Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC BIG NO 7 104 MANAKKATTU VAYANAKOM NJAKKAL POST KRISHNAPURAM VIA OACHIRA PANCHAYAT ALAPPUZHA KOLLAM DISTRICT KERALA STATE PIN 690 533 | ALAPPUZHA | KOLLAM | KERALA | 690533 | L1 | Accepted-AOC Accepted being lowest and reasonable. | |
| 2 | L2₹17.0 L+₹2.1 L (13.8%)Rejected-AOC | L2 | Rejected-AOC Not accepted. | |
| 3 | L3₹19.3 L+₹4.4 L (29.6%)Rejected-AOC JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L3 | Rejected-AOC Not accepted. | |
| 4 | Rejected-Technical JOY VILA MRA 230 MOOLAVILKOM JUNCTION VANCHIYOOR TRIVANDRUM 695 035 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695035 | - | Rejected-Technical NOT meeting eligibility criteria. |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
24 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE WELLINGTON
Headquarters Commander Works Engineers Wellington, Barracks Post The Nilgiris PIN 643 231
MAINT/ REPAIRS TO HT EXTERNAL ELECTRIC SUPPLY AND CONNECTED WORKS AT PANGODE MIL STATION UNDER GE (ARMY) TRIVANDRUM
2024_MES_647828_1
84811/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
TRIVANDRUM
As per NIT and tender documents.
7 documents required · 7 mandatory
₹500
GE (ARMY) TRIVANDRUM
₹36,000
15 Jun 2024
26 Mar 2024
1 May 2024
26 Mar 2024
24 Apr 2024
10 Apr 2024
27 Mar 2024 - 2 Apr 2024
Amount
Material and labour for dehydration and filtration of transformer oil using on line filtration plant to achieve di-electric strength not less than 50 KV/2 mm air gap complete all as specified for the following transformers including testing of transformer oil after filtration for the following capacities :- (a) Transformer 400 KVA - 01 No (b) Transformer 315 KVA - 04 Nos (c) Transformer 250 KVA - 01 Nos (d) Transformer 200 KVA - 04 Nos (e) Transformer 125 KVA - 01 No (f) Transformer 100 KVA - 05 Nos
Supply and topping up of new transformer oil of BDV not less than 50 KV in different transformer complete all as specified and as directed.
Disconnecting HT/LT connection of transformer, 11000/433V, 3 Phase, 4 wire system and opening up the top cover of transformer of capacity 400/315 KVA for checking the conditions to carryout repairs at site, including draining out oil from the transformer in suitable container and repair to the transformer with replacement of parts (as required), checking the lead connection from winding to bush rods including necessary soldering/jointing etc and after complete repair, refilling the dehydrated oil, replacing perished gasket with new gasket of same size and testing on full load after connecting the HT/LT connections complete all as specified and as directed.
Disconnecting HT/LT connection of transformer, 11000/433V, 3 Phase, 4 wire system and opening up the top cover of transformer of capacity 250/200 KVA for checking the conditions to carryout repairs at site, including draining out oil from the transformer in suitable container and repair to the transformer with replacement of parts (as required), checking the lead connection from winding to bush rods including necessary soldering/jointing etc and after complete repair, refilling the dehydrated oil, replacing perished gasket with new gasket of same size and testing on full load after connecting the HT/LT connections complete all as specified and as directed.
Disconnecting HT/LT connection of transformer, 11000/433V, 3 Phase, 4 wire system and opening up the top cover of transformer of capacity 125/100 KVA for checking the conditions to carryout repairs at site, including draining out oil from the transformer in suitable container and repair to the transformer with replacement of parts (as required), checking the lead connection from winding to bush rods including necessary soldering/jointing etc and after complete repair, refilling the dehydrated oil, replacing perished gasket with new gasket of same size and testing on full load after connecting the HT/LT connections complete all as specified and as directed. Note for item Nos 3.00 to 5.00: (i) The spares parts required shall be measured and paid separately. (ii) Dehydration of Transformer Oil will be measured and paid against item No 1.00 here in before.
Supply only for replacement of Gasket cork Sheet 5mm thick superior quality complete all as specified and as directed.
Supply only for replacement of HT bushing with brass spindle of transformer 11/0.433 KV of capacity up to 400/315 KVA complete all as specified and as directed.
Supply only for replacement of HT bushing with brass spindle of transformer 11/0.433 KV of capacity up to 250/200 KVA complete all as specified and as directed.
Supply only for replacement of HT bushing with brass spindle of transformer 11/0.433 KV of capacity up to 125/100 KVA complete all as specified and as directed.
Supply only for replacement of LT bushing with brass spindle of transformer 11/0.433 KV of capacity up to 400/315 KVA complete all as specified and as directed.
Supply only for replacement of LT bushing with brass spindle of transformer 11/0.433 KV of capacity up to 250/200 KVA complete all as specified and as directed.
Supply only for replacement of LT bushing with brass spindle of transformer 11/0.433 KV of capacity up to 125/100 KVA complete all as specified and as directed.
Supply and spread loose filling with aggregate of gauge 63mm inside the fencing of two pole structure/ four pole structure transformer yard unto a layer thickness of 150mm complete all as specified and as directed.
Supply and fix replacement of silica gel/ breather assembly clear view type of 11 KV/0.433 KV transformer capacity up to 400 KVA complete all as specified and as directed.
Supply and fix in repairs Dial type Temperature gauge, 0 to 100o C range complete with suitable to any make, type and capacity of transformer complete all as specified and as directed.
Supply and fix replacement of silica gel only standard type complete all as specified and as directed.
Material and labour for painting of transformer 11/0.433 KV of capacity up to 400/315 KVA with one coats of synthetic enamel grey colour paint with gun spray including surface preparation complete all as specified and as directed.
Material and labour for painting of transformer 11/0.433 KV of capacity up to 250/200 KVA with one coats of synthetic enamel grey colour paint with gun spray including surface preparation complete all as specified and as directed.
Material and labour for painting of transformer 11/0.433 KV of capacity up to 125/100 KVA with one coats of synthetic enamel grey colour paint with gun spray including surface preparation complete all as specified and as directed.
Material and labour for preparation and cleaning of old painted surface of the HT 2 pole structure, channels and cross arms clamps section up to 100mm x 50mm etc all exposed surfaces without dismantling, and applying two coats aluminium paint over a coat of zinc chromium primer for cross arms any number of each pole complete all as specified and as directed.
Material and labour for preparation and cleaning of old painted surface of the HT 4 pole structure, channels and cross arms clamps section up to 100mm x 50mm etc all exposed surfaces without dismantling, and applying two coats aluminium paint over a coat of zinc chromium primer for cross arms any number of each pole complete all as specified and as directed.
Material and labour for preparation of painted surface, cleaning the surface of Cross arms and all steel parts fixed with the RCC HT pole above the ground level including coping area and applying with two coats synthetic enamel paint complete all as specified and as directed.
Supply and fix in repair for Single Post insulator, 11 KV, 12mm dia with hardware fittings etc. complete all as specified and directed.
Material and labour in repairs lightening arrestor expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 6600 Volts including brackets, clamps, nuts, washers and connecting to earth wire 4mm dia GI wire complete all as specified and as directed.
Supply and fix in repairs Pin type Insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,150mm height, 150mm dia for 11000 volts grade etc complete all as specified and as directed.
Supply and fix in repairs switch air break, gang operated, triple pole, mechanically operated, mounted on 9 insulator and steel frame, with operating mechanism worked from ground level, having current rating upto 200 Amps for working pressure 11000 Volts with drop out type fuses (three numbers of 40 Amp capacity) including applying grease for male/ female contact and replacement of burnt termination grips etc complete all as specified and as directed.
Material and labour for aluminium conductor, steel reinforced on 11 KV over head line including dismantling the unserviceable ACSR conductor etc complete all as specified and as directed.
Material and labour in repairs cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Material and labour for repair/ maintenance of AB Switch 11 KV, Gang operated device of any type and size including cleaning of male and female contacts, greasing of all moving parts, replacement of all unserviceable contacts, insulators, replacement of GI pipe used to operating AB Switch complete all as specified and as directed.
Supply and fix in replacing of Male and Female Contacts of AB Switch complete all as specified and as directed.
Material and labour for replacing of Contacts of Drop out fuse assembly complete all as specified and as directed.
Removing grass, bushes and creepers growing at transformer yard, LT panel board, two pole structures and four pole structures and keep the yard area and surrounding neat and clean including spraying of necessary chemical required for destroying grass/ shrubs/ weeds etc complete all as specified and as directed.
Material and labour for cutting/ Trimming of tree branches 3 mtr all around apart from LT O/H line, two pole/ 4 pole structures, substations, cleaning of LT/OH conductor line and removing trimmed tree branches from site all as specified and as directed.
Supply and lay HT UG Cable, XLPE insulated, PVC sheathed, Armoured, Screened, Cross-linked polyethylene, Galvanised steel strip wire earthed, Electric power cable (heavy duty) with standard aluminium conductor, 6.35/11 KV, (Earthed) 11000 Volts grade of size 3 core 95 sqmm including taking out old unserviceable cable of any size complete all as specified and as directed.
Supply and lay HT UG Cable, XLPE insulated, PVC sheathed, Armoured, Screened, Cross-linked polyethylene, Galvanised steel strip wire earthed, Electric power cable (heavy duty) with standard aluminium conductor, 6.35/11 KV, (Earthed) 11000 Volts grade of size 3 core 185 sqmm including taking out old unserviceable cable of any size complete all as specified and as directed. Note for item No 34.00 & 35.00: Necessary earth work/ excavation, cable protection items shall be measured and paid separately.
Material and labour for replacement of cable jointing kit straight through joint, heat shrinkable for earthed grade cable suitable for 3 core 11 KV XLPE aluminium cable size of 50 to 95 Sqmm complete all as specified and as directed.
Material and labour for replacement of cable jointing kit straight through joint, heat shrinkable for earthed grade cable suitable for 3 core 11 KV XLPE aluminium cable size of 120 to 185 Sqmm complete all as specified and as directed.
Material and labour for replacement of cable jointing kit straight through joint, heat shrinkable for earthed grade cable suitable for 3 core 11 KV XLPE aluminium cable size of 240 to 400 Sqmm complete all as specified and as directed.
Material and labour for replacement of cable end termination jointing kit with all accessories for earthed system grade cable heat shrinkable outdoor type suitable for 3 core 11 KV XLPE aluminium cable of size 50 to 95 Sqmm complete all as specified and as directed.
Material and labour for replacement of cable end termination jointing kit with all accessories for earthed system grade cable heat shrinkable outdoor type suitable for 3 core 11 KV XLPE aluminium cable of size 120 to 185 Sqmm complete all as specified and as directed.
Material and labour for replacement of cable end termination jointing kit with all accessories for earthed system grade cable heat shrinkable outdoor type suitable for 3 core 11 KV XLPE aluminium cable of size 240 to 300 Sqmm complete all as specified and as directed.
Material and labour in replacement of synthetic Rubber insulated mats 2.5mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of size 2m x 1m complete all as specified and as directed.
Material and labour in replacement Danger notice plate for HT of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT 25cm x 20cm etc complete all as specified and as directed.
Material and labour for opening the cover of HT 11 KV 630A-800A, RMU Panel, cleaning the fixed and moving contacts inside the VCB properly, checking of alignment of spring charging mechanism, servicing and greasing all movable mechanism, replacement of defective MCB, wiring and checking the battery charger and the indoor cable terminal Boots complete all as specified and as directed.
Supply and fix in replacement of indoor cable terminal Boot (set of 3) for HT 11 KV 630A-800 A, RMU Panel complete all as specified and as directed.
Supply and fix in repairs Battery 7 AH (02 Nos), 12V DC with inbuilt charging unit for HT 11 KV 630A, RMU Panel complete all as specified and as directed.
Repairing and servicing of HT 11 KV VCB along with CTs/ PTs of current rating upto 400 A, rupturing capacity 250/ 200 MVA of any make and type by drawing out breaker assembly from panel and carry out the following work:- (i) Cleaning/ decarburizing of all fixed and moving contacts, levers, springs using suitable cleaning agent and tightening of screws, nuts, bolts, spring etc. (ii) Adjust the trolley in and out mechanism. (iii) Lubricating/greasing of all operating mechanism and moving parts, switching & tripping mechanism, automatic shuttering system, necessary brazing, turning, polishing of main and auxiliary contact, demoisturing of insulators, etc to be done. (iv) Testing of tripping performance of HT VCB by secondary current injection and testing of CT ratio and polarity. (v) Checking of tripping relay including interlocking elements of the mechanical clearances of the operating mechanism, internal wiring circuit etc, tightening of all connections, replacement of HRC fuse, fuse carrier base (if any found u/s) including removing moisture deposit inside the VCB. (vi) Checking all end terminals, Tighting the nut bolt and washers, replace the unserviceable nut, bolt & washers, draw-in the breaker, put in position, engage the VCB with the supply system and testing for smooth functioning.
Supply and fix of Closing Coil Assembly (110V DC) as per existing size, type and suitable for 11 KV VCB including taking down old item complete all as specified and as directed.
Supply and fix of Tripping Coil Assembly ( 110V DC) as per existing size, type and suitable for 11 KV VCB including taking down old item complete all as specified and as directed.
Supply and fix LED indicator of RED/ GREEN/ YELLOW/ AMBER including taking down old materials complete all as specified and as directed.
Supply and fix push button RED/ GREEN/ YELLOW/ BLACK including taking down old materials complete all as specified and as directed.
Material and labour for Calibration of protective relays both 02 Nos over current and 01 No earth fault relay of IDMT or any other type by using relay injection kit including necessary adjustment of over current / earth fault / earth leakage by secondary current injection test along with testing and calibration of pickup current, time setting multiplier, tripping delay time, auto resetting of time, etc for successful operation at the time of fault occurrence as required according to the connected load complete all as specified and as directed.
Supply and fix in replacement of Panel Heaters (Space heater 80W) and Thermostat including necessary wiring complete all as specified and as directed.
Material and labour in replacement for earthing galvanised steel earth plate electrode 600 x 600 x 6.00mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below normal ground level with top edge of the plate less than 1.5 mtr below normal ground level) connected to GI strip 32 x 6mm by means of bolts, nuts, check nuts, and washers, of galvanised iron or steel including GI pipe light grade 40 mm bore for protection of earth lead, GI funnel and wire mesh etc complete all as shown in Electrical plate No 3 of SSR 2009 (Part- I) including necessary excavation earth work, form work, earth pit of size 450 x 450 x 300mm of PCC M-15 (Nominal mix) using 20mm graded stone aggregate earth pit cover of PCC and 20mm bore light grade GI pipe for watering and charcoal dust, common salt, and connected to test point 7.5 mtr from earth pit including testing on completion with earth resistance value, complete all as specified and as directed.
Supply and fix in repair DC power pack with battery backup unit complete all as specified and as directed with following technical specification of DC power pack unit are as under:- (a) Input voltage : 110 VAC OR 230 VAC =20%, -30% (b) Input Burden : Less than 50VA during charging period without Output Load. (c) Output Voltage : 24VDC / 30VDC / 48VDC / 220VDC. (d) Output Load : 100W Nominal (e) Continuous Load : 100 Watts. (f) Impulse load : 450 W for 240 mSec (min. 10 pulses) (g) Overall Dimension : 280mm (w) x 190 mm (h) x 210 mm (d) (h) Weight : 7.0 Kg
Dismantling of unserviceable/ broken electric pole of any size and type with disconnecting all connections, demolition of concerted foundation including excavation earth work as required and removing the same from site complete all as specified and as directed.
Supply and erection of steel tubular swaged poles 11 meter long, type 410 SP-55 in true vertical position complete with cast iron base plate, final taper plug, bolts, nuts and screws pole cap etc conforming to IS-2713 (Part-1 to 3) 1980 including painting two coats of black bituminous paint throughout internally, and externally up to the planting depth and the remaining portion of the exterior shall be painted with two coats of aluminium paint over a coat of red oxide primer after necessary preparation of surfaces complete all as specified and as directed. Note: Necessary earthwork excavation, PCC for foundation/ coping shall be measured and paid separately
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard/dense soil and in road cutting all as specified and as directed
All as per item No. 58 described here-in-before but depth exceeding 1.50m and not exceeding 3.0m
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in hard/ dense soil all as specified and as directed
Removing excavated material/surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above starting point soil all as specified and as directed
Supply and lay reinforced precast concrete cable cover class-HV, Type-1 flat, size 300mm x 180mm x 40mm complete all as specified and as directed.
Material and labour for providing Plain Cement Concrete 1:4:8, type D-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete including necessary form work etc complete all as specified and as directed.
Material and labour for providing plain Cement Concrete 1:3:6, type C-2 with using 40mm grade stone aggregate as in foundation of steel tubular poles and stay with necessary form work as required complete all as specified and as directed.
Material and labour for providing plain Cement Concrete 1:2:4 type B-1 with using 20mm grade stone aggregate as in coping of steel tubular poles with necessary form work as required complete all as specified and as directed.
Supply and spreading in natural riddled soil as earth cushioning to cable by using IS sieve to separate the composite particle/ roots etc and refilling in trenches and compacted in layers to form a solid bed covering to cable all as specified and as directed. Note: Punned thickness shall only be measured.
PHEJAYS AGENCIES
JEETH CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .