Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹23.2 L+₹1.3 L (6.14%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹24.1 L+₹2.2 L (10.1%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹27.2 L+₹5.3 L (24.3%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
17 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
REPAIR/MAINT OF INTERNAL ELECTRICAL APPLIANCES IN TECH AREA OTMs AND MARRIED ACCN OF AF STN AMBALA UNDER GE (AF) AMBALA
2024_MES_637523_1
GE AF/ AMB-T-75/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹98,000
Yes
14 Mar 2024
15 Jan 2024
19 Feb 2024
15 Jan 2024
17 Feb 2024
3 Feb 2024
Amount
Taking out of ceiling/exhaust fan/Air circulator fan from AGE E/M store yard/Site and transport to reputed workshop for rewinding the fan starter with the same gauge of copper winding wire as well as number of turns and reassembling the fan after replacing the unserviceable spares like bushes, shafts, fasteners, bearings, capacitors and flexible cord for putting fan in serviceable condition including refixing the same after carrying out necessary repairs to original place of following sizes complete all as specified and directed by Engineer-in-Charge. Note:- Bushes, shafts, bearings, capacitors, flexible wires,painting etc. shall be measured and paid separately
Ceiling Fan (1200/ 1400 mm) size of any make
Exhaust Fan of 230/300mm size of any make.
Exhaust Fan of 400/450 mm size of any make
Wall Fan Of Any Size/Any make
M&L for Replacement of capacitor 2.50/3.15/4.0 mfd capacity (condenser) of exhaust and ceiling fans complete all as specified and as directed.
S&F 3 core PVC flexible copper conductor cable(cord) of 0.5 Sqmm complete all as specified and as directed.
S&F GM bushes for ceiling/exhaust fans of various sizes complete all as specified and as directed.
Taking old unserviceable PVC body air freshner and supply and fixing PVC body air freshner 220/230 mm sweep single phase 230 volts including lovers and fixing arrangement as per site requirement complete all as specified and as directed.
S&F of M.S. clamps for hanging ceiling fan with nuts, checknuts and bolts 2" x 3/8" : 02 Nos. including rubber rings(reel) for hanging ceiling fans complete all as specified and as directed.
Taking down ceiling fan/exhaust fan for overhauling,oiling greasing etc and reassembling the same after necessary replacement of unserviceable parts like bush, capacitors, wire, bearing, etc. refixing the same with proper fitting of blades, clamps, split pin, etc, complete all as specified and directed. Note : Bushes, shafts, bearings, capacitors, flexible wires,painting etc. shall be measured and paid separately
M&L for painting with two coats of white synthetic enamel paint after preparation of surface and marking MES No by black permanent marker complete all as specified and directed.
Supply & Fix ball bearing suitable for following ceiling/exhaust fans complete all as specified and directed.
Ceiling Fan of any make/size of any make
Exhaust Fan of any make/size.
S&F down rod of 20mm GI tubing medium grade for extension rod n.exc 60 cm each for ceiling fans including cutting, threading and drilling holes etc complete all as specified and directed.
Taking out/dismantling of old unserviceable check valve of of pressure pump of capacity (0.5 to 1 HP) and supply and fixing of new check valve made of brass size 15/25/32 mm dia complete all as specified and directed.
Taking down old unserviceable Auto cut and supply and fixing new auto cut (pressure release valve ) suitable for pressure pump of capacity 0.5 -1.0 HP complete all as specified and directed.
Taking out/dismantling of pressure pump of capacity 0.5 -1.0 HP at site to reputed workshop for rewinding the pressure pump with the same gauge of copper winding wire as well as number of turns and reassembling the pump after replacing the unserviceable spares part like bushes, shafts, fasteners, bearings, capacitors and copper wire for putting pump in serviceable condition including refixing the same after carrying out necessary repairs to original place complete all as specified and directed. Note :- Spare parts , rewinding work etc required for repairing the pump shall be deemed to be included in the quoted rate by contractor.
Taking down carefully aluminum point wiring (light, fan, socket or power) complete fittings such as switches, C/roses, Pendants DBs, sockets etc. including taking down carefully by unscrewing from boards/outlet/DBs/fittings such as switches, sockets, lamp holders, brackets, ceiling fittings bulkhead fittings, tube light fittings, fan regulator, electric meters, meter box any type etc and making good to the disturbed surface by plastering and two coat of distemper &, matching with existing, surface complete all as specified and directed by Engineer-in-Charge.
M & L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 20mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly complete all as specified and directed for the following :-
One light/fan/ controlled by one switch 6 amp one way
One 3 pin switch socket combination 6 amp on the independent board, complete all as specified and directed.
One 3 pin switch socket combination on same board with other switches, complete all as specified and directed.
One bell point controlled by one bell push complete all as specified and directed.
All as per BOQ srl item No. 15.00 here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board, complete all as specified and directed.
M & L for point wiring in existing concealed conduit complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through existing conduit including provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete all as specified and directed for the following:
One light/fan/ controlled by one switch 6 amp one way.
One 3 pin switch socket combination 6 amp on the independent board.
One 3 pin switch socket combination on same board with other switches.
All as per BOQ srl item No. 16.00 here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board, complete all as specified and directed.
M & L for point wiring on wall/ surface in steel conduit of size 20 mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and including steel conduit with all accessories including provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete all as specified and directed for the following.
One light/fan/ controlled by one switch 6 amp one way
One 3 pin switch socket combination 6 amp on the independent board.
All as per BOQ srl item No. 17.00 here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and directed.
Supply and fix switch piano modular type 5 amp single pole flush type one way complete all as specified and directed.
Supply and fix switch piano modular type 15 amp single pole flush type one way complete all as specified and directed.
Supply and fix socket outlet modular type 3 pin 5 amp multi pin flush type complete all as specified and directed.
Supply and fix socket outlet modular type 6 pin 15 amp multi pin flush type complete all as specified and directed.
Supply and fix modular step type fan regulator electronic type 120 watt 2 module all as specified and directed.
Supply and fix modular cover plate with frame for 2 module complete all as specified and directed.
Supply and fix modular cover plate with frame for 3 module complete all as specified and directed.
Supply and fix modular cover plate with frame for 4 module complete all as specified and directed.
Supply and fix modular cover plate with frame for 6 module complete all as specified and directed.
Supply and fix modular cover plate with frame for 8 module complete all as specified and directed.
Supply and fix modular metal flush box 2 module complete all as specified and directed.
Supply and fix modular metal flush box 3 module complete all as specified and directed.
Supply and fix modular metal flush box 4 module complete all as specified and directed.
Supply and fix modular metal flush box 6 module complete all as specified and directed.
Supply and fix modular metal flush box 8 module complete all as specified and directed.
Supply and fix switch piano flush type single pole, one way 06 amp complete all as specified and directed.
Supply and fix switch piano flush type single pole, one way 15 amp complete all as specified and directed.
Supply and fix socket outlet 2 in 1 , 3 pin 5 A flush type complete all as specified and directed.
Supply and fix socket outlet 2 in 1 , 3 pin 5 A and 15 A flush type complete all as specified and directed.
Supply and fix ceiling rose 65x50mm three terminals 230 volt all as specified complete all as specified and directed.
Supply and fix lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting complete all as specified and directed.
Supply and fix bell push flush type 230 Volt complete all as specified and directed.
Supply and fix call bell ding dong 230 V single phase complete all as specified and directed.
Supply and fix fan regulator electronic type in 5 steps of capacity 120 Watt complete all as specified and directed.
Supply and fixing in replacement recess mounting LED down light of 12 watt of existing make/model complete all as specified and directed.
Supply and fixing in replacement recess mounting low height backlit round LED down light of 18 watt of existing make/model complete all as specified and directed.
Supply and fixing in replacement recess mounting low height backlit square LED down light of 6 watt of existing make/model complete all as specified and directed.
Supply and fixing in replacement recess mounting low height backlit square LED down light of 3 watt of existing make/model complete all as specified and directed.
S&F 1X18/20 incl taking down watt wall mounted, new generation LED T-8 Retro fit for multipurpose application with LED Rod , made from extruded aluminium housing,polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement recess/Surface mounting LED flat panel 2'x2' with high efficient LED & glare free full window opal diffuser of 36 watt incl connection with twin core twisted flexible copper conductor cable with suitable size rod complete with all accessories complete all as specified and directed. Note : The LED fitting should Have PF >0.9 ,input voltage 90-300V, IP-65 , LM 80 stranded luminaries efficiency 100 lumen/watt
S&F in replacement energy efficient LED Flood light fitting of 70 watt and input voltage 230 VAC, 50 Hz with ingress protection -IP 66 with CRCA housing including fixing arrengment like clamp nut bolts and washers CRI > 70, PF>0.95, Min 50000 burning Hrs, THD> 20 complete all as specified and as directed.
Supply and fixing incl taking down of flame proof weather proof LED light fitting 20W with all accessories including lamp and necessary connection wire and testing complete all as specified and directed.
Taking down/out old unserviceable building security light of any type / wattage and Supply and fixing LED light fittings 35 watts, input 120 volts to 280 volts volts, life > 25000 Hrs, operating temp -20 degree to 50 degree,color temperature 5700K, initial efiicacy>= 100 lm/watt ,IP 66 , high pressure Die cast aluminium housing with weather proof gasket for lamp . the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 5 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60598/IS10322 necessary connection with multistranded copper conductor cable 3 core 1.0 sqmm from ceiling rose to fitting drawn through GI bracket complete all as specified and directed .
S&F in replacement energy efficient LED Street light fitting (Beamer) of 90 watt and input voltage 230 VAC, 50 Hz with ingress protection -IP 66 with CRCA housing including fixing arrengment like clamp nut bolts and washers CRI > 70, PF>0.95, Min 50000 burning Hrs, THD> 20 complete all as specified and as directed.
M&L for submain wiring in replacement with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly including dismantling old and making good to the disturbed surface by plastering and two coat of distemper complete all as specified and directed. Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
Complete all as per BOQ item No 53.00 above but for 2x6 sqmm copper conductor FRLS cable and 1x6 sqmm copper conductor FRLS cable for earth continuity as a earth wire drawn in PVC conduit 20 mm dia conduit heavy duty complete all as specified and directed by Eng-in-Charge. Note: Two runs of 6 sqmm cable alongwith one run of 6 sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
Supply and fixing in replacement sheet metal enclosures 4 way TPN Vertical type loadline distribution board of 4 way incomer + 12 module outgoings , double door IP 43 protection 160 A rated bus bar blanking plates duly flush in wall and making good disturbed surfaces complete all as specified and directed .
Supply and fixing in replacement MCCB three pole 415 Volts, 100 A, rupturing capacity 16 KA complete all as specified and directed.
S&F sheet metal enclosures for MCB distribution board 230 Volts TPN 4 way double door type with 200 Amp rated bus bar concealed in wall including making the surface good complete all as specified and directed.
S&F sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way double door type with 200 Amp rated bus bar concealed in wall including making the surface good complete all as specified and directed.
S&F sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 12 way double door type with 200 Amp rated bus bar concealed in wall including making the surface good complete all as specified and directed.
S&F sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 2 way double door type flushed inside the wall with 200 Amp rated bus bar concealed in wall including making the surface good complete all as specified and directed.
S&F MCB three pole and neutral 415 Volts, 63 A, 10 KA complete all as specified and directed.
S&F MCB single pole and neutral 240 Volts, 40-63A, 10 KA, B Curve complete all as specified and directed.
S&F MCB single pole 240 Volts, 6 to 32 A, 10 KA, B Curve complete all as specified and directed.
M&L for in replacement of earthing complete with galvanized steel earth plate electrode 60x60x0.6cm buried directly in ground to a depth not less than 2.25 Mtr below ground level and top edge of plate not less than 1.5 Mtr below ground level, connected to galvanized earth wire 4 mm by means of GI bolts, nuts, check nut, washer all as shown on Electric Plate No 3 of SSR including earth pit in any soil, char coal, common salt, Black cotton soil in earth pit, 15cm all around earth plate, PCC (1:2:4) type B1 Pit with 40x40x6mm angle iron frame and PCC cover (1:2:4) Type B1, water pipe, funnel GI wire mesh and GI protection pipe light grade 15mm dia 7.5 Mtr in length, connecting earth lead to DB/ LT Panel, etc complete all as specified & directed. Notes: (i) Cost of Earth strip/wire and GI pipe for protection of earth wire/strip upto 7.50 metre shall be deemed to be included in the quoted rate. (ii) On testing if the desired earth resistance is not obtained, entire earthing shall be re-done by contractor/ till desired earth resistance is not obtained without accruing any extra cost to department. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
S&F in replacement plug top & socket with sheet metal enclosures Single pole including one MCB 20 Amp, 240 Volts,10 KA complete all as specified & directed.
S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor derved with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire one twin core flat of size 6 sqmm sold aluminium conductor complete all as specified and directed.
S&F ceiling fan complete with blades, down rods, fan regulator socket type and accesssories, 230V , 1200mm sweep , Min air delivery 210CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) without reomte complete all as specified and directed.
S&F steel body exhaust fan 250/300 mm sweep single phase 230 volts including flap and fixing arrangement as per site requirement complete all as specified and directed.
S&F steel body body exhaust fan 450 mm sweep single phase 230 volts including lovers and fixing arrangement as per site requirement complete all as specified and directed.
M/S Sonu Traders
Mohinder Pal and Sons
OMVIN ENTERPRISES LLP
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .