23/2025-26/CORE/ELEC/JAL(AI) DIV Gr No-1 Renovation and Upgradation of Electrical System of Departmental Inspection Bungalow of WRI and DD at Jalpaiguri in the District of Jalpaiguri under the Executive Engineer AI Jalpaiguri AI Division under Core
2026_WRDD_1013925_1
23/2025-26/CORE/ELEC/JAL(AI) DIV Gr No-1
Open Tender
ELECTRICAL WORKS M/R
90 days
JALPAIGURI
Please refer Tender documents.
3 documents required · 3 mandatory
₹14,100
20 Mar 2026
25 Feb 2026
7 Mar 2026
25 Feb 2026
5 Mar 2026
25 Feb 2026
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment a) Legrand,6 way,
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. a) Legrand, 4 Pole, FP 63 Amp.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. a) Legrand, 2+12 way
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. a) Legrand, 6-32 A
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. a) 63Amp. DP Isolator
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. a) Legrand, 125 Amp
Supply of followinf PVC Armoured Aluminium cable from MCCB to TPNBDB in ADM Bldg. and Transormer to Bungalow Panel Board. a) 35 sq.mm. 4 core cable, As per Price list,
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : (c) For 4 core, upto 35 sqmm
a) For 2 core,10 Sq.mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials (c) For 3.5 core, upto 35 sqmm
a) For 2 core,10 Sq.mm
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 8 way, Legrand, UPTO 160 A
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. Legrand, DP 63 Amp.
Supplying and fixing MCCB SS enclosure with IP- 20/30 protection, pwder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision for earthing attachment, Legrand,
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting,
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia. x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By G.I ,Medium Pipe
Add GST @ 18 % on ALL ITEM (EXCEPT PROCUREMENT OF MATERIALS)
Add Labour Welfare Cess @ 1%
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tendernotice_2.pdf
PDF • 0.80 MB
BOQ_2490327.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid