Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.1 LAccepted-AOC | 1 | Accepted-AOC L1 accepted | |
| 2 | 2₹34.8 L+₹69,141.28 (2.03%)Rejected-AOC | 2 | Rejected-AOC L2 rejected |
Tender Value
₹37.7 L
EMD Value
₹50,000
Closing Date
17 Sept 2022, 6:00 pmClosed
Executive Engineer
O/O The Executive Engineer PWD Electrical division Thiruvananthapuram
Electrification to the newly constructed building for the Guest House, Ponmudi- Air Conditioning-Electrical AC Work
2022_PWD_506909_1
EDT_ET_20_2022_23
Open Tender
Electrical Works
Item Rate
153 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
5 Nov 2022
5 Sept 2022
20 Sept 2022
5 Sept 2022
17 Sept 2022
5 Sept 2022
Amount
SITC of Air Conditioning system
OD89639/2022-2023:SITC of inverter scoll compressor and dual inverter scroll compressors all outdoor units on or above 16 HP, auto refrigerant charging, refrigerant cooled PCB's and with advanced VRT/VET technology with R410A Refrigerant Including first filling including adequate supporting hardware, Vibration dampers, shut off valves etc. The Outdoor Units shall be factory treated using Anti-corrosive Hydrophilic Coating. High Voltage Cutoff System with Start time Delay, The scope shall also include Supply, Installation, wiring and programming of microprocessor based Controller / Control panel with communications capability of 20 HP
OD89640/2022-2023:SITC of inverter scoll compressor and dual inverter scroll compressors all outdoor units on or above 16 HP, auto refrigerant charging, refrigerant cooled PCB's and with advanced VRT/VET technology with R410A Refrigerant Including first filling including adequate supporting hardware, shut off valves etc. The Outdoor Units shall be factory treated using Anti-corrosive Hydrophilic Coating. High Voltage Cutoff System with Start time Delay, The scope shall also include Supply, Installation, wiring and programming of microprocessor based Controller / Control panel with communications capability of 18 HP
OD89641/2022-2023:SITC of the following 1.6 TR wall mounting type Indoor with panel ,Air Flow rate 530CFM unit shall be factory assembled,wired piped and tested, indoor units shall have provision for connecting Fresh Air Ducts excluding hi-wall units.All units shall be controlled by electronic expansion valves and mounted in side the ceiling shall have capable of sustaining duct connections and special filters if necessaryIndoor units to be slim type,medium static units,pre filters to be part of all indoor units and low db units .
OD89642/2022-2023:SITC of the following 0.80 TR wall mounting type Indoor with panel ,Air Flow rate 318CFM unit shall be factory assembled,wired piped and tested, indoor units shall have provision for connecting Fresh Air Ducts excluding hi-wall units.All units shall be controlled by electronic expansion valves and mounted in side the ceiling shall have capable of sustaining duct connections and special filters if necessaryIndoor units to be slim type,medium static units,pre filters to be part of all indoor units and low db units .
OD89644/2022-2023:SITC of the 2 TR ROUND FLOW CASSETTE TYPE INDOOR; Air Flow Rate - 830 CFM unit shall be factory assembled,wired piped and tested, indoor units shall have provision for connecting Fresh Air Ducts excluding hi-wall units.All units shall be controlled by electronic expansion valves and mounted in side the ceiling shall have capable of sustaining duct connections and special filters if necessaryIndoor units to be slim type,medium static units,pre filters to be part of all indoor units and low db units .
OD89645/2022-2023:SITC of the 3 TR ROUND FLOW CASSETTE TYPE INDOOR; Air Flow Rate - 1183 CFM unit shall be factory assembled,wired piped and tested, indoor units shall have provision for connecting Fresh Air Ducts excluding hi-wall units.All units shall be controlled by electronic expansion valves and mounted in side the ceiling shall have capable of sustaining duct connections and special filters if necessaryIndoor units to be slim type,medium static units,pre filters to be part of all indoor units and low db units .
OD89646/2022-2023:Supply of cord less Remote Handset indoor units compatible for the above unit as per the capacities
OD89647/2022-2023:Supply indoor units Refnets (Indoor)compatible for the above VRF unit as per capacities
OD89648/2022-2023:Supply indoor Refnets (outdoor)compatible for the above VRF unit as per the capacities
OD89649/2022-2023:Supply, installation, testing and commissioning of insulated condensate drain piping out of PVC- 6Kgf/cm2 pipes complete with hangers/supports/clamps/Clips and all ,fittings etc. and insulated with 13mm thick nitrile rubber sleeves and joints sealed with 50 mm black PVC tapes-25 mm dia
OD89650/2022-2023:Supply and laying of refrigerent copper piping with 18G HD copper pipes ,insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supports 6.35mm OD.
OD89651/2022-2023: Supply and laying of refrigerent copper piping with 18G HD copper pipes ,insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supports 9.53mm OD.
OD89652/2022-2023: Supply and laying of refrigerent copper piping with 18G HD copper pipes ,insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supports 12.7mm OD.
OD89653/2022-2023:Supply and laying of refrigerent copper piping with 18G HD copper pipes ,insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supports 15.9mm OD.
OD89654/2022-2023:Supply and laying of refrigerent copper piping with 18G HD copper pipes ,insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supports 19.1mm OD.
OD89655/2022-2023:Supply and laying of refrigerent copper piping with 18G HD copper pipes ,insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supports 41.3mm OD
OD89656/2022-2023: Supply and fixing of weather proof coating for all inside running Refrigerant piping with glass cloth & foaster painting to be provided for all running copper pipes.
OD89659/2022-2023: Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC shielded communication cabling between VRV/VRF indoor and outdoor units 650/1100 V grade copper conductor flexible cables in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 1.50 sq mm
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
OD89660/2022-2023:Supply, installation, testing and commissioning of PVC piping 6Kgf/cm2 pipes complete with hangers/supports/clamps/Clips and all ,fittings etc for the purpose of running refrigerant piping--75 mm dia
OD89661/2022-2023:Supply, installation, testing and commissioning of PVC piping 6Kgf/cm2 pipes complete with hangers/supports/clamps/Clips and all ,fittings etc for the purpose of running refrigerant piping-100 mm dia
OD89662/2022-2023:Supply, installation, testing and commissioning of PVC piping 6Kgf/cm2 pipes complete with hangers/supports/clamps/Clips and all ,fittings etc for the purpose of running refrigerant piping-150 mm dia
PIONEER COOLTECH
Bidder Name
Maxsel Agencies
PIONEER COOLTECH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_725907.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .