Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹2.2 Cr
EMD Value
₹2.2 L
Closing Date
3 Dec 2026, 5:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Chief Officer,Sachin Notified Area
Construction of RCC intake structure Near Reservoir at Notified Area GIDC Sachin 2026-27
366547
05 of 2026-27(Serial No. 4)
Open
Civil Works - Water Works
Works
Surat
16 documents required · 16 mandatory
₹4,248
Chief Officer, Sachin Notified Area
₹2.2 L
19 Nov 2026
19 Nov 2026
19 Nov 2026
3 Dec 2026
19 Nov 2026
120 days
NAME OF WORK: - Construction of RCC Intake structure near Reservoir Area GIDC
Sachin 2026-27.
Description Unit Quantity Rate Amount Rs.
1 Excavation for foundation up to 1.5 m depth including
sorting out and stacking of useful materials and
disposing off the excavated stuff up to within GIDC
Area lead. (B) Dense or Hard soil (A) up to 1.50 m depth
- Dense or Hard soil. Cu.mt 743.00 157.52
2 Excavation for foundation for depth from 1.5 m to
m including sorting out and stacking of useful materials
and disposing off the excavated stuff up to within GIDC
Area lead. (B) Dense or Hard soil (B) 1.50 m to 3.00 m
depth - Dense or Hard soil Cu.mt 712.00 170.87
3 Excavation for foundation for depth from 3.0 m to
m including sorting out and stacking of useful materials
and disposing off the excavated stuff up to within GIDC
Area lead. (B) Dense or Hard soil (C) 3.00 m to 5.00 m
depth - Dense or Hard soil Cu.mt 577.00 184.77
4 Extra for additional depth more than 5.0 m for
excavation for foundation including sorting out and
stacking of useful materials and disposing off the
excavated stuff up to within GIDC Area lead.(B) Dense
or Hard soil (D) Extra Depth after 5.0 m - Dense or Hard
Soil Cu.mt 248.00 206.95
5 Providing and casting in situ C.C. in grade M-15 (approx.
corresp. to prop. 1:2:4) (proportions as per mix design
or as per Table 9 of IS456 2000 in masses by weigh
batching ) using granite, quartzite trap metal of size
mm to 20 mm for RCC work, including scaffolding
centering, form work, needle vibrated consolidation,
curing comp. up to 6 meter depth or height (excluding
cost of reinforcement and neat finishing) with
centering and shuttering/deshuttering etc. comp. for
structure for other than water retaining.
Note: A quantity of more than 3 cu.m. of concrete RMC
shall be allowed. Cu.mt 39.00 4,906.00
6 Providing and cast in situ C.C. in grade M-30
proportions of ingredients as per mix design by weigh
batching using granite, quartzite trap metal of size
mm to 20 mm and or 6 mm to 12 mm including
scaffolding centering formwork, needle vibrated
consolidation, curing and hydraulic testing etc.
complete (excluding cost of reinforcement) with
centering and shuttering/deshuttering etc. comp. up to
6 meter height/depth Av. G.L.for all water retaining
Note: A quantity of more than 3 cu.m. of concrete RMC
shall be allowed. (From Lvl -06.575 to +12.00 NGL) &
(+12.00 to +18.00 m) 1. Flat Bottom Slab (Base Rafts)
with shuttering Cu.mt 223.00 8,213.00
7 2. Beams/ ring beams/ girders Cu.mt 87.00 8,486.00
8 3. Vertical Wall Above 25 cm Cu.mt 236.00 8,083.00
9 4. Columns Cu.mt 63.00 9,317.00
10 Extra for raising / lowering of C.C. for every additional
3 meter of part thereof in all RCC items of reservoirs
or water retaining structures. 6.00 to 9.00 Mt. ht.
(From Lvl +18.00 to +21.00 Mt) 1. Flat Bottom Slab
(Base Rafts) with shuttering Cu.mt 28.00 8,418.00
11 2. Beams/ ring beams/ girders Cu.mt 31.00 8,691.00
12 3. Vertical Wall Above 25 cm Cu.mt 31.00 8,288.00
13 4. Columns Cu.mt 15.00 9,522.00
14 Supply cutting, bending, binding and placing in position
steel as per plan and design and as per ISS
including cost of steel and binding wire for reservoirs /
structures only including lift up to 6-meter height or
depth below G.L. for all diameters. Do-CRS steel all
diameter Fe 500/550 D grade confirming to relevant
I.S. Up to 6 M height/depth (Upto +18 m Lvl.) MT 78.00 78,577.00
15 Extra for raising steel bars for every additional height
of 3 meters or part thereof. 6 to 9 Mt. ht. (From Lvl
16 Providing fusion bonded Epoxy coating not less than
175 micron thickness and up to 300 micron to
reinforcement bars as per IS-13620-1993/ASTM-775 M
including testing of coating at plant and all taxes (A)
10mm to 16mm dia bar M.T. 92.00 10,162.62
17 Filling available excavated earth (excluding rock) in
trenches. plinth, sides of foundations etc. in layers not
exceeding 20 cm. in depth consolidating each
deposited layer by ramming and watering. Cu.mt 1142.00 136.92
18 Providing and fixing watertight construction or
expansion joints. 150 mm wide thin ribbed PVC. R.Mt. 831.00 330.00
19 Brick work using common burnt clay building bricks
having crushing strength not less than 35 kg./Sq.Cm. in
foundation and plinth in Cement Mortar 1:6 (1- Cement
: 6 -fine sand) (B) Conventional Masonry Cu.mt 91.00 4,214.33
20 Cement plaster 20 mm thick in C.M. 1:2 using water
proofing compound of approved quality including
finishing etc. complete.
21 Providing 15mm thick cement plaster in single coat on
Rough (Similar) side of single or half brick walls for
interior plastering upto floor two level and finished
even and smooth in (ii) Cement mortar 1:4 (1-cement
22 Providing and laying polished kota stone slab flooring
over 20 mm (Average) thick base of cement mortar 1:6
(1 cement: 6 coarse sand) or L.M. 1.1.5 (1-Lime putty
:1.5-coarse sand sand) laid over and joined with grey
cement slurry mixed with pigment to match the shade
of slab including rubbing and polishing etc. complete.
23 Providing and laying broken china mosaic flooring for
terrace using 12 mm to 20 mm broken piece of glazed
tiles to be laid over cement mortar 1:3 to plain or slope
and to be tempered to bring mortar creme out up to
surface using white cement including rounding off
junctions and extending them up to 15 cm along the
wall, clearing with water and oxalic acid etc. as
directed. Pump House terrace Sq.M. 178.00 779.70
24 Providing and laying cement concrete flooring 1:2:4 (1-
cement : 2-coarse sand : 4-graded stone aggregate
20mm nominal size) laid in one layer and finished with
a floating coat of neat cement. (A) 40mm thick.
IPS Flooring Sq.M. 141.00 290.63
25 Extra for providing and mixing water proofing material Litres
in Cement concrete in mix proportion recommended or Kg
by the manufacturers. @ 0.50 kg or 0.50 litter water per
proofing compund per 1 bag of cement. Quintal
Cement 36.00 49.16
26 Providing and fixing rolling shutters of approved make
made of 80 mm wide M.S. laths inter-locked together
through their entire length and jointed together at the
ends by end locks mounted on specially designed pipe
shaft with bracket plates, guide channels and
arrangements for inside and outside locking with push-
pull operation including the cost of hood cover and
spring etc. complete.(A) Shutters having width below
3.5 M. Rolling Shutter (Front) Sq.M. 27.00 3,554.40
27 Providing and fixing 35 mm thick shutter for Doors,
windows and clerestory windows including Indian teak
wood frames 10 cm x 7 cm. size including black
enamelled iron oxidixed fixtures and fastening
including primer coat of approved quality and two
coats of oil painting etc complete. II) fully panelled
Doors Sq.M. 6.00 5,338.30
28 Providing and fixing extruded aluminum window
having extruded aluminum Colour Powder Coated
section frame main outer size 127mm x 38.10mm x
1.35mm ,@ Wt.1.384 Kg/mt, horizontal Four track
member size 122.20mm x 31.75mm x 1.10mm @ Wt.
1.205 Kg/mt,vertical member of size 122.20mm x
31.75mm x 1.50mm ,@ Wt. 1.398 Kg/mt with sliding
shutters of horizontal member size 40mm x 18mm x
1.29mm @ wt.of 0.456Kg/mt,vertical member of size
40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt,@ with
5 mm thick transparent bronze colour tinted float glass
with powder coated aluminum fittings and fixtures and
transparent silicon sealant glass fixing to frame as per
details etc complete for window. Sq.M. 24.00 2,140.33
29 Providing and fixing standared extruded of alluminium
section of size 63mm x 38.10mm x 1.2mm @ Wt.
Kg/mt with colour anodized alluminium frame for
ventilation with 5 mm thick frosted glass as details etc
complete for Ventilation. Sq.M. 15.00 1,175.56
30 Applying two coats of putty & two coats of primer of
approved brand and manufacture on new wall surface
to give an even shade including thoroughly brushing
the surface free from mortar dropping and other
foreign matter and sand papered smooth. On Inside
surface Sq.M. 592.00 40.59
31 Wall painting (two coats) with plastic emulsion paint of
approved brand and manufacture on undercoated wall
surface to give an even shade including thoroughly
brushing the surface free from mortar dropping and
other foreign matter and sand papered smooth. Inside
Painting Sq.M. 592.00 84.37
32 Finishing wall with weather proof exterior emulsion
paint on wall surface (two coats) to give an required
shape even shade after thoroughly brushing the
surface to remove all dirt, and remains of loose
powdered material etc. complete. Outside Painting Sq.M. 2108.00 120.26
33 Providing and fixing M.S. Grills of required pattern to
wooden frames of windows etc. with MS flats at
required spacing and frame around square or round
bars with round headed bolts and nuts or by screw (A)
plain grill Kg 776.00 109.24
34 Providing and fixing post and pipe railing as per
detailed drawing including 3 coats of painting to steel
works complete. Staircase Railing (S.S.) Rmt. 80.00 1,213.86
35 Steel work, welded in built up sections framed work
including cutting, hoisting, fixing in position and
applying a priming coat of red lead paint. (A)In beams
and joists, channels angles Tees, flats, with connecting
plates or angle cleats as in main and cross beams. Hip
and jack rafters, purlins conneted to common rafters
and the like Qt 23.00 9,108.48
36 Providing fabricating and fixing / installing C.I. gates of
size as per enclosed drawings with operating handle
etc. for by pass arrangement With ISI Mark KG 1600.00 82.00
37 Water Level Indicator/ Depth Gauge
Providing and fixing Water Level Indicator or depth
gauge painted on TW plank 25 mm/MS plate 4 mm
thick float, level indicator sliding wire on standard
pulleys incl. necessary arrangement to prevent the
swinging etc. complete with calibration up to 5 mt
height. No. 1.00 5,520.00
38 Ultrasonic Type Level Transmitter with Remote Display
: Design, Supply, Installation, Testing and
Commissioning of Non Contact Ultrasonic Type Level
Transmitter with Remote Display. Sensor: The sensor
should be non contact type, field mounting type,
housing shall have minimum IP65 protection, PP/ PVC
Sensor MOC, with sensor to transmitter cable. Remote
Indicator cum Transmitter: Microprocessor based
indicator with LED / LCD digital display,panel/ wall
mounting type, power supply shall be 110-240 Vac or
15 to 36 Vdc, 50 Hz ± 10 %. Accessories: Mounting
bracket, nut, bolts etc as per system requirement and No. 1.00 59,436.00
Hook up diagram of the Instruments. Level Transmitter
shall be suitable for following Range. ii) 0 to 10 Meter
39 Providing, laying and jointing in true line and level
diameter U.P.V.C (Type B) conforming to IS 13592-1992
with one end plain and other end socketed with rubber
ring, & fittings conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe
shall be jointed with each other with rubber lubricant,
pipe shall be fixed on wall using of PVC clamp of the
size 110 mm diameter x 149 mm length x 145 mm heigh
at every 2000 mm center to center or shall be
concealed in walls as directed including necessary
fittings such as bends, shoes etc. including testing of
pipes and joints and jointed with adhesive solvent
cement including cost of all materials. Rmt. 10.00 878.57
40 (a) M.S. Ladder (without safety cage) Providing and
fixing 50 cm wide M.S. ladder fabricated from M.S. flats
10 mm x 60 mm with 20 mm dia steel bar steps, @
cm c/c. The include stays of 10 mm x 50 mm flats fixed
at 3 meter c/c. with welding anchroing and 3 coat of
anticorrosive paint.
41 (a) Note: For M.S. Ladder (with Safty cage) (a) plus Rs.
67 per Kg of additional structural steel consumed fro
safety cage arrangement Kg 226.00 67.00
42 Painting letters
Painting letters for "Capacity of tank" the size of letters
will be 45 cm height and 50 mm width. Painting Letters
43 Supply, installation, testing & commissioning single
girder type fully electrically operated EOT crane with
electrically operated hoist, class II duty, geared
travelling trolley with seven meter lift complete with
long travel rail track (40 mm sq. bar), moving or cross
girder, all three motions electrically operated by
suitable rating motor IP 54, control panel & down
pendant control block, brake, safety device, cables
form motor to starter panel & other required
accessories & tested as per IS Specifications. Capacity.
3 Ton, Span 3m -9m, Long travel 30mtr, Lift 6m -10m Set 2.00 5,30,250.00
44 Providing and supplying ISI standard R.C.C pipes (of
Sulphate Resisting Cement) in standard lengths of
following class and diameter suitable for either collar
joints or rubber ring joints including all taxes.
Insurance, transportation, freight charges, octroi,
inspection charges, loading, unloading, conveyance to
department stores, stacking etc.Note: One collar
should be supplied with each full length plain ended
RCC pipe, cost included in rates below. one rubber ring
should be supplied with each full length socketed pipe,
cost included in rate below.Class NP3 Test Pressure
kg/sq.cm1000 mm Dia. Rmt. 100.00 5,076.00
45 Manufacture, Supply & Delivery of Electric Resistance
welded (Up to 400mm)/ Submerged Arc welded (Above Rmt. 12.00 25,532.00
400mm) M.S.Pipe having beveled ends plate or coil
conforming to IS-3589-2001 or its latest
revision/amendment for following thickness outside
diameter at store or site anywhere in Gujarat State
including all taxes, insurance, transportation, freight
charges, octroi, inspection charges, loading, unloading
conveyance to Department stores, stacking etc. all
complete. (Rate for MS pipe based on the ex. works
price of HR coil as Rs 58500.00 per MT without GST
(Above 3.15mm to 10mm) & Rs 59000 per MT without
GST (Above 10mm) as on Jan-23. (WPI index of H.R coil
of Dec-22 is 144) I/S Solvent free liquid epoxy lining
(406 Micron) + O/S 3 LPE coated MS Pipe
1219 mm dia. & 10.0 mm thick Carrying Pipe
46 219 mm dia. & 6.3 mm thick Air Vent Pipe
47 Providing & supplying ISI mark C.I.D/F sluice valves, as per IS
14846 (latest edition) of following class and diameter
including all taxes, insurance, transportation, freight
charges, octroi, inspection charges, loading, unloading,
conveyance to departmental stores, stacking etc. complete.
PN 1.0 with hand wheel / cap operated
(Alt-1 type long Body) 1200 mm dia No. 2.00 11,26,339.00
48 Lowering, laying and jointing R.C.C pipes in C.M. 1:1 1/2 of
following diameter in proper position, grade and alignment
at all level as directed by Engineer in charge including
conveyance from stores to site of work, labour, giving
hydraulic testing as per ISI code. Class NP3 Test Pressure
49 Lowering, laying, jointing & welding in position to correct line
& level M.S. Pipe with outerside 3 LPE coating & inside
solvent free liquid epoxy lining on pedestal or chairs upon
prepared formation or prepared bedding in trenches the
rates include conveyance from store to site of work loading,
unloading, heat shrink sleev jointing hydrotesting etc.
1219 mm dia. & 10.0 mm thick Carrying Pipe Rmt. 12.00 1,550.00
50 219 mm dia. & 6.3 mm thick Air Vent Pipe Rmt. 78.00 293.00
51 Lowering, laying and jointing in position following C.I. / D/F
Reflux valves, Butterfly valves, Sluice valves and Air valves
including cost of all labor, jointing materials, including nut
bolts and giving satisfactory hydraulic testing etc. complete.
52 Construction of valve chamber in brick locally available in CM
1:6 Foundation concrete 150 mm thick in CC 1:4:8 of trap
metal size 25mm to 40 mm thick, inside cement plaster in
C.M 1:3 &cement pointing outside in C.M 1:3 and top cover
or precast RCC slab 100 mm thick (with key hole in two parts,
each with handles or MS Bar etc. Comp. as given size) Up to
1 Mt depth from GL to pipe invert level including complete
civil works but excl. cost of excavation & refilling. With cast
in situ RCC slab in one single piece with of C.I.M.H Frame &
cover. (excl. cost of C.I.M.H Frame & cover) with 23 mm thick
brick masonry wall in C.M.1 :
a) Size of Chamber 1.30 m x 1.30 m and 1.0 mt. deep No. 4.00 11,351.00
Total Amount in Rs.
Total Amount in Rs.
I / We agree to carry out the above work at ____________ % above the estimated rate ((In Words)
_________________________________________________) percentage above the Estimated Tender Rate.
I / We agree to carry out the above work at ____________ % below the estimated rate ((In Words)
_________________________________________________) percentage below the Estimated Tender Rate.
Estimated Amount Estimated Amount
Put to Tender Rs. 2,23,10,891.03 Put to Tender Rs
Add % Above Rs. _____________ Deduct% Below Rs_________
Net Amount Rs.____________ Net Amount Rs._________
Net In Figure Rs. _____________ Net in Figure Rs_________
I / We have read the Condition mentioned in this tender and agree to abide by the same.
Note: The Unit rates specified for various items to be executed as per Schedule "B" attached with the Price Bid are excluding GST but inclusive all labors,
materials, testing charges, equipment’s, all incidental charges involving in the work and as specified in the Mode of measurement & payment of detailed
specifications of items incl. all taxes, royalty, octroi transportation cost etc. all as applicable presently as to be enforced for future by any / all
including Central/State Government & Statutory bodies from time to time
Signature of Contractor with Seal Sachin Notified Area,
G.I.D.C.-SACHIN
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender Documents.pdf
Scheudl-B.pdf
B1 Agreement .pdf
1 GAD_INTAKE STRUCTURE.pdf
2 GAD FOR PROPOSED SLUICE GATE and MS BRIDGE EXISTING OUTLET.pdf
3. TYPICAL DETAILS OF OVERFLOW STRUCTURE.pdf
4 LAYOUT PLAN FOR RASING HEIGHT OF EXISTING INTAKE STRUCTURE.pdf
5.GENERAL ARR.DRAW SHOWNING THE DETAILS D.pdf
Corri 01.pdf
Corri 02.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .