Loading…
Loading…
Tender Value
₹5.2 Cr
EMD Value
₹10.5 L
Closing Date
3 Aug 2026, 3:00 pmClosed
Superintending Engineer, 9th Circle, PWD, Dehradun
Superintending Engineer, 9th Circle, PWD, Dehradun
Construction of 20 Mtr. span R.C.C. girder bridge (two-lane) in the downstream of Salawala Bridge at km 1, chainage 0.350 of New Cantt Road, under the Mussoorie Constituency of District Dehradun under the State Sector.
2026_pwd_96775_1
3468/1C-9/2026, Dated 10/06/2026
Open Tender
Civil Works - Bridges
Item Rate
365 days
New cantt Road, Mussoorie Constituency
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
Executive Engineer, Cons.Div., PWD, Dehradun
₹10.5 L
Superintending Engineer, 9th Circle, PWD, Dehradun
3 Aug 2026
18 Jun 2026
3 Aug 2026
18 Jun 2026
3 Aug 2026
2 Jul 2026
1 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as perdrawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1200 mm) | 477.6 | Rm | - | - |
| 2 | Plain/Reinforced cement concrete in open foundation complete as per drawing and technical Specification.
PCC Grade M15 Case II With Batching Plant, Transit Mixer and Manual placing | 33.64 | Cum | - | - |
| 3 | Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications | 157.89 | MT | - | - |
| 4 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications | 106.66 | MT | - | - |
| 5 | Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications | 20.42 | MT | - | - |
| 6 | Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification
RCC Grade M35
(ii) With Batching Plant, Transit Mixer and Manual placing | 605.68 | Cum | - | - |
| 7 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specificationsRCC Grade M35 Height upto 5m With Batching Plant, Transit Mixer and Concrete Pump | 349.76 | cum | - | - |
| 8 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications RCC Grade M35 Height upto 5m to 10mtr With Batching Plant, Transit Mixer and Concrete Pump | 309.76 | cum | - | - |
| 9 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications RCC Grade M35 Height above 10mtr With Batching Plant, Transit Mixer and Concrete Pump | 104.08 | cum | - | - |
| 10 | Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical SpecificationRCC/PSC Grade M40
(ii) For T-beam & slab, (p) Height upto 5m | 67.77 | cum | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.53 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.35 MB
SBD_5.pdf
Tender Documents • 2.49 MB
BOQ_114321.xls
BOQ • 0.98 MB
letter5128.pdf
PDF • 0.34 MB
Letter5023.pdf
PDF • 0.66 MB
Letter_4837.pdf
PDF • 0.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .