Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC EDALAKADU THABORE P O MOOKANNOOR ERNAKULAM DIST KERALA 683 577 | MOOKANNOOR | ERNAKULAM | KERALA | 683577 | L1 | Accepted-AOC lowest tenderer | |
| 2 | L2₹24.5 L+₹22,050 (0.91%)Rejected-Finance 39 359 B PULICKAL THIRUVAMBADY POST ALAPPUZHA KERALA PIN 688 002 | ALAPPUZHA | ALAPPUZHA | KERALA | 688002 | L2 | Rejected-Finance Other than Lowest tenderer | |
| 3 | L3₹26.5 L+₹2.3 L (9.38%)Rejected-Finance MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | L3 | Rejected-Finance Other than Lowest tenderer | |
| 4 | L4₹27.1 L+₹2.8 L (11.6%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest tenderer | |
| 5 | L5₹27.3 L+₹3.0 L (12.5%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest tenderer |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
15 Jul 2021, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services, Garrison Engineer (Naval Services), Kataribagh, Naval Base Post, Kochi, 682 004.
REPAIR/MAINT OF LT UG CABLE, OVER HEAD LINE AND CONNECTED SERVICES, PANELS ETC, STREET LIGHT, SOLAR LIGHT, SECURITY LIGHT, LAMP POST AND CONNECTED WORKS AT NAD ALWAYE AREA UNDER AGE B/R ALWAYE
2021_MES_447359_1
8802/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
ALUVA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹59,000
Yes
29 Sept 2021
1 Jun 2021
17 Jul 2021
1 Jun 2021
15 Jul 2021
13 Jun 2021
1 Jun 2021 - 12 Jun 2021
Amount
Excavation in trenches in Soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying pipes, cables etc. and getting out complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed.
Supply and laying fine dry river sand to entire width of trench as cable cushion in trench for cable complete as specified
Supply & lay un reinforced pre cast concrete cable cover class LV type 1 flat size 250mmx150mmx40mm complete all as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, glavanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10Sqmm 4core including taking out old unserviceable cable complete all as directed.
Ditto all as per Sl Item No 06 above but of size 10Sqmm 2core complete all as directed.
Ditto all as per Sl Item No 06 above but of size 16Sqmm 2core complete all as directed.
Ditto all as per Sl Item No 06 above but of size 25Sqmm 4core complete all as directed.
Ditto all as per Sl Item No 06 above but of size 50Sqmm 3.5core complete all as directed.
Ditto all as per Sl Item No 06 above but of size 70Sqmm 3.5core complete all as directed.
Ditto all as per Sl Item No 06 above but of size 95Sqmm 3.5core complete all as directed.
Ditto all as per Sl Item No 06 above but of size 120Sqmm 3.5core complete all as directed.
Ditto all as per Sl Item No 06 above but of size 240Sqmm 3.5core complete all as directed.
Ditto all as per Sl Item No 06 above but of size 400Sqmm 3.5core complete all as directed.
Supply and fix 3 core flexible copper cables 1.5 Sqmm from Cable junction box to street light fitting with and including ERW Steel conduit of 20mm dia complete all as directed.
Material & Labour for horizontal bore drilling of suitable dia holes for insertion/ laying of 40/50/100mm bore GI Tubing of any description below/under existing road surfaces / floors at a level not less than 0.60 metre etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed by Engineer-in-Charge. Note: Cost of equipment tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the department.
Supply & laying in replacement of Galvanised steel tubing of size 100mm bore, medium grade to be fixed on walls or laid under roads for passing cables complete as specified and as directed.
Ditto all as per Sl item 18 above but of size 50mm bore.
Ditto all as per Sl item 18 above but of size 40mm bore.
Material and Labour for GI steel wire 4mm dia for continuous earthing on poles for guarding cordless hexagonal or rectangular including stringing and connected to earth wire complete all as specified and directed.
Supply & Fix hot dipped GI octagonal pole of 6 metres long with single arm, complete arrangement suitable for mounting of LED light fitting, with bottom dia 130mm, top dia 70mm with 3mm sheet thickness with and foundation nut, bolts complete including necessary earth work excavation and PCC as per OEM Drawings complete all as specified and directed.
Supply and fix Outdoor type, weather proof, thermoplastic polycarbonate cable Junction Box of size 205 x 255 x 112 mm, IP-66/69 in accordance with IEC60529 , with 5 pole terminal suitable to terminate up to 25 sqmm 4 core and 2 core cables with metric knockouts on side walls complete all as specified and directed.
Supply and fix in repairs MCB SPN 6 to 32 Amps, 'C' series complete all as specified and directed.
Supply and fixing new generation energy saving and environmental friendly long life LED Street light 90 watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having Top Opening separate driver compartment with IP66 Protection and impact resistance of IK07 with 10KV Built-in Surge protection device complete all as specified and directed.
Ditto all as per sl item No 25 here in before but of 70/72 watt.
Ditto all as per sl item No 25 here in before but of 60 watt.
Ditto all as per sl item No 25 here in before but of 50 watt.
Ditto all as per sl item No 25 here in before but of 30 watt.
Material and labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate for erection of pole, repair of road cuttings etc compete all as specified and directed by Engineer-in-Charge.
Supply and Fixing GI bracket 40mm dia made out of medium grade pipe of 1.2 m length in bending 120 degree shape including clamp of flat iron with nut bolts washers including taking down old unserviceable bracket compete all as specified and directed
Supply and fixing 10 watt IP 65 Rated pyramid tripod type LED Bollard with soft 360 degree light distribution including fixing arrangement compete all as specified and directed.
Supply and fixing 12 Watt new generation, cone round milky Post-Top lantern, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, landscape luminaries with high power LED as lighting source with IP65 Protection compete all as specified and directed
Supply and fixing new generation energy saving and environmental friendly long life LED Flood light 250 watt made up of pressure die cast aluminium housing with high power LEDs and secondary lenses with IP66 Protection System efficacy > 110LPW with 10KV Built-in Surge protection device compete all as specified and directed
Ditto as per Sl item No 34 but for 150 watt.
Supply & Fix 25W all in one solar LED Street light fitting with inbuilt lithium battery, mono crystalline solar panel of 45Wp, efficiency of 120 Lumen/Watt, MPPT + AC-DC LED Driver, 30 AH lithium ferro phosphate (LiFeP04) battery,2 days backup, hybrid with 10KV-5KA SPD operating voltage 180V - 230V,PIR motion sensor (Active PIR: light glows to 100% for 30 seconds upon motion detection returns to 30% after that) suitable for mounting on pole complete all as specified and directed.
Supply & Fix 20W all in one solar LED Street light fitting with inbuilt lithium battery, mono crystalline solar panel of 40Wp, efficiency of 120 Lumen/Watt, MPPT + AC-DC LED Driver, 12.8V/24 AH lithium ferro phosphate (LiFeP04) battery,2 days backup, hybrid with 10KV-5KA SPD operating voltage 180V - 230V,PIR motion sensor (Active PIR: light glows to 100% for 30 seconds upon motion detection returns to 30% after that) suitable for mounting on pole complete all as specified and directed.
Supply & Fix Surge protection device 10 KV as per existing one.
Supply & Fix LED street light Driver 30W to 100W as per existing one.
Supply and Fix Earthing of Poles with GI wire 4mm dia with galvanised MS earth plate of size 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below ground level, earth plate shall be packed on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected to GI earth wire 4mm dia (8 SWG) protected by GI pipe 15mm bore (light grade) and watering pipe 20 mm dia (medium grade) of suitable length, with necessary earth work including disposal of surplus soil to a distance not less than 50 metre, PCC pit chamber with RCC cover frame, funnel, wire mesh. The GI earth wire 8 SWG under the earth and on the pole up to a height of 1.5 meter shall also be protected by 15mm dia GI pipe (medium grade) & GI pipe to be fixed with poles by the means of 2 Nos flat iron clamp 25 x 3 mm size complete with bolts, nuts and washers etc. complete all as specified and shown in electrical plate No 3 of SSR Part I - 2009. Note: - Main earthing lead from earth plate to test point & up to 7.5 Metre to be provided. The cost for the same shall be deemed to be included in the above quoted rate.
Material and labour for Sub class ‘B’ bricks, best quality, locally available laid dry flat with width equal to length of brick, over LT underground cable in trenches for mechanical protection of size 23cm x 11.5cm x 7.5cm thick complete all as specified and as directed by the Engineer-in-Charge.
Laying serviceable old bricks retrieved from trenches as directed by the Engineer-in-Charge.
Laying serviceable old concrete cable covers retrieved from trenches as directed by the Engineer-in-Charge.
Material & Labour for cable jointing kit (end termination) Indoor type, heat shrinkable type including all jointing material & accessories suitable for 11000 V Cable aluminium conductor cables of size 50 to 95 Sqmm 3 core cables Including dismantling old one complete all as specified and directed.
Ditto as per Sl item No 44 but for cables of size 120 to 185 Sqmm 3 core.
Material & Labour for cable jointing kit (end termination) Outdoor type, heat shrinkable type including all jointing material & accessories suitable for 11000 V Cable aluminium conductor cables of size 50 to 95 Sqmm 3 core cables Including dismantling old one complete all as specified and directed.
Ditto as per Sl item No 46 but for cables of size 120 to 185 Sqmm 3 core.
Labour for Re-stretching, restraining ACSR conductor laid over, OH LT/HT line on steel/PCC poles after removing the binding from insulators, lowering the ACSR conductor or broken OH line due to any reason, jointing the broken conductor, Re-winding the ACSR with insulators including providing binding wire, jumpering & connecting the existing service cables after re-stretching/Re-straining to OH line & removing unavoidable sag in the lines, span consisting of 4 ACSR wire & one earth wire conductor of any description complete all as specified. Note: Item will be measured as a whole, No single conductor will be paid separately.
Ditto all as per Serial Item no.48 but consisting 2 ACSR LT with one earth wire conductor.
Material & Labour for trimming of tree branches, vegetation bushes etc from below the over head line with a clearance of 2.5mtr on both sides including removal of cutted material at a distance of 50m from work site complete all as specified and directed by Engineer-in-charge (Note: pole to pole distance approximately 40-50 RM Average of each row of LT/HT line shall be measured and paid)
Material & Labour for GI steel wire 4mm dia for continuous earthing on poles for guarding carddles hexagonal or rectangular including stringing and connected to earth wire including dismantling old unserviceable one.
Supply and fixing of aluminium conductor steel reinforced (ACSR) of any size/description on LT poles including stringing, tightening, binding to insulators with aluminium wire and connecting jumpers, connections etc, commissioning and testing including dismantling old unserviceable complete all as specified and as directed by Engineer-in-charge.
Supplying & Fixing Shackle type 75mm height and 90mm dia insulator, porcelain, vitreous, white, brown or green including galvanised mild steel strap 31mm X 3mm, insulator bolts 12mm dia with suitable washers and nut, suitable for working pressure up to & including 1100 volts, complete all as specified and directed by Engineer-in-Charge fixed on LT poles.
Supply and Fix pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two GI washers and one GI iron nut for 1100 volts grade of size 100mm height, 65mm dia complete all as specified and directed.
Material & Labour for removing old burnt jumper connection in binding with HT/LT lines from position including re-binding the same with new binding wire of size 2.00mm aluminium wire complete as directed.
Supply & Fix Heat shrinkable jointing kit straight through joint suitable for LT underground cable of size 10/16/25 Sqmm 4 core,1.1 KV outdoor terminations complete all as specified and directed.
Ditto all as per Serial Item no.56 but of size 50 to 150 sqmm, 3.5 core.
Supply & Fix Heat shrinkable jointing kit straight through joint suitable for LT indoor / outdoor cable end terminal joint (epoxy joints) any type suitable for aluminium conductor cable of size 35 Sq mm to 120 Sq mm 3.5 core complete all as specified and directed.
Ditto all as per Serial Item no. 58 but of size 10 to 25 sqmm, 3.5/4 core.
Material & Labour for cable route indicator 15 cm dia with CI Plate embossing type of cable fix to angle iron of size 40x40x6mm and 45 cm long with necessary fixing arrangement in ground complete all as specified and directed.
Material & Labour for removing complete covers of the LT panel board, cleaning the bus bars with CTC solution, removing the carbon deposits, rust particles etc. tightening the bus bars, bolts, nuts including replacing with required new bolts nuts, insulating the exposed portion with insulating tapes and replacing the damaged insulators/ Hylam sheets etc. and re-fixing the covers and testing complete all as specified and directed.
Supply, laying for replacement of unserviceable underground LT cable 1100 Volts grade heavy duty electric cable XLPE outer sheathing with Copper conductor, Armoured confirming to IS-7098 (Part-I) 1988 with latest amendments of size 10 Sqmm x 4 core including taking out old unserviceable cable complete all as specified and directed.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
St George Engineering Works
Kuriako Mathai and company
Palakkal Agencies
THOMSONS CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .