Tender Value
Refer Docs
EMD Value
₹3,902
Closing Date
27 Jun 2024, 5:00 pmClosed
Assistant Executive Engineer
O/o Assistant Executive Engineer Electrical Wing Irrigation Sub Division Aluva
GENERAL Repair works in RCB AMC 2024 25 Fully Comprehensive Annual Maintenance Contract of Shutter Motors and other connected Electrical installations at Purapallikavu and Manjummel RCBS under Electrical LI Section Aluva General Electrical Work
2024_Irrig_676696_1
PWD/ALY/BLDG/1519/2024-2025
Open Tender
Electrical Works
Item Rate
365 days
Kalamassery
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
₹3,902
31 Jul 2024
19 Jun 2024
29 Jun 2024
19 Jun 2024
27 Jun 2024
19 Jun 2024
Amount
Electrical Maintenance works at Manjummel RCB
OD48854/2024-2025: Annual maintenance of all panels Main panel and Motor control panel - and starter panels and DBs which inlcudes periodical cleaning of panel with blower and Checking and tightening of cable terminations of all the incoming & outgoing feeders of all the panels. Checking & tightening of all the control cables of panels and .Checking the proper operation of switch gear items and attending all the minor repairs like changing damaged beeding and smc sheets and changing damaged knobs of all switch gear compartments and changing led indicators and push buttons and changing cont actors and relays in starter panel and voltmeters and ammeters and fuse links and Switch gears if needed ( excluding supply of ammeters and volt meters and indicators conatctors and relays) )and checking earth connection, attending repairs to all the compound lights including street light and flood lights including checking the fault and attending minor repairs( excluding fittings), Servicing of stand alone street light in the bridge approach road premises which includes cleaning of panel for removing dirt and dust and checking Connection and refilling the battery water in the existing DGs batteries ensuring trouble free opeartion for a period of 12 months .
OD139992/2023-2024:Supply and providing cylindrical type 20 fuse link suitable for FN63 switch unit
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
OD152231/2023-2024:Supply and providing LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour
OD152232/2023-2024:Supply and providing LED indicators for all voltage ranges - Blue Colour
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD48908/2024-2025:Supply & installation of dust and vermin proof, wall mounting, Sintex box of following size 250*250* 160 GSMB 2525 suitable for fixing double pole isolator etc,
OD52809/2024-2025: Supply and renewal of 3 phase digital Voltmeter accuracy class 1 in panel board after dismantling existing damaged one ( L & T Make or equivalent )
OD52837/2024-2025:Supply and renewal of Three Phase digital Ammeter accuracy class 1 in panel board after dismantling the damaged one, L&T or equivalent make.
OD52843/2024-2025:Charges for scraping , cleaning , painting the existing rusted panel board and dismantling the burnt out wire connection of switches ,cleaning the terminals , painting two coats of enamel paint over a coat of red oxide primmer and making the panel board ( including the naming of separate switches marking ) in good working condition
OD52878/2024-2025: Carrying out control wiring for panel with normal meters and indication lamps for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.-1.50 sq mm single run with required sockets.
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor
lectrical Maintenance works at Manjummel RCB Office Building
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.20.3:Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD52932/2024-2025:Supply and providing 7W LED Bulb
OD52952/2024-2025:Supply & installation of dust and vermin proof, wall mounting, Sintex meter box of following size suitable for fixing KSEB energy meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.Sintex (GSMB 4030) 400 x 300 x 190 mm
OD52970/2024-2025: Supply , Conveyance and fitting 63 HRC Fuse Base with suitable HRC Fuse link in the existing Meter box.
Electrical Maintenance works at Purapallikavu RCB
OD151732/2023-2024:Supply & fixing BS type fuse links20A to 32A Clip-on Off set tag type of size F1
OD151743/2023-2024:Supply and fitting 12 A, 3 pole power Contactors (For 7.5 HP motor), AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC approved make giving connections etc. as required.
OD152545/2023-2024:Supply and fitting 25 A, 3 pole power Contactors (For 15 HP motor), AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC approved make giving connections etc. as required.
OD151760/2023-2024:Supply and fitting front mounting add on Auxiliary contact Block 1 NO + 1 NC for starters approved make giving connections etc. as required.
OD151768/2023-2024:Supply and fixing over load Relay of L & T make MN 2, 24-40 A, suitable to direct mounting on MNX 9-40 or equivalent
rewinding
OD48835/2024-2025:Disconnect all electric connections from the motor , decoupling the motor from shutter operating gear system and remove the base bolts from motor and base plate and kept the motor at safe place , checking and testing the stator and rotor winding. power greater than 3hp and up25 HP,leading the motor to the nearest roadside using manpower, rope , chain, reaper etc. as required without getting damages to the motor, including loading into the vehicle and unloading at workshop for repairs and to and fro Conveyance.including resetting, refitting, coupling with shutter gear system, giving connection, taking trial run with full load etc. complete
OD52781/2024-2025:Charges for rewinding the burnt rotor/stator - separate stater and rotor/stator, dismantling the damaged rotor/stator winding from the rotor/stator slots, cleaning the slots neatly, insulating the slots with correct class of insulating paper, winding the rotor/stator with good quality correct gauge of super enamelled copper winding wires, closing the rotor/stator slots with fibre wedges, putting proper inter layer insulation, connecting the coil end connection, providing new rotor/stator lead wire, steel binding the overhang with proper insulation at both ends, heating the coils and varnishing with good quality insulation varnish, keep it for drying, reassembling and test running(Less scrap copper)
FRANCIS PINHERO
Bidder Name
FRANCIS PINHERO
JEFRIN PINHERO
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1052235.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .