Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.6 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹78.7 L+₹17.1 L (27.7%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹62 L
EMD Value
₹62,000
Closing Date
20 Jun 2020, 12:00 pmClosed
SE, EDC, Rampur
Office of the SE, EDC, Civil Lines Rampur
10/2020-21(EDCR) Annual maintenance work of underground cable of 11 KV HT and LT Lines of 288 No. DTRs in Rampur Town under the jurisdiction of EDD-I, Rampur from 01-07-2020 to 30-06-2021 (12 Months).
2020_PVVNL_481598_1
10/2020-21(EDCR)
Open Tender
Electrical Works
Lump-sum
365 days
Office of the SE, EDC
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
SE, EDC, Rampur
₹62,000
7 Aug 2020
9 Jun 2020
20 Jun 2020
9 Jun 2020
20 Jun 2020
9 Jun 2020
Amount
Laying of 11 KV XLPE Cable
By Digging of Trench and Laying of 11KV XLPE Cable size 3x185 sq mm and leveling the digged trench upto ground level where the old underground 11 KV HT cable fault is not traceable (Cable shall be provided by the department).
By Digging of Trench and Laying of 11KV XLPE Cable size 3x120 sq mm and leveling the digged trench upto ground level where the old underground 11 KV HT cable fault is not traceable (Cable shall be provided by the department).
Making a Joint by using 11KV Out door Cable Jointing Kit
Making a Joint in 11 KV XLPE cable of size 3x185 sq mm by using 11 KV out door cable jointing Kit of size 3x185 sq mm (Jointing Kit shall be provide by the department).
Making a Joint in 11 KV XLPE cable of size 3x120 sq mm by using 11 KV out door cable jointing Kit of size 3x120 sq mm (Jointing Kit shall be provide by the department).
By Digging the earth upto the 11 KV existing cable level and searching the fault with the help of fault locating machine and Making a Joint by using 11 KV straight Through jointing Kit of Size 3x185 sq mm (Fault locating machine and S. T. Jointing Kit shall be made available by the department )
By Digging the earth upto the 11 KV existing cable level by searching the fault with the help of fault locating machine and making a Joint by using 11 KV straight Through jointing Kit of Size 3x120 sq mm (Fault locating machine and S. T. Jointing Kit shall be made available by the department )
LT Underground Cable Repairing Work
By digging the trench against existing damaged LT Cable and Laying of LT Cable of Size 3.5Cx400 sq mm and laveling the digged trench upto ground level after laying the cable (cable shall be provided by the Contractor)
By serching the underground LT cable fault with the help of fault locating machine and digging the earth upto damaged LT cable portion and making the joint in the cable of size 3.5Cx 400 sq mm by cable jointing kit and after attending the fault laveling the digged trench (fault locating machine shall be made available by the department and LT jointing kit to be provided by the Contractor)
By digging the trench against existing damaged LT Cable and Laying of LT Cable of Size 3.5Cx240 sq mm and leveling the digged trench upto ground level after laying the cable (cable shall be provided by the Contractor)
By serching the underground LT cable fault with the help of fault locating machine and digging the earth upto damaged LT cable portion and making the joint in the cable of size 3.5Cx 240 sq mm by cable jointing kit and after attending the fault leveling the digged trench (fault locating machine shall be made available by the department and LT jointing kit to be provided by the Contractor)
By digging the trench against existing damaged LT Cable and Laying of LT Cable of Size 3.5Cx120 sq mm and leveling the digged trench upto ground level after laying the cable (cable shall be provided by the Contractor)
By serching the underground LT cable fault with the help of fault locating machine and digging the earth upto damaged LT cable portion and making the joint in the cable of size 3.5Cx 120 sq mm by cable jointing kit and after attending the fault laveling the digged trench (fault locating machine shall be made available by the department and LT jointing kit to be provided by the Contractor)
By digging the trench against existing damaged LT Cable and Laying of LT Cable of Size 3.5Cx70 sq mm and leveling the digged trench upto ground level after laying the cable (cable shall be provided by the Contractor)
By serching the underground LT cable fault with the help of fault locating machine and digging the earth upto damaged LT cable portion and making the joint in the cable of size 3.5Cx 70 sq mm by cable jointing kit and after attending the fault laveling the digged trench (fault locating machine shall be made available by the department and LT jointing kit to be provided by the Contractor)
By digging the trench against existing damaged LT service Cable and Laying of Armoured LT service Cable of Size 4Cx16 sq mm and laveling the digged trench upto ground level after laying the cable (cable shall be provided by the Contractor)
Digging of trench against damaged underground 4Cx10 Sq mm LT service cable and laying of Armoured LT Service Cable of size 4Cx10 Sq mm and leveling the digged trench upto ground level after laying the cable (Armoured cable shall be provided by the Department)
Digging of trench against damaged underground single phase 2Cx6 Sq mm LT service cable and laying of Armoured LT Service Cable of size 2Cx6 Sq mm and leveling the digged trench upto ground level after laying the cable (Armoured cable shall be provided by the Department)
Laying of LT XLPE unarmoured cable
Laying of LT XLPE unarmoured cable of size 1Cx1000 sq mm (to be provided by the Department)
Laying of LT XLPE unarmoured cable of size 1Cx400 sq mm (to be provided by the Department)
Laying of LT XLPE unarmoured cable of size 1Cx120 sq mm (to be provided by the Department)
Replacement of C type DB Boxes
Replacement of damaged LT Lockable Distribution Boxes C1 type by new LT Lockable Distribution Boxes C1 type with proper fixing on existing stand and dressing and termination of LT Cable and Consumer Cable (having size 450x400x200 mm with busbar 100 Amp and AL busbar 250 Sq mm size) (C1 Type box to be provided by the contractor)
Replacement of damaged LT Lockable Distribution Boxes C2 type by new LT Lockable Distribution Boxes C2 type with proper fixing on existing stand and dressing and termination of LT Cable and Consumer Cable (having size 450x400x200 mmm with busbar 70Amp and AL busbar 150 Sq mm size) (C2 Type box to be provided by the contractor)
Repairing /Replacement of A, B Type boxes Pannel doors
Repairing/Replacement of A1 and A2 Type LT DB Pannel Doors(A1 box having door spacification 700x2000 Sq mm and 900x2000 sq mm, A2 Box having door spacification 700x1650 Sq mm and 900x 1650 Sq mm with handle and locking arrangement )
Repairing/Replacement of A3 and A4 Type LT DB Pannel Doors(A3 box having door spacification 850x1650 Sq mm and 700x1650 sq mm, A4 Box having door spacification 800x1600 Sq mm and 500x 1600 Sq mm with handle and locking arrangement )
Repairing/Replacement of A5 and A6 Type LT DB Pannel Doors(A5 box having door spacification 900x800 Sq mm, A6 Box having door spacification 450x550 Sq mm with handle and locking arrangement )
Repairing/Replacement of B1 and B2 Type LT DB Pannel Doors(B1 box having door spacification 750x1500 Sq mm and 400x1500 sq mm, B2 Box having door spacification 900x1000 Sq mm with handle and locking arrangement )
Repairing/Replacement of D1 and D2 Type LT DB Pannel Doors (D1 box having door spacification 600x825 Sq mm and , D2 Box having door spacification 500x725 Sq mm with handle and locking arrangement )
Repairing of C1 and C2 type boxes stand
Replacement of LT MCCB
Replacement of Damaged Incoming MCCB of A2 Pannel having rating 1250 Amp 4 Pole manually fixed ACB with inbuilt MPR Release having overload, earth fault protection and with on/off indicating lights prefferably Havells Make (MCCB is to be provided by the Contractor )
Replacement of Damaged outgoing MCCB of A1 and A2 Pannels and incomming of A4 Pannels having rating 400 Amp 4 Pole MCCB with spreader, extended handle and on/trip indicating lights suitable for existing system prefferably Havells Make(MCCB is to be provided by the Contractor)
Relacement of outgoing MCCB of A1, A2 and A3 and incomming MCCB of A5 pannels having rating 250 Amp, 4Poles MCCB (With provision to connect LT Cable 3.5Cx400 sq mm) With spreader, extended handle and on/trip indicating lightsfor existing system prefferably Havells Make (MCCB is to be provided by the Contractor )
Relacement of outgoing MCCB of A3, A4 and A5pannel and for B1 and B2 Pannel having rating 100 Amp 4 Pole MCCB with spreader and extended handle for existing system prefferably Havells Make(MCCB is to be provided by the Contractor )
Replacement of Bus bars
Replacement and fixing of AL Busbar having size 60(Bredth)x10(width) sq mm in A1, A2 and A3 Type pannels against damaged busbars and making the connection existing cable ( busbars to be provided by contractor)
Replacement and fixing of AL Busbar having size 40(Bredth)x10(width) sq mm in A4, A5, A6 and B1, B2 Type pannels against damaged busbars and making the connection existing cable (busbars to be provided by contractor)
Replacement of AL cable Lugs
Replacement of damaged Aluminium Lugs from the cable with the help of crimping tool of sizes 1000, 630, 400 sq mm (Lugs to be provided by contractor)
Replacement of damaged Aluminium Lugs from the cable with the help of crimping tool of size 240 sq mm (Lugs to be provided by contractor)
Replacement of damaged Aluminium Lugs from the cable with the help of crimping tool of sizes 120, 70, 50, 35,25, 16, 10 and 6 sq mm (Lugs to be provided by contractor)
CC Road and Interlocking Road Restoration works and bring it to original position
Cartage Charges of department material from PVVNL store, Rampur to site.
A.S.R CONTRACTOR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .