Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹2.1 L+₹17,750 (9.33%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | shivalaycorporation L2 | Prakash Electricals L1 |
|---|---|---|---|---|---|
| 1.00 | Supplying and charging R-22/R-32/410 gas in the 1.5/2 ton window/Split type air conditioner units i/c leakage testing removing the leakage, pressure testing, flushing the complete system, vacuumising and gas charging complete as required. | 17 | Job | 5,000 ₹85,000 | 4,200 ₹71,400 Lowest |
| 2.00 | Supplying and replacement of following accessories in the existing 1.5TR/2TR split/window type AC unit i/c connection testing etc. as required. Starting/ Running Capacitor 45/6 MFD OR 50/6 MFD (Removed capacitor shall be retained by the contractor and suitably credited its value and net value to be quoted) | 3 | Each | 500 ₹1,500 Lowest | 750 ₹2,250 |
| 3.00 | Supplying and fixing of fan motor in the outdoor unit of 1.5/2 TR split units different makes i/c testing and commissioning etc. as required. (Removed fan motor shall be retained by the contractor and suitably credited its value and net value to be quoted) | 4 | Each | 2,000 ₹8,000 Lowest | 6,250 ₹25,000 |
| 4.00 | Dismantling and installation of 1.5/2.0 ton out door unit of split Air conditioner including dismantling/fixing of refrigerant copper tubes etc. complete as required. | 3 | Job | 3,000 ₹9,000 | 2,200 ₹6,600 Lowest |
| 5.00 | Supplying and fixing Brass copper Split type AC valve set for indoor and outdoor unit i/c joint nut, leak proof joints, testing and commissioning etc as reqd. | 4 | Each | 2,000 ₹8,000 | 900 ₹3,600 Lowest |
| 6.00 | Supplying and fixing of fan blade in the outdoor unit of 1.5/2 TR split units different makes i/c testing and commissioning etc. as required. (Removed fan blade shall be retained by the contractor and suitably credited its value and net value to be quoted). | 3 | Each | 1,500 ₹4,500 Lowest | 1,800 ₹5,400 |
| 7.00 | Replacement of PCB circuit Unit suitable for split air conditioners etc as required.(Removed PCB shall be retained by the contractor and suitably credited its value and net value to be quoted). | 10 | Each | 3,000 ₹30,000 Lowest | 5,800 ₹58,000 |
| 8.00 | Repairing and maintenance of PCB circuit Unit of split air conditioners i/c testing and commissioning etc. as required. | 4 | Each | 8,000 ₹32,000 | 3,000 ₹12,000 Lowest |
| 9.00 | Supplying and fixing refrigerant copper tubes suitable for 1.5/2 Ton Split type AC units from outdoor units to condensing units I/c cutting, bending, brazing, providing tubular foam thermal insulation, leak proof joints, suitable supports & saddles I/c testing commissioning etc as reqd. | 6 | Mtr | 5,000 ₹30,000 | 1,000 ₹6,000 Lowest |
Tender Value
₹1.9 L
EMD Value
₹3,810
Closing Date
18 Nov 2025, 11:00 amClosed
Assistant Engineer (elect)
FTR HQ BSF GUJ
Electrical annual repair maintenance of Air Conditioners at BSF campus Gandhinagar of FTR HQ BSF Gujarat
2025_BSF_885301_1
27/FTR-GUJ Elect/e-NIT/2025-26
Open Tender
Electrical Works
Item Rate
45 days
FTR HQ Gujarat
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹3,810
Yes
23 Feb 2026
12 Nov 2025
20 Nov 2025
12 Nov 2025
18 Nov 2025
12 Nov 2025
stage.html
html • 0.03 MB
techsummary_930547.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.41 MB
BOQ_930547.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .