Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.2 L+₹52,251 (2.03%)Rejected-AOC H NO 96 W NO 9 WARD NO 11 UDHAMPUR PADHA GALI1 UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC L2 | |
| 3 | L3₹28.0 L+₹2.3 L (9.09%)Rejected-AOC 368 PHASE 4 SAS NAGAR MOHALI 160059 PB | S A S NAGAR | PUNJAB | 160059 | L3 | Rejected-AOC L3 | |
| 4 | L4₹31.9 L+₹6.2 L (24.2%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹32.8 L+₹7.1 L (27.7%)Rejected-AOC HM 324 PHASE IX SAS NAGAR MOHALI PB | L5 | Rejected-AOC L5 |
Tender Value
₹38.7 L
EMD Value
₹77,500
Closing Date
31 Oct 2019, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
CLEANING OF SEWAGE LINES, REPAIRS TO MANHOLES, BOUNDARY WALLS, FOOTPATH, HARDSTANDING, CHEQUERED TILES ETC INCL ALLIED CONNECTED WORKS IN SECTOR 28C, 31 A/B/C AND 47A/B AT AF STN CHANDIGARH
2019_MES_288695_1
GE (AF)/CHD/T-34/2019-2020
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Chandigarh
All as per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹77,500
Yes
1 Apr 2020
10 Oct 2019
2 Nov 2019
10 Oct 2019
31 Oct 2019
24 Oct 2019
Amount
Excavation in trenches in soft/ loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre deep for foundations etc. or for cesspits etc. and not exc. 10 Sq. m on plan and not exc. 1.50 metre in depth and getting out complete, all as specified.
Returning, filling in, of soft/ loose soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete, all as specified.
Removing excavated materials exceeding 250m not exceeding 500m and depositing where directed at a level not exceeding 1.5 metre above the starting point in soils, complete all as specified.
Demolition and breaking up drain pipes (salt grazed stone ware, AC or reinforced concrete) set in cement mortar, internal dia of pipe 150 mm, including removal of rubbish outside MoD land, complete all as specified and directed by Engineer - in -Charge.
Demolition of cement concrete (unreinforced) in ground floors and paving not exc. 15 cm thickness (below or above ground level), including removal of rubbish outside MoD land, complete all as specified.
Concrete bed to drain pipe with PCC (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates, including packing under and haunching against the sides for SGSW pipe of bore 150 mm, complete all as specified and directed by Engineer - in -Charge.
Salt glazed stone ware drain pipes Grade ‘A’ of 150 mm internal dia, laid and jointed with cement joint and tested, complete all as specified and directed by Engineer - in -Charge.
Cutting into existing manholes for connecting new drains, pipe of size 150 mm dia pipe making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4), type B-1, smooth finished and reforming benching as required complete all as specified and directed by Engineer - in -Charge.
Cleaning of underground sewage lines upto 150 mm bore including manhole, any depth, taking off & refixing of manhole covers, getting out all foreign matter such as solid/ liquid/ mud etc. and removing the same outside MoD land, complete all as specified and directed by Engineer - in -Charge.
Cleaning of underground sewage lines of 150 mm bore by excavation and breaking (minimum two length) and removing the blockage, laying new pipes, re-jointing with old pipes including haunching the new pipes with PCC (1:3:6), type C-2, using 40 mm graded aggregate in all situations where cleaning is not possible otherwise including returning, filling and disposal of surplus soil etc., complete all as specified and directed by Engineer - in -Charge.
Removing blockage from water closet (Indian or European type), urinals, WHBs, sinks, floor/ nahni trap, including getting out solid/ liquid/ foreign matter/ mud deposited there and removing the same in a hygienic manner outside MoD land to make the sewage waste/ sludge waste flow free up to first manhole, complete all as specified and directed by Engineer - in -Charge.
Removing blockage from gully trap, including getting out solid/ liquid/ foreign matter/ mud deposited there and removing the same in a hygienic manner outside MoD land to make the sewage waste/ sludge waste flow free up to first manhole, complete all as specified and directed by Engineer-in-Charge.
Repair to floor/ nahni trap, by removing grating and applying white cement inside the waste hole upto full depth to obtain smooth finish and refixing the grating complete all as specified and directed by Engineer-in-Charge.
PCC (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates as in foundations, filling, sub base and mass concrete, complete all as specified.
Demolition of brick masonry in any position built in any cement mortar, complete all as specified.
Brick masonry with sub class B bricks straight or curved on plan exceeding 6m mean radius, built in Cement Mortar (1:4) all as specified and directed.
Brick masonry with sub class B bricks straight or curved on plan exceeding 6m mean radius (except bricks), built in Cement Mortar (1:4) all as specified and directed.
Brick masonry with sub class B bricks straight or curved on plan exceeding 6m mean radius, built in Cement Mortar (1:6) all as specified and directed.
Brick masonry with sub class B bricks straight or curved on plan exceeding 6m mean radius (except bricks), built in Cement Mortar (1:6) all as specified and directed.
PCC (1:2:4), type B-0, using 12.5 mm graded mechanically crushed stone aggregates, as in manhole benching, coping including forming channels, finishing even & smooth (using extra cement), complete all as specified and directed by Engineer - in -Charge.
Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land, complete all as specified.
Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement, complete all as specified.
Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified.
Raking out Old joints of brick work and keyed pointing to brick wall in CM 1:4 complete all as specified.
M&L for keyed pointing in cement mortar (1:4) to new brick masonry wall incl raking out joints, complete all as specified and directed
25 mm thick, PCC (1:2:4), type B-0 (12.5mm graded crushed stone aggregate) as in flooring finished even & rough to receive the bedding mortar, complete all as specified.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
First quality, Non skid ceramic joint free coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles, complete all as specified.
First quality, glazed ceramic coloured tiles, fixed in pattern of different colour tiles including border of dark shade tiles, 6-7 mm thick of size 200 mm x 300 mm, in skirting, dado with set and jointed in neat cement slurry, over and including 10 mm thick rendering of cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles, complete all as specified.
Demolition of reinforced cement concrete of any description in any position , complete all as specified.
Reinforced cement concrete (1:2:4), type B-1, using 20 mm graded mechanically crushed stone aggregates, as in precast manhole/ drain covers, complete all as specified and directed by Engineer - in -Charge.
Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending etc., and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified.
75 mm thick, plain cement concrete 1:3:6, type C-2, using 40 mm graded mechanically crushed stone aggregates, laid in 1:20 slope as in plinth protection including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/ 25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, complete all as specified. Note: The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
75mm thick plain cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in floors/hard standing, etc, laid in approved size panels, finished even and smooth without using extra cement, joints filled with mastic mortar, complete all as specified and directed.
Dismantling CI soil waste 75 mm/ 100 mm bore pipe, in any position, complete all as specified and directed by Engineer-in-Charge.
75 mm bore CI soil waste and vent sand cast pipes in any length with or without ears, with cement joints, laid in floors or fixed to walls, with and including stack clamps @ 100 cm c/c made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and directed by Engineer-in-Charge. Note: Extra over for lead joints shall be measured and paid separately.
75 mm bore CI soil waste and vent sand cast pipes in any length with or without ears, with cement joints, laid in trenches, complete all as specified and directed by Engineer. Notes: (i) Excavation and earth work shall be measured and paid separately. (ii) Extra over for lead joints shall be measured and paid separately.
100 mm bore CI soil waste and vent sand cast pipes in any length with or without ears, with cement joints, laid in floors or fixed to walls, with and including stack clamps @ 100 cm c/c made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and directed by Engineer-in-Charge. Note: Extra over for lead joints shall be measured and paid separately.
100 mm bore CI soil waste and vent sand cast pipes in any length with or without ears, with cement joints, laid in trenches, complete all as specified and directed by Engineer. Notes: (i) Excavation and earth work shall be measured and paid separately.
Cast iron bends 75 mm bore, diminishing pieces or tapers ISI marked, complete all as specified.
Cast iron bends 100 mm bore, diminishing pieces or tapers ISI marked, complete all as specified.
75 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door, complete all as specified.
100 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, with oval acess door complete all as specified.
75 mm bore cast iron branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, with oval acess door complete all as specified.
100 mm bore cast iron branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches,with oval acess door complete all as specified.
Extra over cast iron pipes of 75 mm bore and fittings if lead joint is provided in lieu of cement joint, complete all as specified.
Extra over cast iron pipes of 100 mm bore and fittings if lead joint is provided in lieu of cement joint, complete all as specified.
110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall in repairs, complete all as specified.
75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall in repairs, complete all as specified.
110 mm bore PVC (SWR) bends any radius, fixed in repairs, complete all as specified.
75 mm bore PVC (SWR) bends any radius, fixed in repairs, complete all as specified.
Cutting holes into or through brick/ concrete walls built, in cement mortar, not exceeding 150 Sqcm in superficial area and making good in cement mortar 1:3 to match with the existing finishes, complete all as specified.
SGSW gully trap 150 x 100 mm, square or round mouthed, fixed in repairs, including setting and jointing to drains with cement mortar 1:1, complete all as specified.
Cast iron floor trap 75 mm dia out let, ISI marked, with CP grating including jointing to waste pipe in run lead & fixed in PCC (1:2:4), type B-1, complete all as specified.
Grating 125 mm dia (Minimum weight 40 gms) with or without waste hole of PTMT fixed on floor/ nahani trap with white cement, fixed in repairs, complete all as specified and directed by Engineer - in -Charge.
Vitreous china squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rest, ISI marked including connecting and necessary lime concrete, fixed in repairs, including making good the surface to match with existing floor finish, complete all as specified and directed by Engineer - in -Charge.
Cast iron traps ‘P’ or ‘S’ , 100 mm bore, fixed in repairs, complete all as specified.
Dismantling structural steel work including doors, gates but excluding framed truss etc.
S/F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, sunshed etc fixed with self tapping screws as specified
S/F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
S/F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long
Framed work such as grills, gratings, for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts,with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
Dismantling of Interlocking paver block of any size or any thickness laid over sand cusion complete all as specified and directed
Material and labour, factory made, precast concrete, machine pressed, interlocking paver block any shape and size confirming to IS : 15658-2006 of 60mm thickness, M-35 Grade, with grey cement and pigment (in top layer), coloured, laid over and including 25mm thick fine sand cushioning and joints filled with fine sand, complete all as specified and directed. Note: Rate includes supply and spreading of sand.
Material and labour, coloured glosey finished, rubber moulded chequered cement concrete tiles 400 mm x 400 mm x 25 mm thick, factory made, ISI marked (IS 13801-1993), laid with neat cement slurry @ 3Kg/Sqm over & including 20mm thick screed bed of cement mortar (1:6), pointed in white cement with matching colour pigment, complete all as specified and directed.
Material and labour plain cement concrete (1:2:4), type B-1 (using 20 mm graded mechanically crushed stone aggregates) as in mud stops, sides of interlocking paver blocks and similar work, finishing the surfaces even and smooth without using extra cement , complete all as specified and directed.
Taking down hanging mild steel gate not exceeding 1.50 Sq.m each and refixing in the same opening after carrying out necessary repair work with welding such as change of rusted hold fast, hinging device, pintol, pivotel and locking arrangement, PCC of hold fast etc. complete all as directed by Engineer-in-charge.
M&L cutting hole in brick wall built in cement mortar exc half brick but n.exc one brick wall inserting holdfast and making good dismentaled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as directed by Engineer-in-charge.
M&L for preparation of new surfaces of steel and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified
Preparation of old painted steel or iron surfaces over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified.
Preparation of new wall surfaces plastered or unplastered and applying two coat of cement base paint, complete all as specified and directed.
M & L preparation of old plastered surfaces of walls & applying one coats of cement base paint , complete all as specified.
S&F in repairs vitreous china wash down water closet (pedestal pattern), white (including fixing bolts) including plastic seat cover white and mild steel chromium plated aluminum hinging devices, pedested pan and trap including connected to drain and flushing pipe, anti-syphonage pipe etc. complete including making good to floor complete all as specified and directed
S&F in repairs 10 liters capacity, PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete all as specified and directed.
Note against Sl Item No 8 to 13 : The contractor's representatives will report daily on working days at the MES complaint cell at Sector 47 Chandigarh to collect the sewage blockage complaints and petty repairs compliants from MES supervisory staff. Sewage blockage and minor complints shall be rectified on same day and completion report after rectification will be submitted duly signed by the occupant upto 1700 hrs at the MES complaint cell. In case he fails to clear the sewage blockage within 08 hours, a penalty of Rs 50/- per day complaint shall be imposed on contractor and shall be recovered form his dues till teh sewage blockage is cleared. the same penalty will be imposed in case the contractor or his representaive fails to report in complaint cell in the morning, in addition to the pending complaints of that day.
Note:- Amount of credit of Rs. 55546.00 for retrieved materials is mentioned in Schedule of Credit Page No 112 of tender documents in pdf form which will be deducted offline while acceptance of tender
M/S V K Construction Co
Baba Engineers and Contractors
M/S GOYAL ASSOCIATES
M/S MATLOOB AHMED
MOHAMMAD RASHID
MS FUTEC ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .