| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.3 L+₹1.1 L (20.7%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹6.5 L+₹1.3 L (24.3%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹5.3 L
EMD Value
₹13,177
Closing Date
26 May 2023, 6:00 pmClosed
Executive Engineer(Electrical)
University of Calicut
Rerouting and replacement of damaged UG Cables ( VC feeder and Swimming pool) in connection with proposed 4 line Road NH to AD Block and back feeding arrangement from Ladies Hostel feeder
2023_UoC_576976_1
D3/E-Tender No.06/2023-24
Open Tender
Electrical Works
Item Rate
60 days
University of Calicut
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,251
₹13,177
4 Oct 2023
18 May 2023
30 May 2023
18 May 2023
26 May 2023
18 May 2023
Amount
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2 X 300 sq. Mm. (9.4.27)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2 X 240 sq. Mm. (9.4.26)
Supply & laying of DWC pipe in Hard soil 0.75m below ground level including excavation 77/63 mm or nearest size. (od109387/2022_2023)
Re opining cable trenches size 80x35cm size ordinary soil and removing the existing cable and wire cut bricks and refilling the trench with excavated soil leveling the original surface. (od109714/2022_2023)
Re opining cable trenches size 70x35cm size ordinary soil and removing the existing cable and wire cut bricks and refilling the trench with excavated soil leveling the original surface. (od109719/2022_2023)
Labour Charges for removing addition AUG cable 240sqmm to 400sqmm from existing re-opened trench (depth of .7 meter to 1meter). (od109908/2022_2023)
Labour charge for laying AUG cable 240 sqmm to 400 sqmm required length including cutting conveying from Electrical store to work site up to 500 meter by head load without any damage. (od110084/ 2022_2023)
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 120 sq mm. (90.12.1.32)
Fabricating ,supplying and installing 3 nos 200A Kit kat fuse.and neutral link using 450mm x 300mm metal board (using 16swg CRCA sheet and 2 coats enamelled paint).on LT post using suitable size clamp,nut and bolts etc complete.(Including jumper cable connection OH Line to fuse unit). (od110167/2022_2023)
supplying one number of 300 sqmm 3.5 core PVC /XLPE insulated cable with aluminium conductor for working Voltages up to and including 1100 volts. conforming IS 1584/part I/1988 for PVC IS 7098 part I for XPLE, (od110204/ 2022_2023)
Laying of one no PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade following size at existing trench through DWC/HDPE pipe,.above 185 sq mm up to 400 sqmm. (od110208/2022_2023)
120 sqmm 3.5 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE. (od110211 /2022_2023)
Supply & laying of DWC pipe in Hard soil 0.75m below ground level including excavation 125/109 mm or nearest size. (od110224/2022_2023)
Supply & laying of DWC pipe 0.75m below ground level 125/109 mm or nearest size in the existing trench. (od110238/2022_2023)
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X50 cm at the top with a thickness of 10cm including inscription duly engraved as required. (7.9)
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench125/109 mm or nearest size. (90.12.9.8)
Excavation of trench size 35 x 75 cm for laying above 185 sq mm and up to 400 sq mm AUG Cable, refilling the same etc. As required but excluding sand cushioning and protective covering (in hard soil). (od114571/2022_2023)
ASIF ELECTRICAL WORKS
MOHAMMED MUSTHAFA K.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_852049.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .