Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC | L1 | Accepted-AOC Accepting being L1 | |
| 2 | L2₹34.0 L+₹1.5 L (4.59%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹36.2 L+₹3.7 L (11.5%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹38.8 L+₹6.3 L (19.3%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹39.7 L+₹7.2 L (22.1%)Rejected-Finance PLOT NO 361 FLAT NO 06 FIRST FLOOR SECTOR 11 HIRAN MAGRI UDAIPUR 313001 RAJ | UDAIPUR | UDAIPUR | RAJASTHAN | 313001 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
11 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY NO. 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
REPAIRS TO RCC ROOF CHAJJAS AND FACIA BALCONY AND MISC B R WORKS IN THE AREA OF AGE B R I ARMY UNDER GE ARMY NO 1 JODHPUR
2023_MES_627336_1
GE/JODH (A) NO 1- OF 2023-24 (9165/E8)
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY NO. 1
₹70,000
Yes
30 Jan 2024
8 Nov 2023
18 Dec 2023
8 Nov 2023
11 Dec 2023
22 Nov 2023
Amount
Demolition of reinforced cement concrete as in roof , floor (other than ground floor), beams, staircase, landing, chajja and other similar suspended work and including reinforcement cut on required to facilitate demolition and removing rubbish material outside the MD land complete all as specified and as directed.
M&L for RCC M-25 design mix as in slabs supported on walls, beams and colunms in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L TMT steel bars of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M&L TMT steel bars of 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including rough finished surfaces complete all as specified and directed.
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide includingrough finished surfaces complete all as specified and directed.
M&L FOR Exposing existing RCC members such as columns, slabs, lintels, beams, etc. up to the main reinforcement carefully by means of Chisel & hammer, hard wire brushes or any other mechanical means, so as to remove all loose concrete and cleaning the surface to remove all dust particles, etc. and make the surface ready for chemical treatment in bone dry condition.
Demolition of stone / boulder masonry walling, built in cement mortar including all quoins, arches, pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and directed.
M & L pre-cast cement concrete block masonry using PCC, 1:2:4, type B-1 solid blocks, not exceeding 10 cm in width and setting in cement mortar 1:4, straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed.
M&L for squared rubble walling jodhpur type, brought upto course,well bonded bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed.
All as per item No. 10.00 here-in-above, but except stone
M&L for 30 mm thick guniting in patches on to the required area on RCC/PCC columns, beams, stairs, lintels, retaining walls, sunshades, roofing slab etc. of all sizes and shapes at all heights from existing ground floor and all locations with cement and mortar 1:2 (1 cement : 2 sand) under 2 to 2.8 Kg/Cm2 pressure after removing the damaged loose spalt concrete portions by chipping, removal of dust and applying one coat of rust convertor/kp-100 OR equivalent grade over reinforcement wherever necessary providing and tying in position 25mmx25mmx12 gauge dia wire MS welded mesh or smaller size over treated surface ready to receive grouts, curing for 10 days etc,loose spalt concrete portions by chipping, removal of dust over treated surface ready to receive grouts including 5mm to 10mm thick plastering in CM 1:4 to match existing surfaces and finished even and smooth including curing for 10 days etc, complete operation all as directed including labour charges hire for all tools and plant machineries cost of consumables, scaffolding all types of protective equipments, plant floors, pipelines, vessels, materials etc. so as to do guniting in plant, removing the debris out of MOD land in low lying areas and leveling as directed, incl two coat of white wash over one coat of primer complete all as directed by Engr-in-charge.
All as per item No. 12.00 here-in-above, but thickness is 50 mm,
Note FOR ITEM NO. 12 &13:- (i) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with brushes, washed with water and alloy to dry. To this surface apply chemistic polycrete admixture at the rate not less than 2% by weight of cement or as per manufacture’s instructions. (ii) When polymix coating is in tackey condition guniting is done with polycrete admixture at the rate not less than 2% by weight of cement or as per manufacturer’s instruction. Polycrete admixture shall be procured from Chemical Adhesive Pvt Ltd Co or their authorized dealer. (iii) Cost of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
M & L pre-cast cement concrete block masonry using PCC, 1:2:4, type B-1 solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6, straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed.
Extra over for hammer dressing to face stones with maximum depression on face from a straight edge not exc 20mm and dressing face beds and joints as specified to squared rubble walling,Jodhpur type, brought upto courses all as specified and as directed.
Taking down cement plaster any description on brick/pcc or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified and as directed.
M&L 15 mm thick rendering in CM 1:6 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface even and smooth without using extra cement, complete all as specified and as directed.
M&L 15 mm thick rendering in cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing mixed with water proofing compound as per manufacturer instructions and finished the surfaces even and smooth with out using extra cement complete all as specified and as directed. Note :- WPC will be measured and paid seperately.
M&L for 10 mm thick Rendering in CM 1:3 on fair faces of brick work or conc surfaces as in ceilings/chajja/facia & finished even & smooth w/o using extra cement, complete all as specified and as directed.
S&F GI wire netting 0.90mm dia and 12mm mesh size lathing to wood or metal studding, joist etc in wall, ceiling stanchions beams etc including all laps,cutting and waste complete all as directed
M&L for Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash on ceiling surfaces complete all as specified and as directed.
M&L for preparation of old decorated wall surfaces plastered or unplastered, by brooming down or steel wire brushing, scrapping down moulds, moss and efflorescent salts and trading oil & greasy spots, including cornices etc and applying two coat of white wash on wall, complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces of walls and applying two coats of cement base paint over & including M&L one coat of alkali resitant primer, complete all as specified and as directed.
Preparing new plastered or unplastered surfaces and applying with 2 coats wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper over & including M&L of one coat of alkali resitant primer on walls complete all as specified and as directed.
M&L for preparation of old decorated wall surfaces plastered or unplastered, including cornices pilasters by brooming down or steel wire brushing and efforescent salts and applying one coat of distemper oil emulsion on wall, complete all as specified and directed.
Racking out joints/ pointing to squared rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar or cement lime mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed.
M&L keyed pointing in cement mortar (1:3) to squared rubble masonry regular coursed or un coursed complete all as specified & directed.
M&L for preparation of old decorated wall surfaces plastered or unplastered, by brooming down or steel wire brushing, scrapping down moulds, moss and efflorescent salts and trading oil & greasy spots, including cornices etc and applying one coat of colour wash on wall, complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces of walls and applying two coats of colour wash complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
M&L Plain cement concrete 1:4:8 type D-2 by using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed .
M&L 50 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate laid in alternative bays as in plinth protection including finishing the surface even & fair & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight in 2 mtr interval, complete all as specified and directed.
M&L 50 mm thick plain cement concrete, 1:2:4 type B0 using 12.5mm graded stone aggreage, as in coved fillets of radius provided at junction of roof and parapet / vertical surfaces, padding concrete to achieve slope as required , platform for water tank on roof slab etc., including necessary form work complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coat of synthetic enamel paint over & including M&L single coat of red oxide primer complete all as specified and as directed.
M & L for preparation of old painted steel surfaces of any description otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint of any tint complete all as specified and as directed .
M&L mild steel work as in door frame and similar work fixed with angle cleates, confirming to Fe 410 Grade E - 250 Quality A, complete all as specified and as directed.
M&L for framed brackets for cooler stand as shown in Drg No CEJZ/TD/72/2015 sheet1/1 of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') and also used in chajja stand/ steps/stairs, complete all as specified and as directed.
Complete removal of folliage/vegitation growth on building and in over accessible/ non accessible roof ,chajjas. Wall and simillar surfaces etc. and making good the surfaces, area of each job not exceeding 1.00 Sqm and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed. (Note:- Appx height of the buildings 7.00Mtrs)
Repair to steel window including taking down, replacement of unserviceable hinging device box type, handles, making them in serviceable condition and re-fixing in same opening including making good soffits and jambs in CM 1:4 complete all as directed.
Demolition of cement concrete as removing existing roof treatment and preparing surfaces to the entire satisfaction of Engr-in Charge /GE including taking down existing plaster, padding,cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc . flushing at junction of parapets complete and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
M&L for plain cement concrete 1:2:4, type B-0 (using 12.50mm graded crushed stone aggregate), as in roof padding over roof for making good depression / undulation to make the existing as filling in depression of roof slab, complete all as specified & directed.
M&L plain cement concrete (1:2:4) type B-1using 20mm graded crushed stone aggregate as in roof kerbs or mud steps, weathering, rounded or chamfered on edge, fixing of holdfast etc complete all as specified & directed
Supply only Integral water proofing compund ISI Marked, completed all as specified.
Cutting out existing cracks in 'V' sction 6 mm and 10mm gap in existing roof our terrace, cleaning and filling solidly with a hot mixure of bitumen and clean dry sand in ratio (1:1 by weight) complete all as specified and directed
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid dry or laid dry and pointed complete all as specified and directed.
M&L for 35 to 40mm thick sand stone slabs as in chajjas n.exc 2m in lengthmachine cut on face and along exposed edges ,self faced on other side and set and pointed in cm 1:4 complete all as specified and directed.
M&L for Jodhpur stone roof slabs self faced 7.5cm to 10cm thick, 25cm to 35cm wide ,hoisted and set jointed and grouted in cm 1:3, complete all as specified and directed
Meterial and labour for rolled section as in sun shed main cross beams hip and jack rafters purlins, chajja etc where connected to common rafters and running rails and guides for sliding doors fixed with angles cleats or other connecting plates FE 410-0 or Fe 210-0 as per directed.
Disconnecting of old serviceable PVC tank (upto 500 Ltr cap) setting aside (or lowering if required) including repair cleaning etc and hoisted in same location including reconnection and refixing for proper functioning of over head tank complete all as directed.
Disconnecting of old serviceable PVC tank (exceeding 500 ltr cap) setting aside (or lowering if required) including repair cleaning etc and hoisted in same location including reconnection and refixing for proper functioning of over head tank complete all as directed.
S & F in PVC water tank lead cover 500 ltrs/1000 ltrs fixed with screw ,GI wire with sutable arrangement complete all as directed.
S & F in repair 20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Demolition of reinforced cement concrete of any description for Chajja , railing, ladder , facia , manhole cover, colums , self slab of type, other places etc complete all as specified and directed.
S&F mild steel frame work as in stairs ,hand rails half round or other stock section or section or core for wooden hand rail straidgt portion drilled and countershunk for balusters running bars for doors balusters nosing to steps including embeded in concrete and screwing etc hid ties for foof including securing bolts post and struts in fencing including securing bolts post and struts in fencing including cutting tops to shape as directed drilling holes nothing for wire etc flat iron fillet for necessary drilling boltinh or riveting etc and similar work confirming to Fe 410-0 or fe 310-0, complete all as specified and directed.
Dismantling structural steel work including doors, gates etc complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and directed.
All as per item No 56.00 here-in-above, but size of pipe 15 mm bore.
Refixing old GI water tubing of 20 mm bore, medium grade including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
All as per item No 58.00 here-in-above, but size of pipe 15 mm bore including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc., complete all as specified and as directed.
S&F of 20 mm bore GI steel tubing medium grade, galvanized, with all fittings fixed to wall, ceilings or laid n floors, complete all as specified and as directed.
All as per item No 60.00 here-in-above, but size of pipe 15 mm bore including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc., complete all as specified and as directed.
M& L for precast cement concrete Type B-0 1:2:4 (12.50mm graded aggregate) as in louvres and jallies, cement grill any type model of Zafri 25/40mm thick (measured solid), set in cement mortar 1:4 fixed with PCC post, incld. all mouldings complete all as specified and directed.
M&L for neat cement slurry @ 3.00 kg/Sqm and screeding / bedding layer of 10 mm thick in CM 1:3 mixed with water proofing compound as per manufacturer instructions over the RCC roof slab for laying of water proofing treatment including providing the following as roof treatment complete all as specified and as directed : - (a) FIRST COURSE: Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastered surfaces. (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 100mm micron HMHDPE, outer film 20 micron each, thickness 3.00mm having weight not less than 3.00 Kg/Sqm, mineral gravel finish on top, using torch application method with minimum 10cm side lap and 15cm end lap complete . (d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen conforming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm. (e) FIFTH COURSE : 40 mm thick plain cement concrete 1:2:4 (using 20 mm stone crushed aggregate) as in roof padding, including WPC as per manufacturer instruction. NOTE :- 1. A Information Tablet will be put up in the front side wall of the buildings where this work will be done. All building/structure shall be provided with plaque (tablet) furnishing the information as per PS clause, in plaster engraving in and painted as directed by GE 2.WPC shall be measured and paid separately under respective item.
RV. Enterprises
M/S KAUTILYA GARG
M/s Chawariya Enterprises
M/s Ajay kumar Garge
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .