Provision of fire suppression System at Kota EI
KOTA-SNT-SIG-2025-08
KOTA-SNT-SIG-2025-08
Open
Works - General
12 Months
Kota, Rajasthan
₹0
₹2.6 L
27 Jun 2025
27 Jun 2025
Item Breakup - sch-shedule
Supply of UL/FM/VDS/LPCB Listed Brass Nozzle Numbers type RV- BRZ, Nozzles shall have 360 Deg. /180 Deg. Throw, selection as per approved hydraulic flow calculations complying to RDSO/ SPN/218/2016 Version 1.0- d2 or Latest. Inspection : RDSO
Supply of 80 Litres Capacity seamless Cylinder Numbers CCOE approved, complete with valve assembly and digital pressure gauge with a safety burst disc and a safety cap and shall comply to RDSO/SPN/218/2016 or latest .. Gauge with a safety burst disc and a safety cap
Supply of 120 Litres Capacity seamless Numbers Cylinder CCOE approved, complete with valve assembly and digital pressure gauge with a safety burst disc and a safety cap and shall comply to RDSO/SPN/218/2016 or latest .. Gauge with a safety burst disc and a safety cap KOTA DIVISION-SIGNALLING AND TELECOMMUNICATION/WEST CENTRAL
Supply of 180 Litres Capacity seamless Numbers Cylinder CCOE approved, complete with valve assembly and digital pressure gauge with a safety burst disc and a safety cap and shall comply to RDSO/SPN/218/2016 or latest .. Gauge with a safety burst disc and a safety cap
Supply of UL/FM/LPCB Listed 24VDC Solenoid Numbers (Electrical) actuator assembly complying to RDSO/ SPN/218/2016 Version 1.0- d2 or Latest.Inspection : RDSO
"Supply of of Master Cylinder Adaptor kit used Numbers to actuate the slave Cylinder"
Supply of 1-1/2" Manifold check valve installed Numbers at the discharge manifold to allow removal of any FK-5-1-12 cylinder from the manifold while still retaining a closed system
"Supply of Cylinder strap use with 80/ 120/ Numbers 140L cylinder OEM manufacturer only."
Supply of Brass Male Elbow
"Supply of pilot line accessories with bleed Numbers valve at every end for pneumatically actuted Cylinder."
Supply of M S Seamless pipe as per Sch. 40 Lot ASTM106 Gr. B painted with 2 coats of primer and 2 coats of Red Enamel Paint as per the design & site requirements. It shall be as per flow calculations for the specific hazard volume and stand to hold, position & Support the Manifold and Piping properly. Pressure testing for piping shall be with Nitrogen as per NFPA 2001. Note : " NO" in Unit column means "LOT" Inspection : RDSO
"Supply of Cylinder rack support, pipe support, Lot manifold & all other acessories required to complete the system"
Supply of Gas release panel
"Supply of Relay Module and shall comply to Numbers RDSO/SPN/217/2021 ver 3.0 or latest. (Inspection : RDSO / RITES for Supply of portion)"
"Supply of Monitor Module with inbuilt fault Numbers isolator or alternate arrangement which shall isolate the module in case of short circuit and shall comply to RDSO specification no. RDSO/SPN/217/2021 ver 3.0 or latest. (Inspection : RDSO / RITES for Supply of portion)"
"Supply of Linear Pneumatic Heat Detection Metre Tube kit, (Standard) for In-Cabinet Automatic Fire Suppression System(ICAFSS) system as per RDSO specification no. RDSO/SPN/218/2016Ver 1.0-d2 or latest(inspection by RDSO)"
"Supply of master control unit for In-Cabinet Numbers Automatic Fire Suppression System(ICAFSS) system as per RDSO specification no. RDSO/SPN/218/2016Ver 1.0-d2 or latest(inspection by RDSO)"
"Supply of motorized Fire Damper with relay Numbers arrangement for tripping of Exhaust fan" Total 10815637.95 Item- 2 SHEDULE-B S No. Item Description of Item Unit Qty Rate Amount No KOTA DIVISION-SIGNALLING AND TELECOMMUNICATION/WEST CENTRAL
Supply, Installation, testing and commissioning Numbers of UL/FM/VDS/LPCB Listed Manual Actuator complying to RDSO/ SPN/218/2016 Version 1.0- d2 or Latest. Inspection : RDSO
Supply, Installation, testing and commissioning Numbers of UL/FM/VDS/LPCB Listed Pneumatic Actuation Assembly complying to RDSO/ SPN/218/2016 Version 1.0- d2 or Latest.
Design, Supply and Installation of of FK-5-1-12 Kg Fire protection fluid compound of carbon, fluorine and oxygen (CF3CF2C(O)CF(CF3)2) complying to RDSO/ SPN/218/2016 Version 1.0- d2 or Latest. Inspection : RDSO
Supply, Installation, testing and commissioning Numbers of UL/FM/LPCB Listed high pressure Discharge hose complete with Listed Adapters & Accessories as required. As per RDSO Specification No. RDSO/ SPN/218/2016 Version 1.0- d2 or Latest. Inspection : RDSO
Supply, Installation, testing and commissioning Numbers of UL/FM/LPCB Listed Discharge Pressure Switch complying to RDSO/SPN/218/2016 Version 1.0- d2 or Latest. Inspection : RDSO
Supply, Installation, testing and commissioning Numbers of UL/FM/LPCB Listed Pneumatic Actuation Hose complying to RDSO/ SPN/218/2016 Version 1.0- d2 or Latest. Inspection : RDSO
Supply, Installation, testing and commissioning Numbers of UL/FM/LPCB Listed Human Proximity Sensor. It shall have Warning Sign Board with Marking "GAS DISCHARGE. DO NOT ENTER". Shall operate on 24 V DC, Driver Through Gas Release Panel (for use outside room) complying to RDSO/ SPN/218/2016 Version 1.0- d2 or Latest. Inspection : RDSO
"Supply and Installation of self contained fire Numbers tube extinghushier with FK-5-1-12 clean agent, Pressure gauge, Low pressure supervisory switch for suiatble to extinguish fire in air conditioner."
"Supply, commissioning of UL/FM/LPCB Listed Manual Release Unit Stations with DPDT Relay, shall be fitted with transparent hinged covers to avoid the possibility of accidental operation. The Release switch will be monitored simultaneously by Fire Alarm and Remote Monitoring Software complying to RDSO/ SPN/218/2016 Version 1.0- d2 or Latest. Inspection : RDSO"
Supply, Installation, testing and commissioning Numbers of UL/FM/LPCB Listed Manual Gas Abort Unit Stations with DPDT Relay, shall be fitted with transparent hinged covers to avoid the possibility of accidental operation. The abort will be monitored simultaneously by Fire Alarm and Remote Monitoring Software complying to RDSO/ SPN/218/2016 Version 1.0- d2 or Latest. Inspection : RDSO KOTA DIVISION-SIGNALLING AND TELECOMMUNICATION/WEST CENTRAL
Supply and Installation of In cabinet automatic Set fire suppression system(ICAFSS), (Enclosure volume-Approx 2.7 Cu Mtr) with following provision- 2Kg clean agent capacity Seamless Aluminium Seamless cylinder of 2.7 Ltr water capacity (UL & PESO approved) Test Pressure 53 Bar, fitted with DLP valve- 1No, clean agent Gas(FK5-1-12)-2 Kg, heat detection Tubing sensing temprature 160 Degcree Celcius (UL Approved)-10 mtr, Pressure Gauge(UL Approved) and Pressure Switch(UL Approved)- 1No and EOL In cabinet Monitoring Panel 1(ICMP) along with sounder/strobe, suitable ot monitor up ot 4 Nos of ICAFSS SVS Firetrex make or similar comlete in all respect with all necessary accessories. The system will have an interface with main fire alarm control panel through monitor module as per RDSO specification RDSO/SPN/218/2016 ver1.0 or latest
Supply, Testing & Commissioning of Hooter Numbers cum Strobe complying to the RDSO/SPN/217/2021 Ver 3.0 or latest. Spares shall be suppled as per RDSO spcn.
Supply, Testing & Commissioning of 2C 1.5 sq Metre mm twisted shielded armoured copper cable (Per Meter) with accessories. Spares shall be supplied as per RDSO spcn.
UL/VDS Flow Calculation
"Installation of motorized Fire Damper with Numbers relay arrangement for tripping of Exhaust fan"
Installation, testing and commissioning of Job Automatic fire (Suppression) protection system complete with cylinders, aspiration sensor, gas discharge piping, control Panel, flame sensor, smoke as per RDSO SPN No. RDSO/ SPN/218/2016 Version 1.0- d2 or Latest sensors, hoses, actuator etc. and this also includes Supply, Installation, Testing and commissioning of Integrated Remote Monitoring system Software for complete as per specifications, for integrating, Fire alarm system, VESDA system for monitoring at Division Head Quarter including scope such as Remote Monitoring Software 1 no. and 32 Bit IP based Direct Digital controller 1 no. with on board NBacmet & Modbus protocol for Integration with Fire Alarm Panel to monitor status of cylinder pressure switch, panel operating mode, Fire status on Remote Monitoring Software. The software should have capabilities to send mail alert. The system should comprises of necessary panel, switches, cables etc. required to complete the Job.
Installation, Testing & Commissioning of LHS Numbers Interface Module with all accessories for single stretch, complying to RDSO/SPN/217/2021 Ver 3.0 or latest. Spares shall be suppled as per RDSO spcn. Total 11264467.54
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .