SUPPLY AND ERECTION FOR CANOPY AT MADHYA PRADESH STATE OF CENTRAL ZONE
2300008460-HD-09050
5100008460
Open Tender
Ludhiana, Punjab
₹0
Exempted
21 Dec 2023
30 Nov 2023
21 Dec 2023
21 Dec 2023
30 Nov 2023 - 9 Dec 2023
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | STRUCTUAL STEEL FOR | STRUCTUAL STEEL FOR — pplying, transporting, fabricating, erecting in position in position of Prefabricated steel structures at all elevations for Canopy ing structural steel sections ISMB/ISMC/ISA conforming to IS:2062 and IS 226 , including cutting, welding or bolting, supply of bolt nuts/washers etc., complete as per drawings including surface preparation and applying one coat of Zinc Phosphate Primerbefore ere ion, one coat after erection and two coats of synthetic enamel paint as per specification after erection and all materials and labou complete. ( No welding is permitted at site). The rate quoted shall include cost of bolts, nuts, washers, welding and electrodes and ny other consumables required for completing the work. Nut bolts shall not be considered for payment.Theoretical wight of steel sect ns shall be considered for payment..(.(No measurement shall be taken for nut,bolt,washer splice plate & gusset plate) | - | Metric ton |
| 2 | CLIPPON ROOFING | CLIPPON ROOFING — pply and fixing Clippon Roofing System:Roofing base material should be of cold rolled steel of 0.55 mm thick and conform to ASTM:A 46 having yield stress of 275 MPA . The coating should be Aluminum and Zinc alloy comprising 55% Al , 43.5 Zinc & 1.5 % Silicon , as er ASTM :A 792 . The coating mass should not be less than 150 Gms per SqM (total of both sides). For, bare galvalume, TCT should not e less than 0.55 mm . Sheets shall have approved side laps with top sheets facing away from the prevailing weather. Necessary profil filler box should be provided at higher level of roof sheeting and at valley gutter to ensure water tightness in the profiled gaps The fixing of roofing shall be done in such a manner that the roof is not drilled / punctured for fixing with the purlins . Refer to he approved makes given in the Attachment. Flashings, Cappings and trims:These shall be formed out of same substrates as that of t roofing sheets and shall be supplied in standard lengths of 2.5 M in the required shapes and girths and fixed by means of hex-head chanically galvanized stitching screws. Silicon sealant non-hardening neutral cure type shall be applied at all laps to avoid water epage. | - | square meter |
| 3 | FALSE CEILING | FALSE CEILING — oviding & fixing false ceiling system of Trac 150 F exterior grade or approved equivalent of 0.5mm thick galvanised steel with stove nameled coil coated finish inter locking ceiling panels, carriers, suspension system and edge closure as per the following specifica on. Supplying and installation of exterior grade 150 F ceiling system comprising of 150 mm x 17 mm deep panels roll formed out of 0. mm galvanised steel with stove enameled coil coated finish. The panels shall be pre-treated and coil coated on one side in manufactu rs standard colour shades as approved by the Architect/ Engineer in charge. The rear side of the panel shall be given a coat of prim and a wash coat while the finished side shall be given a coat of primer and finish colourcoat in polyster paint for a min. dry fi thickness of 20 microns, fixed on to the roll formed carriers 34.5 mm x 488 mm deep out of 6 mm thick Galvanised steed with prongs hold panels in the module of 150 mm at maximum 1.2 mts. C/C. The carriers to be suspended from roof truss by rigid suspension angle as per manufacturer's recommendation. Panels shall be supplied in custom length upto maximum of 5 mts. Job also includes providing c ling flashing using factory formed 0.5 mm thick Polyster coated galvanised steel material. Rate shall be including providing flashin to cover gap if any between illuminatedbanding and false ceiling. | - | square meter |
| 4 | GI FACIA | GI FACIA — pplying and fixing 20 SWG GI sheet facia including painting with one coat of zinc chromate primer and two coats of 1 st quality synt tic enamel paint on front side . Necessary facia framework for fastening the sheet to the canopy securely shall be paid separately. | - | square meter |
| 5 | AL GUTTER | AL GUTTER — oviding and fixing 2 mm thick Aluminum Sheet Gutters of required shape in slope with 40 mm x 3 mm MS. Brackets at 1000 mm maximum sp ing and 8 mm dia G.I. J or L hooks, boltsand nuts, GI Limpet and bitumen washers, providing nut bolt joint , sealing the joints with ilicon sealant testing the gutter for leakage by filling water etc. Complete.(Refer attached Drawing .For allowable tolerance refer IS codes | - | meter |
| 6 | 6" PVC PIPE | 6" PVC PIPE — oviding and fixing 6" dia PVC pipes of 6 Kg/sqcm of approved Make as per IS 4985 for rain water pipes including all fittings like ba s , shoes etc., MS fabricated bracket as per requiment etc. All complete as directed by the EIC. | - | meter |
| 7 | 80 W LED | 80 W LED — W LED Fitting as mentioned in IS standards IS 16101 to 16107:Supply and fixing of 80 W LED housed by Single piece Pressure Die Ca Aluminum body, recess mountable fitting with guaranteed burning hours of 50000 .Make Philips/Havells/Bajaj/Wipro/Osram/Crompton/GE/ ver Innovations. IP Protection of minimum IP 65 and above, suitable for canopy lighting at retail outlets (Petrol station) .The bidd should submit copy of certified photometric report as per IESNA LM-79(Approved method for the Electrical and Photometric Measuremen of Solid-State Lighting Products) from a UL/ ERTL /ERDA or any NABL accredited laboratory to validate the photometric claims as & w n asked by HPC.A minimum 3 years warranty from manufacturing defects for the luminaire by manufacturer.i) With high lumen effica LEDs from CREE, Seoul Semi-Conductor, Lumiled Philips, Osram, Nichia (Japan), Tridonic (Austria), GE and Bridgelux .Efficiency of ore than 90 lumens per watt . LEDs used in the fixture should be from the same bin and certified as per LM- 80 (IESNA: Approved Metho for Measuring Lumen Maintenance of LED Light Sources and LED lumen depreciation time to L70 based on LM-80 data). by any UL/ ERTL /E A or any NABL accredited laboratory to validate the photometric claims as & when asked by HPC.ii) Bottom open able for easy mainte nce.iii)High Quality Polycarbonate Opal Diffuser for Optimum uniformity and Glare free light output.v) General electrical protec on against High Voltage and Surges up to3 KVv) Power factor > 0.95vi) Range allowed for total system wattage 80 W with +2W or -2 vii) Driver Operating Voltage Range: 140 V- 270 V viii) Operating Temperature 0 to +45 Deg Centigrade viii) CRI more than 70ix) C our temperature5650K±500K (to be mentioned in LM 79 certificate) x)Wide beam angle for spread of light 120 degrees or more xi)Lu naire Performance Complies to IS10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529, ROHS | - | Each |
| 8 | 4CX2.5 SQMM COPPER CABLE MPLP-CVR PURCHASE PLANT | 4CX2.5 SQMM COPPER CABLE MPLP-CVR PURCHASE PLANT — pply and laying following size PVC insulated, sheathed, armoured cable of approved make conforming to IS 1554:Part 1:1988 4CX2.5SQMM OPPER CABLE | - | meter |
| 9 | 4CX2.5 SQMM END | 4CX2.5 SQMM END — D TERMINATION End termination of following cable with double compression NFLP gland and crimping sockets 4CX2.5 SQMM END TERMINATION | - | Each |
| 10 | HIRIB ROOFING | HIRIB ROOFING — oviding and installing roofing Ribbed roofing system manufactured with high strength steel grade of G550( 550MPa) of ZINCALUME steel r approved equivalent bare Galvalume high tensile cold rolled steel as per ASTM 117 A792M /AS 1397 Coating class AZM 150 ( minimum 1 gm/sqm Zinc-Aluminium alloy coating mass total of both sides),of Yield strength 550 Mpa Thickness of bare metal (BCT): 0.40mm ,Tota coated thickness(TCT) : 0.45 mm .Approximate mass of roofing sheet shall be 4.17 Kg/sqm. Panels shall be of Min. 900 mm wide and Min corrugation depth of 38 mm with varying lengths as per Site requirements Rateshall be including laying of sheets with approved fas ners and also all weather sealant tape as per Mfr's recommendationsand also providing ribbed galvalueme ridge pieces of the same cla as of the matching corrugation profile of the roofing system as recommended by the Mfr.and , horizontal/vertical flashing near illu nated banding . | - | square meter |