Rehabilitation of existing Storm Water /Drainage Line from Shahpur metro station to Dariyapur circle to Prem Darwaja in Central Zone of Ahmedabad Municipal Corporation
272659
2025-2026
Open
Miscellaneous Works
Works
Ahmedabad
3 documents required · 3 mandatory
₹18,000
Municipal Commissioner, Ahmedabad
₹29.6 L
4 Feb 2026
4 Feb 2026
4 Feb 2026
25 Feb 2026
4 Feb 2026
Rehabilitation of existing pipeline by GRP Structural lining method including site survey, plugging and flow diversion, cleaning, pre lining CCTV, Repair of defects, pre lining measurement, designing, site preparatory work, installation of GRP liner, jointing, grouting, post lining CCTV and measurement, rehabilitation of machine hole, testing and commissioning and restoration of roads and surfaces all inclusive as per IndSTT: 202-2018° Code of Practice for GRP Lining Technique Suiting Indian Condition. (AS PER indSTT 2025 Page-no-45,Item No.3.1.1,2,3,4,5,6) From 750 - 900 mm dia.
From 950 - 1000 mm dia.
From 1050 - 1200 mm dia.
From 1250 - 1400 mm dia.
From 1450 - 1500 mm dia.
From 1550 - 1700 mm dia.
Cured in Place Pipe (CIPP) lining using Hot water/Steam curing/ of resin impregneted felt.Rehabilitation of existing pipeline by CIPP Cured in Place Pipe Structural lining method including site survey, plugging and flow diversion, cleaning, pre lining CCTV, Repair of defects, pre lining measurement, designing, site preparatory work, installation of (CIPP) resin impregnated liner,curing of liner using hot water/ steam recirculation, post lining CCTV and measurement, rehabilitation of machine hole, testing and commissioning and restoration of roads and surfaces all inclusive as per IndSTT: 201-2018° Code of Practice for Cured in Place Pipe Technique Suiting Indian Condition.indSTT 2025 (AS PER indSTT 2025,Page no-46, Item No.3.2.1,5,6,7,8,9,10,11) 550 mm to 600 mm dia.
650 mm to 750 mm dia.
800 mm to 900 mm dia.
950 mm to 1000 mm dia.
1100 mm to 1200 mm dia.
1250 mm to 1400 mm dia.
1450 mm to 1500 mm dia.
Rehabilitation of existing pipeline by MWSL Structural lining method including site survey, plugging and flow diversion, cleaning, pre lining CCTV, Repair of defects, pre lining measurement, designing, site preparatory work, installation of GRP liner, jointing, grouting, post lining CCTV and measurement, rehabilitation of machine hole, testing and commissioning and restoration of roads and surfaces all inclusive as per IndSTT: 203-2022° Code of Practice for Machine Wound Spiral Lining Technique Suiting Indian Condition.(AS PER indSTT 2025,Page no-49, Item No.3.4,6,7,8,9,10,11) From 650 - 700 mm dia.
From 800 - 900 mm dia.
From 950 - 1000 mm dia.
From 1000 - 1200 mm dia.
From 1250 - 1400 mm dia.
From 1450 - 1500 mm dia.
Renovation of machine hole by increasing the height at top including cost of excavation, refitting of C. I. machine hole frame and cover curing etc. complete incl. all carting and providing of materials which is required for the purpose (except machine hole frame and cover) (SOR GWSSB 2022-2023 SECTION-D Item No 10 Page No 103)For all type machine hole by providing RCC 1:2:4 Partition walls with required reinforcement 25 cm thick and circular opening with 500mm clear dia and 0.40 mt. av. ht.
Excavation in bituminous road as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts as specified.(SOR GWSSB 2022-2023 SECTION-B Item No 02 Page No 33 ) 2000 mm dia. storm water drainage line
Excavation for pipe line trenches for water supply, Storm Water line, machine hole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified.In all sorts of soil and soft murrum (SOR GWSSB 2022-2023 SECTION-B Item No 01 Page No 32) 1200 mm dia. Storm Water/Drainage line UPTO 4.50 mt depth Upto 1.50 mt depth
1.50 mt to 3.00 mt depth
3.00 mt to 4.50 mt depth
Temporary / Permanent Plugging for blocking of storm water drainage line, branch connections for diversion of flows and removal of all plugs by any means etc. complete as directed by Engineer In Charge of the work. (SOR GWSSB 2022-2023 SECTION-D Item No 06 Page No 102) 600mm to 700 mm dia. Sewer line
900mm Sewer line
1000mm Sewer line
1200mm Sewer line
1400 mm dia. drainage line
Providing and supplying ISI Standard R.C.C. NP3 pipes(of Sulphate Resisting Cement) in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. One collar should be supplied with each full length plain ended RCC pipe, cost included in rates below. One rubber ring should be supplied with each full length socketed pipe, cost included in rates below. (SOR GWSSB 2022-2023 SECTION-A Item No 10.2A-10 Page No 16) 1200 mm dia. RCC Pipe line
1400 mm dia. RCC Pipe line
Lowering, laying and jointing R. C. C. pipes including of following diameters in proper position, grade and alignment at all level as directed by Engineer-in-charge including conveyance from stores to site of work, labour, giving hydraulic testing as per ISI code. (SOR GWSSB 2022-2023 SECTION-B Item No 11.B 21 Page No 39) 1200 mm dia. RCC Pipe line
1400 mm dia. RCC Pipe line
Refilling the pipeline trenches incl. ramming, watering, consolidating disposal of surplus stuff as directed within a radius of 3 km. (SOR GWSSB 2022-2023 SECTION-B Item No 14 Page No 40) Refilling as directed
Conveyance charge of earth, lime, murrum, building rubbish, Manual garbage, Sludge, Excavated rock, Fly ash, Aggregate of any any kind etc. complete. Upto 5.0 Km lead(SCHEDULE OF RATES FOR R& B YEAR:- 2022-23)
Providing and constructing machine holes, scraper machine holes and unit house connection chamber, as per the type design in brick masonry in C M 1 5 and inside and outside 20mm thick plastering in C. M 1.3 necessary 100 mm coping with reinforcement in RCCM 200 fixing C I steps and fixing machine hole frame and covers (But excluding supply of machine hole frame and covers) over machine holes and house connection chambers and fixing machine hole covers (but excluding supplying of machine hole covers) over scraper machine hole etc complete, providing and fixing safety chain wherever necessary as per the stipulations in the type design complete as per latest CPHEEO manual (excl. excavation) (SOR GWSSB 2022-2023 SECTION-D Item No 02 Page No 101) Scraper machine hole type "S1" rectangular type for 600 to 1200 mm dia storm water drainage pipes and for depth 2.5m to 9.0m Scraper machine hole type "S1" as above but upto 2.5m
Extra depth beyond 2.5 m and upto 9.0 m depth for type "S1" scraper machine hole above.
Scraper machine hole type "S2" rectangular type for 1400 mm dia storm water drainage pipes and for depth 2.5m to 9.0m Scraper machine hole type "S1" as above but upto 2.5m
Extra depth beyond 2.5 m and upto 9.0 m depth for type "S2" scraper machine hole above.
F.R.C. ExtraHeavyDuty (EHD-35) ManholeCovers & Frames Cover : 728mmø&100mmthickcircular cover, 35.00 MT load design, 100x2mm MS flat all round,16mmø plain round bar for lifting thecover &should be fitted with plastic cups.Frame:560mmø clear opening, outer size 888 x 888 x175 mm.On the upper periphery of frame25x3 mm wide MS flat should bewell embed in concrete to protect theedgesof frame.FRCE.H.D. 35manholecover& frame described as above SOR - (Jan. 2016) Rates for work of Drainage / SWD pipe line(AMC)
C.C. M-20 Nominal Mix (with w.p.chemical) Providing and cast in situ C.C. in grade M-20 (approx. corresp. to prop. 1:1.5:3) (proportions as per mix design or as per table9 of IS456 2000 in masses by weigh batching) using quartzite trap metal of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding centering form work, needle vibrated consolidation, curing an hydraulic testing etc. complete (excluding cost of reinforcement) with centering and shuttering/deshuttering etc. complete up to 6 meter height/depth from Av. G.L. for all structures with water proofing compound.(SOR GWSSB 2022-2023 SECTION-C Item No.05 Page No 43) For,Bottom slab or floor slab-without shuttering (SOR GWSSB 2022-2023 SECTION-C Item No.5.2 Page No 43)
For, VERTICAL WALL above 15 cm upto 20 CM (SOR GWSSB 2022-2023 SECTION-C Item No.5.7 Page No 44)
Providing TMT Bar FE415 reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level SCHEDULE OF RATES FOR BUILDING WORKS AHMEDABAD CITY (WITHOUT GST) YEAR:-2023-24 Item no 5.4.11 pg.54
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
COC Sahpur to Prem Darwaja_11zon.pdf
TS Sahpur to Prem Darwaja.pdf
BOQ Sahpur to Prem Darwaja.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .