| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L1 | Accepted-AOC L1 AND ACCEPTABLE | |
| 2 | L2₹20.6 L+₹18,303 (0.90%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹20.8 L+₹34,980 (1.71%)Rejected-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹21.1 L+₹67,091 (3.28%)Rejected-AOC | L4 | Rejected-AOC Not L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
31 Jan 2024, 6:00 pmClosed
CWE AHMEDABAD
CWE AHMEDABAD
REPAIR TO HT CABLE AND SERVICING OF TRANSFORMER, VCB AND GOD UNDER AGE E/M OF GE (ARMY) AHMEDABAD
2023_MES_629657_2
87213/E8
Open Tender
Civil Works
Item Rate
120 days
ARMY AREA AHMEDABAD
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (A) AHMEDABAD
₹40,000
Yes
6 Apr 2024
12 Jan 2024
2 Feb 2024
12 Jan 2024
31 Jan 2024
19 Jan 2024
Amount
Excavation in trenches in any type of soft/ loose soil not exceeding 1.5 Meter in width and not exceeding 1.5 Meter in depth and getting out all as required for laying of cables, foundation filling of poles or stays. Complete all as specified and as directed.
Returning filling, in including spreading, leveling, watering and well ramming in layers not exceeding 25cm each all as required. Complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point. Complete all as specified and as directed.
Supply and laying of DWC (double wall corrugated) HDPE pipe, ISI marked, IS 16205 (part 24) : 2017 Part II of outer dia 77 mm and inner dia 63mm with smooth internal and profiled external surface for non pressure underground cables including all connected accessories like coupler, o-ring etc complete all as specifed and as directed.
Steel tubes ISI marked light grade galvanised with all fittings fixed to walls/ poles as required of following sizes:- Complete all as specified and as directed.
80mm bore
100mm bore
Labour and tools for horizontal boring upto 20cm dia through road/ path/ floor for passing UG Cables by using trench less technology for laying complete all as specified and as directed. Note: Galvanised Iron/ DWC pipe will be measured and paid seperately.
Servicing of step up/ down transformer 63 KVA to 250 KVA after dismantling HT/ LT side cable terminals, earthing connections, opening top cover, taking out transformer oil, transformer core carefully, cleaning the sludge and carbon particle from main tank and conservator tank, taking out burnt HT/ LT bush rods and HT/ LT bushing and re-assembling, refilling the transformer oil, making electrical/ earthing connections using suitable size of Aluminium/ Copper lugs after repair/ replacement of burnt/ unserviceable parts including transportation from site to repairer shop and back to site including testing and recommissioning complete all as specified and as directed. Note: The major parts required for the repair will be measured and paid separately under relevant items. The nuts, bolts, washers required for repairing are deemed to be including in the quoted rates.
All as specified as per item number 07 hereinbefore but capacity above 250 KVA upto and including 500 KVA complete all as specified and as directed.
Material and labour for brass stud, bush rod complete for HT bushing of Transformer upto 250 KVA capacity including taking down old unserviceable bushing complete all as specified and as directed.
Material and labour for brass stud, bush rod complete for LT bushing of Transformer upto 250 KVA capacity including taking down old unserviceable bushing complete all as specified and as directed.
Material and labour for breather with new silica gel of Transformer 63 KVA to 500 KVA capacity including taking down old unserviceable breather complete all as specified and as directed.
Material and labour for replacing existing unserviceable silica gel with new crystal clean silica gel for the breathers of transformers capacity 63 KVA to 500 KVA complete all as specified and as directed.
Material and labour for rewinding of transformer core winding 63 KVA to 250 KVA complete using appropriate size of copper wound wire (HT coils), complete all as specified and as directed.
Material and labour for rewinding of transformer core winding 63 KVA to 250 KVA complete using appropriate size of copper wound wire (LT coils), complete all as specified and as directed.
Material and labour for rewinding of transformer core winding 315 KVA to 500 KVA complete using appropriate size of copper wound wire (HT coils), complete all as specified and as directed.
Material and labour for rewinding of transformer core winding 315 KVA to 500 KVA complete using appropriate size of copper wound wire (LT coils), complete all as specified and as directed.
Material and labour for painting of Transformer after removing the existing deteriorated paint by scrapping the complete body, filling cavities and spray (filtered) painting with two coats of synthetic enamelled paint over one coat of red oxide zinc chrome primer and marking of SM/ MES Number (required size and shape) with white paint for following capacity:-
Upto 200 KVA
250 KVA to 500 KVA
Material and labour for dehydration of transformer oil with mobile transformer filteration plant at site with all required accessories connected to transformer and carrying out filteration of old transformer oil for the desired dielectric strength of 50 KV at 2.5mm gap complete all as specified and as directed. Note: - Test certificate shall be submitted before and after filteration for dielectric strength.
Material and labour for top up of new transformer oil low viscoscity EHV grade confirming to IS-335 with the help of filteration machine including drain out complete low viscosity carbonised transformer oil complete all as specified and as directed.
Material and labour detection and locating of cable fault in underground damaged HT cable any size of any length and any type using cable fault detector/ locator machine of accuracy to 2 meters, vehicle mounted for various locations under GE (A) Ahmedabad including necessary excavation & earthwork in any type of strata of size required for visually inspection/ repairing the damaged cable when and where directed by Engr-in-Charge. Complete all as specified and as directed.
Material and labour for detection and locating of cable fault in underground damaged LT cable any size of any length and any type using cable fault detector/ locator machine of accuracy to 2 meters, vehicle mounted for various locations under GE (A) Ahmedabad including necessary excavation & earthwork in any type of strata of size required for visually inspection/ repairing the damaged cable when and where directed by Engr-in-Charge. Complete all as specified and as directed.
Material and labour for cold shrinkable type HT end termination joint indoor type for cable of size 3 core x 95 sqmm 11 KV including removal of old unserviceable joint complete all as specified and as directed.
Material and labour for cold shrinkable type HT straight through joint for cable of size 3 core x 95 Sqmm 11 KV including removal of old unserviceable joint complete all as specified and as directed.
Material and labour for cold shrinkable type HT end termination joint outdoor type for cable of size 3 core x 95 sqmm 11 KV including removal of old unserviceable joint complete all as specified and as directed.
Material and labour for cold shrinkable type LT straight through joint outdoor type for cable of size 3.5 core x 300 sqmm including removal of old unserviceable joint complete all as specified and as directed.
All as specified in item No 25 hereinbefore but 3.5 core x 120 sqm to 150 sqm complete all as specified and as directed.
All as specified in item No 25 hereinbefore but 3.5 core x 70 sqm to 95 sqm complete all as specified and as directed.
Supply, laying in trenches, connecting, testing and commissioning HT 11 KV underground cable stranded Aluminium Conductor (E), extruded semi conducting compound XLPE insulated, Galvanised steel flat strip armoured, PVC sheathed cable inner sheath of PVC tape confirming to IS 7098/II/85 of cross section area HT 95 sqmm x 3 core complete all as specified and as directed.
Supply and fix earth continuity conductor or main earthing lead of size 25mm x 4mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthling etc, as required complete all as specified and as directed.
Material and labour for pipe in pipe chemical earthing with galvanised iron pipe electrode 3.0 meter long having outer pipe dia 80mm & inner pipe dia 50mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium Sulphate 10% buried in ground by digging a bore of 150mm dia surrounded by soil friendly backfill compound non soluble in water including connection with galvanised earth strip 32mm x 6mm, making plain cement concrete pit of size 0.3 meter x 0.3 meter x 0.3 meter (inner size) in mix 1:3:6 type C1 (using 20mm graded stone aggregate) with RCC 1:2:4 type B1 (using 20mm graded stone aggregate), 40mm thick cover reinforced with 8mm dia mild steel bars 3 Numbers both ways with lifting hook made out of 8mm dia bar and testing on completion to achieve value not more than 1.0 ohm complete. Complete all as specified and as directed. Note: - Galvanised iron strip size 32mm x 6mm upto 7.5 meter included in the item).
Supply and fix of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Dismantling cross arms of any size from the existing poles by disconnecting from the insulators and keeping at side for re-use/ re-fixing complete all as specified and as directed.
Supply and fixing pin type, porcelain vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height 150mm dia for 11000 volts grade. complete all as specified and as directed.
Dismantling of existing GOD outdoor type 11 KV complete all as specified and as directed.
Supply and fixing in repairs gland operated AIR Break Switch tripple pole mechanically operated mounted on insulator & steel frame with operating mechanism work from ground level suitable for 11 KV for current rating upto 400 Amp of approved make with and including operting rod, Galvanised iron tubing 25mm dia medium grade single piece of 6.2 RM and handle complete all as specified and as directed. Note:- AB Switch shall be consists of 05 insulators per phase and 15 isolators in all.
Supply and fix lightning arresters explusion type complete with all fittings transmission class discharge capacity 65 Kilo Amp suitable for 11000 volts complete including taking out old unserviceable lightning arrester complete all as specified and as directed.
Suply and fixing for replacement of MCCB 4 pole, 415V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and as directed.
MCCB 4 pole, 415 V, adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and as directed.
MCCB 4 pole, 415 V, adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and as directed.
Demolition of cement concrete unreinforced of any description and in any position not otherwise specially provided for complete all as specified and as directed.
Material and labour for cement concrete in foundation, filling and mass concrete type D2 (1:4:8) (Using 40mm graded stone aggregate) complete all as specified and as directed.
Material and labour for cement concrete as in coping including form work type B1 (1:2:4) (Using 12.5mm graded stone aggregate) complete all as specified and as directed.
Supply and fixing of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for LT, 20 cm x 15 cm size and entire satisfaction of GE. Complete all as specified and as directed.
Material and labour for construction of brick masonary platform in cement mortar 1:4 of size 2400mm x 1800mm x 1200mm for outdoor type transformer having sides finished with brick work with plaster complete with plain cement concrete foundation of 1:5:10 type E2 (using 40mm graded stone aggregate) and plain cement concrete platform at top with 30 cm thick of plain cement concrete 1:5:10 type E2 (using 40mm graded stone aggregate) and 10cm thick of plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) and having brick steps at one side, complete with XPM jali duty welded with angle iron of size 50mm x 50mm x 6mm all around upto 0.6meter, including excavation and earth work in any type soil, returning filling in and removal of surplus soil upto 50 metre complete all as shown on drawing, as specified and as directed.
Cutting bushes, levelling the area around E/M installation, sub stations, pole structure etc including surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out roots etc and throw away not less than 50 meter from the site and making good complete all as specified and as directed.
Material and labour for dismantling Vaccum circuit breakers of rating upto 630 Amp, 11 KV, 3 Phase, by removing incoming and outgoing cable connections, removing busbars, current transformers, moving and fixed contacts cleaning all the parts with CTC, servicing of spring charge motor, checking the healthiness of tripping and closing coils, improving the insulation resistance value and reassembling the same complete all as sepcified and as directed. Note: Work should be carried out in presence of competent service Engineer.
Material and labour for calibration of following relays, setting the relays for the fault levels as directed by Engineer-in-Charge and testing the operation of Vaccum Circuit Breaker after installation of relays by simulating different types of faults complete all as specified and as directed. Note: Work should be carried out by competent service Engineer and report should be submitted on post completion of calibration.
Earth fault relay
Over current relay
Material and labour for replacement of existing old unserviceable alluminium tube terminals (Thimbles) of size 150 sqmm to 300 sqmm complete all as specified and as directed.
Material and labour for replacement of existing old unserviceable alluminium tube terminals (Thimbles) of size 95 sqmm to 120 sqmm complete all as specified and as directed.
Material and labour for replacement of existing old unserviceable alluminium tube terminals (Thimbles) of size 50 sqmm to 70 sqmm complete all as specified and as directed.
Material and labour for replacement of existing old unserviceable alluminium tube terminals (Thimbles) of size 35 sqmm to 50 sqmm complete all as specified and as directed.
Material and labour for replacement of existing old unserviceable alluminium tube terminals (Thimbles) of size 25 sqmm complete all as specified and as directed.
Material and labour for replacement of existing old unserviceable alluminium tube terminals (Thimbles) of size 6 sqmm to 16 sqmm complete all as specified and as directed.
Supply, errect, test and commissioning bus bar feeder pillar box of CPRI approved factory fabricated, dust & vermin proof including removal cable entry gland plate, powder coated 440 Volts, 3 Phase, 4 pole, 50 cycles outdoor type weather proof made out of 3.15mm thick Mild steel sheet, with in commer and outgoing through bus bar, with angle iron legs of suitable size and thickness of sheet 3.15mm, hinged door, locking arrangement with aluminium bas bar 600 Amps capacity, LED indicating lamp for RYB grouted, plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate and duly powder coated painted with two coats of synthetic enamel paint over one coat of primer comprising the following:- (Drawing/ design of panel shall to be approved by Engineer-in-Charge and GE before given order to concern factory). (i) Incoming:- One number MCCB 400 amp, 4pole, lcs 36 KA, 415 volts, 50 Hz with complete all as specified and as directed.
ALBA AC AND REF SERVICES
Abhishek Enterprises
M/s Matadeen Ramchandra Agarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .