Loading…
Loading…
Tender ID
Tender Value
₹49.3 L
EMD Value
₹98,505
Closing Date
8 Apr 2026, 4:00 pmClosed
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
Engineering complex rajbagh near silk factory srianagar
Construction of Mini Secretariat at Kokernag Phase II (Electric Part)
2026_PWDJK_306862_1
NIT No.330/2025-26 Dt/27/03/2026
Open Tender
Electrical Works
Percentage
Kokernag
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,100
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹98,505
27 Mar 2026
27 Mar 2026
9 Apr 2026
27 Mar 2026
8 Apr 2026
27 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Wiring for lighting points/fan points/ exhaust fan points/call bell points with 1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch , modular plate and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ Finolex/KEI/RR or
equivalent make ) excl. cost of conduit. | 467 | no | - | - |
| - | Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing, etc. as required. (Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or
equivalent ) excl. cost of conduit | 800 | mtr. | - | - |
| - | Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/
ABB/Schneider or equivalent) | 70 | no. | - | - |
| - | Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 2 no. 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/
ABB/Schneider or eq.) | 70 | no. | - | - |
| - | Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent)
3 pin 5A - 10A socket. | 50 | no. | - | - |
| - | Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent)
ii. indicator. | 50 | No | 100 | ₹5,000 |
| - | Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires of Havells/ Polycab/ Anchor/ Finolex/KEI/RR make in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) excl.
cost of conduit | 800 | mtr. | - | - |
| - | Supply, installation, testing and commissioning of 12 Watt to 15 watt LED recessed/ mounted (round or square) Down lighters having aluminum body, minimum 100im/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India , Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department.
(Havells/ Philips/ Crompton/ Jaguar/Wipro). Commercial series. | 174 | no. | - | - |
| - | Supply, installation, testing and commissioning of 18 Watt LED recessed/ mounted (round or square) Down lighters having aluminum body, minimum 100im/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India , Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department.
(Havells/ Philips/ Crompton/ Jaguar/Wipro). Commercial series. | 85 | no. | - | - |
| - | Supply, installation, testing and commissioning of 10 Watt (2 feet long) LED wall mounted batten ( tube lights) having aluminum housing, minimum 100im/w, average life 50000 hours (Commercial series) The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of one year reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/
Jaguar/Wipro). | 50 | no | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.83 MB
BOQ_996045.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .