| Sl No | Description | Qty | Unit | Alchem Industries L3 | M A JAMES, Mannasseril L1 | VIJAYAN ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00Suitable for handling saline and silty water with rpm 960 (Sync) or less. The material of construction of flange, suction bell, bowl, shroud shall be CI with 2% Nickel. Impeller, Shaft, shaft sleeve, fastener shall be of SS 304. Suction pipe and Delivery pipe should be in SS 304 with minimum thickness 6 mmand of suitable length (varies from 4-10m) or as per site condition. The prime mover of the pump is to be 3 phase TEFC squirrel cage induction motor of reputed make having star rating above4 operating at 415V +/- 10%, 50 Hz +/- 5% connection with F class insulation, control panel must have dust and vermin proof vertical mounted cubical type panel board of reputed make with FCMA soft starterofreputed make, MCCB including phase failure protection, surge protection device, dry run protection, overload over current protection, thermal overload protection relay, earth fault relay, voltmeter-ammeter fault indication, start and stop switches and power factor correction capacitor etc. Wiring and earthing should be as per regulations of KSEB and electrical inspectorate. Separate cubical type energy meter panel with CT metering provision including 4 Pole FN type isolator, RCCB , HRC fuses and carrier. Suitable size Copper cable for connection from electric post to meter box and meter panel to motor control panel etc. should be fitted at site, with proper earthing. Cable termination should be as per the regulations and specifications of KSEB and Electrical Inspectorate standards. Screen with 6mm GI welded mesh with 50 mm x 50 mm opening size (about 20 sq.m area) framed in GI angles and GI tubes fitted at the opening on top and sides of sump to prevent entry of unwanted materials to the pump through inflow water. Proper I-section should be provided for supporting the motor mountings and pedestal. Suitable chain block and tripod facilities to be provided for lifting the motor at least 1.00 m above maximum flood level. Rate quoted should be inclusive of all the charges for supply, installation including trial run and commissioning, all types of transportation and conveyance, loading and unloading charges, charges for factory testing, but excluding GST etc. | ||||||
| 1.01 | Duty Point Head (m): 2.5
Working Range (m): 0.5m to 3.5m
Minimum discharge at Duty Point Head (lps): 912
Minimum overall efficiency at duty point (%) : 60
Available Connected Load: 50 Hp | 3 | Nos | 66,42,000 ₹66,42,000 | 46,92,000 ₹46,92,000 Lowest | 54,45,000 ₹54,45,000 |
Tender Value
₹60 L
EMD Value
₹60,000
Closing Date
29 Jul 2026, 6:00 pmClosed
EE Agri Alappuzha
O/o EE Agri Alappuzha
Retender Supply erection, testing and commissioning of Vertical Axial Flow pump set (Non-Submersible) for various padashekarams under Cherthala Legislative Assembly Constituency of Alappuzha
2026_AGRI_853337_2
ADFW/EXE/ALP/53/2026-EE2
Open Tender
Equipments
Item Wise
30 days
Cherthala Alappuzha
Please refer Tender documents.
6 documents required · 6 mandatory
₹12,000
Yes
₹60,000
Yes
14 Sept 2026
16 Jul 2026
31 Jul 2026
16 Jul 2026
29 Jul 2026
16 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Suitable for handling saline and silty water with rpm 960 (Sync) or less. The material of construction of flange, suction bell, bowl, shroud shall be CI with 2% Nickel. Impeller, Shaft, shaft sleeve, fastener shall be of SS 304. Suction pipe and Delivery pipe should be in SS 304 with minimum thickness 6 mmand of suitable length (varies from 4-10m) or as per site condition. The prime mover of the pump is to be 3 phase TEFC squirrel cage induction motor of reputed make having star rating above4 operating at 415V +/- 10%, 50 Hz +/- 5% connection with F class insulation, control panel must have dust and vermin proof vertical mounted cubical type panel board of reputed make with FCMA soft starterofreputed make, MCCB including phase failure protection, surge protection device, dry run protection, overload over current protection, thermal overload protection relay, earth fault relay, voltmeter-ammeter fault indication, start and stop switches and power factor correction capacitor etc. Wiring and earthing should be as per regulations of KSEB and electrical inspectorate. Separate cubical type energy meter panel with CT metering provision including 4 Pole FN type isolator, RCCB , HRC fuses and carrier. Suitable size Copper cable for connection from electric post to meter box and meter panel to motor control panel etc. should be fitted at site, with proper earthing. Cable termination should be as per the regulations and specifications of KSEB and Electrical Inspectorate standards. Screen with 6mm GI welded mesh with 50 mm x 50 mm opening size (about 20 sq.m area) framed in GI angles and GI tubes fitted at the opening on top and sides of sump to prevent entry of unwanted materials to the pump through inflow water. Proper I-section should be provided for supporting the motor mountings and pedestal. Suitable chain block and tripod facilities to be provided for lifting the motor at least 1.00 m above maximum flood level. Rate quoted should be inclusive of all the charges for supply, installation including trial run and commissioning, all types of transportation and conveyance, loading and unloading charges, charges for factory testing, but excluding GST etc. | |||||
| 1.01 | Duty Point Head (m): 2.5
Working Range (m): 0.5m to 3.5m
Minimum discharge at Duty Point Head (lps): 912
Minimum overall efficiency at duty point (%) : 60
Available Connected Load: 50 Hp | 3 | Nos | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.47 MB
ann2.pdf
Tender Documents • 0.22 MB
ann1.pdf
Tender Documents • 0.18 MB
BOQ_1455411.xls
BOQ • 0.30 MB
nit.pdf
Tender Documents • 0.46 MB
KFC14.pdf
Tender Documents • 0.22 MB
bb.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .