Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹49.8 L+₹24,245 (0.49%)Rejected-AOC MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | L2 | Rejected-AOC Become L2 | |
| 3 | L3₹50.0 L+₹43,610 (0.88%)Rejected-AOC | L3 | Rejected-AOC Become L3 | |
| 4 | L4₹50.9 L+₹1.3 L (2.64%)Rejected-AOC | L4 | Rejected-AOC Become L4 | |
| 5 | L5₹51.7 L+₹2.1 L (4.30%)Rejected-AOC | L5 | Rejected-AOC Become L5 |
Tender Value
Refer Docs
EMD Value
₹79,700
Closing Date
21 Sept 2021, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Chariali Tezpur
REPAIR TO FOOTPATH, HARD STANDING DRAIN, CERTAIN MISC EXTERNAL B/R SERVICES AND OVER HAULING/REPAIRS TO COOLING APPLIANCES WORKS IN 524 UNIT AT MISA CAMP UNDER GE (S) TEZPUR
2021_MES_471887_1
8604
Open Tender
Civil Works
Item Rate
240 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹79,700
Yes
7 Dec 2021
31 Aug 2021
23 Sept 2021
31 Aug 2021
21 Sept 2021
14 Sept 2021
Amount
Demolition cement concrete n'exc 15 cm thick (below or above ground level) as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing coat), removing serviceable tiles to store and rubbish off the premesises
M & L Screed Bed or Bedding Layer 15mm thick in Cement Mortar 1:6 for laying Floor Finishes/Tiles, complete all as specified and as directed
Praparation of plastered or unplastered old surfaces of wall, chajjas, soffits of chajja, slab projection etc and applying one coat of cement base paint all as specified and as directed by Engr-in-charge
M & L for Finishing walls with Premium Acrylic Smooth exterior (weather coat) paint with Silicone additives of required shade: (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including complete removal of existing treatment complete all as specified and directed
M & L for Rendering or Bedding Layer 10mm thick in Cement Mortar 1:4 on Walls, etc. for fixing Tiles as Skirtings, Dados, etc, complete all as specified and directed.
S&F non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile 600mmx600 mm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match
S&F non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile 600mmx600 mm, in vertical surface etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match
S&F non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile 300mmx300 mm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match
S&F for colour Glazed ceramic tiles (450x350) of 7 to 8mm thick, in dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match.
Demolition of wall & ceiling Boards (fibre,pulp,insulation etc. ),or insulation board/slabs/ blankets ,any thickness, including cover fillets.
M&L for Anodised aluminium snap grid (605 x 605mm) frame work for false ceiling all as specified
S&F 6mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework complete all as directed.
Demolition of brick work or stone boulder masonary, built in CM incl all quions , arches pillars etc.
M & L for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded aggregate as in base/sub base of footpath complete
S &F glossy finished chequered cement concrete coloured tiles 22cm x 22cm x 25 mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment complete all as specified and directed.
M&L PCC (1:4:8) type D-2 using 40 mm graded stone agg as in fdn filling mass concrete.
M&L brick work using sub class B brick (old size) curved or straight in plan exc 6 mtr mean radius in cm (1:6) complete all as specified and directed
M&L brick work using sub class ‘B’ bricks (old size) straight or curved on plan to any radius in half brick work built in CM 1:4 complete all as specified.
M&L 15 mm thick plastering on other than fair faces of wall surfaces in cm (1:4) finished even and smooth without using extra cement complete all as specified and directed
M&L precast RCC cover slab Type B1 (1:2:4) using 20mm graded aggregate, set in CM (1:4) complete all as speceified and directed.
M&L for TMT bar of size 6mm to 8mm dia, cut to length bent to shape required including crancking bending spirally for hooping and binding with mild steel wire not less than 0.9mm dia complete all as specified and directed.
S&F in replacement of heating element of 2000 W (Round or Triangular Head as required at site) including rubber washer (ISI marked) etc complete all as directed
S&F in replacement of 450 mm long PVC connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15 mm dia complete all as directed.
S&F in replacement of thermostat suitable for water heater of any size/type complete all as directed.
S&F in replacement PVC insulated & PVC Sheathed three core cable of size 1.5 sqmm with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI all as specified and directed.
S&F in replacement of plug top 3 pin 16 amps ISI marked complete all as directed
S & F in replacement of MCB SP 6-32 Amps, 240 V, 50 HZ breaking capacity 10KA, C series all as specified and directed.
M&L for wall fastener of size 100 mm long, 8 mm dia with double washers grouting making good in walls cement mortar (1:4) for fixing water heater, spilit AC outdoor after removing the existing unserviceable nuts /bolts and washers complete all as specified and directed.
S&F in replacement of sealed unit compressor suitable for Refrigarator/Deep Freezer of capacity upto 320 ltrs including sealing of the compressor with welding after assembling complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
S&F in replacement of sealed unit compressor suitable for water cooler of capacity 40/80 Ltrs including sealing of the compressor with welding after assembling complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
S&F in replacement of relay suitable for Refrigarator/ Deep Freezer/water Cooler of any capacity complete all as specified and directed.
S&F in replacement of evaporator coil unit complete suitable for Refrigarator/Deep Freezer of any capacity complete all as specified and directed.
S&F in replacement of tap chromium plated 15 mm dia suitable for water cooler all as specified and directed.
S&F in replacement of filter stainer of suitable for Refrigarator/Deep Freezer/water cooler/AC of any capacity all as specified and directed.
S&F in replacement of overload protector for Refrigerator/Deep Freezer/water coolers/AC all as specified and directed.
S&F in replacement of capacitor 6 MFD for AC/water cooler/Deep Freezer/Refrigerator complete all as specified and directed.
Supply and fix in replacement of ice chamber cabinet of Refrigerator of capacity upto 320 ltrs complete all as specified and directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-134a as required for Refrigarator/Water Cooler/Deep Freezer and testing the cooling effect satisfactorily on full load. The filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
S&F in replacement of thermatically sealed compressor including sealing of the compressor with welding after assembling for 1.5/2.0 Ton Capacity Spilit type AC/ Window type AC complete all as specified and directed.
S&F in replacement of running capacitor 36-45 MFD for window type/Split type AC 1.5/2.0 Ton capacity complete all as specified and directed.
S&F in replacement of starting capacitor 80-120 MFD for window type/split type air conditioner 1.5/2.0 Ton capacity complete all as specified and directed.
S&F in replacement of box type relay suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
S&F in replacement of copper condencer coil unit complete for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
S&F in replacement of capilary tube suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed..
S&F in replacement of fan blade with blower motor of window/split type AC 1.5/2.0 Ton, Refrigerator, deep freezer, water cooler capacity complete all as specified and directed.
S&F in replacement of control circuit (PCB) with remote device suitable for 1.5/2.0 Ton Split type AC complete all as specified and directed.
S&F in replacement of copper tube of size 1/2'' dia for connection of indoor and outdoor unit of split AC/window AC all per directed by the Engineer-in-Charge.
S&F in replacement of copper tube of size 1/4'' dia for connection of indoor and outdoor unit of split AC all per directed by the Engineer-in-Charge.
S&F in replacement of insulation cover of size 5/8" for insulating copper tube of split type AC all per directed by the Engineer-in-Charge.
S&F in replacement of of flair nut for tighting the inlet valve of gas of desire size for connection of indoor and outdoor of split AC all per directed by the Engineer-in-Charge.
S&F in replacement PVC insulated & PVC Sheathed three core cable of size 2.5 sqmm with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI all as specified and directed.
M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-22/R-32 as required for Split AC/Window AC and testing the cooling effect satisfactorily on full load and the filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as directed.
M&L for Shifting Split type AC 1.5/2.0 TR capacity including disconnection of out door & indoor unit, Re installed the same to new location after necessary servicing including testing and commisioning complete all as directed.
S&F in replacement of ceiling fans 1200 mm sweep BEE 5 star rating complete all as specified and as directed. Make: Havells/Usha/Orient/crampton
S&F in replacement of AC support bracket of size 500x500 mm ('L' Shape) 2mm thickness suitable for carrying maximum load 200-250 Kg including necessary fixing arrangements for installation of outdoor unit of split type AC complete all as specified and directed.
S&F in replacement of Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 32 Amps, 240 volts capacity and tested on completion complete all as specified and directed.
Supply and fix in replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA all as specified and directed.
Supply and fix in replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA all as specified and directed.
Supply only refrigerant R-22 gas in air conditioner of any type make capacity complete all as speciifed and directed.
S&F in replacement of float valve assembly complete for water cooler 40/150 ltrs capacity water storage type all as specified and directed.
S&F in replacemet of water purifier stainer for pre filter of single candle complete all as directed
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying XLPE cable/CI/GI pipes and getting out in soft/loose soil complete all specified/directed
Removing excavation soil at a distance not exc 50 m and deposited where directed complete all as directed.
Returning,filling in including spreading, leveling, watering and well rumming in layers not exc 25 cm complete all as directed.
M&L for sand cushioning with clean dry sand for protection of under ground cable complete all as specified and as directed. Note :- Punned thickness of sand layer shall be measured and paid to contractor.
M&L for Brick Sub Class 'B' locally available best quality laid in trenches with width equal to length of the bricks, above sand cushioning for cable protection complete all as specified and as directed.
S&F in replacement steel water tubing 40 mm dia of bore light grade galvanised with all fittings laid in trenches / fixing with surface of wall after drawn through electric cable by means of nuts bolt and washers all as directed .
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 6 sqmm 2 core and testing complete all as specified and directed.
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 10 sqmm 2 core and testing complete all as specified and directed.
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 16 sqmm 4 core and testing complete all as specified and directed.
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 25 sqmm 4 core and testing complete all as specified and directed.
Supply and fix in replacement of aluminium lug of size 6/10 Sqmm for connecting Aluminium XLPE cable all as specified and directed.
Supply and fix in replacement of aluminium lug of size 16/25 Sqmm for connecting Aluminium XLPE cable all as specified and directed.
S&F in replacement of Ultra modern designed architectural LED luminaire 42 Watt, Fixture size in mm (LxWxH) 595x595x65 for 2x2 Ordering : Module + Driver (driver to be ordered separately).which provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid ceiling high grade unbreakable polycorbonate material all as specified and directed. Make Havells Model No. VENUSNEOHE2X2PLR18-42WLED830MOD
Supply and fix in replacement of TPN DB's 6 Way double door when MCCB is to be used for 415 Volts multiple outgoing distribution board sheet steel, powder coated fitted with bus bar Neutral link, earth bar and din rail complete all as directed.
Supply and fix in replacement of TPN DB's 4 Way double door when MCCB is to be used for 415 Volts multiple outgoing distribution board sheet steel, powder coated fitted with bus bar Neutral link, earth bar and din rail complete all as directed.
Supply and fix in replacement of SPN double door MCB distribution board sheet steel, powder coated 8 way fitted with bus bar Neutral link, earth bar and din rail complete all as directed.
Supply and fix in replacement of SPN double door MCB distribution board sheet steel, powder coated 4 way fitted with bus bar Neutral link, earth bar and din rail complete all as directed.
Supply and fix in replacement of MCCB 250 Amps, 4pole, 415volt, 36 KA breaking capacity with all the necessary electrical connections, all as specified and as directed.
Supply and fix in replacement of MCCB 200 Amps, 4pole, 415volt, 36 KA breaking capacity with all the necessary electrical connections, all as specified and as directed.
S&F in replacement of MCCB 4 pole, 125 Amps, 415 volt Icu=100% lcs breaking capacity 36KA including spreader terminals complete all as specified and directed.
S&F in replacement of MCCB 4 pole, 100 Amps, 415 volt Icu=100% lcs breaking capacity 30KA including spreader terminals complete all as specified and directed.
S&F in replacement of MCCB 4 pole, 63 Amps, 415 volt Icu=100% lcs breaking capacity 30KA including spreader terminals complete all as specified and directed.
S & F in replacement of MCB TPN 415 Volts, 63 Amps, 50 Hz, breaking capacity 10KA, C series all as specified and directed
S & F in replcement of MCB SPN 240 Volts, 50-63 Amps, 50 Hz, breaking capacity 10KA, C series all as specified and directed
S & F in replcement of MCB SPN 240 Volts, 6-32 Amps, 50 Hz, breaking capacity 10KA, C series all as specified and directed
S&F in replacement of New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LED light 35 Watt made up of high grade unbreakable polycorbonate material all as specified and directed. Make Havells,Cat No.RUBYPT35WLED830PSYMTOPC
S&F in replacement of Crown shaped gate/garden light in soothing opal finish made up of unbreakable Polycarbonate material, suitable upto 15 W retrofit LED Lamp (B-22 base). all as specified and directed.
Supply and fixing LED not less than 8W, 5700 K, 0.6 M long LED bollard for pathways and gardens are made with aluminium extrusion for sturdiness and better finish, UV stabilized injuction moulded oval polycarbonate diffuser for spot-free lighting and IP 65 degree of protection with fixing accessories complete as per manufacturer's instructions. Model No. CONE NXG LED BOLLARD 8W 0.6M 5700K of make Havells
Supply and fixing LED street lights not less than 25W with a single piece of pressure die cast aluminium housing and secondary optics and individual LEDs for a better light distribution and control with IP66 degree of protection and integrated driver with 10KV surge protection complete as per manufacturer's instructions.
Supply and fix in replacement of loop in loop out junction box with SP 6-32 amp, IP 65 / IP 66 protection halogen free and weather proof of size (205x255x122) mm, fixed to Pole with suitable clamp including nuts and bolts and washers incl provision of connector fixed to pole all as directed. Make:- Hensel model No. DK 2525 G
M & L for earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level , connected to galvanised earth lead iron wire 4mm dia by means of GI bolts nuts and washers of galvanised iron or steel etc all as shown in electrical plate No.3 including earth work PCC pit and RCC pit cover, funnel with watering pipe ,wire mesh ,alternate layer of salt and charcoal, GI protection pipe light grade and testing on completion all as specified and directed by Engr-in-charge. Note.1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose.
D G Corporation
sanjay upadhya
M/S M N ENTERPRISE
M/S Deep-Jeet
M/S MOHANPASARI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .