| 1 | L1₹6.4 LAccepted-AOC C O M KHARKARANG LUMJINGSUK BLOCK A MADANRTING SHILLONG 793021 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793021 | L1 | Accepted-AOC Being L1 Bid | |
| 2 | L2₹8.2 L+₹1.3 L (18.2%)Rejected-Finance PO VIKRAMKHAND ROAD LANE NO 05 HOUSE NO 16 ASSAM 788007 | CACHAR | ASSAM | 788007 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹8.2 L+₹1.3 L (18.3%)Rejected-Finance C O GIVEN GOD NONGTDAU ARBUTHNOT ROAD NONGRIMMAW LAITUMKHRAH SHILLONG PIN 793011 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793011 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹8.4 L+₹1.5 L (22.0%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | Rejected-Technical RONGMEN BLOCK IV NEAR UMROI MILITARY STATION P O BARAPANI SHILLONG 793103 | SHILLONG | RI BHOI | MEGHALAYA | 793103 | - | Rejected-Technical Rejected being NO remarks in WLR |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
17 Mar 2023, 6:00 pmClosed
GE
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
REPAIRS MAINTENANCE OF AA ASSETS BR SERVICES AND WIRING AT KUMBHIGRAM UNDER GE SILCHAR
2023_MES_581628_1
8775/E8
Open Tender
Civil Works
Item Rate
120 days
KUMBHIGRAM
Please refer Tender documents
7 documents required · 7 mandatory
₹500
GE Silchar
₹12,000
6 Apr 2023
17 Feb 2023
20 Mar 2023
17 Feb 2023
17 Mar 2023
4 Mar 2023
24 Feb 2023 - 28 Feb 2023
Amount
B/R WORKS
Taking down chowkats or frames exceeding 1sqm and not exceeding 2sqm each with shutters (without taking off shutters from the frame) and disposing off
Taking down chowkats or frames exceeding 2sqm but not exceeding 4sqm each but with shutters (without taking off shutters from the frame) and disposing off
Dismantling mild steel work or wraught iron of any description and in any position complete all as specified and as directed
Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc. complete all as specified and as directed
Dismantling rain water pipe and sewage line pipe of any type and any size including fitting from any location / position complete all as specified and as directed
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as in cover slabs, removing debris from site and making good the disturbed surfaces / portions in existing specifications complete all as specified and as directed
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed
Taking down cement or cement/lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed
Taking up or down 15mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed
Taking up or down 20mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed
Cutting chases, pinning in brick walls and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10cm in girth complete all as specified and as directed
M&L for loose filling with broken brick aggregates of gauge 40 to 80mm in soakage pits, soakage wells, etc. complete all as specified and as directed
M&L for mild steel TMT bars grade Fe-500D, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
M&L for mild steel TMT bars grade Fe-500D, 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed
M&L for rendering 10mm thick in cement mortar (1:6) on other than fair surfaces of PCC block / brick masonry wall / concrete surfaces, etc. finished fair and even without using extra cement complete all as specified and as directed
M&L rendering 15mm thick, in cement mortar (1:4) on walls / concrete surfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished fair and even without using extra cement complete all as specified and as directed Note: WPC will be measured and paid separately under respective item herein
Supply only integral water proofing compound all as specified
M&L for plain cement concrete 1:3:6 (type C-1) using 20mm graded stone aggregate as in beds of drains, surface channels, foundations of manholes, etc. complete all as specified and as directed
M&L for 75mm thick PCC 1:3:6, type C-2, using 40mm graded aggregates as in plinth protection, sub base of floor, etc. surface finished even & smooth without using extra cement complete all as specified and as directed
M&L for 75mm thick PCC 1:2:4, type B-2, using 40mm graded aggregates as base of floor, etc. surface finished even & fair without using extra cement complete all as specified and as directed
M&L for precast RCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregates as in cover slab for man holes, drains, soak wells, and similar articles, set in CM 1:4 with plain faces including necessary formwork and chamfering, weathering, throating, etc. complete all as specified and as directed
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directed Note: Inner girth shall only be measured
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.06sqm but not exceeding 0.11sqm each, 7 to 8mm thick of superior quality as in floors, etc. jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles over and including 15mm thick screed bed in CM (1:6) (rate shall be included) complete all as specified and as directed
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.11sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality as in floors, etc. jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles over and including 15mm thick screed bed in CM (1:6) (rate shall be included) complete all as specified and as directed
M&L for pre-polished chequered cement concrete tiles, 25mm thick, area of each tile exceeding 0.06sqm but not exceeding 0.11sqm in floors, set, jointed and pointed with neat cement slurry with white cement and pigment to match shade of tile, laid over and including 20mm thick screed bed or bedding layer in cement mortar (1:6) including dismantling of old unserviceable chequered cement concrete tiling complete all as specified and as directed
S&F solid PVC door frame of size 50x47mm made out of 5mm thick plain / printed coloured PVC sheet (as approved) reinforced with MS square tube all as per specifications and drawing given in SSR Part-I 2009 all as per manufacturer's instructions and making good the disturbed surfaces complete all as specified and as directed
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified and as directed
S&F factory fabricated flush shutters, 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, smooth finish with lipping of teak wood on edges complete all as specified and as directed
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
S&F 3mm thick sheet glass ordinary quality and glazing with oil putting square not exceeding 0.5sqm in each pane complete all as specified and as directed
S&F 3mm thick sheet glass ordinary quality and glazing with oil putting including hacking out old broken glass (any thickness, size quality or description) from wooden frame or stone, concrete or brick surrounds, glazed with putty or fixed with beads square not exceeding 0.5sqm in each pane complete all as specified and as directed
S&F 300mm aluminium anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed
S&F 150mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed
S&F 200mm long aluminum anodised barrel tower bolt of extruded section complete all as specified and as directed
S&F 100mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed
S&F 150mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed
S&F 100mm MS butt hinges, medium weight, cold rolled complete all as specified and as directed
S&F in repairs door closer hydraulically regulated, designation No. 3 universal type of aluminium (extruded section body) of weight 61 to 80kg, suitable for door shutters of 851-1000mm in width complete all as specified and as directed
S&F in repairs 25mm dia fancy type chromium plated (tint as approved) MS curtain / drapery rods, etc. of rod wall thickness 1mm (min), including pair of brackets, holders with funnel at ends complete all as specified and as directed
M&L for framed works conforming to Fe 410-W (grade E-250) quality-A as in doors or windows of angle or other section with gusset plates, rails, braces, etc. drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and as directed
Supplying, hoisting, fixing and connecting up rotational moulded polythylene water storage tanks (cylindrical vertical with closed top), 500litres capacity, hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed
S&F in repairs for GI wire netting 0.71mm dia and 12mm mesh fixed to wood or metal studding joints, etc. in walls, ceiling stanchion, beams, etc. including all laps, cutting and wastes, etc. complete all as specified and as directed
M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
M&L for preparing of old treated / untreated steel surfaces of any description over 10cm in width or girth by scrapping of surfaces and applying one coat of synthetic enamel paint (tint as approved) complete all as specified and as directed
M&L for preparing of new wood / wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, tint as approved complete all as specified and as directed
M&L for preparing of old treated / untreated wood / wood based surfaces of any description over 10cm in width or girth by scrapping of surfaces and applying one coat of synthetic enamel paint (tint as approved) complete all as specified and as directed
M&L for preparation of new masonry / concrete wall / ceiling surfaces and applying two coats of oil emulsion distemper over a coat of wall primer including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed
M&L for preparation of old decorated plastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc. and applying one coat of oil emulsion distemper including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed
M&L for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistant, dirt resistant, exterior paint of approved shade (company depot tinted) with silicon additives @1.43litre/10sqm over and including a priming coat of exterior primer applied @0.90 litre/10sqm over new surfaces of brickwork,concrete, etc. including all necessary staging, scaffolding, etc.required complete all as specified as as directed
M&L for preparation of old decorated plastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc. and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistant, dirt resistant, exterior paint of approved shade (company depot tinted) with silicon additives @1.43litre/10sqm over and including a priming coat of exterior primer applied @0.90 litre/10sqm including all necessary staging, scaffolding, etc.required complete all as specified as as directed
M&L for writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30cm high in approved tint at any locations / positions by using synthetic enamel paint (of approved tint) complete all as specified and as directed
M&L for writing stops, commas, short lines, dashes, hyphens, brackets, etc. by using synthetic enamel paint (of approved tint) complete all as specified and as directed
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
S&F 0.63mm thick corrugated galvanised steel sheetings, with grade of zinc coating 275gm/sqm and with two corrugation side lap fixed with ‘L’ type or ‘J’ type cranked hook bolts, nuts, washers, etc. as in roof, wall, etc. complete all as specified and as directed
--ditto-- all as per item No. 61 hereinabove but except sheets
S&F 0.63mm thick plain galvanised steel sheetings, with grade of zinc coating 275gm/sqm, fixed with cranked hook bolts, nuts, washers, etc. as in ridges, hips, valley gutters, drip and straight flashings (length or girth as fixed) complete all as specified and as directed
Fixing only steel water tubing, medium grade, galvanised with screwed and socketed joints, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed for the following bores: Note: Serviceable tubings obtained from dismantling herein before will be reused under this item
15mm bore
20mm bore
S&F steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed of the following bores:
15mm bore
20mm bore
S&F in repairs 15mm dia bib taps, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S&F in repairs 15mm dia bib taps, fancy type, PTMT any colour, high pressure (minimum weight 125gms) screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S&F in repairs 15mm dia pillar taps, fancy type, cast copper alloy, with capstain heads, chromium plated, screwed down, high pressure, with or without lettered 'HOT'/'COLD', with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed
S&F in repairs 15mm dia stop cocks / angle valves, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed
S&F in repairs 15mm PVC connections, 450mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed
S&F in repairs 32mm dia PVC waste pipe, 900mm long, PTMT complete all as specified and as directed
S&F in repairs 20mm dia ball PTMT valves, weighing minimum 210gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
S&F 20mm dia ball PTMT valves, weighing minimum 210gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
S&F in repairs gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, breaking/cutting into cement concrete, masonry, etc. and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs vitreous China squatting pan, Orissa pattern of size 580x440mm, white, with integral foot rests and 'P' or 'S' trap, connecting to flushing pipe and trap and making good to the disturbed surfaces in CM 1:3 with finishes to match with the existing complete all as specified and as directed
S&F in repairs wash hand basin, vitreous China, coloured, flat back type, of size 550x400mm, including CI brackets, cutting for and pinning in ends of brackets with coupling and including PVC connection 60cm key with brass union complete all as specified and as directed
S&F 10litres capacity PVC flushing tank, white / coloured, syphonic action type, low level, valveless, with PVC inlet ball valve, PVC flush pipe, float and suitable sized brackets including cutting of floor / wall and making good to the disturbed surfaces in CM 1:3 with finishes to match with the existing and taking down of old PVC flush tank and disposing off complete all as specified and as directed
S&F internal accessories kit suitable for 10litres capacity PVC flushing tank, including taking out of old damaged set and disposing off complete all as specified and as directed
S&F in repair 110mm bore PVC (SWR) bend of any radius with oval access door complete all as specified and as directed
S&F in repairs 110mm bore PVC (SWR) bend of any radius complete all as specified and as directed
S&F in repairs 75mm bore PVC (SWR) bend of any radius complete all as specified and as directed
S&F in repairs 75mm dia PVC (SWR) 'P' floor trap with chromium plated grating jointed with solvent cement complete all as specified and as directed
S&F PVC (SWR) pipes, 110mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, or laid on floors / in trenches, etc. complete all as specified and as directed
S&F in repairs PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, or laid on floors / in trenches, etc. complete all as specified and as directed
M&L for cleaning kitchen and bathroom trap (floor trap/ gully trap) by using rubber pump and rod including removal of sludge and other foreign materials, etc. complete all as specified and as directed
M&L for cleaning WC / inspection chamber by using rubber pump and rod including removal of sludge and other foreign materials, etc. complete all as specified and as directed
M&L for cleaning / de-sludging of septic tanks, using mechanical pumps, diesel driven, with fuel, operator, etc. and all necessary tools / plants including loading and carting off the drawn sludge, waste material, scum, spoil water, etc. outside MD land through designated sludge carriers / bio tanks complete all as specified and as directed of the following capacities:
25 Users
50 Users
M&L for cleaning / de-sludging of sewage soakage wells/pits of depth 10 to 12m, using mechanical pumps, diesel driven, with fuel, operator, etc. and all necessary tools / plants including loading and carting off the drawn sludge, waste material, scum, spoil water, etc. outside MD land through designated sludge carriers / bio tanks complete all as specified and as directed
M&L for cleaning / de-sludging of manholes of depth 10 to 12m, using mechanical pumps, diesel driven, with fuel, operator, etc. and all necessary tools / plants including loading and carting off the drawn sludge, waste material, scum, spoil water, etc. outside MD land through designated sludge carriers / bio tanks complete all as specified and as directed
M&L for desilting of sewer lines of 110 to 200mm bore, by removing either by mechanical or manual means, the exiting slush/hardened silt/sludge/ any other hardened debris accumulated over a period and in foul conditions (debris like concrete pieces, stone boulders, hardened lime, etc.) including taking out these materials through existing manholes/openings with a lift upto 2m, transportation and depositing at a point within a lead exceeding 50m but not exceeding 100m, spreading, dressing and leveling the heaps to a level not higher than 1m level including all tools, tackles, equipment, labour, etc. complete all as specified and as directed
Notes for item Nos. 89 to 96: (i) All necessary precautions and all safety measures as per Municipality rules / relevant regulatory guidelines shall be taken by the Contractor in employing his mechnical means and workmen. No person shall be employed in direct contact working in septic tanks, manholes, sewage wells, etc. in foul conditions to prevent any health hazards, etc. and only mechanical means shall be used (ii) The Contractor shall be solely responsible for any mishap to any of labourer deployed and to equipment/machinery/plants/material, etc. brought at site for work and any lapses whatsoever during the execution, (iii) The work shall be executed under the supervision of highly skilled tradesman / supervisor (iv) Drawn sludge, waste material, scum, spoil water, etc. shall be removed to outside MD land through designated sludge carriers / bio tanks only (v) To avoid any hazard or spreading of any foul gas bleaching powder shall be spread as directed (vi) The rates quoted shall be deemed to be inclusive of the above aspects, and no claims whatsover shall be entertainable at later stages and or during execution
E/M WORKS
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed
M&L for point wiring with 1.5sqmm (nominal area), two single core, FRLS PVC insulated, conforming to IS: 694, ISI marked, cable of 1100V grade stranded copper conductor, drawn through and including non-metallic PVC casing capping not less than 20mm wide and all accessories flush on walls, ceiling etc. and including provision of 1.5sqmm (nominal area) FRLS PVC insulated stranded copper conductor cable, single core, green colour as earth continuity conductor and connected to common earth dolly, including PVC surface boxes suitable for mounting switch, sockets, etc. and making good the disturbed surfaces to match with existing complete all as specified and as directed for the following:
One light point controlled by one 5A one way switch
One ceiling fan / exhaust fan point controlled by one 5A one way switch
One switch socket outlet 3 pin 5A controlled by one switch on independent board
One switch socket outlet 3 pin 5A controlled by one switch on same board
M&L for point wiring with 2.5sqmm (nominal area), two single core, FRLS PVC insulated, conforming to IS: 694, ISI marked, cable of 1100V grade stranded copper conductor, drawn through and including non-metallic PVC casing capping not less than 20mm wide and all accessories flush on walls, ceiling etc. and including provision of 2.5sqmm (nominal area) FRLS PVC insulated stranded copper conductor cable, single core, green colour as earth continuity conductor and connected to common earth dolly, including PVC surface boxes suitable for mounting switch, sockets, etc. and making good the disturbed surfaces to match with existing for one switch socket combination outlet 3 pin 15A multipurpose complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 5A, 240V complete all as specified and as directed
S&F switch socket combination outlet, 3/5 pin, 5A flush type, universal, ISI marked, 240V complete all as specified and as directed
S&F switch socket combination outlet, 2 in 1, 3 pin, 5 & 15A flush type, universal, ISI marked, 240V complete all as specified and as directed
S&F PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder with back plate 240V complete all as specified and as directed
S&F electronic fan regulator, stepped socket type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F heavy duty, PVC body with PVC blades, legs, ISI marked energy efficient BEE five star rated, 240V exhaust fan, 250mm sweep with lauvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts including taking down old / unserviceable fan any type and disposing off complete all as specified and as directed
S&F MCB TPN, 415V, 63A, 10kA, 50Hz, C curve, complete all as specified and as directed
S&F MCB SP, 240V, 6 to 32A, 10kA, 50Hz, C curve, complete all as specified and as directed
S&F MCB SPN, 240V, 40A, 10kA, 50Hz, C curve, complete all as specified and as directed
S&F sheet metal enclosures for 4 way MCB DB, 240V, TPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down of old enclosure and disposing off complete all as specified and as directed
S&F sheet metal enclosures for 8 way MCB DB, 240V, SPN, single door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down of old enclosure and disposing off complete all as specified and as directed
S&F 1100V grade heavy duty PVC insulated aluminium multistranded conductor cable of size 10sqmm, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1m apart including 4mm suspension wire, one twin core cable flat or circular including taking down old unserviceable wire and disposing off complete all as specified and as directed
S&F in repair LED inverter bulb 9W, retrofit type, AC normal mode & DC in inverter mode with in-built battery backup of upto 4hrs, high efficiency lumens output complete all as specified and as directed
S&F wall mounted 22W LED batten type tube fitting, both side connection box type, with 22W LED tube rod complete all as specified and as directed
S&F wall mounted 22W LED tube light fitting, pin on both side with 22W LED tube rod complete all as specified and as directed
S&F LED street / building security light luminaire 15W, IP-66, with driver, etc. with all accessories rewired and 15W LED lamp including service bracket made out of 40mm bore GI tubing, light grade, cut to suitable length and bent to shape as required complete all as specified and as directed
M&L for taking down tube light fittings 1x22W batten type from any existing location, checking serviceability and repairing for proper functioning and re-fixing in existing / new location including all necessary drilling, etc. complete all as specified and as directed Note: Cost of all minor spares, service wire, screws, etc. shall be deemed to be included in the quoted rate
Taking down old unserviceable submain wiring of any type, any size, from any location or position and disposing off including making good the disturbed surfaces, etc. complete all as specified and as directed
M&L for submain wring using proper colour coding with 4 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 6sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC casing capping 32mm wide, heavy duty, ISI marked surface on wall/ceiling/roof, etc. with all required accessories complete all as specified and as directed Notes: (i) 4 runs of 6sqmm main cable, 1 run of earth conductors and 1 run of PVC casing capping as per item shall be measured as one length (ii) Separate conduit/casing shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit / casing as per requirement at site
M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item No. 126: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
M/S SUBHAM ENTERPRISE
M/s J. C. CONSTRUCTION
M/S DEEDAR ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .