Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83.6 LAccepted-AOC A 102 GOLDEN SAND APARTMENTS GAZIPUR DHAKOLI ZIRAKPUR PB 160104 | ZIRAKPUR | S A S NAGAR | PUNJAB | 160104 | ₹83.6 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹84.1 L+₹55,384 (0.66%)Rejected-Finance | ₹84.1 L+₹55,384 (0.66%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹84.5 L+₹92,899 (1.11%)Rejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹84.5 L+₹92,899 (1.11%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹89.7 L+₹6.2 L (7.39%)Rejected-Finance | ₹89.7 L+₹6.2 L (7.39%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹93.9 L+₹10.4 L (12.4%)Rejected-Finance FLAT NO 201 GF KAMAL VIHAR CGHS LTD PLOT NO 5 SECTOR 7 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹93.9 L+₹10.4 L (12.4%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹87.7 L
EMD Value
₹1.6 L
Closing Date
18 Jan 2021, 6:00 pmClosed
CE (AF) WAC PALAM, DELHI CANTT-10
HQ CE (AF) WAC Palam Delhi Cantt-10
Provn of Centrally Air Conditioning for Auditorium at AF Stn Chandigarh
2020_MES_401652_1
CEWAC/CHD/T-09/2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) CHANDIGARH
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (AF) Chandigarh
₹1.6 L
Yes
15 Mar 2021
8 Dec 2020
20 Jan 2021
8 Dec 2020
18 Jan 2021
5 Jan 2021
9 Dec 2020 - 29 Dec 2020
Amount
Water Cooled Chilling Machines Supply, installation, testing and commissioning of 60TR water cooled Scroll Chilling Machines fitted with hermetically sealed compressors, multi circuit DX chiller water cooled Shell and Tube condenser. Microprocessor based control panel, suitable for R-407 C Refrigerant. Shell & Tube Insulated Evaporator, Expansion Device, Suitable capacity Control Mechanism actual cooling capacity on following Operation Parameters as under. Complete as per specifications: - Chilled Water Entering Temperature: 12.17 deg C Chilled Water Leaving Temperature: 6.67 deg C Evaporator Fouling Factor: 0.0001 MKS Condenser Water Entering/Leaving Temperature at 36.2/32.4 deg C Refrigerant: R-407 C Maximum Allowable IKW / TR @ 100% Load: 1.55 Scope of Supply a) 1 Set: - Scroll compressor hermetic complete with suaitble capacity squireII cage induction motor with class 'F' insulation suitable for operation on 415 Plus/Minus 10% volts, 50Hz, A.C. supply and automatic capacity control, safety switches. forced feed lubrication system etc. as per specifications. b) 1 No: - Close transition type automatic star-delta starter suitable for compressor motor complete with ammeter with CTs. Over load protection. under voltage protection, protection against phase reversal & independent single phase preventors etc. complete as required. c) 1 Set: - Lubrication device consisting of automatic electric oil pump, oil cooler. Oil strainer. automatic pressure regulating valve. oil heater, oil heater thermal switch etc. as per specifications.
d) 1 Set: - Matching Water Cooled condenser having Copper tube with mechanically bonded aluminium fins. e) 1 No: - Matching DX type chiller for Chiller units. f) 1 Lot- Refrigerant piping fittings, valves and accessories to interconnect compressor, condenser, chiller and expansion valve. g) 1 Set- Microprocessor based control panel complete with all safeties, controls and LCD display as per specifications. h) Lot: - Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications. i) Lot: - Water flow switches at inlet and outlet of chiller Water drain and air purge valves whenever required. j) Lot: - Suction line and chiller insulation with minimum 19mm thick polyvinyl nitril rubber insulation complete as required. k) Lot: - Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti-vibration pads/springs. l) Lot: - Initial / first charge of refrigerant gas and compressor oil. m) 1 No: - Chilled water flow Switch of suitable size and capacity. n) Lot: - PCC cement concrete foundation for the Chiller unit (2 Working simultaneously & 1 Working standby) Note : In case 60 TR compressor is not avaible contractor will provide next higher capacity of compressor within overall cost quoted and nothing extra shall be payable.
CHILLED WATER PUMP SET Supply, Installation, testing and commissioning of centrifugal mono block chilled water pump set capable of delivering minimum 300 USGPM of water against 30.00 mtr head each comprising of the following and complete as per specifications. a) 1 No: - mono block type pump b) 1 No: - Suitable HP TEFC squirrell cage induction motor with class 'F' insulation 2900 rpm synchronous speed, operating on 415 + 10% volts, 3 phase, 50 Hz A.C. supply. c) Lot- insulation of pump of 13 mm thick with aluminium foil faced closed cell chemically crossed XPE foam material. d) 2 Nos. -100 mm dia dial type pressure gauges. e) Lot: - Mounting frame with Anti vibration pads. f) Lot: -PCC cement concrete foundation for the pump unit. (1 working simultaneously & 1 working standby:- each of 100% capacity).
CONDENSER WATER PUMP SET Supply, Installation, testing and commissioning of centrifugal mono block Condenser water pump set capable of delivering min. 400 USGPM of water against 22.00 mtr head each comprising of the following and complete as per specifications. a) 1 No: - mono block type pump b) 1 No: - Suitable HP TEFC squirrell cage induction motor with class 'F' insulation 2900 rpm synchronous speed, operating on 415 + 10% volts, 3 phase, 50 Hz A.C. supply. c) 2 Nos. -100 mm dia dial type pressure gauges. d) Lot: - Mounting frame with Anti vibration pads. e) Lot: -PCC cement concrete foundation for the pump unit (1 working simultaneously & 1 working standby:- each of 100% capacity)
HOT WATER PUMP SET Supply, Installation, testing and commissioning of centrifugal mono block hot water pump set capable of delivering minimum 120 USGPM of water against 30.00 mtr head each comprising of the following and complete as per specifications. g) 1 No: - mono block type pump h) 1 No: - Suitable HP TEFC squirrell cage induction motor with class 'F' insulation 2900 rpm synchronous speed, operating on 415 + 10% volts, 3 phase, 50 Hz A.C. supply. i) Lot- insulation of pump of 13 mm thick with aluminium foil faced closed cell chemically crossed XPE foam material. j) 2 Nos. -100 mm dia dial type pressure gauges. k) Lot: - Mounting frame with Anti vibration pads. l) Lot: -PCC cement concrete foundation for the pump unit. (1 working simultaneously & 1 working standby:- each of 100% capacity) Note for Items 2, 3 & 4 :a) Head calculations for pump set shall be submitted by contractor for approval by GE. No adjustment shall be allowed for variation of plus/minus 5 mtr. b) Discharge calculations shall be submitted by contractor for approval by GE. No adjustment shall be allowed for variation of plus/minus 10%.
AIR HANDLING UNIT Supply, Installation, testing and commissioning of double skin floor mounted type air handling units fabricated & assembled complete, made of 25 mm thick panels consisting of GI casing of thickness 0.6mm outside layer and 0.6mm inside layer, injected at factory by moulding machine with polyurethane foam (PUF) insulation complete with blower section and filter section with filter of 10 micron at 90% efficiency, chilled water coil constructed out of copper tubes not less than 0.5mm thickness and aluminum fins, Suitable capacity TEFC drive squirrel cage induction motor 415 ± 10% volts, centrifugal forward/backward curved fan suitable for 50mm SP, access door etc complete as per std. specification. Maximum face velocity across the coil shall be 500 FPM and each 6 Row deep chiller water cooling coil and 2 Row deep hot water coil and RH to be maintained at 65 % ± 5% of following capacities and comprising of: - a) Coil of copper tube and aluminium construction sized at maximum face velocity of 500 FPM. b) Pre filter of 10 micron at 90% efficiency on the face of the coil in return air stream. c) Squirrel cage induction motors suitable for 415 ± 10% volts, 50 Hz, AC supply meeting criterion as per ASHRAE standard 90.1-2007 and high efficiency. d) Fan belt drive package. e) Vibration isolators. f) Fan outlet velocity not exceeding 10 mps. Tag No. CFM AHU No. 1 to 3 15000
ELECTRIC HOT WATER GENERATOR Supply, installation, testing and commissioning of electric hot water generator 120 KW capacity complete with electrical immersion heaters bank, manual reset, high temperature cut off, ste controller, recycling relay, thermostat, polit light, low water control, electrical panel mounted on generator frame itself with internal wiring, contactor, switches, interconnection cable between panel and heater and cement concrete foundation. Hot water generator shall be suitable for 415+10% V, 3 Phase, 50Hz electricity supply, complete all as specified and directed. Note:- Next higher capacity of hot water generator will be supplied by the contactor without any extra cost to Govt. In case of non availability of capacity as specified.
Supply, installation, testing and commissioning of Pan type Humidifier of capacity 6 KW complete with SS sheet tank duly insulated and complete with control wiring, complete all as specified and direcetd.
COOLING TOWER Supply, Installation , testing and commissioning of FRP cooling tower of minimum 120 TR heat rejection capacity with FRP water basin PVC fillings with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self-rotating sprinklers, statically & dynamically balanced axial flow type fan direct driven or driven through reduction gear box with TEFC induction motor, suction screen, make up quick filling arrangement, over flow and drain connections with necessary valves and suitable inspection ladder, access arrangement for cooling lower interior, installed on MS girders (MS-I sections) fixed in masonry foundations with cement concrete footing, second class brick work and cement mortor 1:6; all accessories, basin fittings, fan, fan motor suitable for 415 Volt supporting structure, anti-vibration mountings etc. complete and 50 HZ power supply having isolator panel with MCB at cooling tower and with following technical data. a) Water flow/tower 480 USGPM b) Ent. Water Temp. 97°F c) Basin water Temp. 90° F
Supply, Laying, jointing and testing of following size PVC insulated aluminium/copper conductor armoured cables of 1.1 KV grade heavy duty confirming to IS in ground/ in ducts/in pipes/on cable trays complete with cable tray, clamps, saddles etc. including effecting proper connection to the equipment all as required, complete all as specified and directed by Engr-in-Charge. Notes:- (i) The cost includes cost of suitable pipes for cable protection at road crossings, cable trays, protective bricks, sand cushioning, excavation, returning filling and removal. (ii) All exposed cables in trenches/wall/ceiling/roof trusses shall be provided with silicon based fire resistance coating compatible for PVC cables. (iii) All terminations shall be made with proper lugs in the approved manner.
a) 3.5 Core x 95 Sqmm (aluminium) for Chillers & Hot Water Generator.
b) 3.5 Core x 35 Sqmm (aluminium) for main to AHU Panels.
c) 3 Core x 6 Sqmm (aluminium) for Chilled Water, Condenser pumps, Hot water Pump, CT Fan & AHU Blowers motors
d) 4Core x 1.5 Sqmm (cooper) for Controls
S & F GI earth strip 25 mm x 3 mm below ground, in 40 mm GI pipe wherever required and on surface or in recess for connections etc. complete all as directed. Note:- (i) All terminations shall be made with proper lugs in the approved manner.
M&L Earthing complete with galvanised steel earth plate electrode 600mmx 600mm x 6.0 mm thick burried directly in ground (Earth pit not less than 2.25 m deep below normal ground level) surrounded from all directions with charcoal dust, salt and edge of earth plate not less than 1.5 m below ground level connected to galvanized iron strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers made of glavanized iron and protected by galvanized iron pipe light grade 40 mm bore and watering pipe 20mm dia medium grade with funnel and wire mesh as specified and connected all as shown in electrical plate No 3 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1:2:4 type B - 1 in chamber and 80 mm thick precast RCC 1:2:4 type B - 1 using XPM weighing not less than 4Kg/Sqm for cover slab/coping complete all as specified. The GI earth strip & 40mm dia bore light grade GI pipe upto 7.5 mtr deemed to be included in the rate quoted by the contractor. Beyonnd 7.5 mtr GI earth strip and GI tubing light grade 40mm dia shall be measured and paid under the respective item of schedule all as specified and as directed by the Engr-in-Charge. Note: The unit rate quoted by tendrer is deemed to be include for necessary excavation, removal of surplus soil, PCC foundation, RCC cover, XPM weighing not less than 4Kg/Sqm, earth lead protection up to 7.5m etc complete.
S & F of 8 SWG GI wire, complete all as directed. Note:- (i) All terminations shall be made with proper lugs in the approved manner.
CHILLED WATER & HOT WATER PIPING Suppling, jointing, installing and testing of the following nominal sizes of chilled water and hot water plumbing pipes MS 'C' CLASS as per IS 1239 with necessary clamps, vibration isolators and fitting like valves, flanges, union etc. but excluding valves, strainers, gauges etc. cut to required lengths and welded at joints and inclusive of accessories like elbows, tees, reducers, sockets etc. including insulating with 19 mm (for all pipes) and 13mm (for drain pipe) thick closed cell chemically cross linked fire retardant polyethylene foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C, covered with aluminium sheet cladding 24 gauge complete with application with rubber based adhesive Pidilite SR 998 y, all as specified and repairing damage to building etc. and complete all as specified and directed.
(a) 125mm dia
(b) 100mm dia
(c) 80mm dia
(d) 65mm dia
(e) 50mm dia
Supply, fixing and testing in position the following valves, strainers, gauages etc, in chilled water plumbing and adequately supported complete with flanges etc. Care shall be taken to ensure that no damage would be caused to the insulation when valves, stariners are in operation. The Valves shall be as under:-
Supply, fixing and testing in position of following size Butterfly Valves (Manual) with CI body, Stainless steel disc, nitrile rubber seal & O ring, PN 1.6(16 bar) Pressure rating for chilled water circulation duly insulated to the same specifications as the connected piping
(a) 100mm dia
(b) 80mm dia
(c) 65mm dia
(d) 50mm dia
Supply, fixing and testing of balancing valve 2-way of following size, globe type, duly insulated to the same specifications as the connected piping as per following specification. Nominal pressure PN1.6 Medium Temperature -10oC~ +110oC Maximum Body Material IS:210, FG 220 CI Stem Material ASTM A276,GR SS 410 Disc Material Stainless steel Disc Hand Wheel Cast Iron Leakage Rate No visible leakage Medium Type Water Flange standard ISO7005-1 (GB/T 9113) Shell Test pressure 24bar Seal Test pressure 17bar
(a) 100mm dia duly insulated to the same specification as the connecting pipe.
(b) 80mm dia duly insulated to the same specification as the connecting pipe.
(c) 50mm dia duly insulated to the same specification as the connecting pipe.
Supply, fixing and testing of Non return/Check valve of following size with dual plate of CI body, Stainless steel plates, vulcanised NBR seal flanged ends and PN 1.6(16 bar) Pressure rating, all as specified and directed.
(a) 80mm dia
(b) 65mm dia
(c) 50mm dia
Supply, fixing and testing in position 32mm dia without insulation gun metal Gate or goble Valve all as specified and directed.
Supply, fixing and testing of Automatic air-vent having 15 mm dia with Brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide capm etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 115° C respectively, installed on all high points in the water piping system to automatically remove the trapped air, installed on all high points in the water piping system to automatically remove the trapped air etc., as required all as specified and directed.
Supply, fixing and testing of 25 mm dia Ball valves brass body with crutch suitable for screwed unions on both ends for drain with fittings, complete all specified and as directed.
Supply, fixing in position the industrial type pressure gauge 100mm size all as specified and directed.
Supply and fixing in position the mercury-in-glass industrial type thermometers all as specified and directed.
Supply and fixing in position the water flow switches for the Chilled water circuit complete with fittings, all as specified and directed.
Supply, fixing and testing of 3 way mixing valve for fixing in chilled water piping for AHU complete with required controls, wiring, installation kit complete all as specified and directed.
Supply, installation, testing and commissioning of proportional cooling only thermostats for the Air Handling Units complete with required controls wiring/installation kit etc. all as specified and directed.
Supply, laying/fixing and testing of the following nominal sizes of condenser water pipes MS ‘C’ CLASS as per IS: 1239, of following sizes and material along with necessary clamps, vibration isolators and fittings such as bends, tees etc but excluding strainer and gauges etc adequately supported on rigid supports/buried in ground including excavation& returning and filling etc complete all as specified and directed.
(a) 125 mm dia
(b) 100 mm dia
Supply, fixing and testing of Y-type strainer of following size with Cl/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection with accessories etc., as required all as specified and directed.
(a) 100mm dia
(b) 80 mm dia
(c) 65mm dia
EXPANSION TANK Supply and fixing of HDPE expansion tank of size 1000 Ltr complete with suitable FR- XLPE/XPE 19 mm thick of minimum bulk density 28±4Kg/cum covered with vapour barrier and finished with 0.5 mm thick Aluminium cladding and applied with Pidilite SR 998 complete with air vent and drain connection with float valve, quick fill and control valves and brick staging minimum 0.5 meter high above the height of cooling tower etc as required all as specified and directed. Note:- Necessary civil work viz. PCC in foundation & Brick work staging minimum 0.5 meter high above the height of cooling tower the rate quoted by the contractor deemed to including the same and nothing extra shall be admissible on this account.
Make Up Tank Supply and fixing of HDPE make up tank of size 5000 Ltr. complete with air vent and drain connection & overflow, make up connection with float valve & brick staging minimum 0.5 meter high above the height of cooling tower etc as required all as specified and directed. Note:- Necessary civil work viz. PCC in foundation & Brick work staging minimum 0.5 meter high above the height of cooling tower the rate quoted by the contractor deemed to including the same and nothing extra shall be admissible on this account.
AIR DISTRIBUTION (DUCT WORK)
Supply, fabrication installation and testing of Galvanized steel sheet, rectangular/round ducting for supply/return air system complete with neoprene rubber gaskets, elbows, splitter damper vanes, hangars, supports as per approved drawings of following sheet thickness as under, complete all specified and directed.
(a) 24 gauge galvanised steel sheet
(b) 22 gauge galvanised steel sheet
(c) 20 gauge galvanised steel sheet Note for Srl item no 23.10 to 23.13: (i) Air distribution system shall be designed by the contractor and submit the shop drawings of ducting layout for the approval of GE before execution of work without any extra cost to department. (ii) The duct work shall be as per IS-655 (iIi) The Galvanized steel sheet for duct work shall conform to class viii with zinc coating of 120 gm/sq mtr as per IS-277(2003).
Supply, fabrication, installation and testing of flexible duct connector constructed of fire resistant double resin sleeve as per approved shop drawings, complete all as specified and directed.
Grilles/ Diffusers Supply, fixing and testing of powder coated aluminium sheet of 20G for supply/return air grill/diffusers without aluminium volume control dampers, complete all as specified and directed.
VOLUME CONTROL DAMPER Supply, fixing and testing of GI volume control dampers made of 20G thick sheet, complete all as specified and directed.
Supply, fixing and testing of powder coated extruted aluminium sheet of 20G thick for fresh air grill in weather maker room with volume control damper, bird screen etc, complete all as specified and directed.
Supply, fixing and testing of motorised combined fire damper made of 20G GI sheet complete with control panel, inter connecting wiring, complete all as specified and directed.
Fire Damper
Actuator
Control Panel & wiring
THERMAL INSULATION
Supply and fixing of acoustic insulation of duct with 25 mm resin bonded fibre glass, of 48 kg/cum density, covered with and 28 Gauge Aluminium perforated sheet all as specified and directed.
Supply and fixing of thermal insulation of duct with 13mm thick closed cell chemically cross linked fire retardant polyethylene foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C, covered with aluminium faced foil complete with application with rubber based adhesive Pidilite SR 998 and 50mm x 3 mm thick self adhesive tape on both longitudinal & transverse joints, complete all as specified and directed.
Supply and fixing of Accoustic insulation of wall & ceiling of AHU Rooms with 50 mm thick resin bonded fibreglass of density 32 kg/m3. Accoustic insulation shall be fixed in 600 mm x 600 mm frame work made out of 0.6 mm thick GI sheet U shaped channel and covered with reinforced fibre glass tissue paper and finished with 0.8 mm perforated aluminium sheet including aluminium beading of 25 mm wide and 1.00 mm thick fixed on all horizontal and vertical joints by means of screws etc., complete as required and as specified.
Supply and fixing of Air curtain suitable for 2mtr wide and 2.5mtr high door complete with power blower fans and motor suitable for 230 V single phase 50 Hz AC supply outer body made of powder coated MS sheet complete all as specified and directed.
Supply and fixing of following size galvanised steel water tubing medium grade (ISI marked) with and all fittings such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, clamps etc concealed or fixed to wall, ceiling or laid in floors, complete all as specified and directed.
(a) 32mm dia
(b) 25mm dia
(c) 20mm dia
Supply and fixing of thermal insulation of duct with 25mm thick closed cell chemically cross linked (XPE) fire retardant polyethylene foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C, covered with aluminium sheet cladding with 28 gauge complete with application with rubber based adhesive Pidilite SR 998 and 50mm x 3 mm thick self adhesive tape on both longitudinal & transverse joints, complete all as specified and directed.
Projenix
Blue Star Limited
M/S N.K BUILDERS
SHRI RAMSONS PROJECTS CORPORATION
Pioneer Aircon
Jyoti Refrigeration
Leo Network power systems
Parksons Engineering Company Pvt Ltd
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .