| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.8 LAccepted-AOC HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | ₹75.8 L Quoted ₹77.3 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹81.3 LRejected-Finance | ₹81.3 L | L2 | Rejected-Finance Other then lowest bidder |
| 3 | L3₹88.1 LRejected-Finance G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA GUJARAT 390002 | VADODARA | VADODARA | GUJARAT | 390002 | ₹88.1 L | L3 | Rejected-Finance Other then lowest bidder |
| Sl No | Description | Qty | Unit | Harsh Infrastructure L1 | City Light L3 | UMA CONSTRUCTION L2 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified | 10 | Cum | 300 ₹3,000 | 250 ₹2,500 | 1,500 ₹15,000 |
| 2.00 | Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but exceeding ashlar facings, dressed stonework and precast concrete articles complete all as specified and dircted by engr -in-charge. | 375 | Cum | 250 ₹93,750 | 250 ₹93,750 | 75 ₹28,125 |
| 3.00 | Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed . | 420 | Cum | 150 ₹63,000 | 250 ₹1.1 L | 150 ₹63,000 |
| 4.00 | All as per item No 03 here in before but each additional 1.5 m or part thereof in depth beyond the first 1.5 m as directed | 135 | Cum | 200 ₹27,000 | 250 ₹33,750 | 125 ₹16,875 |
| 5.00 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed | 140 | Cum | 850 ₹1.2 L | 2,000 ₹2.8 L | 1,200 ₹1.7 L |
| 6.00 | M&L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete including necessary form work complete all as specified and directed. | 30 | Cum | 5,600 ₹1.7 L | 6,500 ₹1.9 L | 4,500 ₹1.4 L |
| 7.00 | M&L for RCC design mix M-25 (using 20 mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, etc. complete all as specified and as directed | 130 | Cum | 7,800 ₹10.1 L | 9,000 ₹11.7 L | 7,800 ₹10.1 L |
| 8.00 | M&L for RCC design mix M-25 (using 20 mm graded aggregate)as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of
footings; including attached pilaster and buttresses etc. complete all as specified and as directed | 145 | Cum | 7,800 ₹11.3 L | 9,000 ₹13.1 L | 8,000 ₹11.6 L |
| 9.00 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in flat rough finished surfaces of concrete. | 60 | Sqm | 400 ₹24,000 | 350 ₹21,000 | 350 ₹21,000 |
| 10.00 | M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter in flat rough finished surfaces of concrete all as specified and as directed | 850 | Sqm | 450 ₹3.8 L | 350 ₹3.0 L | 350 ₹3.0 L |
Updated dates
Tender Value
₹87.5 L
EMD Value
₹1.4 L
Closing Date
20 Dec 2025, 6:00 pmClosed
Col Manish Dhaka CWE
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
ADDN ALTN IMPROVEMENT TO CERTAIN WORKS AND APPROCH ROAD AT MAKARPURA AT AF STN VADODARA
2025_MES_731951_1
82276/BRD/E8
Open Tender
Civil Works
180 days
Baroda
As per tender document
7 documents required · 7 mandatory
₹1,000
GE (AF) Baroda
₹1.4 L
6 Feb 2026
20 Sept 2025
29 Dec 2025
20 Sept 2025
20 Dec 2025
6 Dec 2025
20 Sept 2025 - 10 Oct 2025
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified
Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but exceeding ashlar facings, dressed stonework and precast concrete articles complete all as specified and dircted by engr -in-charge.
Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed .
All as per item No 03 here in before but each additional 1.5 m or part thereof in depth beyond the first 1.5 m as directed
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed
M&L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete including necessary form work complete all as specified and directed.
M&L for RCC design mix M-25 (using 20 mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, etc. complete all as specified and as directed
M&L for RCC design mix M-25 (using 20 mm graded aggregate)as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses etc. complete all as specified and as directed
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in flat rough finished surfaces of concrete.
M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter in flat rough finished surfaces of concrete all as specified and as directed
M&L for TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia. complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed
Removing excavated material (all kind of soil) exc 1.5 KM and n.exc 5.0 Km depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed
S & F 110 MM dia PVC (SWR) pipes single socketed, in any length laid in brick/ pcc block masonary as in weep holes including laying filter media to the earth fill side all as specified and as directed.
M&L for brick work with sub class B brick straight or curved on plan exc. 6 M mean radius built in cement mortar 1:6 complete all as specified and dircted by engr -in-charge.
M&L for rendering in two layers (i.e) CM 1:6, 10mm thick as first layer and CM 1:4, 5mm thick as 2nd layer with and including recron fibres with the proportion as per manufacturer / Eng-in-Charge alongwith chicken wire mesh on stone/brick masonry surfaces or surfaces other than fair face of brick or on concrete surfaces finished even and smooth without using extra cement complete all as specified
M&L for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified.
M&L for Preparation for new surfaces on wall/concrete surfaces and apply two coats of cement base paint camuflage pattern, colour as approved by GE complete all as specified and directed by Engineer-in-Charge. Make - Snowcemplus/Super acrocem including necessary form work upto 4th floor.
M&L for cement concete type B-1,1:2:4 mix (using 20 mm graded stone aggregate) as in copings of parapet wall including necessary form work complete all as specified and directed.
M&L for Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregates) as in 75 mm thick plinth protection , finished surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L for prepration on the existing surfaces on wall/concrete surfaces throughly, washing rubbing down in the water, cleaning upto the entire satisfaction of the Engineer-in-Charge and apply one coat of cement base paint camuflage pattern, colour as approved by GE complete all as specified and directed by Engineer-in-Charge.
M&L for Spreading and leveling of fine good sand free from stone / pebbles, mixed with wood saw dust powder in equal proportion (obtained from outside MOD) including removing existing sand complete all as specified and directed
M&L for Shingle filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled, and blinded with earth and rammed including watering and removal of existing shingle from site complete all as specified and directed
S&F for Framed work such as grills, gratings, etc (for bullet proof iron sheet). with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
Taking down chowkats or frames (without taking of shutter from the frame) not exc. 1.5 Sqm each complete all as specified and dircted by engr -in-charge
Taking down shutters of any description n exc 1 sqm each and removing from site under sch of credit complete all as specified and directed
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each and removing from site under sch of credit complete all as specified and directed
S&F in repair solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, all as per specifications & drawings and as directed by Eng-in-Charge complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawingspecification and drawing complete all as specified and directed.
S&F 35 mm thick flush doors, solid core with prelaminated exterior grade with both side decorative choice lamination with lipping/frame to match incl. all necessary fittings etc complete all as specified and as directed by the Engineer -in-charge.
S&F 2nd class hard wood 30mm glazed and skeleton shutter for windows and ventilator etc, open rebated and prepared to receive glass, gauze etc (with vertical sash bars), edges of framing plain, chamfered or rounded,fitted with cut and retired beads for securing glass etc size of membrane of shutter as specified in SSR part I, Section 8, clause 8.24 (b) and fitted to chowkats.
S&F in repair 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete All as specified and as directed
S&F in repair 12mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work such as door shutters etc
S&F 100mm size butt hinges medium weight cold rolled mild steel and fixed (ISI Marked) complete all as specified and directed by engr -in-charge
S&F (in repair) continuous piano hinges mild steel bright finish or electrogalvanised width of flap 30mm complete all as specified and directed
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor over all length 150mm complete All as specified and as directed by Engg-in-charge
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete All as specified and as directed by Engg-in-charge
S&F 200 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by engr -in-charge
S&F 150mm long aluminium handles, cast type, anodised complete all as specified and directed
S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with wooden beadings complete all as specified complete all as specified and directed
S&F in repair bib cock with wall flange,cast copper alloy, fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm dia of pipe complete all as specified and directed by engr -in-charge
S&F in repair Angular stop cock with adjustable wall flange, cast coper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions, and fixed for bore 15mm bore of pipe complete all as specified and directed by engr -in-charge.
S&F in repair Vitreous China wash basin, white, flat back, size 580x450mm (for Hospilal use) including cutting for and pinning in ends of brackets or erecting stand complete all as specified
S&F in repair pillar taps, fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shank and fly-nut, screws for iron pipe and fixed for 15mm dia of pipe complete all as specified and directed by engr -in-charge
S&F in repair PVC connection 15mm dia with PTMT nut of length 450mm long complete all as specified and directed
Supply & fixing in repair PVC valve less Symphonic action type flushing cistern, 10 Litre Capacity,white with inlet,ball valve, float and handle incl bracket complete all as specified and as directed by engr -in-charge
S & F in Repair Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern incl fixing with fushing cistern complete all as specified and as directed by engr -in-charge
S&F in repair grating doom 100mm dia of PTMT (Minimum weight 25 gms) complete all as specified and directed by engr -in-charge
S & F in repair Ball valves 25 mm bore high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball screwed for iron pipe & fixed.(Minimum weight 25mm-455gms ) complete all as specified and directed by engr -in-charge
S & F in repair Nipple suitable for HDPE water tank 25 mm bore . (minimum weight 25mm-65gms) complete all as specified and directed by engr -in-charge
S & F in repair 25 mm bore Gun-metal, glabe or gate valves, with iron wheel head, screwed both ends for iron pipe & fixed complete all as specified and as directed by engr -in-charge
S & F in repair 20 mm bore Gun-metal, glabe or gate valves, with iron wheel head, screwed both ends for iron pipe & fixed complete all as specified and as directed by engr -in-charge
S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws in the wall complete all as specified and directed by engr-in charge.
S&F in repair Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Eng-in-Charge.
S&F in repair health faucet of approved quality complete All as specified and as directed b Eng-in-Charge.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (including fixing bolts, and flush pipe) complete All as specified and as directed by Engg-in-charge
S&F in repair 32mm dia Brass chromium plated bottle trap for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed
S&F Rotational moulded polyethylene water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including Dismantling water tanks and removing to store complete all as specified and directed by engr -in-charge
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15mm thick screed bed in CM 1:4 complete all as specified and as directed by Eng-in-Charge..
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with over and including 10mm thick screed bed in CM 1:4 complete all as specified and as directed by Eng-in-Charge..
M&L for Grinding and mirror polishing of old surface of kota stone and matching with existing or new surface complete all as specified and as directed by Eng-in-Charge.
Material & labour for 25mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in laying of floor, surface finished even and smooth with out using extra cement complete all as specified and directed
M&L for Excavation of post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed by Engr- in- Charge.
M&L for Plain Cement concrete type C-2 1:3:6 (using 40mm stone aggregate) as in post holes even and smooth without using extra cement complete all as specified and dircted by engr -in-charge
M&L for round bars 10mm dia (FE-290 and gde-165) and over cut to length bent to shape required incl cranking, bending spirally for hoping for colums, or ren work, hooping ends and binding with and incl mild steel wire annealed, not less than 0.9mm dia complete all as specified and directed
M&L for Mild Steel for Posts and struts in fencing including cutting top to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc)including all necessory drilling, bolting or riveting etc., and confirming to Fe-290 Gde E-165 complete all as specified and as directed by Engr- in- Charge.
S&F Mild steel screw bolts of dia 5mm to 10mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed by Engr- in- Charge.
Dismantling fencing wire mesh, any type
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire
Supply only Chain link MS galvanisd fencing, any size or type
M&L for preparation of new painted surfaces of steel and iron surfaces over 10cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil.
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with gray cement and no pigment (as in road berm), complete all as specified and as directed by Engr-in-Charge.
M & L for 100mm thick plain cement concrete 1:4:8 type D 2 using 40 mm .graded aggregate as in sub base to receive floor finishes complete all as specified and directed by engr-in charge.
M&L for sand cushioning under the interlocking tiles complete all as specified and as directed.
Taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling rosees, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable (FRLSH)1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including modular metal flush box made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of modular white cover plate over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for following:- Note :- Switch, socket and fan regulators to be measured and paid for separately .
One light/Fan/Exhaust fan point controlled by one switch
Socket outlet point 5 Amp on same board.
Socket outlet point 5 Amp on Independent board.
Description all as per serial item No. 82 above but with 2.5 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) complete all as specified.
Supplying & fixing modular switch, single pole one way 6 Amps, 230 volts AC circuit complete all as specified & directed by Engineer-in-Charge
Supplying & fixing modular switch, single pole one way 16 Amps, 230 volts AC circuit complete all as specified & directed by Engineer-in-Charge.
Supplying & fixing modular socket outlet, 6Amps, 5 pin, 230 volts AC circuit complete all as specified & directed by Engineer-in-Charge.
Supplying & fix modular socket outlet, 6-16Amps, 3 pin, 230 volts AC circuit complete all as specified & directed by Engineer-in-Charge
Supply & fix in repair Fan Regulator 5 step Modular type 240 Volts.
Supply and fix ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
Supply and fix indoor decorative channel housing fitting slim LED batten 20 Watt with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable from ceiling rose to connector of the light, fixing the same with two Nos PVC square box complete including taking down old unserviceable all as per specified and directed.
S & F in repair MCB DB 8 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair MCB, single pole and neutral link (double pole) 240 volts 40 to 63 Amps capacity B series fixed in DB's.
Supply and fix in repair MCB, single pole 240 volts 6 to 32 Amps capacity B series fixed in DB's.
M&L for Galvanised iron wire 4 mm dia buried in ground or on wall complete all as directed.
Taking down & refixing of existing Ceiling fan/Exhaust fan after painting with synthetic enamel paint including suitable wire complete all as specified and directed by Engr-in-Charge.
M & L for sub main wiring using 2 run single core 4 sqmm FRLSH PVC insulated and unsheathed cable with copper conductor 1100 Volt grade ISI mark drawn in and including concealed PVC Coduit with accessories like bend, Tee, etc fixed on wall and ceiling and connecting to earth dolly and including 4 sqmm earth wire PVC insulated and unsheathed copper conductor FRLSH all as directed by Engr-in-Charge :- Note : Three run of wire 1 run of PVC conduit shall be measured as one unit.
Supply and fix LED security light luminaire 36 watt freedom , pressure die cast aluminum housing, heat resistant glass, IP66 protection, better optics for uniform distribtion complete with all fitting accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete
Supply and fix bracket for security light made up of 25mm dia,1.60m long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
Supply, installation and commissioning of Earthing complete with galvanised steel Earth plate electrode, 60x60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not lesss than 1.5 meters below normal ground level ,connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 3 of SSR Part-I. Connected to earthing test point all as specified and including necessary testing on completion including M&L for cement concrete chamber and RCC cover of size 300x300x50 mm (1:2:4) type B1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as specified and directed by Engr-in-Charge .
Supply and lay in repair and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with standerd aluminum conductor, 1100 Volts grade, of size 70 Sqmm 3.5 Core complete all as specified and directed by by Engr-in-Charge.
Supply and lay in repair and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with standerd aluminum conductor, 1100 Volts grade, of size 25 Sqmm 3.5 Core all as speicified and as directed by Engr-in-Charge
Supply and Installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type confirming to IS 2713 complete include 2 coats of aluminium paint over one coat of red oxide primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole including M & L for 5 nos synthetic enemelled paint bends (in skyblue and white colour ) of 30 cm each for 410 SP -44 (11 m long) complete all as specified and directed.
Supply & fix LED flood light 300 watt capacity fixed on pole with fixing arrangement complete all as specified and directed
S&F aesthetically designed LED Street light luminiareis of 80 Watts system wattage for energy saving having IP 66 degree of protection, with minimum system efficiency as>85%, made of pressure die casting aluminum housing powder coated in graphite grey and heat resistant toughened glass with excellent thermal management LED should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120-270V AC, THD<10%, P.F>.95 The fitting should have in built surge protector of 10 KV and CRI>70 with CCT 5700 K complete all as specified and directed
S & F GI pipe bracket for street light 1200mm long made out of 40 mm dia GI pipe light grade suitable for fixed on top with cap of pole complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32x6 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel, besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 50 mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanised Iron/steel, including M&L for cement concrete chamber and RCC cover of size 300x300x50mm (1:2:4) type B1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as specified and directed.
(i) The excess requirement (if more than 7.5Mtr for each earthing ) of GI strip and their joints for connecting upto the test point will be measured and paid separately.
(ii) The excavation & earth work will be deemed to be included in the item rate.
Supply and fixing LED Aviation Light Luminaires 240 V IP 65 Die-cast aluminum housing with Red polycarbonate dome for better illumination Integral driver. Protection against short-circuit Protection against surge complete with fixing arrengement(2mtr standing rod on wall with 40 mm dia)
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core all as specified.
Supply and fix in repair MCCB four pole 100/125 Amps 415 Volts breaking capacity 30 KA as per IEC 60947-2 all as directed by Eng-in-Charge.
M & L for Street light control wire from junction box to street light using two single core 1.5 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in pole hollow portion including 1.5 Sqmm earth wire, PVC insulated & unsheathed all as directed by Eng-in-Charge. Note :- Two run of main wire and one run of earth wire shall be measured as one unit..
Excavation in trenches not exceeding 1.5 m wide and not exeeding 1.5 m in depth and getting out in soft/loose soil for removing/laying of cable etc as directed by Engineer-In-Charge.
Returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each all as directed by Engineer-In-Charge.
Removing surplus excavated soil to a distance not exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
M & L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable all as specified. Note : Punning thickness of sand only shall be measured.
Supply and lay burnt bricks sub class B for cable protection laid across the length of cable all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:3:6) type C-2 (using 40 mm graded black trap/granite/basalt stone aggregate) for coping of the pole including necessary form work complete all as specified and directed.
Supply and laying Galvanised iron pipe light grade of bore 40mm for protection of cable complete all as directed by Engr-in-Charge.
S & F PVC junction boxes of any description and in any position on poles or fixed in the plinth of poles and Supply, install, test and commissioning factory made THERMOPLASTIC CABLE JUNCTION BOXES IP 66 “weather proof”, for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with MCB SP 10 Amp and 4 busbar of alluminium low voltage capacity 100A each, glands including with ss rod clamps of , nuts and bolts as approved and directed by Engineer-in-Charge.
UMA CONSTRUCTION (BID ID -3503596)
City Light (BID ID -3497138)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
TENDER82276.pdf
Tender Documents • 1.30 MB
BOQ_819493.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid