Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | Rejected-Technical | - | - | Rejected-Technical Techno commercially non responsive |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Tender fees and EMD submitted as Demand Draft is not valid and Bid is non responsive as per ITB clause no. 20.3 of the tender document and bid is rejected. |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
3 Feb 2023, 1:00 pmClosed
SE CANDP 2
SE CANDP 2 PTCUL Dehradun
Shifting of 132 KV Srinagar Satpuli line due to crossing of proposed 400KV DC Pipalkoti Srinagar TL under Package 3 Rudraprayag Dhanpur to 400 KV Ss Khandukhal Srinagar Between location no AP22 AP23
2022_PTCU4_47690_1
PTCUL/CandP-II/TL-09/2022-23
Open Tender
Electrical Works
Item Rate
240 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹11,800
MD PTCUL
₹2.0 L
Dehradun
27 Feb 2024
8 Aug 2022
4 Feb 2023
8 Aug 2022
3 Feb 2023
27 Aug 2022
19 Aug 2022
Amount
Part-A (Supply)
Towers
Galvanized tower with Bolts, Nuts, flat washers, pack washers & Stub including body extension, leg extension etc.
HT Steel
MS Steel
ACSR Panther Conductor
GS Earth wire 7/10 SWG
Single tension fitting for ACSR Panther Conductor suitbale for 120 KN Disc Insulator. (Complete set including Jumper cone)
Tension fitting for GS Earth wire 7/10 SWG
Disc Insulator 120 KN
Accessories for conductor & earth wire
Vibration damper for ACSR Panther Conductor
Vibration damper for GS Earth wire 7/10 SWG
Mid span compression joint for ACSR Panther Conductor
Mid span compression joint for GS Earth wire 7/10 SWG
Flexible Copper Bond
Repair Sleeve for Panther Conductor
Repair Sleeve for Earth wire
Counterpoise Earthing Set 30 mtr. Long each (4 Nos. sets for each location)
Miscellaneous Items
Danger Plate
Number Plate
Phase Plate (set of three)
Circuit Plate (set of two)
Anti - climbing device barbed wire type
Description of Work / Item(s)
Amount
Part-B (Erection)
Survey including Profiling, Tower spotting, Optimisation of Tower locations, Prepration of Tower schedule for 132 KV Line.
Check Survey including peg marking for 132 KV Line
Detailed Soil investigation at proposed tower locations
Earth work in excavation by mechanical/ manual means in benching/revetment work including disposal of surplus excavated soils as directed with all leads & lifts, disposed earth to be neatly levelled and dressed
In ordinary soil/ earth mixed with boulders
In ordinary Rock/DFR/SFR
In Hard Rock
Earth work in excavation by mechanical/ manual means in foundation pits of any size including dressing of sides, ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as backfilling or as directed, including all leads and lifts.
In ordinary soil/ earth mixed with boulders
In ordinary Rock/DFR/SFR
In Hard Rock
Filling available excavated earth (excluding rock) in sides of foundations in layers not exceeding 20 cm in depth, consolidating deposited layer by ramming and watering.
Setting of Stub at Tower Location
B Type Tower (2°-30°)
C Type Tower (30°-60°)
Concrete for foundations including all material, shouring and shuttering if any, forming, concreting and curing of water inlcuding cost of cement for M-20 i.e 1:1.5:3 mix concrete (cost of supply MS steel bar is not to be included)
Concrete for foundations including all material, shouring and shuttering if any, forming, concreting and curing of water inlcuding cost of cement for M-10 i.e 1:3:6 mix concrete (cost of supply MS steel bar is not to be included)
Erection of Tower including erection of leg extension, body extension, Tack Welding etc.
Laying, Stringing Tensioning, clamping, jointing etc. complete with ACSR Panther conductor including hoisting of insulators and fitting of vibration dampers etc. for complete route for D/C.
Laying, Stringing Tensioning, clamping, jointing etc. complete with Single Earthwire 7/10 SWG including fixing of clamps and all accessories.
Grounding work with counter poise type earthing including excavation 0.6 mtr deep and backfilling .
Installation of Tower accessories
Danger Plate
Number Plate
Phase Plate (set of three)
Circuit Plate (set of two)
Anti climbing device (Barbed wire type)
Protection work as per given below
Revetment with rough stones and random rubbles with 1:6:12 cement mortor inlcuding cost of all material, labour and T&P, excavation, back filling, levelling etc.
Cement concretting requried for bottom pad for revetment work in 1:4:8 ratio
Cement concretting requried for top of revetment walls in 1:3:6 ratio
Providing weep holes with 75 mm PVC Pipe (pressure 6 Kg/sqcm in proper slope)
MS Steel Bar for Reinforcement (including supply)
Destringing of existing conductors of complete route for D/C Panther including shifting of materials to store (Satpuli/Simli)
Destringing of existing 7/10 SWG Earth wire of complete route for D/C panther including shifting of materials to store (Satpuli/Simli)
Description of Work / Item(s)
Amount
Total Part-A (Supply ) from BoQ1 sheet WITHOUT GST
Total Part-B (Erection) from BoQ2 sheet WITHOUT GST
Add GST* Amount on (Total of Part-A + Total of Part-B above)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .