Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹14.3 L+₹1.4 L (10.6%)Accepted-AOC | L2 | Accepted-AOC Not accepted due to tenderer not L1 | |
| 3 | L3₹15.7 L+₹2.8 L (21.5%)Accepted-AOC D 502 SHIVILOK COLONY RAIPUR ROAD DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | L3 | Accepted-AOC Not accepted due to tenderer not L1 | |
| 4 | L4₹15.8 L+₹2.8 L (21.8%)Accepted-AOC | L4 | Accepted-AOC Not accepted due to tenderer not L1 | |
| 5 | L5₹16.6 L+₹3.6 L (28.0%)Accepted-AOC | L5 | Accepted-AOC Not accepted due to tenderer not L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
7 Jun 2021, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Military Engineer Services Roorkee-247667
REPAIR CLEANING LAYING OF SEWAGE LINES MANHOLES SEPTIC TANKS DRAINS FENCING COMPOUND WALL GATES AND CLEANING OF LIFT WELL ETC IN POCKET 1 2 3 AND 4 IN THE AREA OF AGE BR I UNDER GE ROORKEE
2021_MES_441454_1
8392/037/E8
Open Tender
Civil Works
Item Rate
180 days
Roorkee Cantt
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (MES) Roorkee
₹40,000
Yes
5 Aug 2021
8 May 2021
9 Jun 2021
10 May 2021
7 Jun 2021
24 May 2021
Amount
M&L for cleaning of blocked/chocked sewer pipe line of 100 mm dia from manhole to manhole etc or from cleaning eyes in any depth by rodding or by mechanical means and well flushing the complete line including removing of sludge /waste to low lying area within 200 m distance and burrying the same properly to the entire satisfaction of Engineer-in-Charge including taking out and re-fixing of manhole cover in cement mortar (1:4) as and where required complete all as specified and directed. Note for item No.1 to 10 : Contractor or his accredited representative/ supervisor will report to the I/C Maint of AGE B/R-I at 8.30 AM on every working day alongwith adequate Nos of Safaiwala to collect the complaint slips and will report the completion to the concerned I/C Maint on the same day. All blockages/complaints to be cleared within 24 Hrs. If any blockage is not cleared within 24 Hrs, a panelty of Rs 250/- to be imposed to the cotractor for every day of delay for each pending complaint.
M&L for cleaning of blocked/chocked sewer pipe line of 150 mm dia from manhole to manhole or from cleaning eyes in any depth by rodding or by mechanical means and well flushing the complete line including removing of sludge /waste to low lying areas within 200m distance and buryiing the same properly to the entire satisfaction of Engineer-in-Charge including taking out and re-fixing of manhole cover in cement mortar (1:4) as and where required complete all as specified and directed.
M&L for cleaning of blocked/chocked sewer pipe line of 150 mm dia sewage line (exc 1.5 m and n.exc 3.00 m in depth from top of manholes to bottm of pipe line) by rodding or by mechanical means and well flushing the complete line including removing of sludge /waste to low lying areas within 200m distance and buring the same properly to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers duly set in cement mortar 1 : 4 as wherever required complete all as specified and directed.
M&L for cleaning of blocked/chocked sewer pipe line of 200 mm dia sewage line (exc 1.5 m and n.exc 3.00 m in depth from top of manholes to bottm of pipe line) by rodding or by mechanical means and well flushing the complete line including removing of sludge /waste to low lying areas within 200m distance and buring the same properly to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers duly set in cement mortar 1 : 4 as wherever required complete all as specified and directed.
M&L for cleaning of blocked/chocked sewer pipe line of 200 mm dia at depth exc 3 m but n.exc 4.5 m from top of man hole to bottom of pipe line, by rodding or by mechanical means and well flushing the complete line including removing of sludge /waste to low lying areas within 200m distance and burrying the same properly to the entire satisfaction of Engineer-in-Charge including taking out and re-fixing of manhole cover in cement mortar (1:4) as and where required complete all as specified and directed.
M&L for cleaning of blocked WC including cleaning line from WC trap upto first manhole complete all as specified and directed.
M&L for cleaning of blocked nahani trap of bathroom, kitchen & WHB including cleaning of pipe line upto gully trap as required complete all as specified and directed.
M&L for cleaning of blocked gully trap complete all as specified and directed.
Taking off existing covers of septic tank, cesspool, soak well, lift well, soak pit or manholes of any size/capacity and cleaning by dewatering and taking out sludge in liquid mud, silt or in solid state after emptying the water with the help of combined high pressure water jetting cum suction (Vacuum) type machine mounted on vehicle having facilities of high pressuere of water thermoplastic fiber blended water jetting hose & through conical or round shaped nozzle pipe and removing the sludge outside MD land at approved locations and burrying the same in newly excavated pits of suitable sizes and covering with excavated earth and placing back in position the removed covers and set in cement mortar (1:4) complete all as specified and directed.
Taking off existing covers of soak well/ septic tank/ manhole and cleaning by mechanical suction pump tanker of capacity 3000 Ltrs and laying/ throwing out of MD land at approved locations as per arrangements made by the contractor and placing back in position the removed covers and set in cement mortar (1:4) complete all as specified and directed.
Excavation in trenches n.exc 1.50 m wide & n.exc 1.50 m in depth for foundation or for manholes, cesspits, shafts etc not exc 10 Sqm on plan and getting out in soft / loose soil, complete all as specified and directed.
Excavation in trenches n.exc 1.50 m wide & exc 1.50 m but n.exc 3 m in depth for foundation or for manholes, cesspits, shafts etc not exc 10 Sqm on plan and getting out in soft / loose soil, complete all as specified and directed.
Taking out / demolition and breaking up drain pipes (Salt glazed stone ware, AC or Reinforced concrete) of 150 mm internal dia, set in cement mortar complete all as specified and directed by Enginner-in-Charge.
M&L for SGSW drain pipe of 150 mm internal dia, grade `A', laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed by Enginner-in-Charge.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregrate) as in bed to 150mm internal dia SGSW drain pipes including packing under and haunching against sides of pipes after they are laid and tested complete all as specified and directed by Enginner-in-Charge.
Taking out / demolition and breaking up drain pipes (Salt glazed stone ware, AC or Reinforced concrete) of 200 mm internal dia, set in cement mortar complete all as specified and directed by Enginner-in-Charge.
M&L for SGSW drain pipe of 200 mm internal dia, grade `A', laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed by Enginner-in-Charge.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregrate) as in bed to 200 0mm internal dia SGSW drain pipes including packing under and haunching against sides of pipes after they are laid and tested complete all as specified and directed by Enginner-in-Charge.
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for manhole covers etc complete all as specified and directed by Enginner-in-Charge.
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed .
M&L for brick work with old size sub class ‘B’ bricks in cement mortar (1:6), straight or curved on plan exc 6 m mean radius complete all as specified and directed.
M&L for brick work with old size sub class ‘B’ bricks in cement mortar (1:4), straight or curved on plan exc 6 m mean radius complete all as specified and directed.
M&L for brick work with old size sub class ‘B’ bricks in half brick thick walls in cement mortar (1:4), straight or curved on plan exc 6 m mean radius complete all as specified and directed.
M&L PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation of manholes, filling and mass concrete etc complete all as specified and directed
M&L PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in surfaces channels & drains complete all as specified and directed.
Extra for forming fair finished drains & channels 30 cm inner girth in cement concrete, using extra cement, including forms, moulds etc complete all as specified and directed (Inner girth only measured).
Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed .
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in cills, coping, bed plates, bed blocks for hold fasts, apex stones and the like with plain fair faces including weathering, slightly rounded or chamfered angles and throating and necessary form work complete all as specified and directed.
Demolition of reinforced cement concrtete of any description and in any position (including cutting reinforcement if required to facilitate demolition) complete all as specified and directed.
M&L for precast reinforced cement concrtete (1:2:4) type B-1 (using 20mm graded stone aggregate) in manhole covers including necessary form work and fixing in postion in cement mortar (1:4) complete all as specified and directed.
S&F mild steel TMT reinforcement bars 6 mm to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F mild steel TMT reinforcement bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F MS framed work such as grills, gratings, gate etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tank and similar work conforming to Fe 290 Gde E165 complete all as specified and directed.
Returning filling in with excavated soil including spreading, leveling, watering & well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
S&F 75mm dia bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 75mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls including necessary clamps etc complete all as specified and directed.
S&F 75mm dia bore PVC (SWR) junction single (Single T), equal or unequal complete all as specified and directed.
S&F 110mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) floor trap with outlet of 75mm dia, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) gully trap of size 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F in repair vitreous china sqatting pan of pattern "long pan", size 580mm white with cast iron `P' or `S' trap, front or back inlet and foot rests any pattern including demolition of existing WC seat etc, providing PCC 1:5:10 type E-2 (using 40mm graded stone aggregate) and making good PCC/Terrazo/ tiles floor to match with the existing floor and making connection to flush pipe etc complete all as specified and directed.
S&F in repairs viterous china wash down water closet pan (Pedestal pattern) white including 'P' or 'S' trap and making good the disturbed surface to match with the existing complete all as specified and as directed.
S&F in repairs plastic water closet (EWC) seat cover, white, closed pattern with flat bottom and cover including mild steel chromium plated hinging device complete all as specified and directed.
S&F in repairs 10 Ltrs PVC (White) valve less syphonic action type, low level flushing cistern with inlet, ball valve float, handle, Aluminium brackets for bottom support fixing with gitties embeded in wall with drilling machine etc complete all as specified and directed.
S&F stainless steel jet cleaner for ‘E’ type WC with flexible pipe of suitacble length complete all as specified and directed.
S&F health faucet with 8 mm dia 1.20 mtr long flexible tube & wall hook complete all as specified and directed. Make : Jaguar Cat part No. ALD-573 equivalent range of MARC, JOHNSON.
S&F MS work as in hold fasts, bands, supports, clamps, wall ties hooks including nut and bolts, sliding door bolts hand made and similar small articles conforming to Fe 290 Gde E165 including welding etc complete all as specified and directed.
M&L for non-skid ceramic joint free coloured tiles 7 to 8mm thick (Square/Rectangular) area of each tile exc 0.06 Sqm but n.exc 0.11 Sqm, laid in flooring over and including 15mm thick screed bed in cement mortar (1:4) and dismantling of existing tiles etc complete all as specified and directed.
M/s RAM RATAN AND SONS
VINAYAK CONSTRUCTION COMPANY
sagar associates
RAJENDER CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .