Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹14.3 L+₹1.5 L (11.8%)Rejected-Finance BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L2 | Rejected-Finance Not being lowest tenderer | |
| 3 | L3₹16.1 L+₹3.3 L (25.9%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tenderer | |
| 4 | L4₹16.1 L+₹3.3 L (26.2%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tenderer | |
| 5 | L5₹18.2 L+₹5.4 L (42.4%)Rejected-Finance | L5 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
12 Jun 2023, 6:00 pmClosed
GE RANIKHET
GE (MES) RANIKHET
CERTAIN REPAIR MAINT OF INTERNAL ELECTRIFICATION WITH BLDG SECURITY LIGHT PERIMETER SECURITY LIGHT AND MAINT OF HEATING AND COOLING APPLIANCES AT HALDWANI STATION UNDER GE RANIKHET
2023_MES_594828_1
GE/RKT/25 OF 2023-24
Open Tender
Civil Works
Item Rate
270 days
Haldwani under GE Ranikhet
Class E, Cat b (i)
7 documents required · 7 mandatory
₹500
GE RANIKHET
₹46,000
28 Aug 2023
12 May 2023
20 Jun 2023
12 May 2023
12 Jun 2023
27 May 2023
Amount
BOQ ( Sch 'A') Taking down carefully aluminium/copper wiring of any size (for light, fan, socket or power etc complete) including fixture and fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights, bells etc and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and as directed..
Supply & Fixing point wiring for one light point/ fan point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS) PVC cable drawn into & including PVC casing/capping and accessories including sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor (FRLS) cable earth wire and connected to earth, etc and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed (Note:- wiring shall be done in colour coding as directed by Engineer in charge)
All as per item No.02 above but one bell point controlled by one switch
All as per item No.02 above but one light point controlled by one two way switch
All as per item No.02 above but one socket outlet 5 Amps on the same board.
All as per item No.02 above but one socket outlet 5 Amps on independent board
All as per item No 02 above but wiring with 2.5sqmm copper wire (FRLS) PVC and 2.5 sqmm earth (FRLS) wire for socket outlet 5 pin 15 amps on independent board.
All as per item No 02 here in before but wiring with 4.0sqmm copper wire (FRLS) PVC and 4.0 sqmm earth wire (FRLS) for socket outlet 5 pin 15 amps on independent board.
Supply & Fixing point wiring for one light point/ fan point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS) PVC cable drawn into & including medium grade PVC conduit (not less than 20mm outer dia) with all fittings and accessories fixed concealed (including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) and sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable (FRLS) earth wire and connected to earth etc and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed (Note:- wiring shall be done in colour coding as directed by Engineer in charge.)
All as per item No.09 above but one bell point controlled by one switch.
All as per item No.09 above but one light point controlled by one two way switch.
All as per item No.09 above but one socket outlet 5 Amps on the same board.
All as per item No.09 above but one socket outlet 5 Amps on independent board
All as per item No 09 above but wiring with 2.5 sqmm copper wire (FRLS) PVC and 1.5 sqmm earth wire (FRLS) cable for socket outlet 5 pin 15 amps on independent board.
All as per item No 09 here-in-before but wiring with 4.0 sqmm copper wire (FRLS) PVC and 4.0 sqmm earth wire (FRLS) cable for socket outlet 5 pin 15 amps on independent board.
Supply & Fixing lamp holder (dome type) PVC insulated body with cord grip cap for angle/battern fitting complete all as specified and directed.
Suppy & Fixing switch piano flush type single pole, one way 6 Amp complete all as specified and directed.
Supply & Fixing switch piano, flush type single pole 15 Amp complete all as specified and directed.
Suppy & Fixing switch piano flush type single pole, two way 6 Amp complete all as specified and directed.
Supply & Fixing socket outlet 2 in 1, 3 pin, 6 Amp and 16 Amp flush type complete all as specified and directed.
Supply & Fixing socket outlet 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed.
Supply & Fixing Bell push, flush type, 6 Amp complete all as specified and directed.
Supply & Fixing steped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
Supply & fixing Bell AC 230 volts, 50 Hz single pole complete all as specified and directed.
Supply & Fixing ceiling rose, PVC/ Poly carbonate, isolated body three terminal complete all as specified and directed.
Supply and fixing of 6 Amp one way switch, 1 module, modular type ,white polycarbonate,switches, sockets, fan regulator suitable for 250V, AC, 50Hz. electrical supply complete all as specified and directed.
All as per item No.26 above but 6 Amp two way switch, 1 module
All as per item No. 26 above but modular 6 Amp 2/3 Pin combined socket shuttered, 2 module
All as per item No. 26 above but Modular Switch 1 way 16 Amp, 1 Module
All as per item No. 26 above but Modular socket 6A/16Amp, 2/3 pin combined, 2 Module
All as per item No. 26 above but 6 Amp bell push switch modular type
All as per item No. 26 above but Steped type electronic fan regulator modular, 120W-2 module
Supply and fixing of modular front plates, 2 Module white with frame on existing boxes complete as required complete all as specified and directed.
All as per item No. 33 above but 3 Module
All as per item No. 33 above but 4 Module
All as per item No. 33 above but 6 Module
All as per item No. 33 above but 8 Module
Supply and fixing anodised rust proof 18 SWG MS box, flush type (1-2 Module) (to be of same make as modular switches and sockets) to be recessed in wall /gypsum partition complete as required complete all as specified and directed.
All as per item No. 38 above but (3 Module)
All as per item No. 38 above but (4 Module)
All as per item No. 38 above but (6-8 Module)
Supply & Fixing sheet metal enclosure with socket plug top and MCBs Single pole and neutral enclosure 240 Volt with a two pin and earth plug and socket complete with on single pole MCB 20 Amp complete including taking down unserviceable sheet metal enclosure of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed.
Supply & Fixing sheet metal enclosure for DBs(double door type) single pole and neutral 4 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed including taking down unserviceable main switches MCB DB’s of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed.
All as per item No. 43 above but 8 way
All as per item No. 43 above but 12 way
Supply & Fixing sheet metal enclosure for DBs(double door type) Triple pole and neutral 4 way including blanking plate as required with 200 Amps rated bus bar, 415 volts fixed and concealed in wall including taking down unserviceable main switches MCB DB’s of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed.
All as per item No. 46 above but 6 way
M&L for surface mounted rectangular/square type box of size 1-2 module for mounting of modular/piano type switches, sockets, fan regulator etc as per site requirement incl fixed with screws and cup washers and taking down unserviceable switch board of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed.
All as per item No. 48 above but 3 module
All as per item No. 48 above but 4 module
All as per item No. 48 above but 6-8 module
Supplied & Fixing Rigid non matallic PVC conduits external dia 20 mm ISI marked exclusive of boxes (Junction/terminal) but inclusive of all tee, bends, elbows, reducers, bell mounth tube ends and fixing accessories such as couplers, lock, nuts, saddles, pipe hooks etc for exiting point/main/sub-main wiring complete all as specified and directed.
Supply & Fixing 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed .
Supply & Fixing 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole neutral (SPN) and current carrying capacity 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed .
Supply & Fixing 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole neutral (SPN) and current carrying capacity 40 to 63 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed .
Supply & Fixing 415V, 10KA 'B' curve miniature circuit breaker (MCB) of triple pole neutral/four pole (TPN/FP) and current carrying capacity 40 to 100 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed .
Material and labour for Sub main wiring with 2 run of 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and multi stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive of junction/terminal boxes, all fittings and accessories fixed concealed with and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and multi stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including chase cutting and making good surface as original by plastering and white/ colour wash/ distempering etc including taking down existing old sub main wiring complete all as specified. Note :1 The cost of earth wire is included in the quoted rates. 2. Two run of 2.5 sqmm sub main wire and one run of 1.5 Sqmm copper conductor cable as earth wire applicable incl PVC conduit will be measured as one unit ie one running metre”
All as per item No. 57 above but 2 X 4 Sqmm inclusive 4 Sqmm earth wire. Note :1 The cost of earth wire is included in the quoted rates. 2. Two run of 4 sqmm of sub main wire and one run of 4 Sqmm copper conductor cable as earth wire applicable incl PVC conduit will be measured as one unit ie one running metre”
All as per item No 57 above but 2 X 6 Sqmm inclusive 6 Sqmm earth wire. Note :1 The cost of earth wire is included in the quoted rates. 2. Two run of 6 sqmm of sub main wire and one run of 6 Sqmm copper conductor cable as earth wire applicable incl PVC conduit will be measured as one unit ie one running metre”
All as per item No. 57 here in before but 2 X 10Sqmm inclusive 10 Sqmm earth wire. Note :1 The cost of earth wire is included in the quoted rates. 2. Two run of 10 sqmm of sub main wire and one run of 10 Sqmm copper conductor cable as earth wire applicable incl PVC conduit will be measured as one unit ie one running metre”
Material and labour for Sub main wiring with 2 run of 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and multi stranded copper conductor cable ISI marked, drawn in and including PVC casing capping ( ISI marked) Heavy grade inclusive of junction/terminal boxes, all fittings and accessories fixed and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and multi stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified. Note :1 The cost of earth wire is included in the quoted rates. 2. Two run of 2.5 sqmm and one run of 1.5 Sqmm as applicable including PVC casing capping will be measured as one unit ie one running metre”
All as per item No. 61 above but 2 X 4 Sqmm inclusive 4 Sqmm earth wire. Note :1 The cost of earth wire is included in the quoted rates. 2. Two run of 4 sqmm and one run of 4 Sqmm as applicable including PVC casing capping will be measured as one unit ie one running metre”
All as per item No. 61 above but 2 X 6 Sqmm inclusive 6 Sqmm earth wire. Note :1 The cost of earth wire is included in the quoted rates. 2. Two run of 6 sqmm and one run of 6 Sqmm as applicable including PVC casing capping will be measured as one unit ie one running metre”
Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V, AC, recessed type (warm/milky white as required on site) with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling, life of tube light not less than 50,000 hours including connecting up with driver three core flexible copper conductor cable of suitable size complete. Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
Supply and fixing round shape 15 watt, 220 V, AC, recessed type (warm/milky white as required on site) with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling, life of tube light not less than 50,000 hours including connecting up with driver three core flexible copper conductor cable of suitable size complete. Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
S & F LED light fitting 1X10 W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make : Havells cat pat HEXAFT10WLED857SSYMBOPC or equivalent cat part in Make :- Phillips/Bajaj/C&S Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
Supply and fixing post top lantern LED type 20 Watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed .
Supply and fixing post top lantern LED type 40 Watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed .
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V, AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper cable of suitable size complete all as specified and directed .
Supply and fixing LED lights T-5 fitting 1x 20W (warm/milky white as required on site), 220V, AC with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose 1.5 RM and life of tube light not less than 50,000 hours complete all as specified and directed.. Note:- Contractor shall submit 2 year warrenty of LED light fittings from manufracturer alongwith purchase voucher.
M&L for taking down ceiling fans / wall mounted fans of any size / sweep after disconnecting the wire from existing ceiling rose and refixing the same after painting the same with synthetic enamel paint by spray machine including filter after cleaning dust, taking out burnt/damaged winding, bushes & cleanig of stator and rotor incl etc. Rewinding with 26/27 SWG of enamelled copper winding wire replacement of bearing /bushes, condencer 2.5/4 mfd handing and testing of fan with and including provision of 23/0.0076 copper flexible twin core not less than 1.5 meter in length and making the fan operational with a guarantee period of one year after installing, repair of fan complete all as specified and directed.
Material & Labour for taking out burnt/damaged winding, bushes & cleaning of stator and rotor incl etc of exhaust fans any sweep and size, Rewinding with 26/27 SWG of enamelled copper winding wire replacement of shaft, bearing /bushes, condencer 2.5/4 mfd handing and testing of fan with and including provision of 23/0.0076 copper flexible twin core not less than 1.5 meter in length complete all as specified and directed.
M&L for taking out burnt/damaged fan motor of Desert cooler and supply and fixing new fan motor with 26/27 SWG of enameled copper winding wire with bearing / bushes and including provision of 23/0.0076 copper flexible twin core not less than 3 meter in length with two pin top plug etc. and make the desert cooler in operational condition complete all as specified and directed. Comprising of the following works :- (i) Replacement of water pump including water pipe (Complete set). (ii) Replacement of Fan blade (PVC/Iron) as required on site. (iii) Replacement of desert cooler front grill (Fiber/Steel/Plastic as required) including switch, indicator and regulators. (iv) Checking & tightening the electrical connection (v) Replacement of wood wool (Grass Air cooler cooling pad) suitable of iron/Plastic body desert cooler (vi) Replacement of side grill (sets of 3) for holding wood wool/cooling pads. (vii) Replacement of fan condenser 3.15/4.0 mfd.
M&L for servicing of water heater (Geyser) upto 50 Ltr capacity of any make by cleaning sludge and slurry, calcium inside inner water storage tank and make the geyser in operational condition all as specified and directed by Engr-in-charge. Comprising of the following works :- (i) Rectifying water leakage in inner copper/iron storage tank by using welding (ii) Replacement of heating element upto 2000 Watt. (iii) Replacement of Thermostat of suitable size as required on site. (iv) Checking & tightening the electrical connection (v) Replacement of safety valve. (vi) Replacement of NRV (Non returning valve) of suitable size as required at site .
Supply and fixing solar heater tube including gasket suitable for fixing of Solar Water heater system (Executed tube collector based) on direct transferring of heat of capacity 250 to 500 LPD and make the system operational complete all as specified and directed.
S & F Exhaust fan mettalic body ISI mark, 300 mm size with blades, frame and louvers including cutting opening through brick/stone/PCC block wall, making of holes and grouting of suitable size of nut and bolts for 300 mm exhaust fan and making good dismantling portion and making connection with wire of suitable size and connected accessories complete all as specified and directed
S & F Exhaust fan made of sturdy Engineering plastic type ISI mark, copper winding of sweep 300 mm size complete with louvers including cutting opening through brick/stone/PCC block wall, making of holes and grouting of suitable size of nut and bolts for 300 mm exhaust fan and making good dismantling portion and making connection with wire of suitable size and connected accessories complete all as specified and directed
M&L for earthing complete with galvanized sheet earth plate electrodes 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of plat not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and including the earth test point of galvanized Iron/ steel of size 75x75x25mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering and connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost to Govt by the contractor.
Supply and fixing LED Security/Street light fittings 35 watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant inclding thermal management in multiple optics complete with IP 65/66 Protection with GI Pipe light grade bracket 1.2 mtr long 40 mm dia fixed to wall with suitable size 2 Nos MS Clamps including nuts, bolts and washers and making connection with using 1.5 sqmm pvc insulated multi standard copper conductor three single core complete all as specified and diredted.
Supply and fixing LED flood light 70 watt, 230 V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and average life of flood light not less than 50000 hours, including clamps, nut, bolts, fixing in wall including 2 sqmm PVC twin core aluminium cable from conductor to street light not less 2.0 metre , testing to satisfaction of Engineer in charge complete all as specified and directed.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230v, 10-60amp, accuracy class-I 50Hz, confirming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including suitable copper wire as requirement at site complete all as specified and directed. Note: Existing old meter will be deposited at MES store.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 3 phase, 415 Volts, 10-60amp, accuracy class-I 50Hz, confirming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including suitable copper wire as requirement at site complete all as specified and directed. Note: Existing old meter will be deposited at MES store.
Supply and fix Ceiling fans five star rating (white colour) complete with three blade, down rod, accessories 230 V, 1200 mm sweep, with squirrel cage induction motor with 1.5 sqmm suitable copper wire as requirement at site complete all as specified and directed.
M&L Servicing of indoor and outdoor unit of split type/ window AC of 1.5/2.0/3.0 ton capacity of any make by air blowing, cleaning the filter in water and drying in sun, cleaning of drain tray and rectifing water leak, checking and tightning the electrical connection incl provide insulation material on cooling coil and heating coil etc complete all as specified and directed
Supply and Refilling Gas/refrigerant (CFC free) in AC 1.5 ton / 2 Ton complete all as specified and directed
Supply and Refilling gas/refrigerant in Refrigerator having capacity 165 to 315 ltr complete all as specified and directed
Supply and Refilling Gas charging in Water cooler of capacity upto 60/120 Ltr complete all as specified and directed.
Supply, fixing in repairs and commissioning of Compressor for window, 1.5 ton capacity Air Conditioner (AC) complete all as specified and directed. Make:LG/Hitachi/GMCC/emerson.
Supply, fixing in repairs and commissioning of Compressor for Split AC, 1.5 ton Capacity complete all as specified and directed Make:LG/Hitachi/GMCC/emerson.
Supply, fixing in repairs and commissioning of Compressor Split and window, AC 2 ton complete all as specified and directed Make:LG/Hitachi/GMCC/emerson
Supply, fixing in repairs and commissioning Refrigerator compressor of capacity 165 to 180 ltr complete all as specified and directed
Supply, fixing in repairs and commissioning Refrigerator compressor of capacity 210 to 315 ltrs complete all as specified and directed
Supply, fixing in repairs and commissioning Water cooler compressor of capacity 40/80 ltr complete all as specified and directed
Supply, fixing in repairs and commissioning Water cooler compressor of capacity 60/120 ltr complete all as specified and directed
Supply, fixing in repairs and commissioning of relay for split and window AC upto capacity 2 Ton complete all as specified and directed
Supply, fixing in repairs and commissioning of relay for Refrigerator upto 315 Ltr capacity complete all as specified and directed
Supply, fixing in repairs and commissioning of PCB for split/window AC including inverter Split AC upto 2 ton capacity complete all as specified and directed
Supply and fixing in repairs Electronic control PCB for refrigerator upto 315 Ltr capacity all as specified and directed
Supply and fixing in repairs Thermostat of window/split AC of any capacity complete all as specified and directed
Supply and fixing in repairs Thermostat of Refrigerator any capacity complete all as specified and directed
Supply and fixing in repairs Thermostat of Water cooler of any capacity complete all as specified and directed
Supply and fixing in repairs blade with motor Split/window AC of capacity 1.5 TR to 2 TR complete all as specified and directed by Engr-in-charge.
Supply and fixing in repairs Fan motor Water cooler of capacity upto 60/120 Ltr complete all as specified and directed
Supply and fixing in repairs swing motor for split AC of any capacity complete all as specified and directed
Supply and fixing in repairs cooling coil for Window/Split AC for any capcity and size complete all as specified and directed
Supply and fixing in repairs heating coil/condenser coil for split/window AC 1.5 TR to 2 TR complete all as specified and directed
Supply and fixing in repairs Reverse valve of AC/Refrigerator/water cooler complete all as specified and directed
Supply, fixing in repairs and commissioning Condenser 50 mfd for Split/Window AC upto 2 Ton capacity complete all as specified and directed
Supply and fixing in repairs timer switch for refrigerator of any capacity complete all as specified and directed
Supply and fixing in repairs remote unit for split type AC of any model/size all as specified and directed
Supply and fixing in repairs Water cooler PVC pipe complete all as specified and directed
Supply and fixing in repairs Float valve 15 mm for water cooler 40 to 120 ltr capacity all as specified and directed
Supply and fixing in repairs Push tap for water cooler any size/capacity all as specified and directed
Supply and fixing Repair of voltage stabilizer of capacity 4/2/1 KVA, single phase, 230 V, AC, 50 Hz all as specified and directed
M/S BHATT ENTERPRISES
M/s RN Kharwar & Sons
AJA BUILDERS
M/S Gagan Khosla
Perfect Electricals and Engineers
ng associate
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .