Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.1 L+₹9.3 L (26.0%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L2 | Rejected-Finance L2 | |
| 3 | L3₹45.2 L+₹9.4 L (26.2%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹46.0 L+₹10.2 L (28.4%)Rejected-Finance | L4 | Rejected-Finance L4 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Aman Bhardwaj
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No.1 Jamnagar 361 003
REPAIR / MAINTENANCE OF COOLING APPLIANCE AND CONNECTED ITEMS UNDER GE(AF) JAMNAGAR NO. 01
2023_MES_602541_1
8238/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE(AF) JAMNAGAR NO.1
Please refer Tender documents
6 documents required · 6 mandatory
₹500
GE(AF)JAMNAGAR NO.1
₹80,000
Yes
31 Jul 2023
10 Jun 2023
15 Jul 2023
10 Jun 2023
13 Jul 2023
29 Jun 2023
Amount
M & L for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush , refixing the front cover of indoor unit . Remove the outer cover of out door unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressureized water then apply one coat of descaling solution and clean with wire mesh brush/nylon brush to the condensing coil of out door unit and greasing of all moving parts. Cleaning of Cooling and ....../-
…/-condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection Complete all as specified and directed by Engr-in-Charge. Note - Replacement of defective parts with new parts shall be measured and paid seperately under respective items in the schedule.
Material and labour for Leak testing of cooling coils attached with indoor and outdoor unit of split air conditioner uisng CO2/Nitrogen gas, arrest of leakage with brazing of copper pipe and retest again for leakage complete all as specified and as directed.
M & L for charging of refrigerant R-410 gas to air conditioner or as per existing /manufacturer instructions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant , vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions, as mentioned above complete all as specified and as directed by Engr-in-charge
All as per item no.3 above but for 2.0 ton capacity complete as per manufacturer instructions and as directed by Engr-in-Charge.
M & L for charging of refrigerant R-22 gas to air conditioner or as per existing /manufacturer instructions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant , vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions, as mentioned above complete all as specified and as directed by Engr-in-charge
All as per item no.13 above but for 2.0 ton capacity complete as per manufacturer instructions and as directed by Engr-in-Charge.
Material and labour for maintenance of air conditioner 1.5/2.0 ton capacity , Split type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load complete all as specified and as directed by Engr-in-charge
S & F in repair over load protector suitable range and capacity
S & F in repair Starting capacitor 80/100/120 mfd suitable for 240 volts 50 HZ AC supply
S & F in repair Running capacitor of 36/45/50/60 + 5/6 mfd suitable for 240 volts 50 HZ AC Supply
S & F in repair capacitor of 2.5 mfd suitable for suitable for blower fan motor of 1.5/2.0 ton AC
S & F in repair thermostat switch of suitable suitable for 1.5/2.0 ton AC
S & F in repair Compressor relay of suitable suitable for 1.5/2.0 ton AC
S & F in repair Control relay of suitable suitable for 1.5/2.0 ton AC
S & F in repairs brass service valve of size 5/8" suitable for Split AC
S & F in repairs brass service valve of size 3/8" suitable for Split AC
S & F in repairs copper tubing of size 3/8" suitable for split AC with nitrile self adhesive foam wrapped with PVC insulation all around the pipe line complete
S & F in repairs copper tubing of size 5/8" suitable for split AC with nitrile self adhesive foam wrapped with PVC insulation all around the pipe line complete
Supply and fix in repair flexible PVC pipe for condense water outlet as per existing all as directed & as site requirement.
S & F in repairs copper condenser coil suitable for split AC of cap 1.5/2.0 ton complete with necessary electrical connection
S & F in repairs evaporator copper cooling coil suitable for indoor unit split AC of cap 1.5/2.0 ton complete with necessary electrical connection
S & F in repairs Blower motor of 1/7 HP to 1/6 HP 230 volts 930 RPM, 20 Watt, 3 speed for indoor unit of split AC 1.5/2.0 TR of existing make complete Make :- Carrier/Voltas/LG/Samsung or as per existing make of AC at site.
S & F in repairs condenser fan motor 1/8 to 1/12 HP, 900/1400 RPM, 60 Watt suitable for 1.5/2 TR split AC outdoor unit, single phase, of existing make complete. Make:- LG/Bluestar/Voltas or as per existing make of AC at site.
S & F in repairs Condenser Fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete
S & F in repairs Blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete
S & F in repairs Blade set of fan motor of out door unit, made out of Aluminium sheet Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type
S & F in repairs Blade set of fan motor of out door unit, made out of PVC Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type
S & F in repairs Pre-air filter made up of PVC for indoor unit of split AC suitable for any make and description complete
S & F in repairs PVC fan blower assembly for 1.5 /2TR split AC's any make
S & F in repairs Printed circuit board(PCB) with suitable for Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection.
S & F in repairs Printed circuit board(PCB) with hand set of indoor, outdoor and display unit suitable for Inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection.
S & F in repairs Swing motor of suitable for indoor unit of split AC suitable for any make and description complete
M & L for repairs to internal remote assembly cordless type suitable for split air conditioner with replacement of PCB, LED indicator and other micro components complete all a specified and directed by Engr-in Charge
M & L for replacement of defective cut open compressor/Uncut compressor suitable for air conditioner with new compressor filled with capila D and charging of refrigerant gas up to required capacity after flushing the complete refrigerant system including repair to leakage if any in refrigerant piping and replacement of filter complete for split type AC's of the following capacity complete all as specified and directed by Engr-in-charge.
1.5 ton capacity
2.0 ton capacity
S & F in repair air conditioner outdoor unit single phase as per existing brand complete with all connection and taking out old unsv for the following cap of air conditioner. Make : Samsung/Voltas/Carrier/LG/O General
1.5 ton capacity
2.0 ton capacity
Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from old location to new location (with AF station Jamnagar), refixing of same AC at new location complete all as directed by Engr-in-Charge & detail as under:- (a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers.
(b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer. (c) All civil work such as making hole in the wall for passing of pipe etc, to be done, as directed by Engr-in-Charge including making good disturbed surface. (d) concealing of refrigerant pipe with PVC flexible pipe. (e) Extension of pipe due to site condition if required shall be measured and paid separately under respective items taken before.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including heavy duty PVC rigid conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment.
Supply and fix MCB’s single pole 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. Make :- ABB/LEGRAND/HAVELLS/L & T
Supply and fix MCB’s triple pole, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. Make :- ABB/LEGRAND/HAVELLS/L & T
Supply and fix in repair metal clad single pole and earth enclosure with two pin and earth plugs and socket complete with one single pole MCB 20 Amps, 230 V, C type. Make of enclosure Legrand/Roma/Jaguar and Make of MCB ABB/LEGRAND/HAVELLS/L & T
Comprehensive / Preventive maintenance of Industrial type Air conditioning of capacity 2.0 TR (Make: Emerson) with connected indoor and outdoor units, maintenance shall be carried out as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge. (a) Cleaning the evaporator coil of indoor unit with pressureized water then apply one coat of descaling solution and clean with nylon brush and then testing/ checking of evaporator coil for leakage and rectification of leakage by brazing including. (b) Cleaning of condensing coil of outdoor unit with pressurised water and then testing/ checking of Cooling coil for leakage and rectification of leakage by brazing including.
(c) Testing / Checking and Cleaning of Air filter. (d) Testing / Checking of compressor for its proper functioning and rectification of minor defect if any. (e) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any. (f) Testing / Checking & servicing of condenser fan motor and rectification of minor defect if any. (g) Testing / Checking of control switch such as pressure cut outs, refrigerent flow switch, temperature sensor for proper functiong. (h) Testing / Checking of refrigerant pipe for leakage and Rectification of leakage by brazing including cleaning of refrigerant pipe. (j) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete.
Material & labour for charging of refrigerant R-407 gas to 2.0 TR capacity industrial type intelle split AC after flushing the complete system, vacuum testing up to 24 hours and the repairing the leaking tube / lines by brazing, including charging the unit with appropriate qty of gas as per manufacture's instruction complete all as directed by Engineer-In-Charge.
Dismantling blower fan motor (HP-0.33 , V-415, RPM-920) of industrial type intelle split AC 2 TR and supply and fixing new fan motor along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge. Make :- SPARTAN ELECTRICAL PVT LTD or any other make as per recommendation of OEM and approved by the GE.
Dismantling Condenser fan motor(KW-0.18,RPM-920,FRAME-S90, IP-44) of industrial type intelle Split AC 2.0 TR capacity and supply and fixing new fan motor along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge. Make :- SPARTAN ELECTRICAL PVT LTD or any other make as per recommendation of OEM and approved by the GE.
Material and labour for maintenance of Industrial type air conditioner 2.0 ton capacity, Split type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load complete all as specified and as directed by Engr-in-charge
Supply and fix in repair LP switch 60 NO 35 PSI , 6A 250V suitable for compressor of industrial type intelle split AC 2.0TR Make - as per recommendation of OEM and approved by the GE.
Supply and fix in repair HP switch 400 NC 320 PSI suitable for compressor of industrial type intelle split AC 2.0TR capacity. Make - as per recommendation of OEM and approved by the GE.
Supply and fix in repair expansion valve suitable for industrial type intelle split AC 2.0 TR capacity. Model- TUBE 06802073 03989 , Make- Danfoss
Supply and fix in repair three pole contactor Model No. LC1D09 suitable for industrial type intelle split AC of 2.0 TR capacity.
Supply and fix in repair over load protection relay Model No. JRS4 09125D suitable for industrial type intelle split AC of 2.0 TR capacity.
Supply and fix in repair Supply Monitoring Device , Series-SM500,Type- PH, Neutral & Voltage Control suitable for control panel of industrial type intelle split AC. Cat id :- MACO4D0100E, Make - General industrial controls pvt ltd or or any other make as per recommendation of OEM and approved by the GE.
Supply and fix in repair transformer suitable for control panel of industrial type intelle split AC of 2.0 TR Capacity Emerson . Model:- 282500005012, Make-NANAP transformer pvt ltd or any other make as per recommendation of OEM and approved by the GE.
Supply and fix in repair Display Controller unit of Industrial type Air conditioning of capacity 2.0 TR. Model:- MCH2EP1031, Make- CAREL or any other make as per recommendation of OEM and approved by the GE.
Supply and fix compressor Copeland scroll type , three phase , 415V, AC suitable for industrial type split Air Conditioner 2.0 TR Capacity working with R-407 Refrigerant gas including Flushing the complete refrigerant system and supply including recharging the refrigerant to the required capacity after leak detection and repair if any in refrigerant piping and replacing the filter complete all as specified and directed. Make : Emerson Copeland Scroll, Model : 2R28K3E-TFD-522
Supply and fix PVC insulated and FR PVC round sheathed , copper conductor flexible industrial cable , 1100 Volts of size 4sqmm x 4 core. Make- HAVELLS or equivalent make mentioned in appendix `B`
Supply and fix PVC insulated and FR PVC round sheathed , copper conductor flexible industrial cable , 1100 Volts of size 4sqmm x 3 core. Make- HAVELLS or equivalent make mentioned in appendix `B`
Material and labour for servicing/cleaning of water cooler of storage capacity/ nominal cooling capacity(Ltrs/hr) 80/40 & 120/60 litres with the use of antiscaling agent for internal steel water tank ,outer body and condenser coil of water cooler, Removal of dust and other deposited material for the various functional equipment using smooth nylon brush ,cleaning of drainage for speedy water removal and checking of electrical connection to compressor and other electrically operated equipments, cleaning of fins and tubes of condenser,repair/replacement of PUF thermal insulation, checking of refrigerant leakage and functionality of water tap complete all as specified and as directed by Engr-in-charge
M & L for charging of refrigerant R-12/134a gas to water cooler for the following capacities as per existing /manufacturer instructions after flushing out the entire refrigerant , vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions,as mentioned above complete all as specified and as directed by Engr-in-charge
storage capacity 80 ltrs and cooling capacity 40 ltrs
storage capacity 120 ltrs and cooling capacity 60 ltrs
Material and labour for maintenance of water cooler with replacement of old/unsv spare parts as under including testing on load complete all as specified and as directed by Engr-in-charge
S&F in repair Reciprocating type compressor suitable for water cooler type 40/80 litres Make: Emerson copland/ carrier/ Blue star/Tecumsah
S&F Hermetic type compressor suitable for water cooler type 40/80 litres Make: Emerson copland/ carrier/ Blue star/Tecumsah
S & F in repair copper coiled condensor suitable for water cooler storage type of 40/80 or 80/120 Litres
S & F in repair Compressor relay suitable for water cooler storage type of 40/80 or 80/120 Litres Make: Kilxen/KCL/Electrica
S & F in repair running capacitor 36/45/50/60 + 5/6 mfd suitable for water cooler storage type of 40/80 or 80/120 Litres
S & F in repair thermostat suitable for water cooler storage type of 40/80 or 80/120 Litres Make: Indfoss/Renutrol /Rockwell
Material and labour for Leak test with CO2/Nitrogen gas and arresting leakage with brazing of copper pipe complete all as specified.
Dismantling condenser fan motor of capacity 1/7 to 1/5 HP suitable for 40/80 and 80/120 Ltrs water cooler and Supply and fixing in repair of new fan and motor a75 to 90 watt, make and size and refixing in position , connecting and testing on load complete all as specified and as directed by Engr-in-charge. Make: AUE/ GE Motors/ ABB
Material and labour for carrying out repair /maintenance/ servicing of Refrigerator of any capacity by periodic cleaning of internal and external parts, cleaning of water collection area and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Refrigerator in good working condition complete all as specified and directed by Engineer-in-Charge. Note: Defective spares required for replacement shall be measured and paid separately under respective items.
Material and labour for maintenance of Refrigerator any capacity with replacement of old/unsv spare parts as under including testing on load complete all as specified and as directed by Engr-in-charge
S & F in repair condensor suitable for Refrigerator of 195/ 250/ 300 ltr cap
S & F in repair cooling effect transmitting fan motor suitable for Refrigerator of 195/ 250 / 300 ltr cap
S & F in repair timer with timer relay suitable for Refrigerator of 195/250 / 300 ltr cap
S & F in repair Compressor Relay suitable for Refrigerator of 195/250 / 300 ltr cap or as per existing Make KCL/Rentrol/Indofos
S & F in repair thermostat suitable for Refigerator of 195/250 / 300 ltr cap Make: Indofos/Godrej/Annapurna
S & F in repair capillary with filter suitable for Refigerator of 195 250 / 300 ltr cap
S & F in repair Compressor suitable for Refigerator of 250 / 300 ltr cap or as per existing Make: Godrej/Teccumesh /Voltas/ Whirlpool/Kirloskar copland
Material and labour for Leak test with CO2/Nitrogen gas and arresting leakage with brazing of copper pipe complete all as specified.
M & L for charging of refrigerant R-134a gas to Refrigerator for the following capacities as per existing /manufacturer instructions after flushing out the entire refrigerant , vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions,as mentioned above complete all as specified and as directed by Engr-in-charge
Refrigerator cap 165/195 Ltrs
Refrigerator cap 230/250 Ltrs
Refrigerator cap 300/310 Ltrs
Material and labour for carrying out repair /maintenance/ servicing of Deep freezer of any cap of freezer with periodic cleaning of compressor placement area, cleaning of water tub and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Deep Freezer in good working condition complete all as specified and directed by Engineer-in-Charge. Note: Defective spares required for replacement shall be measured and paid separately under respective items.
Supply and fix in repair Thermostat of suitable capacity as per existing Freezer 95/145/188/285 /295 Ltrs
Supply and fix in repair Compressor relay of suitable capacity for Freezer 95/145/188/285 /295 Ltrs
Supply and fix in repair condensor motor of suitable capacity for Freezer 95/145/188/285 /295 Ltrs
Material and labour in repair for Condenser suitable for Deep freezer 95/145/188/285 /295 Ltrs
Material and labour for Leak test with CO2/Nitrogen gas and arresting leakage with brazing of copper pipe complete all as specified.
M & L for charging of refrigerant R-134a /R-600a gas to deep freezer or as per existing /manufacturer instrcutions after flushing out the entire refrigerant , vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions,as mentioned above complete all as specified and as directed by Engr-in-charge
Material and labour for servicing/cleaning of water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr of any make, with the use of antiscaling agent for internal steel water tank ,outer body and condenser coil of water cooler, Removal of dust and other deposited material for the various functional equipment using smooth nylon brush ,cleaning of drainage for speedy water removal and checking of electrical connection to compressor and other electrically operated equipments, cleaning of fins and tubes of condenser,repair/replacement of PUF thermal insulation, checking of refrigerant leakage and functionality of water tap complete all as specified and as directed by Engr-in-charge
M & L for charging of refrigerant R-12/134a gas to water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr of any make as per existing /manufacturer instrcutions after flushing out the entire refrigerant , vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions,as mentioned above complete all as specified and as directed by Engr-in-charge
Material and labour for maintenance of water dispenser with replacement of old/unsv spare parts as under including testing on load complete all as specified and as directed by Engr-in-charge
Supply and fix in repair compressor, single phase, 230 V suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr of any make.
S&F in repairs Copper Condenser coil suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr along with necessary electrical connections etc. all as specified and directed by Engineer-in-charge.
S & F in repairs Compressor relay suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr. Make :- as per recommendation of OEM and approved by the GE.
S & F in repairs running capacitor suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr. Make :- as per recommendation of OEM and approved by the GE.
S & F in repairs thermostat suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr. Make :- as per recommendation of OEM and approved by the GE.
S & F in repairs heating element with tank for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr. Make :- as per recommendation of OEM and approved by the GE.
Material and labour for Leak test with CO2/Nitrogen gas and arresting leakage with brazing of copper pipe complete all as specified.
Supply and Fix in repair voltage stabilizer for automatic operation , single phase naturally air cooled indoor type and designed for input variation voltage as under and output voltage stabilized at 230Volts with accuracy of ± 2.5% for the following capacity including depositing of old stabilizer at MES store yard complete all as specified and directed by Engr-in-Charge.
12 Amp suitable for 1.5 ton air conditioner for input variation between 150V to 290V Make : V Guard Model No VND 400 digital or equivalent in Microtek/Bluebird
15 Amp suitable for 2.0 ton air conditioner for input variation between 130V to 300V Make : V Guard Model No VBG 500 or equivalent in Microtek/Bluebird
Supply and fix in repair three pole connector suitable for voltage stabilizer 4KVA/5KVA Capacity. Make :- as per recommendation of OEM and approved by the GE.
Supply & fix in repair circuit relay 4 pin/ 5pin Suitable for voltage stabilizer 4KVA/ 5 KVA capacity. Make :- as per recommendation of OEM and approved by the GE.
M/s Jagdish Machinery Stores
SURESH ELECTRICALS
rajengineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .