Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹7.9 L+₹48,360 (6.54%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO L2 | |
| 3 | L3₹8.2 L+₹81,340 (11.0%)Rejected-Finance 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L3 | Rejected-Finance REJECTED DUE TO L3 | |
| 4 | L4₹8.3 L+₹86,090 (11.6%)Rejected-Finance | L4 | Rejected-Finance REJECTED DUE TO L4 | |
| 5 | L5₹8.3 L+₹89,750 (12.1%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L5 | Rejected-Finance REJECTED DUE TO L5 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
22 Aug 2020, 6:00 pmClosed
GE SHIKARGARH
Military Engineer Services, Garrison Engineer, Shikargarh, Near ASC Supply Depot, Ratanada Jodhpur-342011
REPAIR AND REPLACEMENT OF INTERNAL ELECTRIFICATION IN OFFICER MD ACCN AT SHIKARGARH UNDER GE SHIKARGARH IN ARMY AREA JODHPUR
2020_MES_365323_2
8648/E8 42
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SHIKARGARH
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE SHIKARGARH
₹24,000
Yes
3 Sept 2020
7 Aug 2020
24 Aug 2020
7 Aug 2020
22 Aug 2020
7 Aug 2020
Amount
Taking down carefully existing unserviceable aluminum/copper point wiring of any description & in any position with and including taking out and removing existing wooden battens/conduits /casing caping fixed on surface and all fittings including unserviceable sunken/surface boxes & terminal/junction boxes of any description, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc including taking out and removing serviceable fittings/fixtures for reuse at site or depositing to MES store and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed
M&L for point wiring for one light/fan/bell point controlled by one one way switch complete with multistrnaded copper conductor 1.5 sqmm size PVC insulated FRLS unsheathed cable 1100 volt grade, conforming IS 694 & color code in PVC casing caping suitable capacity (minimum size 25 mm) in pressed steel terminal boxes of required size not less than 1.6 mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core solid conductor copper 1.5 sqmm size solid PVC insulated unshethed cable as earth wire to common earth and connected to earth dolly drawn in same casing capping complete all as specified. Make of wire : Finolex/Havells/KEI/Polycab, Make of PVC casing caping : Finolex/Precision/Polycab/Presto-Plast.
ditto but for One 3 Pin 5 Amps socket outlet on same board
ditto but for One 3 Pin 5 Amps socket outlet on independent board.
ditto but for One light point controlled by two,two way switches
All as per item No 2 above but using 4.0 Sqmm PVC insulated, unsheathed cable for one 3 Pin socket outlet 15 Amps on independent board.
Supply and fixing switch piano, flush type ,single pole one way 5/6 Amps 240 Volts, AC circuit complete all as specified and directed. Make : Anchor Penta / Cona /SSK
Supply and fixing switch piano, flush type ,single pole two way 5/6 Amps 240 Volts, AC circuit complete all as specified and directed. Make : Anchor Penta / Cona /SSK
Supply and fixing switch piano, flush type ,single pole one way 15/16 Amps 240 Volts, AC circuit complete all as specified and directed. Make : Anchor Penta / Cona /SSK
S/F Socket outlet 2 in 1, 3 pin, 5A universal flush shuttered type ISI mark complete all as specified and directed. Make : Anchor Penta / Cona /SSK
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush shuttered type ISI mark complete all as specified and directed. Make : Anchor Penta / Cona /SSK
S&F Bell Switch 5 Amps flush type Single pole 240 volts ISI marked complete all as specified and directed. Make : Anchor Penta / Cona /SSK
S/F ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and directed. Make : Anchor Penta / Cona /SSK
Supply and fix door Bell Ding Dong type complete all as specified and directed. Make : Anchor Penta /Cona/SSK.
S&F fan regulator electronic, deluxe rotary step type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified and directed. Make : Anchor Penta /Cona/SSK.
M&L for Sub main wiring with PVC insulated but unsheathed 2x6 sqmm multi stranded copper conductor cable passing through and incl PVC casing caping on wall (by means of screw incl making good existing ) ISI marked and casing caping accessries fixed on surface of wall, ceiling etc, making good the disturbed surface with and incl 1x6 sqmm single core copper conductor cable PVC insulated and unsheathed as earth wire (green colour) including taking down old one. Note:- Two run of 6 Sq.mm. and one run of 6 Sq.mm (earth wire) cable incuding one run of PVC casing caping will be measured as one length including making good the disturbed surfaces. Make of wire : Finolex/Havells/KEI/Polycab, Make of PVC casing caping : Finolex/Precision/Polycab/Presto-Plast
All as above item No 13 but using 2x4 Sqmm cable single core copper with 4 Sqmm copper conductor as earth lead. Make of wire : Finolex/Havells/KEI/Polycab, Make of PVC casing caping : Finolex/Precision/Polycab/Presto-Plast.
All as above item No 13 but using 3x10 Sqmm cable single core copper with 1x10 Sqmm copper conductor as earth lead. Make of wire : Finolex/Havells/KEI/Policab, Make of PVC casing caping : Finolex/Precision/Polycab/Presto-Plast.
S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified Make:Legrand cat No 5078 11 or equivalent ABB/Scheinder.
Fixing only LED light 22/20/18 watt including taking down old one all as specified and directed. Note : LED lights shall be issued under Sch 'B' free for fixing only
Fixing only LED light 10/12 watt including taking down old one all as specified and directed. Note : LED lights shall be issued under Sch 'B' free for fixing only
S&F 05 Watt LED Batten with extruded aluminium housing in 1 Feet Length with in Built LED strip, LED shall be having 400 system lumens, 3 stage CCCV driver with voltage range of 150-270 AC and DC output operating voltage of driver should be complied to SELV norms not exceeding 72 DC only including taking down old one complete all as specified and directed. Make :- CG / Wipro / Philips.
Taking down carefully UNSV main switch and DB's including MCBs of any size, make, type and capacity removing materials to store for keeping in safe custody for re-use at site/Sch of credit and making good disturbed surface of walls, floors, etc.all as directed.
S&F sheet metal enclosure triple pole and neutral 415 Volts 4 way (TPN) with 100 Amps rated coper busbar and MCB for double door having IP 43 protection flush mounting MCB shall be measured separately complete all as specified and directed Make: Legrand Cat No- 5076 70 or equivalent ABB/ Scheinder /L&T.
S&F Distribution boards 415 V ,8 way SPN with 100 Amps rated coper busbar and MCB for double door having IP 43 protection flush mounting MCB shall be measured separately complete all as specified and directed . Cat No- 507611 Make: Legrand or equivalent ABB/Scheinder/L&T.
S&F MCB SP 6 to 32 Amps 10 KA, 240 V, C curve complete all as specified and directed . Make: Legrand Cat No 4085 90 or equivalent ABB/Scheinder/L&T.
S&F MCB SPN 32 amps 10 KA, 240 V, C curve complete all as specified and directed . Make: Legrand Cat No 4086 17 or equivalent ABB/Scheinder/L&T.
S&F MCB TPN 63 amps 10 KA, 415 V,C curve complete all as specified and directed . Make: Legrand Cat No 4086 83 or equivalent ABB/Scheinder/L&T.
S & F of MCCB 3 Pole 100 Amps 36 KA All as directed by EIC. Make: Legrand or equivalent ABB/Scheinder/L&T.
S& F sheet metal enclosure triple pole and neutral 415 Volts 4 way (TPN) with 250 Amps rated coper busbar with MCCB 160 A, TPN 415 V as incommer with door cover having IP 43 protection flush mounting MCB shall be measured separately complete all as specified and directed . Make: Legrand Cat No- 5077 45 or equivalent ABB/Scheinder/L&T.
Earthing complete with GI steel earth plate eletrode 60 cm X 60 cm X 6.0 mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metres below level ground,connected to Gl iron or steel earth wire 4 mm dia (8 SWG) by means of nuts,bolts checks nuts and washers made of Gl iron or steel earth wire protected by Gl iron pipe 15 mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6:) type C1, pre-cast RCC coverslab 30 cm X30 cm X 10 cm with one lifting handle made of 8 mm dia ms bar funnel wire mesh,20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges,necessary excavation and earth work in any type of soil complete all as shownin electrical plate No 3 of MES schedule part-I and testing after completion.
M/L for cutting of PCC/Kota stone floor/plinth /wall/road etc for insertion of GI pipe for protection of GI wire of earthing including making good disturbed surface.
Taking down existing unserviceable static meter and Supply and fix AC single phase static energy meter of accuracy class 1.0,240V, 50hZ, withBacklit LCD Display of rating 10-60A (Measures & display KWH,V,I,KW,PF.last month history of KWH & MD in KW) with special features like TOD, Tamper logging,optical communication port and display in absence of power of Make HPL Cat Part No-SPPL152110000ME03 or equivalent in L&T /Asian and all as directed at site. Note:- Unserviceable meter will be deposted to MES store yard.
Fixing only LED Street light 45/60/90 watt including taking down old one complete all as specified and directed by Engr in Charge. Note : LED lights shall be issued under Sch 'B' free for fixing only
S&F of GI pipe bracket 40 mm dia light grade pipe 1.5 mtr long bent to shape as directed including nut,bolts,washers and clamp etc and necessary 1.5 Sqmm 3 core sheathed copper PVC cable for connection including taking down old one complete all as specified and directed by Engr in Charge.
Shri Ram Traders Co
mahalaxmi enterprises
M/s R K Enterprises
M/s Shiv Builder and Suppliers
vinayandsons
Siddharth Constructions
KARNI CONSTRUCTION COMPANY
M/S JAGDAMBA ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .