting Bracket support to the out door and indoor unit , copper tube, cable etc complete. including cutting and making good of the masonry wall / concrete as directed by the Engineer in Charge .
Supplying and drawing following sizes of CC TV CABLE in the existing surface / recessed steel/ PVC conduit as required. - 3 +1 CC TV CABLE PURE COPPER OF BRAND D LINK OR EQUIVALENT BRANDS APPROVED BY THE ENGINEER IN CHARGE.
Providing and Fixing 18 mm thick Gang Saw cut mirror polished pre moulded and pre polished machine cut Granite for kitchen platforms, Stair and Steps, Vanity Counters, Window Sills, Facia and similar ocations of required size, approved shade , colour and texture laid over 2 part High Strength Tile Adhhessive grout ( Flex Grey of Ardex Endura or Equivalent Brand ), joints treated with white cement , mixed with matching pigment, epoxy touch ups , including rubbing and curing, moulding and polishing of edges to give high gloss finish etc ( modified 2018 DSR 8.2.2.2 )
Supplying and Fixing 160 mm UPVC Rain Water Gutters of Approved Brand ( Euro Guard or Equivalent ) with Suitable GI Clamps Fixing to the roof with necessary welding , providing necessary Drops ( Corner , End, or Running ) , Center Joint, End Cap Etc for Rain Water Harvesting including all necessary screws for fixing the Gutters all as Directed By the Engineer in Charge
Supplying and Fixing Openable Glass door lock of approved quality and make (EBCO OR EQUIVALENT ) with all necessary accessories etc complete. od20254/2024_2025
Providing and fixing 10 mm thick Float Glass Panes as Racks in MS Display Shelves including grinding and polishing the exposed edges etc complete as directed by the Engineer in Charge
Providing and fixing 12 mm thick edge Polished float glass as counter tops in existing counters using Glass caps with necessary screws
Supplying , installing , testing and commisioning CC TV System with CCTV CP PLUS 2.40 MP MIC BULLET TC24PL2C - V3-0360 / CP PLUS 2.40 MP MIC DOME TC 24 PL 2C - V3- 0360 CAMERA 6 NOS , CP PLUS 8 CHANNEL 2.4 MP DVR CP UVR -0801E1-IC , remote, channeling, playback, motion, mobile imaging, 1 unit, WITH 1 no 12 V 5 AMPS CP PLUS SMBS POWER SUPPLY , THOSHIBA 4 TB HARD DISK DRIVE , BNC / DC Cable Connecters - 18 nos, PVC CCTV COBOX 6 NOS , 1 no 22 " LED Monitor SAMSUNG ( ips Borderless ) , including installation and DVR configaration Charges , Excluding Cabling Charges
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar ( D S R 2018 , 15.7.4 )
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in Charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) ( D S R 2018 , 15.2 . 1 )
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm ( D S R 2016 , 15.23.1 )
Dismantling doors, windows and clerestory windows (steel or wood) shutter including Chowkhats, architrave, hold fasts etc complete and stacking within 50 metres lead Of area 3 sq. metres and below ( D S R 15.12.1. )
Dismantling Aaluminium / Gypsum Partitions, doors, windows, Fixed glazing and False ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. ( D S R 15.57 )
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. ( D S R 2016, 15.56 )
Engaging Labour for Maintenance work or Repair Works ( Beldar )
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : - 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). ( 2016 D S R 4.1.5 )
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) (2018 D S R , 4.1.3. )
Providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) up to floor five level excluding the cost of centering, shuttering, finishing for leveling coarse of floor and roof etc ( OD BUILDINGS 50.4.1.1 )
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete ( Observed Data Buildings 50.6.2.2. )
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level up to floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete ( Observed Data Buildings 50.6.2.3. )
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. ( D S R 6.38 )
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) ( 2016 D S R 13.4.1. )
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) ( D S R 2018 , 13.7.1 )
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : - With cement mortar 1:4 (1 cement : 4 fine sand). ( 2016 D S R 14.1.1. )
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. ( 2018 D S R , 8.31 )
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. ( DS R 2018, 11.37 )
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm ( D S R 11.48.2. )
Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks ( D S R 2016 18.76.1 )
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 0.1 mm), with wall thickness 2.0mm (0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-charge Extruded section profile size 48x40 mm ( D S R 9.117.1 )
Providing and fixing to Door Frame 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter). ( D S R 9. 118. 1 )
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ( DSR 2016 17.2.1)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 550 X 400 mm with a single 15 mm C.P. brass pillar tap. ( D S R 17.7.4. )
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia ( D S R 17.28.2.2. )
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete ( D S R 17.31 )
Providing and fixing uplasticised PVC connection pipe with brass unions: 45 cm length, 15 mm nominal bore ( D S R 2018, 18.21.2.1 )
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore ( DSR 2018 18.51.1 )
Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 8931 15 mm nominal bore ( DSR 2018 , 18.52.1 )
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ( D S R 18.53.1 ) 15mm nominal bore
Providing and fixing PTMT bib cock of approved quality and colour 15 mm nominal bore, 122mm long, weighing not less than 99 gms ( D S R 18.54.2 )
Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating ( D S R 18.58.2.1. )
Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge ( OD BUILDINGS 50.17.1.1 )
Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. ( 50.17.1.3 OD Buildings ).
Supplying and fixing CP Health Faucet superior quality (Jaguar or equivalent make) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. ( OD BUILDINGS 50.17.1.5. )
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 20 mm pipe 12 Kgf/cm2 ( OD BUILDINGS 50.18.8.2.1 )
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 12Kgf/cm2 - External work - Exposed on wall ( OD 50.18.9.12.1 )
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall ( OD 50.18.9.16.1 )
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall ( OD BUILDINGS 50.18.9.17.2 )
Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kgf/cm2 - External work - Exposed on wall ( OD BUILDINGS 50.18.9.18.2 )
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall ( OD BUILDINGS 50.18.9.19.2 )
Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 ( OD 50.18.9.9.2. )
Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow ( OD 50.19.9.20.1 )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow ( OD 50.18.9.20.2. )
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow ( OD 50.18.9.20.3 )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x63x63 mm dia Door Tee ( OD 50.18.9.20.6 )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl ( OD 50.18.9.20.7 )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow ( OD 50.18.9.22.1 )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 Digree Elbow ( OD 50.18.9.22.1 )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow ( OD BUILDINGS 50.18.9.22 .3 )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend ( OD BUILDINGS 50.19.9.22.4 )
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee ( OD BUILDINGS 50 .18.9.22.6 )
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Vent cowl ( OD BUILDINGS 50.18.9.22.8 )
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap ( 50.18.9.22.10 )
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling ( OD . 50.18.9.22.11 )
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore ( D S R 18.17. 1 A )
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc For pipes 100 to 250 mm diameter ( D S R 2018 , 19.21.1 )
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 610x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 ( D S R 19.30.2.1. )
Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .( D S R 14.72 )
Providing and fixing Aluminium work for Doors, Windows, Ventilators and Partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion - Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) ( D S R 21.1.1.3 )
For Shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) ( D S R 21.1.2.3 )
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4 mm thickness ( D S R 21.3.3. )
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer ( D S R 13.43.1 )
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. ( 2018 D S R, 13.99.1 )
Providing and Fixing Mosquito Proof Net For the Windows using Powder Coated ALuminium Outer Frame and Saint Gobain Fiber Glass ( or Equivalent ) Mosquito Net , including Fixing to the Existing Steel , Wooden Or Aluminium Outer Frame with suitable Hinges and Locking Arrangements and necessary screws as required, all as directed by the engineer in charge od124833/2023_2024
Providing and fixing C P Brass Shower ( 150 x 150 mm ) with Arm ( 350 mm ) of Approved Brand , 15 mm nominal bore ( od126270/2023_2024 )
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : - With cement mortar 1:4 (1 cement : 4 fine sand). ( 2016 D S R 14.1.1. )
Demilishing of Roof RCC Parapet Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. ( D S R 2018 , - 15.3 )
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin- charge. ( 2018 D S R , 15.5 )
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, For all leads including all lifts involved. ( D S R 2016 15.60 )
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer. MS Tube ( D S R 10.26.1 )
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work ( D S R 2018 , 13.52.1 )
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete . ( 2016 D S R 14.43. )
Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (Two or more coats applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface ( 2018 D S R 13.111.1 )
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : One or more coats on old work ( 2018 D S R 13.98.1 )
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : One or more coats on old work. ( D S R 13.99.1 )
Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .( D S R 14.72 )
Providing and fixing Aluminium work for Doors, Windows, Ventilators and Partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion - Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) ( D S R 21.1.1.3 )
For Shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) ( D S R 21.1.2.3 )
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4 mm thickness ( D S R 21.3.1. )
Engaging Labour For Cleaning Work , Maintenance work - Beldar
SHANUS LAL M (BID ID -2377603)
M. NASEEM RASHEED (BID ID -2377541)
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .