| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC NO 8 PLOT NO 35 1ST MAIN ROAD 2ND PHASE PEENYA INDL AREA BANGALORE 560058 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560058 | ₹16.5 L | L1 | Accepted-AOC lowest quoted rate with GST |
| 2 | L2₹17.1 L+₹57,574 (3.49%)Rejected-AOC | ₹17.1 L+₹57,574 (3.49%) | L2 | Rejected-AOC L2 , Second lowest |
| 3 | Not Admitted-Finance | - | - | Not Admitted-Finance Others- Bid document Volume I not submitted or uploaded. Submitted documents not properly filledup.GTP not filled. BOQ submitted without GST. He submitted a letter informing that he is a GST registered contractor and he had inadvertently omitted the GST. |
| Sl No | Description | Qty | Unit | Avana Electrosystems Pvt. Ltd L1 | JALK ELECTRICAL ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Numerical line differential protection relay, MAKE: HITACHI, RED 670, 2.2.6 version, CTR 400/1A, PTR: 110kV/110V ac with 24 inputs and 30 outputs with built in distance protection, dir with OC/EF protection, SOTF, PSB, Broken conductor, VT fuse failure, LBB protection, under and over frequency protection, check synchronization, disturbance recorder, UV/OV protection, double end fault location, Cyber security with RBAC feature and dual redundancies. IEDs shall have dual FO ports for IEC 61850 Edition- 2.1 and PRP compatibility and a minimum of 4 nos. fixed LEDs and 15 nos. programmable LEDs for indication. All IEDs shall have IRIG-B/SNTP/PTP port for time synchronization. USB/RJ45 ports shall also be provided on both front and rear side of the relays for communication with laptop. Shall have large display with SLD. | 1 | No | 5,32,650 ₹6,28,527 Lowest | 7,19,400 ₹8,48,892 |
| 2.00 | Numerical Line Differential Relay, Type MICOM P545, Builtin Distance Protection Relay, CTR:400/1A, PTR: 110kV/110V AC,24 Binary Inputs & 32 Relay Outputs, With Buit In Dir. OC/EF Protection, VT Fuse Failure, SOTF, PSB, LBB, Under & Over Frequency Protections, Disturbance Recorder, UV/OV, Check Synchronization, Broken Conductor. IEDs shall have dual FO ports for IEC 61850 Edition-2 and PRP compatibility and a minimum of 4 nos. fixed LEDs and 15 nos. programmable LEDs for indication. All IEDs shall have IRIG-B/SNTP port for time synchronization. USB/RJ45 ports shall also be provided on both front and rear side of the relays for communication with laptop.
Aux. Supply: 110V DC, (P54591RC650790M) | 1 | No | 4,82,435 ₹5,69,273 | 4,45,000 ₹5,25,100 Lowest |
| 3.00 | DC Supervision Relay
Type VAA11, Aux. Relay, 2NO+2C/O SR contacts, H/R Reverse Flag Indication, Aux. Supply: 110V DC for DC Supply Supervision-GE make | 1 | No | 5,862 ₹6,917 | 2,888 ₹3,407 Lowest |
| 4.00 | AC Supervision Relay
Type VAA11, Aux. Relay, 2NO+2C/O SR contacts, H/R Reverse Flag Indication, Aux. Supply: 240V AC for AC Supply Supervision- GE make | 1 | No | 6,430 ₹7,587 | 2,888 ₹3,407 Lowest |
| 5.00 | Trip Circuit Supervision Relay
GE make - MVAJM 15 | 1 | No | 15,322 ₹18,080 | 11,800 ₹13,924 Lowest |
| 6.00 | 6. Multi function transducer
Multifunction Transducer, 3ph, 3ele, 4 Wire, Programmable 4 Output (4-20mA) Transducer Ptr: 110kV/ 110V, With RS-485 MODBUS Comm Protocol, Cl:0.2, Aux. Supply : 110V DC
Make Required: MINILEC | 1 | No | 17,470 ₹20,615 | 16,236 ₹19,158 Lowest |
| 7.00 | 7. Multi function meter
Digital Multifunction Meter, 3ELE, 3ph, 4W System Suitable For Voltage, Current, Frequency, Power Factor, Active & Reactive Power Measuring Parameters, With IEC61850 Protocol On 1 RJ45 Port For Scada Communication, Class: 0.2S, PTR: 110kV/110V AC, CTR: 400/1A, Aux. Supply: 110V DC, Case: 96 Sqmm
Make and model required: SECURE ELITE 500 | 1 | No | 1,32,250 ₹1,56,055 | 34,100 ₹40,238 Lowest |
| 8.00 | ABT Energy meter class 0.2s (Apex -150- Secure make/ L&T ER300P) | 2 | No | 2,04,500 ₹2,41,310 Lowest | 2,13,400 ₹2,51,812 |
Tender Value
₹13.6 L
EMD Value
₹34,100
Closing Date
30 Mar 2026, 5:00 pmClosed
Deputy Chief Engineer
Office of the Deputy Chief Engineer Transmission Circle Kottarakkara Kollam Dist
Procurement of spares for 110 kV control and relay panels with cable differential scheme in connection with providing connectivity at 110 kV level to the proposed 110 kV Traction Substation, Punalur on work deposit basis for Railways.
2026_KSEB_846493_1
TCK 04/ 2025-26 Dated 11.03.2026
Open Tender
Equipments
Supply
120 days
Punalur
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,900
₹34,100
Yes
7 Jul 2026
13 Mar 2026
7 Apr 2026
16 Mar 2026
30 Mar 2026
16 Mar 2026
16 Mar 2026 - 23 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Numerical line differential protection relay, MAKE: HITACHI, RED 670, 2.2.6 version, CTR 400/1A, PTR: 110kV/110V ac with 24 inputs and 30 outputs with built in distance protection, dir with OC/EF protection, SOTF, PSB, Broken conductor, VT fuse failure, LBB protection, under and over frequency protection, check synchronization, disturbance recorder, UV/OV protection, double end fault location, Cyber security with RBAC feature and dual redundancies. IEDs shall have dual FO ports for IEC 61850 Edition- 2.1 and PRP compatibility and a minimum of 4 nos. fixed LEDs and 15 nos. programmable LEDs for indication. All IEDs shall have IRIG-B/SNTP/PTP port for time synchronization. USB/RJ45 ports shall also be provided on both front and rear side of the relays for communication with laptop. Shall have large display with SLD. | 1 | No | - | - |
| 2 | Numerical Line Differential Relay, Type MICOM P545, Builtin Distance Protection Relay, CTR:400/1A, PTR: 110kV/110V AC,24 Binary Inputs & 32 Relay Outputs, With Buit In Dir. OC/EF Protection, VT Fuse Failure, SOTF, PSB, LBB, Under & Over Frequency Protections, Disturbance Recorder, UV/OV, Check Synchronization, Broken Conductor. IEDs shall have dual FO ports for IEC 61850 Edition-2 and PRP compatibility and a minimum of 4 nos. fixed LEDs and 15 nos. programmable LEDs for indication. All IEDs shall have IRIG-B/SNTP port for time synchronization. USB/RJ45 ports shall also be provided on both front and rear side of the relays for communication with laptop.
Aux. Supply: 110V DC, (P54591RC650790M) | 1 | No | - | - |
| 3 | DC Supervision Relay
Type VAA11, Aux. Relay, 2NO+2C/O SR contacts, H/R Reverse Flag Indication, Aux. Supply: 110V DC for DC Supply Supervision-GE make | 1 | No | - | - |
| 4 | AC Supervision Relay
Type VAA11, Aux. Relay, 2NO+2C/O SR contacts, H/R Reverse Flag Indication, Aux. Supply: 240V AC for AC Supply Supervision- GE make | 1 | No | - | - |
| 5 | Trip Circuit Supervision Relay
GE make - MVAJM 15 | 1 | No | - | - |
| 6 | 6. Multi function transducer
Multifunction Transducer, 3ph, 3ele, 4 Wire, Programmable 4 Output (4-20mA) Transducer Ptr: 110kV/ 110V, With RS-485 MODBUS Comm Protocol, Cl:0.2, Aux. Supply : 110V DC
Make Required: MINILEC | 1 | No | - | - |
| 7 | 7. Multi function meter
Digital Multifunction Meter, 3ELE, 3ph, 4W System Suitable For Voltage, Current, Frequency, Power Factor, Active & Reactive Power Measuring Parameters, With IEC61850 Protocol On 1 RJ45 Port For Scada Communication, Class: 0.2S, PTR: 110kV/110V AC, CTR: 400/1A, Aux. Supply: 110V DC, Case: 96 Sqmm
Make and model required: SECURE ELITE 500 | 1 | No | - | - |
| 8 | ABT Energy meter class 0.2s (Apex -150- Secure make/ L&T ER300P) | 2 | No | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
vol1.pdf
Tender Documents • 0.35 MB
vol2.pdf
Tender Documents • 0.90 MB
BOQ_1431618.xls
BOQ • 0.32 MB
cor3.pdf
PDF • 0.68 MB
cor2.pdf
PDF • 0.68 MB
Cor.pdf
PDF • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .