Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC VILL P O MIRAGPUR DISTT SAHARANPUR 247554 U P | SAHARANPUR | UTTAR PRADESH | 247554 | ₹34.2 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹37.8 LRejected-Finance C 23 CC | ₹37.8 L | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹42.4 LRejected-Finance | ₹42.4 L | L3 | Rejected-Finance Other than lowest |
| 4 | Rejected-Technical 3491 14 HARIPURA DHAPAI ROAD AMRITSAR | AMRITSAR | PUNJAB | 143001 | - | - | Rejected-Technical Not enlisted in appropriate Class. |
| Sl No | Description | Qty | Unit | RAMAN CONSTRUCTION CO. L2 | RAMAPATI ENGINEERING SERVICES L3 | sath sahib associates L1 |
|---|---|---|---|---|---|---|
| 1.00 | Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed.
Note for all item of roof treatment :- (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof.
(b) The rates quoted shall deemed to be included for these items.
(c) The work will be measured only after stage passing by AGE(I). | 240 | Sqm | 40 ₹9,600 | 65 ₹15,600 | 30 ₹7,200 |
| 2.00 | M&L PCC (1:2:4) type B-0, using 12.5 mm graded stone agg mixed with integral liquid water proofing compound and over and including one coat of cement slurry admixes with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete/ mortar to old surface as per manufacturer instruction and finishing the surface even and smooth without using extra cement as in roof padding / sunken floor to receive water proof treatment complete all as specified and directed.
Note :- (SBR) Latex liquid polymer will be measured and paid seperately. | 9.6 | Cum | 5,350 ₹51,360 | 5,800 ₹55,680 | 4,500 ₹43,200 |
| 3.00 | M&L for water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :-
(a) Applying evenly a tack coat @ 1.2 kg/Sqm using 85/25 grade of industrial hot blown bitumen on primed surface of roof by applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated.
(b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer
(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance Note : (i) The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor.
(ii) The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items. | 240 | Sqm | 351 ₹84,240 | 495 ₹1.2 L | 350 ₹84,000 |
| 4.00 | Demolition of Lime Concrete in ground floor and pavings exc 15 cm thickness above ground floor (Sunken floor) including removal of rubbish out side MOD land complete all as specified and directed. | 5.26 | Cum | 599 ₹3,150.74 | 350 ₹1,841 | 50 ₹263 |
| 5.00 | M&L for PCC (1:1.5:3) type A-0, using 12.5mm graded stone aggregates, as in concrete angle-fillets with a radius of 75 to 100mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks etc. and other similar situation to ease up about corners mixed with integral water proofing compound as per manufacturer instruction complete )
Note :- Integral water proofing compound (WPC) will be measured and paid seperately. | 0.5 | Cum | 5,400 ₹2,700 | 6,800 ₹3,400 | 5,500 ₹2,750 |
| 6.00 | M&L for two coat of acrylic polymer modified cementitious flexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge complete all as specified and directed.
Note : Ponding test :- After water proofing coating, ponding test willl be done for ponding for 48 Hrs. | 20 | Sqm | 179 ₹3,580 | 300 ₹6,000 | 50 ₹1,000 |
| 7.00 | M&L for 15mm thick protection plaster in CM (1:4) as in floor and wall with polymer modified repair mortar (SBR Latex liquid polymer as per manufactur direction ) complete all as specified and directed.
Note :- (SBR) Latex liquid polymer will be measured and paid seperately. | 27 | Sqm | 229 ₹6,183 | 450 ₹12,150 | 200 ₹5,400 |
| 8.00 | M&L for 40 mm dia GI pipe, medium grade, as in spout pipe, projecting at least 300 mm beyond outer face of wall or as per direction of Engr-in-charge complete all as specified and as directed. | 3 | RM | 345 ₹1,035 | 350 ₹1,050 | 400 ₹1,200 |
| 9.00 | M&L for PCC (1:5:10) Type E2 (using 40 mm graded stone aggre-gate) as in foundations, sunken portion filling and mass-concrete complete all as specified and directed. | 3.67 | Cum | 1,529 ₹5,611.43 | 3,500 ₹12,845 | 2,500 ₹9,175 |
| 10.00 | M&L for 25 mm thick PCC (1:2:4) type B-0, using 12.5 mm graded stone aggregate, as in floor mixed with liquid water proofing compound as per manufacturer direction complete all as specified and directed.
Note :- Liquid water proofing compound will be measured and paid seperately. | 14 | Sqm | 279 ₹3,906 | 345 ₹4,830 | 200 ₹2,800 |
Updated dates
Tender Value
₹51.2 L
EMD Value
₹1.0 L
Closing Date
13 Feb 2026, 6:00 pmClosed
CWE Hills Dehradun
HQ CWE Hills Mall Road Dehradun Cantt 248003
SPECIAL REPAIR TO BLDG NO P-71 (08 QTR) OR MD ACCN AT RAIWALA MIL STN
2025_MES_746694_1
86470/RWL/E8
Open Tender
Civil Works
150 days
AGE (I) Raiwala
Class C Cat a (i)
6 documents required · 6 mandatory
₹1,000
Yes
AGE (I) Raiwala
₹1.0 L
Yes
13 May 2026
31 Dec 2025
21 Feb 2026
31 Dec 2025
13 Feb 2026
31 Jan 2026
Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed. Note for all item of roof treatment :- (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof. (b) The rates quoted shall deemed to be included for these items. (c) The work will be measured only after stage passing by AGE(I).
M&L PCC (1:2:4) type B-0, using 12.5 mm graded stone agg mixed with integral liquid water proofing compound and over and including one coat of cement slurry admixes with acrylic bonding compound SBR Latex liquid polymer as to be used for bonding of new concrete/ mortar to old surface as per manufacturer instruction and finishing the surface even and smooth without using extra cement as in roof padding / sunken floor to receive water proof treatment complete all as specified and directed. Note :- (SBR) Latex liquid polymer will be measured and paid seperately.
M&L for water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying evenly a tack coat @ 1.2 kg/Sqm using 85/25 grade of industrial hot blown bitumen on primed surface of roof by applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance Note : (i) The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor. (ii) The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.
Demolition of Lime Concrete in ground floor and pavings exc 15 cm thickness above ground floor (Sunken floor) including removal of rubbish out side MOD land complete all as specified and directed.
M&L for PCC (1:1.5:3) type A-0, using 12.5mm graded stone aggregates, as in concrete angle-fillets with a radius of 75 to 100mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks etc. and other similar situation to ease up about corners mixed with integral water proofing compound as per manufacturer instruction complete ) Note :- Integral water proofing compound (WPC) will be measured and paid seperately.
M&L for two coat of acrylic polymer modified cementitious flexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge complete all as specified and directed. Note : Ponding test :- After water proofing coating, ponding test willl be done for ponding for 48 Hrs.
M&L for 15mm thick protection plaster in CM (1:4) as in floor and wall with polymer modified repair mortar (SBR Latex liquid polymer as per manufactur direction ) complete all as specified and directed. Note :- (SBR) Latex liquid polymer will be measured and paid seperately.
M&L for 40 mm dia GI pipe, medium grade, as in spout pipe, projecting at least 300 mm beyond outer face of wall or as per direction of Engr-in-charge complete all as specified and as directed.
M&L for PCC (1:5:10) Type E2 (using 40 mm graded stone aggre-gate) as in foundations, sunken portion filling and mass-concrete complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B-0, using 12.5 mm graded stone aggregate, as in floor mixed with liquid water proofing compound as per manufacturer direction complete all as specified and directed. Note :- Liquid water proofing compound will be measured and paid seperately.
Supply only SBR Latex liquid polymer of approved make complete all as specified and directed.
Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed.
Demolition and breaking up drain pipes (PVC/ SGSW/ AC/ RCC pipe) of the following bore of pipe, set in cement mortar complete all as specified and as directed.
100 mm bore pipe
150 mm SGSW pipe
75 mm bore
110 mm bore
110 mm bore
75 mm bore
110 mm bore
75 mm bore
110 mm bore
75 mm bore
S&F 110mm PVC (SWR) WC connector with lip ring complete all as specified and as directed.
S&F PVC (SWR) reducers of size 110 mm x75 mm complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) with access door equal or unequal of following size complete all as specified and as directed :-
110 mm bore
75 mm bore
S&F 75 mm bore PVC (SWR) vent cowl complete all as specified and as directed
S&F PVC (SWR) multi floor trap, out let dia 75mm, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F PVC (SWR) P trap, out let dia 110mm, plain with grating including jointing with solvent cement complete all as specified and as directed.
M&L for 150 mm salt glazed stone ware (SGSW) pipe, grade A, ISI marked, laid in trenches and jointed in CM (1:1) complete all as specified and directed.
M&L for 150/100 mm dia pipe cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed.
S&F stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for following bore of pipe complete all as specified and directed :-
100mm bore pipe
75mm bore pipe
Demolition of concrete of any description and in any position not otherwise specifically provided for Cement concrete ( reinforced) including removal of debris etc to a distance out side MoD land complete all as specified and directed.
M&L for RCC (1:2:4) Nominal mix (using 20mm graded stone aggregates) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, and in shelves complete all as specified and directed.
M&L for RCC (1:2:4)type B0 (using 12.5 mm graded stone aggregates) as in Chajjas/ fins/ facia of roof slab including form work and one coat of SBR latex as bonding of old concrete to new concrete complete all as specified and directed. Note- 1.The Cost of SBR latex shall deemed to included in the rate. 2. The work is required to be carried out at double storyed. The cost of scaffolding, safety and security of workers and approach to roof shall deemed to included in the rate.
M&L for formwork for rough finish to soffits of suspended slabs such as roof slabs, floor slabs, landing slab and similar work, not exceeding 200mm thick complete all as specified and directed.
M&L for precast RCC (1:2:4) type B1, (using 20mm graded stone aggregates) as in cover slab (for manholes) and set in CM (1:4) including necessary fair finish formwork complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete and all as specified and directed.
M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Demolition of PCC in ground floor and pavings not exc 15 cm thickness below or above ground level including removal of rubbish out side MOD land complete all as specified and directed.
M&L for PCC (1:4:8) Type D2 (using 40 mm graded stone aggre-gate) as in foundations, filling and mass-concrete or sub base of floor/ hard standing/ footpath complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ disintigrated rock comlete all as specified and directed.
M&L for PCC (1:2:4) type B-1, using 20 mm graded stone aggregates, as in roof kerb/ benching/ coping, bed plates, for fixing of hold fast, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
Removal of surplus soft disintigrated rock to a distance n'exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of following size complete all as specified and directed:-
Area not exc 1.5 sqm each
Area exc 1.5 sqm but not exc 4 sqm each
M&L for 30mm thick Factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15x15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density of the shall be as per manufacture instruction complete all as specified and directed.
M&L for 35 mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter comprising of virgin polymer of K-value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk stainless steel screws complete all as specified and directed. Note: stainless steel butt hinges and necessary stainless steel screws shall be paid separately.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows and other frames/ chowkhat of following size comprising of virgin PVC polymer having K-value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and direction. Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable and variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. (ii) M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately.
65mm x 100mm size
65mm x 125mm size
M&L factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) complete all as specified and directed.
S&F second class hard wood (sal) plain, fillets, square, rectangular or triangular in section clean sawn, secured with nails of following sectional area complete as specified and as directed:-
Sectional area exc 13 sq cm but not exc 25 sq cm
300 mm long
200 mm long
200 mm long
300mm long
100 mm long
150mm long (overall length of cover plate)
S&F in repairs for stainless steel non magnetic curtain rod of 25 mm dia with and including fixing brackets and decorative type knobs (as approved by AGE (I)/ GE) both side of each rod complete all as specified and directed. Note: - Measurement will be taken between end point of knobs.
S&F aluminium door seal upto 1200mm long on bottom of door complete all as specified and directed.
S&F 18 mm thick solid WPC board both side prelam for cabinet boxes & shutter , cup boards, drawer, etc with shelf and shutter incl lipping to edges of exposed surface including provn of fixing arrangement complete all as specified and directed.
S&F continuous (piano) hinges, mild steel bright finish or electro galvanised width of flaps (when open) 30mm complete all as specified and directed.
S&F Aluminium Hat and coat hooks, solid body, 175mm to 250 mm complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with old size full brick subclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
M&L for brick work with old size half brick subclass ‘B’ burnt clay bricks, straight or curved on plan to any radius, built in CM (1:4) complete all as specified and directed.
Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water and removing unseviceable materials out side MoD land complete all as specified and as directed.
M&L for 5 mm thick rendering in cement plaster (1:3) as in ceiling surfaces and fininshed surface even and smooth without using extra cement complete all as specified and directed.
M&L for three coats of white wash on new ceiling surfaces including preparation of surfaces complete all as specified and directed. Note :- The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per satifaction of Engr-in-Charge.The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted.
M&L for preparing old decorated plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot and applying two coat of white wash complete all as specified and as directed.
M&L for 15mm thick plastering on fair faces of brick wall in two layers, Ist layer 10mm thick CM (1:6), and IInd layer 5mm thick CM (1:4), surface finished even and fair mixed with @ 200ml per bag WPC (liquid type) complete all as specified and directed. Note :- WPC (Liquid type) shall be measured and paid separately as supply only.
M&L Complete removal of existing treatment by mechanised system on walls internal or external surfaces in any height complete all as specified and directed.
M&L preparation of new or plastered or unplastered and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
M&L preparation of old or plastered or unplastered and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and directed.
M&L for 15mm thick plastering on fair faces of brick work or concrete surfaces in CM (1:6) finished even and smooth without using extera cement complete all as specified and directed.
M&L preparation of new plastered or unplastered and applying two coat of distemper oil emulsion white or tinted over and incl of one coat of alkali resistance priming paint and 1mm thick wall care putty on wall surface Complete all as specified and directed.
M&L preparation of old plastered or unplastered and applying two coat of distemper emulsion white or tinted over and incl of one coat of alkali resistance priming paint and 1mm thick wall care putty on wall surface Complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises from MoD land complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed.
M&L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square/rectangular) area of each tile exe 0.18 sqm but not exe 0.36 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I)
M&L for Non- skid coloured ceramic tiles of any design and pattern, 300X300X 7 to 8mm thick, in floor etc Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects.complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I)
S&F Screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed.
M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8 mm thick, as in dado etc, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects.complete all as specified and directed. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE (I)
M&L for 10 mm thick plastering on other than fair faces of brick work or concrete surfaces in CM (1:4) to receive glazed tile/ granite complete all as specified and directed.
M&L for mirror polished machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror finish polishing complete all as specified and as directed Note:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.)
Description same all as per item No 80 above but, as in skirting/ dado (10-12mm thick Kota stone) over and including 10mm thick rendering in cement mortar (1:4) complete all as specified and as directed.
S&F Screed bed or bedding layer of mortar 20 mm thick in CM 1:4 for laying floor finishes complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M & L 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including ointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Disconnecting and dismantling of water storage tank and removing from the site of following capacity of tank complete all as specified and as directed:-
Capacity exc 500 Ltr but not exc 1000 Ltr
S&F 1000 Ltrs Capacity rotational moulded polyethylene water storage tank, white in colour triple layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings, complete all as specified and as directed.
S&F 20mm bore ( minimum weight 210gms) ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipes or brass ferrule and fixed complete all as specified and as directed
Taking up or down steel water tubing (GI Pipe) and connections of following bore complete all as specified and as directed :-
15mm bore
20mm bore
25 mm bore
Cutting chases,in brick or concrete surface pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring,etc. and making good, cutting not exc 10 cm girthcomplete all as specified and directed.
S&F galvanised steel water tubing (GI pipe), medium grade with all fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :-
15mm bore
20mm bore
25 mm bore
20 mm bore
S&F 20 mm bore gun metal globe or gate valves, ISI marked, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed
S&F 25 mm bore gun metal globe or gate valves, ISI marked, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed
S & F in repair 15 mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle or concealed screwed both ends for iron pipe or for unions. complete all as specified and directed.
S&F chromium plated brass tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete all as specified and directed.
S&F in repair 15 mm bore bib taps, chromium plated, fancy type, long body, cast copper alloy with crutch handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed .
S&F in repairs shower rose 125 mm size chromium plated with or without swivel joints, any size, including fixing to 15mm GI pipe or union complete all as specified and directed.
S&F in repair Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long.complete all as specified and directed.
S&F glass corner shelf fancy type made of 6 to 7 mm thick sheet glass of size 250mmx250mm fixed with chromium plated brackets complete all as specified and directed.
S&F 600 mm long PVC connection 15 mm size with PTMT nut complete all as specified and directed.
S&F in repair Wash basins (Padestal pattern) 550x400mm vitreous china (flat back type) any 40 mm size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fitting complete all as specified and directed.
S & F for Grating ,cockroch proof, round 125 mm dia chromoum plated complete all as specified and directed.
S&F 5mm thick bevelled edge best quality looking mirror of size 600x450 mm with 30mm PVC beading all around the glass, mounted over 3mm thick PVC sheet or 6mm thick AC bldg board, complete all as specified and directed.
S&F in repair PVC valveless, syphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia of make as approvrd by GE/AGE(I) complete all as specified & directed.
S&F in repair vitreous china squatting pan of “Orissa” pattern of size 580 mmx 440mm white with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and as directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern), coloured, with and including plastic water closet seat cover, coloured, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device, ( excluding fixing bolts, flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, anti -syphonage pipe, etc., complete all as specified and directed.
S&F 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut capstan head screwed for 15mm dia pipe fixed in repair complete all as specified and directed.
S&F low density polythene pipe (LDPE) of pressure rating 6 Kgf / sqcm fixed to wall or laid in floor etc including fittings of following size complete all as specified and as directed :-
32 mm bore
S & F in repairs Sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 and bowl size 410mm x 330 mm x 160mm complete all as specified and as directed.
S&F Stainless steel kitchen plate rack 24 gauge thick sheet of over all size 31"x26"x10" fixed with steel screws and steel rawl plugs complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight per sqm not exc 4kg complete all as specified and as directed.
S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed. Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed.
M&L providing and injecting chemical for post construction anti termite treatment of soil under existing floor using emulsion @ one ltr per holes 300 mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 to match the existing floor complete all as specified and directed.
M&L for post construction anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
Excavating in trenches n'exc 1.5 m width and n'exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n'exc 10 sqm on plan and n'exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for Cement concrete ( unreinforced) including removal of debris etc to a distance out side MoD land complete all as specified and directed.
M&L concrete bed to pipes in PCC (1:4:8) type D2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid on slope and tested for following bore sewer pipe line complete all as specified and directed :-
150mm bore
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removal of surplus soil to a distance n'exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Removing excavated material exc 1.5 Km but n.exc 5.0 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L for cutting of bushes small trees (Peepal small plants etc) trunks shrubs of any dia and girth from roof projection, chajjas , wall junction parapet etc at any height by necessary demoliton of brick work etc if requried and making good distrubed surfaces to match with existing finihes with and including in CM (1:4) mixed with WPC /PCC (1:3:6) type B0 /Bk work in CM (1:4) as required at site and as directed by Engr-in-Charge.
S&F of Heavy duty telescopic channel of 20-22 inch complete all as specified and directed.
M&L for writing letters or figures (Block, Roman, Italic or Indian) not exc 30cm high complete all as specified and as directed.
Cutting holes into or through brick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete.Superficial area n exc 150 sqcm complete all as specified and as directed.
Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc to store and rubbish not exc. 50m complete all as specified and as directed.
Dismantling of asbestos cement ( corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Ball catches with 8 mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed.
M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. Note:- Punned thickness shall be considered for payment purpose.
Supply and laying cable protection bricks, common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed.
Supply and laying GI tube light grade 50 mm dia with all fittings laid in trenches or fixed on pole for protection of cable while fix on pole or HT pole structures pipe tightend with D type steel clamp, washers, nut, bolt etc. complete all as specified and directed.
M & L for cutting of road /hard standing as required at site, not exceeding 20 cm width and not exceeding 90 cm in depth for laying of cable protection pipe including insert the cable inside pipe making good the disturbed road/hard standing by providing PCC (1:2:4) Type B-1 up to the existing surface level and make good complete all as specified and directed.
M&L for 25 mm dia Straight plain brass ferrules (or connecting screws) screwed both ends and fixed complete all as specified and directed.
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 25 mm complete all as specified and directed.
M & L Construction of brick masonry chamber of 60 cm x 60 cmx 60 cm [internal dimensions] suitable for 25mm/50mm bore sluice valve with PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation brick wall with sub class ‘B’ brick, old size built in CM 1:6 PCC [1:2:4] type B1 [using 20 mm graded stone aggregate for coping rendering in CM [1.4] 15 MM thick including provision of MS sheet cover 3 mm thick with two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as specified and directed.
Dismantling and taking down U/S copper / aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed.
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and as directed.
Dismantling and taking down Taking down old damaged existing DBs of any tupe and making good the disturbed surface of wall/ceiling to match with the existing wall/ceiling etc complete all as specified and directed.
Taking down old unserviceable wooden meter box of any size & any type from wall by disconnecting all electrical connections complete all as specified & directed.
Taking down energy meter from wooden/steel meter box carefully and deposit to MES store yard complete all as specified & directed.
Taking down ceiling fan/exhaust fan, sealing cable end, dismantling blades and removing fan and blades deposit to MES store yard and complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC),remoteless and complete connection with two core flexible wire to wiring with all accessories and all as specified and directed. (Note: Flexible wire shall be measure and paid seperately)
All as per item No 146 above but for one light point controlled by one no of one way switch single pole, complete all as specified and directed.
All as per item No 146 above but for one ceiling fan point controlled by one no of one way switch single pole, complete all as specified and directed.
All as per item No 146 above but for one Exhaust fan point controlled by one no of one way switch single pole, complete all as specified and directed.
All as per item No146 above but for one call bell point controlled by one no of bell push, complete all as specified and directed.
All as per Item No 146 above but for One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
All as per item no 146 but for One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed.
All as per item no-146 bove but controlled by two, two way switch 5/6 Amps. With cables 1.5 sq mm size complete all as specified & directed.
All as per item No 146 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed. (Geyser point + power point)
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed.
Supply and fixing switch modular, one-way 16/20 Amps, 1 module 240 Volts AC complete all as specified and directed.
Supply and fix Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed.
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts, 50 hz complete all as specified and directed.
Supply and fixing switch modular flush type single pole, two way 6 Amp, 1 module ISI marked, 230 volts, 50 hz all complete all as specified and directed.
Supply and fixing bell push modular flush type single pole one way 6 Amps, 1 module with indicator, ISI marked complete all as specified & directed.
Supply and fixing bell multi music type AC 230/240 volts single pole, complete all as specified & directed.
Supply and fixing batten /angle holder insulated body with back plate, suitable for batten fittings all as specified & directed.
Supply and fixing ceiling rose surface bakelite 65/25 mm dia having three terminals complete all as specified & directed.
Supply and fixing 9 W LED lamp with B22 base in batten /anle holer and complete all as specified and directed.
Supply and fix surface mounted LED luminiare, 20 watt 4 feet with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 440 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >100-120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed.
Supply and fix surface mounted LED luminiare, 10 watt 2 feet with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed.
Supply and fixing in repair LED building security light 1X20 Watt housing made out of pressure die-cast aluminium alloy with toughened glass, IP-66 protection, working on 240 Volts , 50 HZ, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection up to 440 volts, Surge protection level ≥ 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiency > 130 Lumens/watt, power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including fixed on wall with 02 Nos MS clamp made out of 40X6 mm FI and bracket made out of 32 mm dia light grade GI pipe not less than 0.90 mtr long bend to shape complete all as Specified and directed including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from terminal box to light fittings complete all as specified and as directed.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar complete all as specified and directed .
Supply and fixing MCB SPN 10- 32 Amp 'B' series, 10 KA repturing capacity all as specified and directed.
Supply and fixing MCB SP 6 to 25 Amp 'B' series 10 KA rupturing capacity complete all as specified & directed.
Supply and fixing single pole and neutral enclosure with a two pole and earth plug socket complete with one, double pole MCB 20 Amps 10 KA rupturing capacity 240 Volts AC complete all as specified & directed.
S & F fresh air fan AC single phase 230/240 Volt of size 300 mm sweep, metallic body powder coated painted finish, Power consumption- 50 W, Air displacement -1290 Cum/Hr, RPM-900 complete with louvers including making whole and grouting of nut bolts etc and making good the disturbed surfaces of wall complete all as specified and directed .
Taking down existing Geyser keeping in safe custody and refixing the same including replacement of PVC connection and fastners complete all as specified and directed.
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/ concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire of 4.0 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to test point /machinery / equipment. supplying and laying charcoal dust comman salt PCC (1:2:4) type B1 using 20 mm graded stone agregrate chamber and RCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1 using 20 mm stone agrigrtae ) reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in electrical plate No-3 of SSR part-1 including testing and taking out the old one complete all as specified and directed Note - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
Tender86470.pdf
Tender Documents • 1.48 MB
BOQ_836131.xls
BOQ • 0.75 MB
Download all tender documents and submit your bid