Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
9 Sept 2026, 3:00 pm
CPO-EAST ZONE
THIS TENDER IS BEING FLOATED FOR CONSTRUCTION OF CONTROL ROOM AT KOTA
2600027762-HD-07600
5100027762
Open Tender
Two Bid
Kota, Rajasthan
₹0
₹20,000
18 Aug 2026
18 Aug 2026
9 Sept 2026
9 Sept 2026
18 Aug 2026 - 25 Aug 2026
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | DISMAN&BREAKING OF | DISMAN&BREAKING OF — DISMANTLING AND BREAKING OF EXISTING PLY/MDF PARTITION WALLS, THICKNESS OF ANY SIZES, STORAGE, CEILING, ANY FLOORING AND CARTING AWAY OF DEBRIS FROM SITE SCOPE INCLUDES REMOVING ANY UNNECESSARY CONDUCTS, CABLING, WIRING ETC. AFTER PROPER IDENTIFICATION AND TAGGING AS WASTE AND LIVE. ELEVATION AREA OF WALL SHALL BE MEASURED FOR THE PAYMENT FOR PARTITION/STORAGE WALL AND PLAN AREA OF FLOOR SHALL BE MEASURED FOR THE PAYMENT FOR FLOORING. NO SEPARATE MEASUREMENT WILL BE GIVEN FOR PLASTER ALONG WITH THE BRICK WORK. THE ITEM INCLUDE TRANSPORTATION, LOADING AND UNLOADING OF THE MATERIAL IN A PLACE AND DUMPING AT BMC APPROVED DUMPING GROUND/AS DIRECTED BY ENGINEER IN-CHARGE. THE CONTRACTOR WILL HAVE TO PUT UP A PROPER AND SUFFICIENT HOARDING, SCREEN AND FENCE DURING THE TIME AS MAY BE NECESSARY FOR THE SAFETY AND CONVENIENCE OF THE INMATES OF THE EXISTING BUILDINGS AND MAINTAIN THE SAME IN THE GOOD CONDITION DURING DEMOLITION AND WHERE NECESSARY CAUSE SUCH HOARDING OR FENCE TO BE WELL LIGHTED DURING THE NIGHT TO PREVENT ACCIDENTS. CONTRACTOR WILL HAVE TO MAKE GOOD WITHOUT ANY EXTRA PAYMENT ANY DAMAGE DONE DURING CONSTRUCTION. ANY REMOVABLE EQUIPMENT'S AS ADVISED BY HPCL TO BE SAFELY REMOVED AND HANDED OVER TO HPCL BEFORE STARTING THE DEMOLITION WORKS. | - | LOT |
| 2 | REMOVE&REFIX WOODEN | REMOVE&REFIX WOODEN — TAKING OUT EXISTING WOODEN DOOR SHUTTER, REPAIR BY CUTTING, PAINTING ETC AND RE-FIXING OF REPAIRED DOOR SHUTTERS TO EXISTING DOOR FRAMES, INCLUDING REPLACEMENT OF HINGES WITH SCREWS, ETC. AS REQUIRED, ALL COMPLETE AS PER THE DIRECTION OF THE ENGINEER-IN-CHARGE. | - | square meter |
| 3 | SPLY & FIXG OF TOUGHENED | SPLY & FIXG OF TOUGHENED — PROVIDING AND FIXING 10 MM THICK CLEAR TOUGHENED GLASS OF APPROVED MAKE FIXED TO ALUMINIUM ANODIZED SECTION OF 25 X 25MM INCLUDING REQUIRED MODIFICATION IN MODULAR PARTITION TO HOLD GLASS FIRMLY, FIXING OF ALUMINIUM SECTION TO THE PARTITION FRAMEWORK, EDGE POLISHING, CHAMFERING OF THE EDGES OF GLASS AND SEALING JOINT BETWEEN GLASS WITH TRANSPARENT SILICONE SEALANT OF APPROVED MAKE ALL COMPLETE. | - | square meter |
| 4 | ALUMINIUM GLAZED DOOR | ALUMINIUM GLAZED DOOR — SUPPLYING, FITTING AND FIXING OF ALUMINIUM STILED DOOR WITH THE PROFILE MATCHING WITH DEMOUNATBLE PARTTION AND 10 MM THK. TOUGHENED GLASS WITH GLASKET, HINGES, STOPPER, DOOR CLOSER ETC. ALL COMPLETE. | - | square meter |
| 5 | SPLY AND FIXG OF SWITCH | SPLY AND FIXG OF SWITCH — SUPPLY, FIXING ON MODULAR BOXES, CONNECTION, TERMINATION ETC. COMPLETE 5/6 AMPERE MODULAR SWITCHES. APPROVED MAKE FOR MODULAR ELEMENTS. | - | Each |
| 6 | SPLY AND FIXG OF SWITCH | SPLY AND FIXG OF SWITCH — SUPPLY, FIXING ON MODULAR BOXES, CONNECTION, TERMINATION ETC. COMPLETE 5/6 AMPERE MODULAR SWITCHES. APPROVED MAKE FOR MODULAR ELEMENTS. | - | Each |
| 7 | INSTLN OF LIGHT | INSTLN OF LIGHT — INSTALLATION OF LED TYPE CEILING MOUNTED LIGHT FIXTURE ALONG WITH WIRING, CONDUITS AND OTHER REQUIRED ACCESSORIES. | - | Each |
| 8 | MAKING CABLE TRENCH,1MT | MAKING CABLE TRENCH,1MT — MAKING CABLE TRENCH, DEPTH:1 MT, FOR CABLE LAYING; INCLUDING SUPPLY AND LAYING OF BRICKS AND SAND. | - | Running Meter |
| 9 | SPLY & FIXG OF PLYWOOD | SPLY & FIXG OF PLYWOOD — PROVIDING AND FIXING IN POSITION 9 MM THICK APPROVED MARINE GRADE PLYWOOD OF APPROVED QUALITY AND MAKE FOR PARTITIONS, FACIALS, SKIRTING'S, WALL PANELLING AND SOFFIT ETC AS PER REQUIRED WIDTH AND SIZE OR AS PER DRAWING. RATE TO INCLUDING FIXING THE PLYWOOD TO ALUMINIUM FRAMEWORK WITH SUITABLE SCREWS AT 300 MM SPACING. NECESSARY OPENINGS FOR SWITCHES, AC FACIALS SHALL BE MADE IN THE PLYWOOD AS PER THE REQUIREMENT AT NO EXTRA COST. FIXING TO BE DONE WITH THE HELP OF ADHESIVES LIKE FEVICOL, NAILS/SCREWS ETC. ONE COAT OF FIRE RETARDANT PAINT SHALL BE APPLIED ON THE INSIDE SURFACE OF THE PLYWOOD BEFORE FIXING TO THE PARTITIONS. ALL COMPLETE AS PER DETAIL DRAWING, AS SPECIFIED AND AS DIRECTED BY ARCHITECT/CONSULTANT/ENGINEER-IN-CHARGE. ACTUAL EXECUTED AREA WILL BE MEASURED. | - | square meter |
| 10 | SUP & FIX - FALSE | SUP & FIX - FALSE — PROVIDING AND FIXING MINERAL FIBRE TILE FALSE CEILING CONSISTING OF A. 600 X 600 X 15 MM THICK MINERAL FIBRE ACOUSTICAL TILES WITH DURABLE TEGULAR EDGING HAVING NOISE REDUCTION COEFFICIENT (NRC) VALUE OF MINIMUM 0.50, LIGHT REFLECTANCE VALUE OF MINIMUM 80%, THERMAL CONDUCTIVITY (K) VALUE OF 0.052-0.057 W/M DEG.C AND FIRE PERFORMANCE CONFORMING TO CLASS-I AS PER BS-476, BACK OF THE TILES BEING PROVIDED WITH ONE COAT OF PROTECTIVE COATING. B. SUSPENSION SYSTEM CONSISTING OF HOT DIPPED GALVANISED STEEL MAIN RUNNERS AT MAXIMUM 1200 MM C/C, CROSS RUNNERS, PERIMETER SECTIONS INCLUDING SUSPENDING THE SYSTEM BY MEANS OF MS WIRE, MS CLEAT, DASH FASTENERS AND LEVEL ADJUSTORS, PROVIDING 30 MICRON POWDER COATING TO EXPOSED METALLIC MEMBERS, PROVIDING SLIT OPENINGS FOR FIXING SUPPLY/RETURN AIR GRILL, LIGHTING FIXTURES, AC DUCTS ETC. WITH BYE WORKS ALL COMPLETE. WITH FINE FISSURED TILES ACOUSTICAL PUNCHERS, AS PER THE SCOPE OF JOB OF THE TENDER. | - | square meter |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2600027762-HD-07600.pdf
TENDER_DOCUMENT • 10.89 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].