Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC 1 IPCL NEAR SHIV TRANSPORT RANOLI VADODARA GUJARAT 391350 | VADODARA | GUJARAT | 391350 | ₹2.6 Cr | L1 | Accepted-AOC Contract is awarded to L1 bidder R K ENGINEERING and CONTRACTORS on Overall Lowest techno commercially acceptable bidder |
| 2 | L2₹3.6 Cr+₹96.3 L (36.7%)Rejected-Finance | ₹3.6 Cr+₹96.3 L (36.7%) | L2 | Rejected-Finance L2 BIDDER |
Tender Value
Refer Docs
EMD Value
₹5.8 L
Closing Date
21 May 2025, 2:00 pmClosed
RAJEEV KUMAR
Hazira Compressor Station, Ichhapore Magdalla Road, PO- ONGCL, Hazira, Dist Surat 394 518
COMPOSITE WORK IN RESPECT OF MECHANICAL, ELECTRICAL AND GAILTEL WORK TO RELOCATE SV-06 (KHAJOD) OF DUPL
2025_GAIL_234096_1
HZR/CNP/128482/FL-07C/25-26
Open Tender
Civil Works
Item Rate
182 days
GAIL Hazira Compressor Station
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹5.8 L
GAIL Hazira Compressor Station
26 Jun 2025
1 May 2025
22 May 2025
1 May 2025
21 May 2025
13 May 2025
12 May 2025
Amount
PLANT PIPING (ABOVE GROUND & HOOK-UP WITH UNDERGROUND PIPELINE) Complete Carbon Steel Piping Work with painting including all fittings, flanges and supply of all required gaskets, studs bolts & nuts, etc., as described below Transportation of all piping items from Contractor's storage point to work site complete work of fabrication, erection, painting, testing of pipes, flanges and fittings and making ready for further commissioning / start-up of carbon steel piping of all sizes and ratings including supply of all consumables, equipment, manpower and other resources and execution of, but not limited to, the following works in accordance with relevant specifications indicated in particular job specification & scope of work indicated in SCC, drawings, specification and instructions of EIC and as per all provisions of the Contract Document. Fabrication including cutting, edge preparation, inclusive of grinding the edges of pipes, fittings, flanges, etc. to match with the matching edges of uneven / different thickness wherever required, welding, attachment of all pipe fittings like elbows, tees, reducers. Supply of nipples, couplings, caps, plugs, gasket, stud bolts, nuts, U-clamps, etc. as required for completion of job.All fittings installation shall be paid linear meter basis under this item only. Handling and installation of all types & size of valves including assembly of valve accessories/ Actuator, (if any) by bolting, threading or welding, supply and insertion of gaskets, nuts & bolts, nipples, tubing etc. at all elevations of pipe sleepers, supports or overhead on racks, equipments nozzle, skid & painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of EIC including servicing / cleaning of valve wherever required.Installation of weldolets, sockolets, flanges, vent and drain point connection, Insulating joints, pipes, spool-pieces etc., as required. Erection including prior cleaning, lifting, placing on pipe sleepers and supports, overhead on racks, skids and at all elevations including installation, design & fabrication of all type of supports / jump-over and carrying out connected activities for all types of valves including supply & fixing of gaskets, studs / bolts, nuts wherever required for all sizes, leveling, aligning, joining of flanges, blind flanges, connecting with equipment, nozzles, strainers, tie-in with existing piping / facilities, etc. tapping for inline instruments like pressure gauges, thermowells, sample connection, etc. Preparation of bill of material (BOM) Preparation of Construction, Fabrication and As-built drawings Carrying out all Non-destructive testing as required including Radiography. Surface preparation before application of primer by means of sand blasting including supply of approved quality of sand, manpower, machineries, tools & tackles to achieve required roughness as per specification and as per instruction of EIC. Painting of entire system (including aboveground all pipes fittings, flanges & accessories) suitable for Normal corrosive area environment including supply of approved paints & primers, application of primer & paints, identification lettering / numbering, color-coding, etc. as specified including rub-down & touch-up of shop primer or scrapping of shop primer wherever required by Company and providing scaffolding for all heights, etc. Cleaning and flushing by water / compressed air, testing of the systems including hydrostatic, pneumatic and any other types of testing as specified, draining, drying by compressed air / other methods approved by Company. Precommissioning & making operational of all piping system and equipments. Contractor shall provide all necessary assistance in terms of supply of manpower, equipment, tools and tackles, consumables, required amount of nitrogen for purging of entire terminal piping system including equipments etc. to the company during commissioning activities. Completion of all such work in all respects as per scope of work and as per drawings,specifications and instructions of the COMPANY and keeping the system ready in all respects for further commissioning and start-up. @Note: Carrying out all Non-destructive testing as required for 2" & below lines, are inclusive in this SOR Item.
2" and below
Above 2" to Below 12" Pipe (various thickness range)
12" and Above (various thickness range) Note: For Hook-up works with 30" mainline U/G pipeline, including cutting and welding at tap-off point including making provision for hooking up and carrying out shutdown activities at terminals, if necessary, shall be paid as per SOR number B008000
Supply and Application of Coating Supply and application of pipeline coating(wherever required)/repair including removaling the old/damaged coating/rust, greese, moisutre and all foreign material, surface preparation, supply of coating material, Epoxy primer or any other primer/base required to apply before coating as per relevant coating material, Patch repair kit, holiday testing after coating application/repair etc. as per relevant standard and as per directione of Eingineer In-Charge.
Pipeline coating-Raychem Heat shrink sleevs
INSTALLATION OF VALVES INSTALLATION OF ABOVE GROUND FLANGED VALVES (BALL / PLUG / GLOBE) AS PER DETAILS GIVEN BELOW:
Size - 6.0 Inch, Rating - 600#
Size - 2.0 Inch, Rating - 600#
Size - 3/4 Inch, Rating - 800#
INSTALLATION OF ABOVE GROUND BUTT WELDED
Size - 18.0 Inch, Rating - 600#
Size - 2.0 Inch, Rating - 600#
Size - 3/4 Inch, Rating - 800#
INSTALLATION OF UNDER GROUND BUTT WELDED (EXTENDED STEM) ACTUATED SECTIONALIZATION VALVE (SV) AS PER DETAILS GIVEN BELOW:
Size - 30.0 Inch, Rating - 600#
INSTALLATION OF UNDER GROUND BUTT WELDED / FLANGED (EXTENDED STEM) VALVES (BALL / PLUG / GLOBE) AS PER DETAILS GIVEN BELOW
Size - 10.0 Inch, Rating - 600#
SUPPLY OF ASSORTED PIPE,VALVES ,FITTINGS AND FLANGES Complete work of supply of pipes, valves, fittings and flanges including all taxes, duties, transportation and inspection charges but not limited to, the following items in accordance with relevant specifications indicated in scope of work , drawings, specification and instructions of EIC and as per all provisions of the Contract Document. Handling including lifting, transportation from Contractor Stores to Contractor's workshop / work-site for fabrication of all piping items supplied by Contractor.
CARBON STEEL (CS) PIPES (As per attached QAP in Tender)
CS Pipes 2" NB Sch XS API 5L Gr.B, Seamless, BE / A 106 Gr.B.
CS Pipes 3/4 " NB Sch 160 , A 106 Gr.B. M
3 LPE Coated Pipes 2" NB Sch XS API 5L M Gr.B, Seamless, BE / A 106 Gr.B
VALVES
Supply of Butt/Socket Welded- Female
Size - 0.75 Inch, 800#, SW Ends, Design
Size - 2 Inch, 600#, BW Ends, Design Sta
Supply of Flanged Ends Ball Valves as per PMS and Data Sheet (As per attached QAP in Tender)
Size - 0.75 Inch, 600#, RF Flanged Ends
Supply of Flanged Ends Globe Valves as per PMS, Data Sheet and QAP in Tender
Size - 2 Inch, 600#, Flange Ends, Design Standard - BS 5353 / API 599
SUPPLY OF FLANGES
Supply of Weld Neck Raised Face Flanges (WNRF) as per details below: (As per attached QAP in Tender)
Size - 2 Inch, 600# , Thk/Sch - XS , Material - ASTM A105, Face/Finish - RF/125AARH , Dimn. Std. - ASME B16.5
Size - 3/4 Inch, 600# , Thk/Sch - 160 , Material - ASTM A105, Face/Finish - RF/125AARH , Dimn. Std. - ASME B16.5
Supply of Raised Face Blind Flanges (BLRF) as per details below: (As per attached QAP in Tender)
Size - 2 Inch, 600# , Thk/Sch - XS ,Material - ASTM A105, Face/Finish - RF/125AARH , Dimn. Std. - ASME B16.5
Size - 3/4 Inch, 600# , Thk/Sch - 160 , Material - ASTM A105, Face/Finish - RF/125AARH , Dimn. Std. - ASME B16.5
SUPPLY OF FITTINGS
Supply of R=1.5D 90o BW Elbow as per details given below: (As per attached QAP in Tender)
Size - 2.0 Inch, Thk/Sch - XS, Material - ASTM A 105, Dimn. Std. - ASME B 16.11
Size - 3/4 Inch, Thk/Sch - 160, Material - ASTM A 105, Dimn. Std. - ASME B 16.11
Supply of Figure-8 Spectacle Blind as per details given below: (As per attached QAP in Tender)
Size - 2.0 Inch, Material - ASTM A 105, Dimn. Std. - ASME B 16.48
Size - 3/4 Inch, Material - ASTM A 105, Dimn. Std. - ASME B 16.48
Supply of Sockolet conforming to MSS-SP- 97, Material - ASTM A105 and as per details given below:: (As per attached QAP in Tender)
Supply of Weldolet conforming to MSS-SP- 97, Material - ASTM A105 (CHARPY) -As per attached QAP in Tender and as per details given below:
18" x 2", Thk/Sch - XS
10" x 2", Thk/Sch - XS
Supply of Reducer (CONCENTRIC) as per attached QAP in Tender and as per details given below:
2" X 3/4", Sch-XS x Sch-XXS, ASTM A 234 GR. WPB, BWxSW, ASME B16.25 & ASME B16.11
Supply of Pipe-Nipple
Pipe-Nipple, 3/4 inch, ASTM-106
RADIOGRAPHY Performance of radiographic inspection by gamma radiation as per scope of work and as per specifications in piping of all types and thickness including providing / hiring of all necessary equipments, supply of all consumables, and whatever else even though not expressly mentioned but required to perform the work as per specifications and instructions of EIC (full circle re-radiography of the repaired joint and additional radiography necessitated due to poor performance of contractor's welder shall be carried out by the Contractor at his own cost and shall not be paid extra by Company). Radiographs shall be submitted to the EIC for acceptance whose decision shall be final and binding.
Radiography 2" NB
Radiography 10" NB
Radiography 18" NB
Radiography 30" NB
DISMENTALING, CUTTING, SHIFTING, HANDLING, LIFTING, TRANSPORTATION (INSTALLATION) OF EXISTING PIPELINE FACILITIES AT SV-06 STATION
DISMENTALING, CUTTING, SHIFTING, including lifting, transportation from existing SV-06 sttaion to new proposed location of SV-06 station for fabrication or/and to worksite for field fabrication, assembly of parts / sub-assemblies erection for all vessels, equipments supplied by company aboveground / underground at all elevation / depth, . Contractor's scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, finish coat of painting including rub-down and touch-up of shop primer / paint scrapping of shop primer / paint and further their painting after application of primer as per specification, wherever required by Company.
RECEIVING & TAKING OVER, HANDLING, TRANSPORTATION OF PIPES , FLANGES , FITTINGS , VALVES ETC (TERMINAL / MAINLINE MATERIAL / SURPLUS MATERIAL) - ANYWHERE IN INDIA The Contractor shall receive and take over, Handling including lifting, Owner-supplied bare / 3 LPE Coated line pipe / Ball Valves ,Flanges , Fittings and any other material from GAIL's designated store, inspection of material at dispatch point as well as destination point and its transportation to work-site (including transit Insurance) / return of project surplus / sparable material from Project site / Contractor's store to GAIL's tore / warehouse including loading on trucks / trailers, transportation, unloading & stacking on wooden sleepers at Contractor's own stock-yard near work-site(s) / GAIL store (as applicable), including arrangement of truck / trailers / cranes / other material / machinery / manpower / consumables.
Transportation by Trailer Fix up to 0-50 KM (Weight up to 18 Ton) per trip
Transportation by Truck Fix up to 0-50 KM (Weight up to 10 Ton) per trip
Transportation by Trailer CapacIty 18 Ton (40' L X 8.6' W X 7' H) Beyond 50 KM in addition to SOR Item No. 2.14.1.
Transportation by Truck (Weight up to 10 Ton) Beyond 50 KM in addition to SOR Item No. 2.14.2. Note: (1) Transportation up to 50KM shall be paid by SOR no. B006010/B006020. Beyond 50KM transportation shall be paid by SOR no. B006030/B006040. (2) The quantities given in above item no. are tentative only and shall not be considered to be binding. The quantities may be increased, decreased or deleted as per the actual site requirement and instructions / recommendations of Owner. The unit rate shall be operated to work out the final payment to the Contractor; (3) Above price shall be exclusive GST but inclusive of all type of toll taxes & duties, transit insurance during transportation & other insurance, etc. including all financial & commercial implication as per the tender document. (4) The weightage of material may be varies as part load or full load as per the project requirement, Bidder to be quoted the price accordingly.
FIRE EXTINGUISHERS (Portable) Supply, installation and commissioning of the following fire extinguishers:
CO2 (10 Kg) considered 1 no. for each locations
10 kg capacity DCP fire extinguisher (portable) considered 1 no. for each locations
6 kg capacity DCP fire extinguisher (portable) considered 1 no. for each locations
4 Nos. Sand Buckets with stand & canopy considered 1 set for each location
PADDING FOR PIPE SUPPORTS (4 Inch and Above)
Preparation, Fabrication and erection of padding for pipe supports (for all sizes/ thickness) by owner supply material(pipes). Welding shall be done by approved welder as per Approved WPS of Station piping with Root 6010 & Hot pass 7018 .
NITROGEN SUPPLY
Supply of Nitrogen for preservation of Pipeline/ purging of pipeline / hookup & shut down activities .
Mobilization & De-Mobilization Charges
This item includes but not limited to mobilization/De-mobilization of Minimum 01 Supervior, 02 No Qualified welder, 02 Nos Fitter, 02 Nos Grinder, 02 Nos Helper, 02 No Rigger along with machine and all tools and tackles as defined in the Scope of work.
Supply of Bend ( Pipe Shall be As Free Issue Material)
Bends (R = 6D) 30" NB, 19.1 mm (Or Higher) W.T. X-70 Angle - 15° to 45° Note: (1) The quantities given above against individual items are indicative and shall not be considered to be binding. The quantities may be increased, decreased or deleted at site at the time of actual execution. Procurement shall be done as per actual site condition, approved construction drawings and as per instruction of EIC. The unit rate shall be operated to work out the final payment to the Contractor; a (2) Quantities given against individual item may be utilised / used for other consumers in same area. (3) Quantity of Nitrogen for purging may vary subject to confirmation of positive isolation of upstream & downstream SV Station Valves.
SECTION-D [ELECTRICAL WORKS]
Supply, installation, testing and commissioning of Street Lighting Fixture suitable for 250W HPMV or Equivalent LED Lamps on Lighting Poles (4mtr Height) with aluminium paint complete with mounting bracket, flameproof control gear box, internal cable from fitting to junction bo+B211+B208:B215+B208:B217+B208:B218+B208:B219+B208:B220+B208:B222+B208:B22 3+B208:B222+B208:B221+B211+B208:B215+B208:B222+B208:B223+B208:B224+B208:B225 +B208:B226+B208:B225+B208:B228+B211+B208:B215+B208:B230+B208:B233+B208:B236 +B208:B239+B211+B208:B215+B208+B208:B251
Supply, installation, testing and commissioning of Indoor Lighting Fixtures suitable for 18/26/36W LED Lamps ( including Lamps) for including all fixing arrangements and all material ( PVC duct pipe, clamps, etc.) and labour as per specifications, drawings and instruction of EIC. Work to be completed in all respects.
Supply, installation, testing commissioning of Exhaust fans (safe area) for including all fixing arrangements and all material ( PVC duct pipe, clamps, etc.) and labour as per specifications, drawings and instruction of EIC. Work to be completed in all respects.
Supply, installation, testing commissioning of Exhaust fans (Corrosion Proof Type) for including all fixing arrangements and all material ( PVC duct pipe, clamps, etc.) and labour as per specifications, drawings and instruction of EIC. Work to be completed in all respects.
Recess/Surface mounted Indoor Lighting Panel(ILP) Consisting of 40 Amp FP MCB+ELCB as incomer and 12 nos. 10A DP MCBs as out goings.
Recess/Surface mounted Power Panel(PP) Consisting of 63 Amp FP MCB as incomer and 9 nos. 20A DP MCBs as out goings.
Recess/Surface mounted Outdoor Lighting Panel OLP (For External Lighting) Consisting of 40 Amp FP MCB+ELCB as incomer, Contactor, timer, A/M switch, PB, indication Lamp etc Outgoing Through Timer:6 Nos. 16 Amp DP MCB
Supply, installation, testing commissioning of Solar Power Package of rated power of 5.0 KWp Hybrid solar invertor with roof top Solar Panels, Charger Panels with Ni-Cd Battery Bank (48 hours Backup), Battery Rack, Support Structures for including all fixing arrangements, Earthing and earthing materials, Lighting Arrester, AC/DC cables, AC DB/DC DB, Civil Works and all material and labour as per specifications, drawings and instruction of EIC. Work to be completed in all respects. @Note: Bidder shall consider the scope as per details given in SOW (Typical SLD)
Recess/Surface mounted UPS DB Consisting of 63 Amp DP MCB as incomer, MFM with ON/OFF indicator, fuse, 60A DP, Cu Bus Bar and 13 nos. 10A DP MCBs as out goings.
Design, Engineering, supply, erection , termination, earthing and commissioning of Guard room DB complete in all respects.16 Amp DP MCB as incomer, 30A SPN, Cu Bus Bar and 2nos. 6A DP MCBs and 4 nos. 16 A DP MCBs as out goings.
Supply, installation, testing commissioning of Flameproof Flood Lighting Fixtures suitable for 250/400W HPMV or Equivalent LED Lamps for including all fixing arrangements on top of terrace of container and all material ( PVC duct pipe, clamps, etc.) and labour as per specifications, drawings and instruction of EIC. Work to be completed in all respects
Supply, installation, testing commissioning of Modular Switch Board for including all fixing arrangements and all material ( PVC duct pipe, clamps, etc.) and labour as per specifications, drawings and instruction of EIC. Work to be completed in all respects.
Supply, installation, testing commissioning of 5/15A Switch Socket for including all fixing arrangements and all material and labour as per specifications, drawings and instruction of EIC. Work to be completed in all respects.
16 A plug socket MCB for AC
Supply, installation, testing and commissioning of Ceiling Fan 230V AC 1200 mm sweep with regulator work to be completed in all respects
Supply ,Installation and testing of 1.5 Tr. 5 star inverter base Indoor & Outdoor unit of split AC including all labours and materials for Typical SV station refer General specification of Erection, Installation, Testing & commisioning of Electrical Equipments, General Specification for Air conditioningSystem and directions of OWNER / CONSULTANT.
Supply and Installation of Hardware and other accessories including all labours and materials as per General specification of Erection, Installation, Testing & commisioning of Electrical Equipments , Electrical Design Basis , General Specification for Cable and accessories and directions of OWNER / CONSULTANT.
Rubber Mat
CAUTION Board & Shock treatment chart
Rubber hand gloves
Cable route marker
Ladder type Cable tray - Galvanized steel fabricated out of hot rolled sheet steel with rigid welded ladder type 450 mm wide straight run
Supply, installation, testing & commissioning of the complete earthing system, earth electrodes/pit, earth main ring, earthing of metering skid, electrical equipments, instrument panels, field instruments, process equipments & pipes / flanges including all associated civil work with all material & labour as per specification & drawings approved by the company. Each earthing system shall include the following.
65mm dia 3 Mtr. Long GI PIPE Electrode Electrode with 6mm thick chequered plate cover, display board etc
600x600x3mm copper plate Electrode with 6 mm thick chequered plate cover, display board etc
GI Strip (50X6) mm
GI Strip (25X6) mm
1C 25 Sq.mm PVC insulated Cu Conductor
10 SWG GI wire
GI Wire, Copper wire, wire rope all balance earthing material including copper strip (50 mmX 2 mm thick) jumper for flanges etc.as per the specification.
300mm long 50x6 GI earth busbar
25mm dia 1500mm long GI rod for lightning protection
25x6mm GI strip for building roof & down conductor for lightning protection
PVC Conduit including bend,tee clamps,JB and other required assesories
Supply, laying, installation,termination
4C x 95 sqmm AL FRLS XLPE
4C x 35 sqmm AL FRLS XLPE
4C x 16 sqmm CU FRLS XLPE
3C x 6 sqmm CU FRLS XLPE
3C x 16 sqmm CU FRLS XLPE
4C X 6 Sqmm Cu conductor XLPE InsulatedM Armoured Power Cable of 1100V Grade
3C X 2.5 Sqmm Cu conductor XLPE Insulate Armoured Power Cable of 1100V Grade
2.5 sqmm CU Wire
4.0 sqmm CU Wire
6.0 sqmm CU Wire
SECTION-E [INSTRUMENTATION WORKS]
Supply, Calibration and Installation of instrumentation items listed below: (For details, refer instrumentation specifications)
Pressure Gauge of different Range and rating as per site requirement Engineering , Design, Supply, testing, installation, erection and commissioning. Also supply of erection material like SS316 tube, SS316 fittings, manifold, mounting stand and all other required material. Bourdon type with 2-way manifold, direct mount, 150mm dial, wetted part SS316, IP 65 rated, blow out protection and shatter proof heavy duty glass.
Pressure Transmitter of different Range and rating as per site requirement Engineering , Design, Supply, testing, installation, erection and commissioning. Also supply of erection material like SS316 tube, SS fittings, manifold, mounting stand and all other required material. Smart HART, Ex'd', IP-65, 24 VDC 2-wire loop powered.
Temperature Gauge - skin type direct mount as per site requirement Engineering , Design, Supply, testing, installation, erection and commissioning. Also supply of erection material like SS armoured capillary, mounting stand and all other required material. Skin type, direct mount, 150mm dial, wetted part SS316, IP 65 rated and shatter proof heavy duty glass.
Temperature Transmitter of different Range and rating as per site requirement3 Engineering , Design, Supply, Installation, Calibration, Testing & Commissioning of Temperature Transmitters including mounting of Instrument on yoke, supply of yoke, supply and erection of supports for impulse lines wherever required, supply, fabrication & installation of SS manifolds/ SS impulse lines & SS valves & fittings with supports, testing and painting of supports.
RTD Engineering , Design with wake frequency calculation, Supply , Installation, Calibration, Testing & Commissioning of RTD Flanged type thermowell (as per approved Piping GAD & Hookup drawings) inclusive of installation of thermowell on thepiping nozzle and installation of instruments as per General Specification-Instrumentation
Valve Junction Bob - Gas Over Oil Actauted Valve (GOOV) and or HOV of different size and rating as per site requirement Installation of valve junction box and their accessories inclusive of supply of necessary cable glands, terminals and complete with cabling, glanding, termination and earthing followed by testing and commissioning of complete gas over oil actuated valve.
Gas Detection System (GDS) Supply, configuration, testing, installation, erection and commissioning of gas detection system including point gas detectors,control unit and junction boxes. Gas detector control unit shall be installed inside the local control panel. Supply, Laying of cable inside the cable trench, cable tray for hardwired signals and power cables from gas sensors to gas detectors control unit including glanding, termination, ferruling, dressing etc. at both ends. Supply of cable trays, installation and erection of cable trays and, supply of erection materials, cable ferrules, cable lugs, cable tie.
IR type, Flame proof, IP-65, housing material SS316 without display, range 0-100% LEL point hydrocarbon gas detector
Hooter, electronic multi-tone, IP-65 Ex'd' and epoxy coated aluminium housing material
Beacon, electronic stroboscopic type Ex'd' and epoxy coated aluminium housing material.
Manual Call Point (MCP), electronic, 24 VDC power, IP-65, Ex'd' and GRP/aluminium housing material
Junction box
Cables, Cables Trays and Junction boxes Supply, laying, installation, erection of signals cable from pressure transmitters, temperature transmitter to junction boxes, junction boxes to existing local control panel (LCP)/FC. including glanding, termination, ferruling, dressing etc. at both ends. Laying of cable from remote operated valve junction box to existing local control panel (LCP)/FC ncluding glanding, termination, ferruling, dressing etc. at both ends. Supply of cable trays, cables glands, junction boxes, erection materials, cable ferrules, cable lugs, cable tie. Installation and erection of cable trays and junction boxes Preparation of cable trench for burying cable, excavation, restoration of trench and compacting. Supply and laying of bricks and sand, pipes at all the crossings etc.
1P X 1 .5 Sq. mm Over all Screened
1 P x 2.5 Sq. mm Over all Screened
2 P x 1.5 Sq. mm Over all Screened
1Q X 1 .5 Sq. mm Over all Screened
12P X 0 .5 Sq. mm Individual Screen & Over all Screened
6 P x 1.5 Sq. mm Over all Screened NIS cable
12 P x 1.5 Sq. mm Over all Screened NIS cable
1 T x 1.5 Sq. mm Over all Screened NIS cable
8 T x 1.5 Sq. mm Over all Screened
4 P x 2.5 Sq. mm (For power supply)
3C X 2 .5 Sq. mm Power cable
2C X 1 .5 Sq. mm Power cable
Serial communication cable, Modbus RS - 485, PVC Sheathed, 4 pair
Junction Box 'Flameproof Junction box as per specification with Plug and suitable for cable entries of single pair and multi pair cable as per the Instrument cable schedule
Cable Trays (60 mm wide x 30 mm height)
Cable Trays (100 mm wide x 30 mm height)
Cable Trays (300 mm wide x 30 mm height)
Multi cable Transit (MCT) block with stay plate and module as per the approved datasheet
Canopy
FIRE DETECTION CUM ALARM SYSTEM AND CLEAN AGENT FLOODING SYSTEM
Design , Engineering , Volume calcualtion, Power consumption Calculation, Supply, manufacturing, inspection, delivery, Installation, Testing and comissioning of Fire Detection cum Alarm System and Clean agent Flooding System for control room building as per technical specification, Scope of Work of tender document and completion of work in all respects. Control Room building consists of Instrumentation, Scada / Telecom Room of size 5m X 4m X 4m (h), Electrical Room of Size 3m X 5m X 4m (h) and Battery Room of Size 5m X 3m X 4m (h). Contractor's scope of supply and installation of all the required material, manpower, machinery to complete the system in all respects or as per direction of EIC.
SECTION-F [TELECOM WORKS]
System design, Inspection & factory test FAT, SAT, training, installation, commissioning, Trial run, pre-factory tests, packing, forwarding and supply of all goods including commissioning spares & documentation, pre-commissioning activity for telecom
Supply of 24 Fibre Composite armoured Optical Fibre Cable drum (6 fibre G-655 & 18 fibre G-652) of 4 km +/-5% Cable drum length.
Supply of jointing closure 24 Fiber 2 way including all accessories (3M, Siemens, Raychem make only)
Supply of 40mm OD permanently lubricated HDPE telecom duct as per technical specifications including manufacturing, factory testing, inspection, packaging, forwarding, transportation, insurance, receipt and storage at site.
Telecommunication Site Work
Laying of HDPE Telecom Duct Laying of 40mm HDPE Ducts in same pipeline trench direct buried or cased crossing through CS / HDPE conduit in all type of soil & terrain, excavated as required, padding, backfilling, etc. including supply of HDPE Duct accessories required including plastic couplers, end plugs, cable sealing plugs, end caps, etc. suitable & sufficient for above supplied ducts, cleaning and sealing of ducts at the end laid drum lengths, preparation and supply of cable blowing pit at each Km jointing of HDPE conduit, testing OD HDPE Duct and accessories after laying preparation of report and final drawing and documents as per specification, joint location marking, erection accessories, as-built, etc.
Blowing of Optical Fibre Cable inside Inside HDPE Duct: All activities pertaining to Blowing of Optical Fibre Cable in same pipeline trench directly (after testing drum at site), through CS / HDPE conduits along the pipeline also at crossing cable, sealing using all materials required, including laying of warning mats, etc. as per direction of EIC
Supply and laying of GI Pipe (4") at crossings for protection of OFC / HDPE duct
Splicing, Jointing of Optical Fiber Cable (Including Supply and Installation of jointing pits including sand, etc. & joint markers)
Supply of FTC with pig tails other accessories for termination of OFC - 24 Fibre in the Telecom Room
Installation of FTC & Wire mesh termination of OFC on FTC / DDF inside telecom room, splicing with steet fibre, fibre test, OTDR test, power testing of laid OFC, identification of fault, rectification, earthing, final testing and commissioning, preparation of reports, etc. work complete in all respect with all necessary accessories for all location till final Handing Over and Taking Over by Owner of laid OFC.
Dismantling and Re-Installation of Telecom System, Electrical panel, RTU, Scada Etc. to new Proposed location of SV Staion -06 as per General specification of Erection, Installation, Testing & commisioning of Telecom system, Electrical and Other Equipments and as per the direction of OWNER / CONSULTANT. Completion of job in totality to the satisfaction of EIC. No separate charges shall be paid for manpower, consumables, lifting equipments, handling, tools & tackles used during execution of this activity. Note: (1) The quantities given above against individual items are indicative and shall not be considered to be binding. The quantities may be increased, decreased or deleted at site at the time of actual execution. Procurement shall be done as per actual site condition, approved construction drawings and as per instruction of EIC. The unit rate shall be operated to work out the final payment to the contractor; (2) In each area, quantities given against individual item may be utilised / used for other consumers in same area.
G L GOLDEN (BID ID -852546)
G L GOLDEN (BID ID -852546)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .