O/o Assistant Executive Engineer Electrical Wing (I) Sub division, Aluva
GENERAL-Lift Irrigation HT Maintenance Work-Urgent Replacement of CT PT Unit And TOD Meter at Pampakkuda Relift L I Scheme under Electrical Lift Irrigation Section Ramamangalam
2022_Irrig_531606_3
PWD/BLDG/TR/7209/2022_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
Aluva
The Bidder must have a valid HT Licence
10 documents required · 10 mandatory
₹640
₹7,216
16 Jun 2023
5 Apr 2023
26 Apr 2023
5 Apr 2023
24 Apr 2023
5 Apr 2023
5 Apr 2023 - 22 Apr 2023
Amount
Replacement of Metering Equipment at Pampakkuda Relift LI Scheme
OD19082/2022-2023:Dismantling the existing damaged TOD meter and CT PT unit after Isolating the HT 4 pole structure, Earthing the HT Terminals using earthing chain, and taking all safety measures and stacking at yard as per the direction of the departmental officers at site.
OD19080/2022-2023:Supply, conveyance, erection testing and commissioning of approved make 3 phase, 4 wire, 110 V ( L-L), -/1 A CT or -/5A CT with DLMS compliant, having RS 485 port of class 0.2 S class TOD meter in the existing meter box after submitting the test certificate from KSEB TMR Division, giving all connections etc. as required. (excluding testing fees)
OD19079/2022-2023:Supply, conveyance, erection testing and commissioning of approved make 11 KV, out door metering CT PT unit wit 3 CT ratio 10/5A to 50/5A 10/15 VA, class 0.2 S class and PT ratio 11 KV/110 V , 25 VA, class 0.2 class , suitable for 3 phase 4 wire system of metering (the unit shall be tested in KSEB TMR division and test certificate should be submitted before installation) erecting the same in cross arm channel support with all standard accessories, giving connections as required. including conveyance charges to & fro for testing , after dismantling the damaged one
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
OD19077/2022-2023:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armored copper control cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 10 core 2.5 sq mm with factory made clamp
OD164209/2022-2023:Supply,Errection, testing and commissioning of 3 phase 4 wire screw type test terminal block for interconntion.
OD165680/2022-2023:Supply and providing polymer type 11 KV AB switch with handle set fixed on the existing MS channel frame work.
OD165684/2022-2023:Supply, conveyance, fitting and commissioning of approved make polymer 11 KV, thyrite type lightning arrester with accessories on cross arm including giving connections etc. as required.
HT Maintenance work at Kaliyar Pindikayam LIS
OD164283/2022-2023: Isolating the 400 KVA Transformer from HT Line after taking permission from KSEB authorities, Earthing the HT Terminals of the transformer, using earthing chain, and taking all safety measures, Scrapping, cleaning the surface of the transformer, painting the surface with enamel paint, over a coat of zinc rich primer as per the direction of the departmental officers at site.
OD164284/2022-2023: Isolating the HT 4 pole structure, after Earthing the HT Terminals using earthing chain, and taking all safety measures, Scrapping, cleaning the surface of the all metal poles, supporting members,Yard fencing structures, etc cleaning the surfaces, painting with 2 coats of enamel paint, over a coat of zinc rich primer as per the direction of the departmental officers at site.
OD164327/2022-2023:Isolating the 11 kV supply to the 4 pole structure, earthing using earthing chain, taking all safety measures, attending Minor repairs to the electrical connections of the 11 KV four pole structure such as correcting loose connections in the jumpers, lead wires re arrangement of the existing accessories including using necessary copper wires of adequate size, and correcting the system in good condition
OD164335/2022-2023:cutting and removing the grass / bushes/ creeping plants in the transformer yard, and dumping them in convenient place and cleaning the yard from all other vegetation growth as per the direction of departmental staff at site
13.10:Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
13.11:Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
OD164285/2022-2023:Supply & Providing Silical gel breather for 400 KVA transformer
OD164346/2022-2023:Supply conveyance and laying 40 mm size broken stone in the ground of HT yard as required
Bidder Name
Linsta Services
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_842900.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .