Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-Finance D26 ATABAGAN GARIA KOLKATA LASKARPUR GARIA SOUTH 24 PARGANAS WEST BENGAL 700084 | 24 PARAGANAS SOUTH | WEST BENGAL | 700084 | L1 | Accepted-Finance L1 among Six bidders. | |
| 2 | L2₹2.9 L+₹12,213 (4.37%)Rejected-Finance 97A GROUND FLOOR SATIN SEN SARANI KANKURGACHI KOLKATA WEST BENGAL 700054 | KOLKATA | WEST BENGAL | 700054 | L2 | Rejected-Finance L2 among Six bidders. | |
| 3 | L3₹2.9 L+₹12,331 (4.41%)Rejected-Finance | L3 | Rejected-Finance L3 among Six bidders. | |
| 4 | L4₹3.1 L+₹33,546.22 (12.0%)Rejected-Finance | L4 | Rejected-Finance L4 among Six bidders. | |
| 5 | L5₹3.2 L+₹37,795.40 (13.5%)Rejected-Finance | L5 | Rejected-Finance L5 among Six bidders. |
| Sl No | Description | Qty | Unit | Ashoka Electric Co L2 | B M INDUSTRIES L3 | M/S SINGH IMPRESSION L6 | SHARMA INDUSTRIES L5 | COMFORT ENGINEERING L4 | Polynova Equipments Co L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and laying of 2 core 1.5 Sq.mm PVC insulated PVC shed. Copper armoured cable i/c fixing in wall / surface with G.I saddle, etc. complete as reqd. | 250 | Mtr. | 20,000 ₹23,600 Lowest | 62,500 ₹73,750 | 55,000 ₹64,900 | 40,000 ₹47,200 | 62,500 ₹73,750 | 46,250 ₹54,575 |
| 2.00 | Providing and fixing 6 SWG. dia. G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable, as required. | 250 | Mtr. | 13,750 ₹16,225 | 7,500 ₹8,850 | 15,000 ₹17,700 | 7,500 ₹8,850 | 5,000 ₹5,900 Lowest | 10,000 ₹11,800 |
| 3.00 | Supplying and making of end termination by brass compression gland for 2 core 1.5 Sq.mm PVC shes. PVC insl. Ar. cable etc. complete as reqd | 50 | Nos. | 2,500 ₹2,950 | 4,000 ₹4,720 | 6,000 ₹7,080 | 2,500 ₹2,950 | 3,500 ₹4,130 | 2,250 ₹2,655 Lowest |
| 4.00 | Supply and fixing of suitable size loop box made out of fibre glass and polyester resin cast with 6 Amp. porcelain kit-kat, 2-way terminal, interconnections with suitable size copper wire, testing, etc. complete as required. [for compound lighting power feeding arrangement] (M/s, Syntex or S.S make) | 20 | Set. | 16,000 ₹18,880 | 18,000 ₹21,240 | 27,000 ₹31,860 | 22,000 ₹25,960 | 22,000 ₹25,960 | 14,000 ₹16,520 Lowest |
| 5.00 | 10 ft long, 32 mm. dia. medium class G.I pipe having 3 ft + 7 ft bending of approx. 45 digree and 3 nos. heavy duty clamp, etc. complete as required. [for LED roof light fitting.] | 15 | Nos. | 18,000 ₹21,240 Lowest | 45,000 ₹53,100 | 22,500 ₹26,550 | 21,750 ₹25,665 | 22,500 ₹26,550 | 22,500 ₹26,550 |
| 6.00 | Supply & fixing of 70 watt LED type street light fitting i/c connections, testing, checking, commissioning, etc. as required. [M/s, Philips make, Model: - BRP501 LED098 CW R3C PSU S1 or S.S BSNL approved make] | 19 | Set. | 1,04,500 ₹1,23,310 | 66,500 ₹78,470 Lowest | 1,14,000 ₹1,34,520 | 1,23,500 ₹1,45,730 | 85,500 ₹1,00,890 | 85,500 ₹1,00,890 |
| 7.00 | Supply & fixing of 150 watt LED type street light fitting i/c connections, testing, checking, commissioning, etc. as required. [M/s, Philips make, Model: - BRP504 LED210 CW R3C PSU S1 or S.S BSNL approved make] | 1 | Set. | 8,000 ₹9,440 | 6,500 ₹7,670 Lowest | 9,000 ₹10,620 | 12,500 ₹14,750 | 6,500 ₹7,670 Lowest | 7,750 ₹9,145 |
| 8.00 | Dismantling of old damaged compound light fittings i/c connections, damaged G.I arm brackets, damaged loop box, damaged cables, etc. complete as required. | 15 | Job. | 4,500 ₹5,310 | 1,500 ₹1,770 Lowest | 7,500 ₹8,850 | 3,000 ₹3,540 | 17,250 ₹20,355 | 3,000 ₹3,540 |
| 9.00 | Removing of existing conventional light fitting, modificitaion of old conventional internal wiring, making ready for LED retrofit LED light, etc. complete as required. | 10 | Job. | 4,000 ₹4,720 | 1,000 ₹1,180 Lowest | 5,000 ₹5,900 | 1,000 ₹1,180 Lowest | 1,500 ₹1,770 | 1,500 ₹1,770 |
| 10.00Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | |||||||||
Tender Value
₹4.4 L
EMD Value
₹8,727
Closing Date
16 Nov 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer (E), BSNL ED-III, Kol
Room No. 322 3rd Floor, Burrabazar Telephone Exchage, Kolkata - 700007
Providing compound lighting arrangement by energy saver LED light fittings i/c power feeding arrangement, timer control box with allied works for Sector-V Store and Exchange Building Compound, Saltlake Cluster, CTD.
2026_BSNL_296577_1
97/BSNL/ED-III/Kol/NIT/2026-27
Open Tender
Electrical Works
Item Rate
30 days
Sector V, Salt Lake, Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Yes
BSNL COLLECTION ACCOUNT AO BSNL CENTRAL COLL ACCT,
₹8,727
Yes
27 Nov 2026
2 Nov 2026
17 Nov 2026
2 Nov 2026
16 Nov 2026
4 Nov 2026
3 Nov 2026 - 14 Nov 2026
90 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and laying of 2 core 1.5 Sq.mm PVC insulated PVC shed. Copper armoured cable i/c fixing in wall / surface with G.I saddle, etc. complete as reqd. | 250 | Mtr. | - | - |
| 2 | Providing and fixing 6 SWG. dia. G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable, as required. | 250 | Mtr. | - | - |
| 3 | Supplying and making of end termination by brass compression gland for 2 core 1.5 Sq.mm PVC shes. PVC insl. Ar. cable etc. complete as reqd | 50 | Nos. | - | - |
| 4 | Supply and fixing of suitable size loop box made out of fibre glass and polyester resin cast with 6 Amp. porcelain kit-kat, 2-way terminal, interconnections with suitable size copper wire, testing, etc. complete as required. [for compound lighting power feeding arrangement] (M/s, Syntex or S.S make) | 20 | Set. | - | - |
| 5 | 10 ft long, 32 mm. dia. medium class G.I pipe having 3 ft + 7 ft bending of approx. 45 digree and 3 nos. heavy duty clamp, etc. complete as required. [for LED roof light fitting.] | 15 | Nos. | - | - |
| 6 | Supply & fixing of 70 watt LED type street light fitting i/c connections, testing, checking, commissioning, etc. as required. [M/s, Philips make, Model: - BRP501 LED098 CW R3C PSU S1 or S.S BSNL approved make] | 19 | Set. | - | - |
| 7 | Supply & fixing of 150 watt LED type street light fitting i/c connections, testing, checking, commissioning, etc. as required. [M/s, Philips make, Model: - BRP504 LED210 CW R3C PSU S1 or S.S BSNL approved make] | 1 | Set. | - | - |
| 8 | Dismantling of old damaged compound light fittings i/c connections, damaged G.I arm brackets, damaged loop box, damaged cables, etc. complete as required. | 15 | Job. | - | - |
| 9 | Removing of existing conventional light fitting, modificitaion of old conventional internal wiring, making ready for LED retrofit LED light, etc. complete as required. | 10 | Job. | - | - |
| 10Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | |||||
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
TenderDoc97NIT.pdf
Tender Documents • 1.53 MB
BOQ_345608.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .