3 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JAIPUR
HQ CWE JAIPUR KALYAN MARG JAIPUR
SPL REPAIR TO BLDG NO T-1, T-2, T-3 AND T-4 IN 18 INF DIV PRO UNIT AT MIL STN KOTA
2021_MES_434605_1
CWE/82070/KOTA/E8
Open Tender
Civil Works
Item Rate
180 days
KOTA
Enlisted with MES in Class E and above and category a(i)
7 documents required · 7 mandatory
₹500
Yes
GE KOTA
₹40,000
Yes
28 Jun 2021
6 Apr 2021
5 May 2021
6 Apr 2021
3 May 2021
20 Apr 2021
60 days
Amount
Taking down cement plaster or cement lime plaster on PCC/stone surface/ brick surfaces/ceiling etc. including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Demolition Cement concrete (unreinforced) concrete of any description and in any position not otherwise specifically provided etc complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material outside of MD land etc complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) not exceeding 1.5 sqm each and removing to store etc complete all as specified and as directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm etc complete all as specified and as directed.
M&L 75 mm thick cement concrete type B-1 (1:2:4) using 20mm graded stone aggregates as in floors, surfaces finished even and fair without using extra cement etc complete all as per specified and directed.
M&L brickwork with fly ash bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6 using modular bricks etc complete all as per specified and directed.
M&L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3m in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in (1:3) etc complete all as specified and directed .
S&F rolled mild steel framed work as in doors or gates of angle or other section with gusset plates rails, braces etc. complete, drilled for fixing or steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooke and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe -290 ( Gde-E-165 ) etc complete all as specified and directed.
S&F (powder coating of any colour thickness or power coating not less than 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, duly power coated and aluminium sections weighing not less then 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150mm long (1No) hinge type B-21 100mm long (2Nos) suitable handle (1 No) etc. complete all as specified and directed.
S&F powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing (minimum thickness of powder coating 50 micron) etc complete all as specified and directed.
S&F aluminium anodised grill made out of 10mm dia rod fixed with and including standard aluminium frame of ‘F’ section of size 23.4mmx15.3mmx1.4mm thick all as per manufacturer’s instruction etc. complete all as specified and directed.
S&F of 5.5mm thickness sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5sq.m in each pane etc complete all as specified and directed.
S&F stainless steel wire cloth 0.56mm dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples etc complete all as specified and as directed.
S&F in repair galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples in door and steel window etc complete all as specified and directed
M&L preparation old untreated steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint over etc complete all as specified and directed
M&L for complete removal of existing treatment on walls, chajjas etc including cleaning of any mortar drops, fungus efflorescent salts etc and preparation of old plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over one coat of wall care putty etc complete all as specified and directed.
M&L for preparation of old plastered or unplasterd surfaces & applying one coat of white wash on ceilings etc complete all as specified and directed.
S&F in repairs stainless steel tubular curtain rods, 20mm dia, fixed with and including decorative type end brackets etc complete all as specified and directed.
M&L machine pressed precast concrete rubber moulded interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, with grey cement and pigment laid over and including 25mm thick sand cushion layer including providing 100 mm thick PCC type B-2, (1:2:4) using 40mm graded stone aggregate etc complete all as specified and directed.
M&L Pre-cast (factory casted) cement concrete kerb stone casted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with plain or interlocking joints, making groove in ground of desired dimension, placing in erect position kerb stone in edging and set and jointed in cement mortar 1:4 etc complete all as specified and directed.
M&L for 20-25 mm thick machine cut kota stone slab flooring laid over 20 mm thick screed bed or bedding layer of cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grooving, rubbing and polishing etc complete all as specified & as directed.
M&L for 20-25 mm thick machine cut kota stone slab in riser of steps, skirting, dedo and pillar laid over cement screed 15 mm thick in cement mortar (1:4), laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified & as directed.
Dismantling of Plain or corrugated steel/FRP sheeting any gauge, thickness, including or similar pattern roof/wall covering etc complete all as specified and directed.
S&F pre painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and washers etc complete all as specified and directed.
S&F in repair pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe 15mm etc complete all as specified & directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out in trenches, if required Internal dia of pipe 100 mm etc complete all as specified & directed by Engineer-in-Charge.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out in trenches, if required Internal dia of pipe 75 mm etc complete all as specified & directed by Engineer-in-Charge.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store bore of pipe in 15mm etc complete all as specified & directed by Engineer-in-Charge.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store bore of pipe in 20mm etc complete all as specified & directed by Engineer-in-Charge.
M&L galvanised steel water tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors of bore of tube 15mm etc complete all as specified & as directed.
M&L galvanised steel water tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors of bore of tube 20mm etc complete all as specified & as directed.
Fixing only galvanised steel water tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors of bore of tube 15mm etc complete all as specified & as directed.
Fixing only galvanised steel water tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors of bore of tube 20mm etc complete all as specified & as directed.
S&F capacity of 1000 Litres rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of old water tanks etc complete all as specified & directed.
S&F of solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, fixing in opening etc complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement etc complete all as specified and directed by Engineer-in-charge.
S&F Aluminium anodised barrel tower bolt 150mm long of extruded section and fixed etc complete all as specified and directed.
S&F 150 mm long extruded aluminium alloy handles, fabricated type, anodised etc complete all as specified and directed.
S&F of 100 mm butt hinges medium weight cold rolled mild steel, ISI marked, fixed to angle iron chowkhat including welding etc complete all as specified and directed.
M&L for rendering 15mm thick on stone masonry surfaces or surface other than fair faces of brick work on wall CM (1:4) on walls finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for rendering 15mm thick on stone masonry surfaces or surface other than fair faces of brick work on wall CM (1:6) on walls finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:4) on concrete surfaces including finished even & smooth on ceiling etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick masonry or on other than fair surfaces of brick masonry, finished even & smooth without using extra cement etc complete all as specified and directed.
S&F coloured glazed ceramic tiles first quality of size (450X350)mm, 7 to 8 mm thick , in vertical surfaces etc set and jointed in neat cement slurry and pointed in coloured cement to match shade of tiles and including providing 15mm thick backing coat in CM (1:4) etc complete all as specified and directed.
M&L non skid ceramic tiles (coloured) 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including providing 25 mm PCC (1:2:4) type B-1 using 20mm graded stone including providing 15mm thick screed bed in CM (1:6) etc complete all as specified and directed.
S&F ball brass valves, high pressure, with polythene float and fly-nut complete, screwed for iron pipe or brass ferrule and fixed of pipe in 20mm etc complete all as specified & directed.
S&F in repair Vitreous China bowl urinal flat back, size of (465 x 355 x 265)mm white (minimum), with grating and union for discharge pipe Vitreous china urinals, bowl type (back or corner wall type), complete including 32mm waste Fittings ,Brass, Chromium Plated For Glazed Ware Sinks, Basins, Etc. With Long Screwed And FlyNuts, Flange End Bedded In Red Lead Cement And Other end fixed including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe.
S&F in repair brass chromium plated tubular towel rail, 20mm dia, 'D' type, 60cm long between flanges etc complete all as specified and directed.
S&F in repair Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) etc complete all as specified and directed.
S&F in repairs 15mm bore PVC connections, with PTMT nuts of length 450mm etc complete all as specified and directed.
S&F in repairs stop valves cast copper alloy screwed down high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions in 15 mm bore dia pipe etc complete all as specified & directed.
S&F in repairs stop valves cast copper alloy screwed down high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions in 20 mm bore dia pipe etc complete all as specified & directed.
S&F in repairs 15mm dia bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated with long shank and cyp (concealed type) etc complete all as specified & directed.
S&F in repairs to 15mm dia bib taps, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule etc complete all as specified & directed.
S&F in repair Vitreous china squatting pan Orrisa pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including providing PCC (1:2:4) type B-1 for making good the floor etc complete all as specified & directed.
S&F in repair PVC valve less syphonic action type flushing cistern 10 litres capacity, low level white with inlet ball valve float and handle including brackets including 32mm dia PVC flushing pipe of polyethylene of low or high density etc complete all as specified & directed.
S&F in repairs Vitreous China wash basin white flat black size of (580 X 450)mm including 15mm dia,450mm long HDPE PVC connection, 32mm bore 750mm long HDPE waste down pipe with CI brackets etc complete all as specified & directed.
M&L PVC (SWR) floor trap, plain with grating including jointing with solvent cement fixed to 75mm bore of pipe including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 etc complete all as specified & directed.
M&L 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls etc complete.
M&L 110mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls etc complete.
S&F 110mm bore PVC (SWR) junction single, (single T), equal or unequal etc complete all as specified and directed.
S&F 75mm bore PVC (SWR) junction single, (single T), equal or unequal etc complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends (any radius) etc. complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends (any radius) etc. complete all as specified and directed.
M&L in repair 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed and flynuts, flange end bedded in red lead cement and other end fixed etc complete all as specified and directed.
M & L in repair 32mm bore dia Waste coupling of PTMT (half or full threaded) suitable for urinals, (Minimum weight 32mm-45gms ) of discharge pipe etc complete all as specified and directed.
S&F in repair grating round 140 mm size of PTMT.(Minimum weight 50gms) etc complete all as specified and directed.
M&L preparation of new steel surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer etc complete all as specified and as directed.
M&L preparing newly plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over a coat of 1mm thick wall care putty to make smooth the undulated surfaces etc complete all as specified and directed
M&L for preparing new plastered surfaces and applying three coats of white wash on ceiling etc. complete all as per specified and directed.
M&L for preparation of newly plastered surfaces & applying three coats of white wash on wall etc complete all as specified and directed.
M&L for preparing newly plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer on wall etc complete all as per specified and directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of cement base paint over a coat of 1mm thick wall care putty on walls/chajja etc complete all as specified & directed by Engineer-in-Charge.
M&L 25mm thick (measured solid), providing precast cement concrete (1:2:4) type B0 using 12.5 mm graded stone aggregate in louvers and jallies, including all mouldings but excluding frame set in cement mortar (1:4) etc complete all as specified and directed.
Water proofing treatment shall be carried out as under :-
(a) M&L 25mm thick PCC Type B0, (1:2:4), using 12.5 mm graded aggregate in laid over roof slab applying cement slurry for filling undulations finished even and smooth without using extra cement etc complete all as specified and directed.
(b) M&L for applying cement slurry over existing roof surface @ 3.0 kg/Sqm etc complete all as specified and directed.
(c) M&L screed bed or bedding layer or motor, 15mm thick in cement mortar 1:4 over RCC roof slabs for laying water proofing treatment mixed with using water proofing liquid @150 ml per 50 Kg bag of cement etc complete all as specified and directed by Engineer-in-Charge.
(d) Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm , black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over compatible bitumen primer at the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions complete all as specified and as directed. Above complete application will be done authorized applicator from Manufacturer and manufacturer's specification. Make: Super thermolay manufactured by STP Ltd/ ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd/ ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd/Torchtar Membranes and bitumen product Pvt Ltd/Tiki Tar Danosa
Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) All above aspects are deemed to be included in quoted rate.
Supply integral water proofing liquid of make Dr Fixit or equivalent in Sika/Fosroc
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar Internal dia of pipe 150 mm etc complete all as specified and directed.
M&L for salt glazed stoneware drain pipes grade 'A' laid in trenches and jointed in cement mortar 1:1 tested complete 150 mm dia complete all as specified and directed.
M&L concrete bed in PCC 1:3:6 type C-2 to drain pipes of 150 mm bore including packing under and hunching against the sides of pipes after they are laid and tested etc complete all as specified and directed.
M&L cement concrete, Type B0, (1:2:4) using 12.5 mm graded aggregate in lintels upto 1.5 mm clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses parapets and railings upto 60 cm in height, copings kneelers, apex stones bed plates, water trough and like including weathering ,slightly rounded or chamfered angles and throating, etc complete all as specified and directed.
Taking down carefully surface aluminium or copper point wiring with PVC casing capping or conduit (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces etc complete all as specified & directed.
Taking down carefully unserviceable rusted main switch/DB with MCBs of any size capacity and make etc. complete all as specified and directed.
Taking down carefully sub main wiring with PVC casing capping / PVC surface conduit and service wiring with making good surface etc complete all as specified & directed.
Taking down carefully old unserviceable ceiling fan/exhaust fan and refixing the same after repair of any size and make etc. complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sq mm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 Sq mm (Green) drawn into and including rigid non-metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories on surface for walls, roofs, floors etc including unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators as required for the following :- (Note :- Cost of cutting of chases in stone masonry and making good disturbed surfaces for concealing the conduit shall deemed to be included in quoted rate of point wiring).
(a) One light/fan/bell point controlled by one switch.
(b) One 3/5 pin socket outlet 6 amp controlled by one switch on the same board with other switches.
(c) One 3/5 pin socket outlet 6 amp controlled by one switch on independent board.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 Sq mm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 Sq mm (Green) drawn into and including rigid non-metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories on surface of walls roofs, floors etc including sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets as required for one 16 amp socket outlet point controlled by one switch on independent board. (Note - Cost of cutting of chases in stone masonry and making good disturbed surfaces for concealing the conduit shall be deemed included in quoted rate of point wiring). Complete all as specified & directed.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:-
2x6 sqmm + 1x4 sqmm earth wire in 25 mm dia conduit.
4x10 sqmm + 2x6 sqmm earth wire in 50 mm dia conduit.
S&F switch piano flush button single pole one way 6 Amp 230 volts etc. complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 6 Amps flush type universal 230 volts etc. complete all as specified and directed.
S&F switch socket combination 5 in 1, 3/5 pin, 16 Amps flush type universal 230 volts etc. complete all as specified and directed.
S&F socket outlet 3 pin, 6 Amps flush type 230 volts etc. complete all as specified and directed.
S&F angle holder, insulated polycarbonate body with back plate etc complete all as specified & directed.
S&F ceiling rose surface bakelite 65mm x 50 mm three terminal ISI marked including suitable size of PVC board etc. complete all as specified and directed.
S&F stepped type electronic step fan regulator, flush type 200 watts, on the existing phenolic laminated sheet etc complete all as specified & directed.
S&F in wall mounted LED batten fitting, extruded aluminium heat sink for efficient heat dissipation with internal electronic driven,20 watts 3000K of make Havells 20W Endura Linear Neo - Cat No LHEWEBP6IN1W020 or equivalent as mentioned in Appx’B’
S & F MCB distribution board powder coated , CRCA steel sheet, degree of protection IP 43-IK 09 with reversible double door, recess mounted having insulated 100 Amps tinned copper bus bar, neutral busbar, earth bar detachable gland plate interconnection earthing connection , blanking plates in unused spaces including connections of wires in MCBs/RCCBs/RCBOs/MCCBs with suitable size lugs of copper materials. DBs shall be fixed on wall in flush pattern by chase cutting in stone or brick wall and disturbed surfaces shall be made good even and smooth using CM (1:3) as required with following ratings & ways:-
(a) Single door SPN, 240 volts, 8 ways
(b) Single door TPN, 415 volts, 4 ways
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
(a) MCB TPN 63 Amps 415 Volts
(b) MCB SPN 6-40 Amps 240 Volts
(c) MCB SP 6-32 Amps 240Volts
Earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. Charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion
S&F steel tubes 40 mm bore light grade ISI marked with medium grade fittings for cable protection as required etc complete all as specified & directed.
S&F security light fitting LED type 45 watts including bracket made of GI Pipe 32mm dia, 1.5 meter bent to sharp and fixed on walls with suitable clamps etc complete all as specified & directed.
Supply and laying or fixing on wall or passing through pipe testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape/ wire armoured underground stranded aluminium conductor cable of size 25 sq mm 3.5 core complete all as specified & directed.
Supply and laying or fixing on wall or passing through pipe testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape/ wire armoured underground stranded aluminium conductor cable of size 10 sq mm 2 core complete all as specified & directed.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc or for shaft, well, cesspit, manhole, pier holes etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out soft/loose soil.
Returning filling with earth obtained from excavation including spreading watering and consolidation in layers not exceeding 25 cm thick .etc complete all as specified & directed.
Removal of excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point etc complete all as specified & directed.
M&L for sand filling in trenches with clean dry fine sand unwashed including gently punning around cables etc complete all as specified & directed.Note :- Punned thickness shall be measured.
Supply and laying old size bricks, common burnt clay building bricks sub class ‘B’ designation 75 laid in trenches over sand for cable protection etc complete all as specified & directed.
Schedule of Credit
Ganesh Contruction
M/s Prem Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .