Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Bid is lowest and reasonable | |
| 2 | L2₹33.3 L+₹1.2 L (3.87%)Rejected-AOC D 9 NETAJI NAGAR KANTATOLI COLONY RANCHI 834001 | RANCHI | RANCHI | JHARKHAND | 834001 | L2 | Rejected-AOC Bid is not lowest and reasonable | |
| 3 | L3₹34.8 L+₹2.7 L (8.35%)Rejected-AOC | L3 | Rejected-AOC Bid is not lowest and reasonable | |
| 4 | L4₹36.8 L+₹4.7 L (14.6%)Rejected-AOC 337 B ROAD NO 04 ASHOK NAGAR RANCHI 834002 JHARKHAND | RANCHI | JHARKHAND | 834002 | L4 | Rejected-AOC Bid is not lowest and reasonable | |
| 5 | L5₹36.9 L+₹4.8 L (15.0%)Rejected-AOC | L5 | Rejected-AOC Bid is not lowest and reasonable |
Tender Value
₹34.5 L
EMD Value
₹69,000
Closing Date
12 Jul 2023, 6:00 pmClosed
GE RAMGARH
GE RAMGARH CANTT
PROVN OF 04X02 TONNE SPLIT TYPE AC WITH STABILIZERS ALONGWITH ALL CONNECTED ACCESSORIES SPECIAL REPAIR FOR REPLACEMENT OF WATER COOLERS DEEP FREEZER AND DESERT COOLER AGAINST BER AND PROVISION OF 25 KVA GENERATOR SET UNDER GE RAMGARH
2023_MES_600159_1
8300/3181/E8
Open Tender
Civil Works
Item Rate
120 days
GE RAMGARH
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE RAMGARH
₹69,000
Yes
16 Aug 2023
1 Jun 2023
14 Jul 2023
1 Jun 2023
12 Jul 2023
15 Jun 2023
Amount
Supply, installation, commissioning and testing Split type wall mounted Air Conditioner, electric driven, single phase, 230 Volts, 50 Hz of capacity 2.0 TR with high efficiency rotary type sealed compressor unit complete with PCB board and with cordless remote control unit operation system with refrigerant gas, BEE minimum 3 star rating, EER 3.2,AC supply complete including copper pipe insulation etc and above complete all as specified and directed with comprising of following .:- (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising of Compressor with motor, air cooled copper condenser with fan and motor unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wall as per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly 2.0 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer shall in quoted rate under this item.
Supply , installation/ fix for 5 KVA capacity Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and as directed.
S & F sheet metal enclosures with socket plug top and MCBs having single pole and nutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp ,"C" series, breaking capacity 10 KA, 240 V complete all as specified and as directed.
M & L for sub main wiring with Two RUNS of single core 4 Sq.mm for main wire and one run of single core 4 Sq.mm as earth wire of multi stranded copper conductor FRLSH PVC insulated unsheathed cable conforming to IS : 694 drawn through and including concealed in PVC coduit conforming to IS : 9537 ( Part-3) and ISI marked not lass than 25 mm dia medium grade and all accessories conforming to IS specification complete all as specified and directed. Note:- Two runs of main wire, one run of earth wire and one run of conduit shall be measured as one unit
Supply and fix sheet metal enclosures for DBs when MCBs to be used single pole & neutral (SPN) double door 240 volts, 4 way with IP-43 IK-09 protection incl. 200 Amp bus bar and neutral link (ISI marked) complete all as specified and directed.
Supply and fixing miniature circuit breaker (MCB) of single pole (SP), 'B' Curve, 240 Volt, breaking capacity 10 KA and current carrying capacity 25 Amp in the MCB DB with connection testing and commissioning complete all as specified and as directed.
Supply and fixing miniature circuit breaker (MCB) of single poles and neutral (SPN), 'B' Curve, 240 Volt, breaking capacity 10 KA and current carrying capacity 63A Amp in the MCB DB with connection testing and commissioning complete all as specified and as directed.
Supply, laying , jointing & testing 1100 Volt XLPE insulated,screened ,PVC bedded, galvanised steel strip or wire armoured, electirc power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 16 Sq mm 2.0 core complete all as specified and directed.
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated soil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
Supplying & Laying sub class "B" bricks old size with axis of the bricks perpendicular to the axis of the cable as cable protection complete all as specified and directed by the Engineer-in-Charge.
M&L ,for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by GI pipe 15 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade) and PCC of chamber and coping shall in 1:3:6 type C-1 using 20 mm graded stone aggregate including excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate No 3 of SSR Pt-I, 2009 with 40 mm thick pre cast cover RCC 1:2:4 type B-1 (using 20 mm graded crushed tone aggregate) with 8mm dia TMT Bars @ 150mm c/c in both ways with charcoal dust and common salt complete and earth lead connected to panel including testing including taking down existing earthing complete all as specified and directed.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and directed..
Supply, installation, commissioning of Glass Top Deep Freezer single phase 240 volt, 50 Hz of capacity 320 Ltr ,BEE 5 star rated ,frost free suitable for 250 V with auto stabilizer free operation of approved shade and make complete all as specified and directed.
Supply, installation, commissioning of Glass Top Deep Freezer single phase 240 volt, 50 Hz of capacity 205 Ltr ,BEE 5 star rated ,frost free suitable for 250 V with auto stabilizer free operation of approved shade and make complete all as specified and directed.
Supply and fix desert cooler electric driven single phase, 3 speed, ABS body with wood wool cooling media, 4000 cum per hrs min flow, 55 Ltrs tank capacity with castor wheels stand suitable for mounting and operation on 230 volts, power consumption not exceeding 200 watt complete all as specified and directed at site complete all as specified and directed.
Supply and fix desert cooler electric driven single phase, 3 speed, ABS body with wood wool cooling media, 4000 cum per hrs min flow, 75 Ltrs tank capacity with castor wheels stand suitable for mounting and operation on 230 volts, power consumption not exceeding 200 watt complete all as specified and directed at site complete all as specified and directed.
Supply, laying , jointing & testing 1100 Volt XLPE insulated,screened ,PVC bedded, galvanised steel strip or wire armoured, electirc power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 50 Sq mm 3.5 core complete all as specified and directed.
Supplying and laying un-reinforced pre cast concrete cable cover class LV, Type - 1 , flat, size 250 mm x 150 mm x 40 mm complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying for 50 mm bore HDPE pipe of pressure rating 6 kgf/cm^2 fixed with all necessary fittings for cable protection in walls, ceilings, floors, road etc complete all as specified and as directed.
M & L earthing complete with Gl electrode 600x600x6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to Gl earth strip 32 mm X6 mm as earthing leaad by means of bolts, nuts, check nuts and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil including 40 mm dia Gl tubing light grade and necessary fitting for protection of Gl strip including laying of charcoal, dust and common salt PCC (1:3:6) type C-l( using 20 mm graded crushed stone aggregate) earth pit with 40x40x6mm mild steel angle iron frame & 40mm thick pre cast RCC cover (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) reinforced with 8mm dia TMT bars @ 75mm C/C both way with mild steel handle 12 mm dia round bars ,10mm thick plastering with cement mortar (1:4) internally and upto 150 mm below ground level externally, PGI funnel with wire mesh 20mm dia Gl pipe for watering complete all as shown on electrical plate No.3 of SSR Part -1 2009 and connected in earth test including testing completed all specified and directed.Note: Earth strip and its protection pipe up to and including 7.5 mtr only from the top of earth electrode.
M/s Kundu Enterprises
M/S Akash Enterprises
Excel Enterprises
M/s friend enterprises
ranjit singh
M/S Bhushan Kumar Jain
om suppler
M/s Ray construction
M/s Vinay Kumar
upadhyay engineers and consultant
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .