Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
REPAIR/ MAINTENANCE OF FIRE ALARM SYSTEM, MAIN PANEL ALONGWITH ITS ALLIED ACCESSORIES AT INS KALINGA, INS KARNA AND NAD BHEEMUNIPATNAM UNDER GE (P) NAVY KALINGA
2023_MES_604224_1
GE (P)/N/K/8041/23-24 OF 2023-24
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class E, Category c(vi)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹46,000
Yes
30 Mar 2024
19 Jun 2023
19 Jul 2023
19 Jun 2023
17 Jul 2023
3 Jul 2023
Amount
Supply and fixing in repair of micro processed based master control board with suitable for analogue addressable fire alarm control panel with standards NFPA 72 UL 864 listed, which can accommodate 4 loop cards class A or B , each loop card can operate upto 200 detectors with loop resistance 40 ohms and loop current of 300 mA Board should consists of a) RS 485 communication port and USB 2.0 port b) 3 x programmable relay c) Power Limited Conventional Zone Circuit Class B Style C input d) 24V DC output e) 24v NAC 1 & 2 Outputs f) 4 x loop card terminals g) Display output pin with h) Power supply input 12 pin on board female connector
Supply and fixing in repair of Display unit with 40 x 4 character LCD and touch keypad suitable for analogue addressable fire alarm control panel With control and indications a) Common indicators b) Zone Group indications c) Alphanumeric key pad d) Control keys e) Piezo buzzer f) 40 x 4 character LCD display g) Input pin
Supply and fixing in repair of Power supply unit for addressable fire alarm control panel with battery charging unit with 12 pin output (multiple voltage outputs, grounds etc) primary source 120/220 AC power supply and secondary source 24 V DC (battery source) all as specified and directed by Engr-in-charge.
Supply and fixing in repair of micro processed based master control board with suitable for 4 zone conventional fire alarm control panel with standards NFPA 72 UL listed loop card can operate upto 30 detectors per zone, Board should consists of a) RS 485 communication port and USB 2.0 port b) 4 zone input ports c) Power Limited Conventional Zone Circuit Class B Style C input d) 24V DC output e) 24v NAC 1 & 2 Outputs f) Fire relay NO NC C supervisory ports g) Fault relay h) Piezo buzzer i) Display output 24 pin j) Power supply input 2 pin on board female connector
Supply and fixing in repair of Display unit with 16 x 2 character LCD and touch keypad suitable for 4 zone conventional fire alarm control panel With control and indications a) Common indicators b) Zone Group indications c) key pad d) Control keys e) Piezo buzzer f) 16 x 2 character LCD display g) Input pin Make- Honeywell/Simplex/Ravel/Morley
Supply and fixing in repair of Power supply unit for 4 zone conventional fire alarm control panel with battery charging unit with 2 pin 24 v DC output(multiple voltage outputs, grounds etc)primary source 120/220 AC power supply and secondary source 24 V DC ( battery source)
Supply and fixing in repair of micro processor based master control board with suitable for 8 zone conventional fire alarm control panel with standards NFPA 72 UL listed loop card can operate upto 30 detectors per zone, Board should consists of a) RS 485 communication port and USB 2.0 port b) 8 zone input ports c) Power Limited Conventional Zone Circuit Class B Style C input d) 24V DC output e) 24v NAC 1 & 2 Outputs f) Fire relay NO NC C supervisory ports g) Fault relay h) Piezo buzzer i) Display output 24 pin j) Power supply input 2 pin on board female connector
Supply and fixing in repair of Display unit with 16 x 2 character LCD and touch keypad suitable for 8 zone conventional fire alarm control panel With control and indications a) Common indicators b) Zone Group indications c) key pad d) Control keys e) Piezo buzzer f) 16 x 2 character LCD display g) Input pin
Supply and fixing in repair of Power supply unit for 8 zone conventional fire alarm control panel with battery charging unit with 2 pin 24 v DC output(multiple voltage outputs, grounds etc)primary source 120/220 AC power supply and secondary source 24 V DC ( battery source) all as specified and directed by Engr-in-charge.
Supply, fixing and replacement of UL Listed Analogue addressable smoke cum heat multi detector with 8 digit dip switches address settings, Dual LED indication for 360 degree visibility, shall be polarity insensitive, Insect filter chamber, advanced detection and communication protocol. Operation voltage : 17-28V DC all as specified and directed by Engr-in-charge.
Supply, fixing and replacement of UL Listed Conventional smoke cum heat multi detector with, Dual LED indication for 360 degree visibility, shall be polarity insensitive, Insect filter chamber, easy to install, advanced detection and communication protocol. Operation voltage : 9-33V DC all as specified and directed by Engr-in-charge.
Supply, fixing and replacement of Manual Pull Station is made up of a high quality PVC housing with breakable glass and resettable switch inbuilt operating with 24 V DC power supply and 30 mA operating current suitable for and conventional fire alarm control panel all as specified and directed by Engr-in-charge.
Supply, fixing and replacement of addressable Manual Pull Station is made up of a high quality PVC housing with breakable glass inbuilt 8 way dip switch for addressing and resettable switch inbuilt operating with 24 V DC power supply and 30 mA operating current suitable for addressable fire alarm control panel all as specified and directed by Engr-in-charge.
Supply, fixing and replacement of Sounder / Horn cum strobe are with both audio and visual indication in case of fire and emergency. The horns. Horn output dB level between 80 to 100 db in a meter distance complies NFPA 72 standards with operating voltage 18 to 30V ( 24 v nominal DC) with current less than 100mA built with FR ABS plastic IP 40 Rated all as specified and directed by Engr-in-charge.
Supply, fixing and replacement of 2 x 12v 7ah lead acid batteries for secondary power supply backup for fire alarm control panel all as specified and directed by Engr-in-charge.
Supply, laying, testing, saddling and glanding termination of 2 core , 2.50 sqmm twisted pair armoured cable copper conductor, including removing unserviceable old cable complete all as specified and as directed for external usage all as specified and directed by Engr-in-charge. Make- Havells/Gloster Cables/KEI/Polycab
Supply, laying and testing FRLS flexible copper cable 1100 Volts grade of size 2 core, 1.50 sq mm complete all as specified for internal usage
Supply and fixing in repair of micro processor based master fire alarm control panel analogue addressable fire alarm control panel with standard NFPA UL 864 listed, which can accommodate 4 loop cards class A or B, each loop card can operate upto 250 detectors with loop resistance 40 Ohms and loop current of 30 mA, with all features like RS 485, 3 programmable relay, support port for class B style input devices with networkable ability the above price include 1 loop card and two batteries, installations, commissioning and networking with main integration network all as directed by Engineer-in-Charge
M&L for Repair replacement of analogue addressable control module to control 24 volt operational devices all as specified and directed by Engr-in-charge.
M&L for Repair and replacement of loop card of 250 addressable devices can fitted with existing analogue addressable fire alarm control panel with programmable as class A, Class B wiring with dual LED indicators for knowing the status of the loop card all as specified and directed by Engineer-in-Charge
Supply and fixing in repair of micro processor based 4 Zone conventional fie alarm control panel with standard NFPA 72 can operate up to 30 detectors per Zone, Board should consist of RS 485, 2 Programmable relay, support port for class B style input devices with networkable ability the above price includes two batteries, installations, commissioning and networking with main integration network all as specified and directed by Engineer-in-Charge
Supply and fixing of micro processor based 8 Zone conventional fire alarm control panel with standards NFPA 72 can operate upto 30 Detectors per Zone, Board should consist of RS 485, 2 programmable relay, support port for class B style input devices with networkable ability the above price includes two batteries, installations, commissioning and networking with main integration network all as specified and directed by Engineer-in-Charge
M&L for Inspection, testing, supervision of existing fire alarm panels, networking fire alarm panels, fire alarm repeater panels of individual fire alarm panels. Note : (i) Inspection to be carried out for all the accessories attached to the fire alarm panels. (ii) Accessories testing should be carried for detectors, MCP, Hooters etc. (iii) Quoted rate for one job includes the charges for testing all the systems existing inside INS Kalinga, NAD Bheemunipatnam and Karna (Approx. active system - 45 Nos).
M&L for carrying out and attending complaints on regular basis to rectify complaint, lodged at Engg dept./Regular tests/complaint cell, rectify complaint and making necessary arrangements to prevent from further complaints, keep the system in working conditions including carrying out the following :- a) Clearing of faulty detectors b) Cleaning of MCPs c) Cleaning of Hooters d) Cleaning of control modules Note : Spares and accessories if required are to be arranged by the contractor at his own cost and the quoted rate is deemed to be included for the same.
Fixing or shifting or reinstalling old working Fire Alarm control panel and connected accessories like smoke detectors, hooters, manual call points, power supply wiring, networking FADS network system designated magazine on any location directed by Engineer in charge. Note : Quoted prices deemed to be inclusive of complete wiring for detectors and all accessories mentioned above complete all as directed by Engineer -in-Charge
SHIKHARA PROJECTS
newton electro technics
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .