| 1 | L1₹8.0 LAccepted-AOC VPO LITAR TEHSIL RAIKOT DISTRICT LUDHIANA | LUDHIANA | LUDHIANA | PUNJAB | L1 | Accepted-AOC Lowest L1 | |
| 2 | L2₹8.1 L+₹10,418 (1.30%)Rejected-AOC | L2 | Rejected-AOC Highest L2 |
Tender Value
Refer Docs
EMD Value
₹16,555
Closing Date
23 Sept 2021, 12:00 pmClosed
Executive Engineer -cum- Chairman GPWSC
Chairman GPWSC Village Chomon, Block Dehlon, District Ludhiana through Executive Engineer, Water Supply and Sanitation Division No.2, Partap Chowk, Metro Road, Ludhiana.
Providing improved access to water through household connections in existing Water Supply Scheme at Village Chomon, Block Dehlon, District Ludhiana. (Under PRWSSIP Sub Component 2a(i)/JJM)
2021_WB_71573_1
No.3547 dt.07.09.2021 (Chomon)
Open Tender
Civil Works
Item Rate
60 days
Ludhiana
Please refer Tender documents.
8 documents required · 8 mandatory
₹100
₹16,555
18 Oct 2021
8 Sept 2021
23 Sept 2021
8 Sept 2021
23 Sept 2021
8 Sept 2021
Amount
Providing Installing testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, and Chemical Dosing Chlorinator, Suitable for delivering 0.5 to 6 Liters of Bleaching Powder solution /Sodium Hypo solution per hour under maximum delivery pressure upto 7 kg.cm2 and suction lift not less than 1.5m per DWSS standard specifications.
Providing & Fixing of Automated Water Controller complete in all respect.
Providing, Stringing out PVC pipes ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches To correct alignment and gradients, including excavation cutting, Jointing, testing and back filling complete as per specifications for more than 3 mtr street width.
PVC pipe 63mm o/d (6kg/cm2)
Dismantling brick or flagged stone flooring without conerete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
Construction of Masonary Sluice Valve Chamber excluding sluice valve cover as per standard design & drawings of public health department.
0.60mtr. x 0.60 mtr.
Providing Household connection laying, jointing, fixing testing MDPE pipes (as approved by Engineer-in-charge) including cost of excavation refilling , C.I bib clock as IS:210 with stainless steel spindle 20 mm o/d MDPE pipe 4.50 mtr (2.50 mtr. MDPE & 2.00 mtr G.I, vertical pipe) 3" i/d uPVC clamps, GM ferrule ISI marked connection of 15 mm i/d ferrule medium, specials such as tees, bends, sockets, elbows, nipples (100 mm & 150 mm) union couplings, MDPE pipeline laid in the ground or inside building, cutting, treading, making hole in wall and testing in trenches in ground complete in all respect.
On Existing Pipe Line
On New Pipe Line
Development of water works site
i) Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8 (as per Analysis A-6)
ii) Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8 & (as per Analysis A-6).
iii) Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7 & Analysis A-7
iv) Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3 & Analysis A-3.
Repair of Pump Chamber
i) Hollock wood doors shutter windows shutter including hinges, screws, Chocks Cleats, Stops and Cords etc. complete fixed in position (double Leaf) @ paneled glazed or glazed and paneled
Panelled, Glazed or glazed and panelled.
40 mm thick
windows 1x3x0.50x0.60=0.90 sq mtr
ii) Distempering with dry distemper of approved manufacture two coats over one priming coat to give an even shade
Pump Chamber 3.70x4.30
Long wall 4.30x3x2x2 =51.60 Sqm
Short wall 3.70x3x2x2 =44.40 Sqm.
Top 3.70x4.30 = 15.91 Sqm.
Total=111.91 Sqm
Repair of OHSR
i) Expansion Joint (100 mm)
ii) Construction of brick masonry over flow houdi of size 1.20 x 1.20 x 1.20 m for OHSR complete in all respects as per analysis A-21
iii) Repair of Tank Dome
Painting of Sign Board
O & M (Electricity Bill)
Provision for bleaching powder or sodium chlorite for disinfection of water.
Bhupinderpreet Singh Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .